HomeMy WebLinkAboutWALL ASSEMBLY DETAILSWOOD SHEA
WOOD CONSTRUCTION
%" HAT CHANNEL W/ %11
TYPE "X" DRYWALL
WOOD SHEATHING
WRB LAYER *11 -
5TUCCOWRAP (OR
APPROVED EQUAL)
$" TNICK, 3 COAT -
CEMENT PLASTER
WRB LAYER #1,
5TUCCOWRAP
(OR APPROVED EQUAL)\
AMICO AM66-WFWC-150 —
CUSTOM CA51NG BEAD
(OR APPROVED EQUAL)
DO NOT CAULK OR
SEAL GAP
WRB LAYER 01, 5TUCCOWRAP
(OR APPROVED EQUAL)
WRB LAYER #2, FORTIFIBER BUILDING
PAPER (OR APPROVED EQUAL)
8° THICK, 3 COAT CEMENT
PLASTER
AM66-WFWC-100 CUSTOM CA51NG
BEAD (OR APPROVED EQUAL)
WRB LAYER #I, 5TUCCOWRAP
(OR APPROVED EQUAL)
WRB LAYER 12, FORTIF15EIR BUILDING
r PAPER (OR APPROVED EQUAL)
6" SELF-ADHEREING FLASHING
WRAPPED @ CORNER OF CANTILEVER
AMICO AM(o(o-WFWC-150 CUSTOM
CASING BEAD (OR APPROVED EQUAL)
(W/OPT. WEEPS)
CASING BEAD DETAIL @ CANT.
LEGEND
DRAINAGE PLANE
(WRB LAYER #I, STUCCOWRAP
OR APPROVED EQUAL
WRB LAYER 02
(FORTIFIBER BUILDING PAPER
OR APPROVED EQUAL)
METAL LATH
X X X X
STUCCO
WOOD SHEATHING --ii�T%%
5ELF-ADHE5IVE FLA514ING
VINYL (OR APPROVED -
EQUAL) CASING BEAD
S/O' TYPE "X" DRYWALL
W/TEXTURED 4 PAINTED FIN15H
$" TNICK, 3 COAT CEMENT
PLASTER
VINYL (OR APPROVED
EQUAL) CORNER BEAD
VINYL (OR APPROVED EQUAL)
CA51NG BEAD
NOTE:
METAL LATH. LATH TO BE
PER FBC R103.1.1 / A5TM
C-84l-091 MIN. 2.5 L55. PER
SQ. YARD (UTILITY OR
NOMINAL LATH DOES NOT
MEET SPECIFICATIONS)
WOOD CONSTRUCTION
WEATHER RE515TIVE
BARRIER #1
WEATHER RE515TIVE
BARRIER #2
8" TNICK, 3 COAT CEMENT PLASTER
METAL LATH
WOOD SHEATHING
ADER/BEAM
4" POSITIVE DRAIN WEEP 5CREED
NO GAP IN FIELD
(SHOWN FOR CLARIFICATION OF
SEPARATE ACCESSORIES ONLY)
)DRIP EDGE INSTALLATION
1 1 tl 6CALEN.ib.
2x FRAMING MEMBER
$" THICK, 3 COAT CEMENT PLASTER
CORNER BEAD FASTENED TO
SHEATHING @ I" O.C. MAX.
WRB LAYER #I, 5TUCCOWRAP
(OR APPROVED EQUAL)
WOOD SHEATHING
METAL LATH
WRB LAYER #2, FORTIF15ER BUILDING
PAPER (OR APPROVED EQUAL)
CORNER BEAD @ FRAME
1(�ti SGALE: Nib.
CORNER BEAD
(FASTENER 8 SPACING -8 1" O.C.)
CMU
%' THICK, 3 COAT CEMENT PLASTER
APPLIED DIRECTLY TO CONCRETE
MA50NRY UNIT
I�CORNER BEAD @ BLOCK
1 �D SCALE: N.ib.
A R C H I T E C T S
Design
p
1 ®U Inc.
1441 N. RONALD REAGAN BLVD.
LONGWOOD, FL 32750
PH: 407-774-6078
FAX:407-774-4078
www.abdesigngroup.com
AA #: 0003325
�III'llllll
L
o0�omo�0��
E
8
ffi
E
0
`m
r
sUBDIV. 8e LOT:
OAKLAND
LAKE
LOT 13
MODEL:
1452
moo—oo
PROJECT#:
02784.000/00013
PAGE:
WALL
ASSEMBLY
DETAILS
160 MPH EXP. C
ARCHfTECT.
STATE OF FLORIDA
7/5/18
1 SC.ILE: 1/4' 1'-0" 1
SHE�ET� ��
V V A3
4�
WOOD SHEATHING
WRB LAYER #I, 5TUCCOWRAP
(OR APPROVED EQUAL)
WRB LAYER 12, FORTIF15ER
BUILDING PAPER (OR
APPROVED EQUAL)
METAL LATH
8" THICK, 3 COAT
CEMENT PLASTER
6"5ELF-ADHERING
FLASHING
DRIP CAP
WINDOW FLANGE
WRB LAYER #I, 5'
(OR APPRO1
WRB LAYER 12, FORTIFIBE
PAPER (OR APPROI
I,
8" TH
CEMEI`
(%" 5EL1:
WING�W FL-IWIlVl.�G
CASING BEAD C WINDOW
FRAME, NO BAND
13A bCALE, L
�TUCCOWRAP
) EQUAL)
dG
FORTIF15ER
R (OR
JAL)
T
:R
WOOD SHEATHING
WRB LAYER 01, 5TUCCOWRAP
(OR APPROVED EQUAL)
WRB LAYER 12, FORTIF15ER
BUILDING PAPER
WOOD SHEATHING
lOR APPROVED EQUAL) WRB LAYER 01, 5TUCCOWRAP
METAL LATH (OR APPROVED EQUAL)
8" THICK, 3 COAT CEMENT ' WRB LAYER #2, FORTIF15ER
PLASTER; BUILDING PAPER
VINYL (OR APPROVED EQUAL) (OR APPROVED EQUAL)
ANGLED CA51NG BEAD METAL LATH
6"5ELF-ADHERING FLASHING (ExPL°i7Ep a" THICK, 3 COAT
VIEW FOR CEMENT PLASTER
DRIP CAP CLARITY)
WINDOW FLANGE
WRB LAYER 111, 5TUCCOWRAP (OR APPROVED EQUAL)
VINYL (OR APPROVED EQUAL) ANGLED CASING BEAD
WRB LAYER #2, FORTIF15ER BUILDING
PAPER (OR APPROVED EQUAL)
METAL LATH
$" THICK, 3 COAT
CEMENT PLASTER
6 "5ELF-ADHERING
FLASHING
DRIP CAP
CASING BEAD C WINDOW WINDOW FLANGE
FRAME, W BAND
13B SCALE: N.T,S.
LEGEND
DRAINAGE PLANE
(WRB LAYER #I, 5TUCCOWRAP
OR APPROVED EQUAL)
WRB LAYER #2
(FORTIF15ER BUILDING PAPER
OR APPROVED EQUAL)
METAL LATH X X X X
5TUCC0
WOOD SHEATHING
5ELF-ADHE5IVE FLASHING
NOTE:
METAL LATH: LATH TO BE PER FBC R103.1.1 / A5TM
C-841-0191 MIN. 2.5 L55. PER 5Q. YARD (UTILITY OR
NOMINAL LATH DOES NOT MEET SPECIFICATIONS)
SEALANT CASING BEAD1 i0 WINDOW
WINDOW FRAME
WINDOW FLANGE
2X FRAMING MEMBER
BUILDING WRAP
1X TRIM MEMBER 6 STUCCO
TO 51DING TRANSITION
SIDING
$" THICK, 3 COAT CEMENT
Y: GAP' iYP PLASTER
CASING BEAD TO TRIM METAL LATH
WRB LAYER 12, FORTIF15ER
BUILDING PAPER
(OR APPROVED EQUAL)
WOOD SHEATHING
`—WRB LAYER 11, 5TUCCOWRAP
WRB LAYER #I, STUCCOWRAP (OR APPROVED EQUAL)
(OR APPROVED EQUAL) CA51NG BEAD
6" SELF ADHERING
FLASHING OR PEEL 4 STICK
SIDING TO STUCCO
CASING BEAD
1 t bGALE; NTS. (CR05S-SECTION)
WOOD 5HEATHING
METAL LATH
WRB LAYER 01, 5TUCCOWRAP
(OR APPROVED EQUAL)
WRB LAYER 12, FORTIF15ER BUILDING
PAPER (OR APPROVED EQUAL)
$" THICK, 3 COAT
CEMENT PLASTER
VINYL (OR APPROVED EQUAL)
ANGLED CA51NG BEAD
$" THICK, 3 COAT
CEMENT PLASTER
VINYL (OR APPROVED EQUAL)
CASING BEAD
WOOD SHEATHING
WRB LAYER #1, 5TUCCOWRAP
(OR APPROVED EQUAL)
WRB LAYER 12, FORTIF15ER
BUILDING PAPER
(OR APPROVED EQUAL)
METAL LATH
s" THICK, 3 COAT CEMENT
(EXPLODED PLASTER
VIEW FOR
CLARITY)
CASING BEAD C RAISED
BAND FRAME
1 J SCALE: N_T
METAL LATH \ /5EALANT
WRB LAYER 02, FORTIF15EIR BUILDING
PAPER (OR APPROVED EQUAL)
WOOD SHEATHING I
WINDOW FRAME
WRB LAYER #1, 5TUCCOWRAP
(OR APPROVED EQUAL)
KJ" WIDE PEEL & STICK
OVER FLANGE
E-Z BEAD VINYL 2X FRAMING
(OR APPROVED EQUAL) C,451NG MEMBER
(W/%8" FLEXIBLE PVC BACKER ROD
INCLUDED)
*APPLY FULL BED OF
— SEALANT BETWEEN —
FLANGE 4 BUILDING WRAP
jDEZ BEAD WINDOW CASING
SCALE: N.T,S.
8" THICK, 3 COAT CEMENT
PLASTER
METAL LATH
WRB LAYER #2, FORTIF15ER
BUILDING PAPER
(OR APPROVED EQUAL)
E-Z BEAD VINYL (OR
2 APPROVED EQUAL) CA51NG
(W/%s" FLEXIBLE PVC BACKER
ROD INCLUDED)
WRB LAYER #1, STUCCOWRAP
(OR APPROVED EQUAL),
WRAPPED AROUND FRAMING
MEMBER /
6" 5ELF ADHERING FLASHING
WOOD SHEATHING
DETAIL EXPLODED FOR
CLARITY
A R C H I T E C T S
144a N. KV14ALU K" k AN ULVU.
LONGWOOD, FL 32750
PH: 407-774-6078
FAX:407-774-4078
www.abdesigngroup.com
AA #: 0003325
J
SUBDIV. 8e LOT:
OAKLAND
LAKE
LOT 13
MO DEL:
1452
moo—oo
PROJECT#:
02784.000/00013
PAGE:
WALL
ASSEMBLY
DETAILS
160 MPH EXP. C
AR T-
STATE OF FLORIDA
DATE; 7 /5 /18
SCALE: 1/4"-l'-O" 1
SHE�ET� ��
V V A4
4�
4'
CUT HOUSEWRAP AT
450 ANGLE
MODIFIED "I" CUT IN
HOUSEWRAP
LINE OF WINDOW OPENING
APPROVED HOUSEWRAP
OVER SHEATHING OVER WD
STUD WALL
STEP 1
WINDOW FLASHING
INSTALLATION DETAILS
FULL WRAP
u SCALE: NTS. (FRAME)
APPLY OSI H2U (OR
EQUAL) SEALANT •
WINDOWICMU JOINT.
FLUID APPLIED
FLASHING (LANCO
WHITE -SEAL RC-865
OR EQUAL).
SLOPE SILL
TO EXTERIOR
WALL FLASH
DETAIL
18A SCALE: NTS.
TG INSTALLATION
MASONRY)
TEMPORARILY c^' n_I IC
SECURE HOU:
IF UNDE
FOLD
IN AT J,
SLOPE
INSTALL (o" SELF -ADHERING
FLASHING OVER NAILING
FLANGE AT JAMBS
EXTEND FLASHING MIN I"
BELOW SILL FLEXIBLE
FLASHING
DO NOT SEAL BOTTOM FIN
ALIGN FLEXIBLE
SELF -ADHERING
�5HING W/ INT. EDGE
OF SILL R.O.
MECHANICALLY
FASTEN FANNED
-DGES. (CAP NAILS,
STAPLES)
STEP 2 INSTALL SELF -ADHERING
FLEXIBLE FLASHING AS THE
FLASHING AT THE SILL
L)rhF u
NOTE:
1. IT IS THE CONTACTORS RESPONSIBILTY
TO VERIFY THE COMPATIBILITY OF ALL
PRODUCTS INCLUDING HOUSEWRAP,
SEALANTS 4 SELF -ADHERING FLASHING
MATERIALS USED DURING
CONSTRUCTION.
(0" SELF -ADHERING
R OVER VINYL HEAD
IG (WITH END DAMS)
NAILING FLANGE
EXTEND
SELF -ADHERING
FLASHING I" MIN
BEYOND JAMB
FLASHING
INSTALL VINYL
DRIP CAP
APPLY 3i$" NOM, CONTINUOUS
BEAD OF SEALANT AT JAMBS
AND HEAD or APPLY TO BACK
OF WINDOW NAILING FLANGE IN
LINE W/ PRE -PUNCHED HOLES
OR SLOTS.
SUPER STRETCH
BUTYL FLASHING
STEP 3 L-a" VERT. END
DAMS REQ'D. AT
EACH END OF SILL.
011:1 1
MIN. TEXTURED
EMENTITIOUS COATING
VER BLOCK
J6EWRAP DOWN 4
DIAGONAL CUT 8
HEAD OF WINDOW
" MIN. TEXTURED
)EMENTITIOUS COATING
)VER BLOCK
STEP 4
01 ri r u
INSTALL A SILL DAM OVER THE
BUILDING WRAP AT THE BACK OR
THE SILL AND THEN INSTALL THE
SELF -ADHERING STRETCHABLE
FLASHING 4 APPLY SEALANT AT
ENDS OF SILL DAM
INSTALL WINDOW PLL
LEVEL AND SQUARE f
MANUFACTURERS WRIT
INSTRUCTI
APPLY MEMBRANE
FLASHING OVER JOINT
(," WIDE ADHESIVE
:LEXIBLE FLASHING
:R DRIP CAP JOINT
:TO -WRAP 5T-20XL
APPROVED EQUAL)
MIN. TEXTURED
EMENTITIOUS COATING
,VER FRAME
STEP 5
U 11J1 V
MIN. TEXTURED
EMENTITIOUS COATING
,VER FRAME
2. INSTALL ALL MATERIALS PER
MANUFACTURERS WRITTEN STUCCO OVER BLOCK STUCCO OVER BLOCK STUCCO OVER FRAME STUCCO OVER FRAME
SPECIFICATIONS 4 WARRANTY (MIN. THICKNESS") (MIN. THICKNESS e") (MIN. THICKNESS e") (MIN. THICKNESS e")
REQUIREMENTS. SIDING LOOK
SIDING LOOK
ORLANDO/TAMPA ORLANDO/TAMPA
WARNING: SEALANTS AND SELF ADHERED S. FLORIDA S. FLORIDA S. FLORIDA S. FLORIDA
FLASHING MAY REACT ADVERSELY IF NOT
COMPATIBLE,
MINIMUM STUCCO THICKNESS
19 WALE: N.TA
NOTE:
SEAL INTERIOR PERIMETER OF WINDOW
WITH SEALANT
A R C H I T E C T S
Design
1 oU ifinc.
1441 N. RONALD REAGAN BLVD.
LONGWOOD, FL 32750
PH: 407-774-6078
FAX:407-7744078
www.abdesigngroup.com
AA #: 0003325
r
1
�I"IIII"'
o�v000mom�
E
8
N
E
O
L
L
SUBDIV. & LOT:
OAKLAND
LAKE
LOT 13
MODEL:
1452
XXx00— 00
PROJECT#:
02784.000/00013
PAGE:
WALL
ASSEMBLY
DETAILS
160 MPH EXP. C
ARCHrrECT-
STATE OF FLORIDA
DAT G 7/b/18 1
SC :1/4"=1'-0"