Loading...
HomeMy WebLinkAboutBUILDING PLANS PAGE 16-23TOP PLATE IIN-' O.C. MAX. SECURE 2X4 W/ 2-1/4'- TAPGON6 OR DRIVE PIN (MIN. SHANK SIZE J45 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4' EA. END NOT TO EUV 2X4 801_ID ING SECURE T ATPING WITH MIN d PER BLK EA. END *NOTE.- NAIL SkEATNING TO ALL 2X AS PER EXT. SkEATkINGx NAILING, 8d 4" O.G. MAX 6 EC)GES 8 6"-6' O.C. MAX IN THE 1=IELD OMNI 13 a I —mill I 2X4 SECURED TO GABLE ENG W/(2A 6"-8" O.C. i UPRIGHT B"'v. 04.411 M IL I I • > • • . III MIA • ♦ 1 1 . . • 1 I ■ �: • is • •' • , i SP4032' MSTA-36 32' MAX 6P4*32' O.C. AX- TRUSS TO WOOD FRAMING SIMPSON MTS-12 PRE -ENO. TRUSS DO TOP LATE 2 T STRESS 125L. 2X TOP PLATE i I ID WALL ^2 7/16' 8 8 16' O.C. MAX, OR 1/16' ZIP SHEATHING N N SYSTEM (INSTALLED PER MAN 4 SUBFLOOR GLUED 2XX BLOCKING o CREWED AS PER TOP of A ER SCHEDULE 1/2' CDX I FLOOR STUDS TO FLOOR STUDS 2X STUDS 16' O.G. MAX. = w SIMPSON META-36 0 32' 2X 57M. PLATS O.G. MAX 3/4' FLOOR DECKING PRE- ENGINEERED FLOOR GIRDER PRE -ENO FLOOR TRUSS DOUBLE TOP PLATE PRE- ENGINEER-ED FLOCK TRUSS 2x CONTNNOUS STRESS LOCKING MID WALL Q CONTINUOUS SHEATHING TO BEGIN AT TOP OF BLK - 2 STUDS • 16' O.G. MAX, W/ 114' GAP FROM BLK. TO O.S.B. U.O —In' I1�. BD. �2 HORIZONTAL 2X 5-F. STRUCTURAL ]BLOCKING AT SECU BT. PLATS TO PERJMETER CF OBB. t0 PROVIDE CONT. NAIL PATTERN SLAB W 'xS' ANCHOR O3 REMAINING AREA TO BE SHEATHED PROM DBL. TOP BOLT W/ WASHER SET IN PLATE TO HORIZONTAL BLOCKING. SIMPSON STRENGTH EPDXY i' D. MIN. ® SHEATHING • TOP OF WOOD FRAMED WALL TO BE STAGGERED MIN. OF 16' FROM SHEET BELOW SP SIMPSON 4 32' O.C. MAX ® INS-rALL ALL sPEETB W/FACE GRAM PARALLEL TO STUDS 2—STORY L.B. EXT. WALL SHEATHING SCALE: I n' = I'-0' SCALE: PER �DOr/\ WINDOW OPENING TYP. EXTERIOR WINDOW/ DOOR OPENING WD FRAM ® -J/ o SECURE 2x4 ON FLAT TO BLK W/ CUT NAILS. SIDES: 2X6 GARAGE DOOR BUCK W/ (5) M'X8' A -BOLTS 4" EMBEDMENT MIN Rd W/ 21IX2'>(% WASHER AND NUT SPACED EVENLY FROM FLOOR TO GARAGE DOOR HDR IN JOINTS PRIOR TO FILLING. 1-2X6 PT BLOCK ® CENTER OF DOOR HEADER W/(UJ�'X8" J-BOLTS 19 ® 4" AND NUT. EMBEDMENT W/ 2'X2'XYa' WASHER INotES: � � C ALL ANCHORS SHALL BE IN ACCORDANCE t0 MANUFACTURER'S INSTALLATION INSTRUCTIONS WHERE SUCH INSTRUCTIONS ARE MORE STRINGENT GARAGE DOOR %1 BUCK ATTACHMENT v SCALE: 1/2' t OPENING a Q a q d o PRECAST LINTEL a d" �r ` d d TO SECURE M ED MIN k1i L THAN I I ', WIND T E a SE TO L CK a d a 4 LOCKS d T BLOCK W/ (2) x3" ON OR DRIVE PIN l N ANK SIZ 145) ( MBED. 1 T IN 8' OF EACH D AND 1 OG. MAX SPACI GMU W L 1 a a a 4 4 ` d 4 a - 4 _a a d C a a d n d Q Q p d d a q.. d a n` d' d a a 9 tl ARCH WINDOW FRAME SCALE: 3/4" =1'-0" PRE-£NG TRUSSES W/ TRUSS CONNECTOR VERIFY W/ FRAMING PLAN DOUBLE TOP PLATE CRIPPLE STUps a SrPSON L12 o EA. JACK � TUD, BOT IDES OF OPENING/ 2x 5T S 6 16' O.G. MAX W/ SP PING. SHEATHING TO BE PIN J' OF WINDOW/ DOOR ENING AND SECURE PER NAILING SCHEDULE KING STUDS (SEE HEADER SPAN CHART FOR DETAILS AND SPECIFICATION) JACKS (SEE HEADER SPAN CHART FOR DETAILS AND SPECIFICATION) JACK STUD ASSEMBLY TO BE SECURED ONE PLY ® A TIME. SE 12d NAILS, TWO WITHIN r EACP SND t NO MORE TH 12' O.C. STAGGERED SP4 145 a TOP AND BOTT LATES s EA. FULL LENGTH 8 D, BOTH SIDES OF OPENI SHEATHING T AP TO BOTTOM of NG'D TRUSS BELOW- SH THING MUST NOT BREAK 1'- MIN. FROM 2ND FLR LINE. -ENG TRUSSES OR FRAMED RAFTERS 0.8.5. SPEAT OR CDX PLYWOOD. T PER FASTENER CHE I. OR 1/16' ZI SHE E141 T SYSTEM ( I MANUR 5 2x4 DE STU SCURF BETWEEN 6 BAYS W/ (3) 12d' 2x DOUB TOP ACP END PLATE UPS a 16' O.G. 2 o EVER STUD 2X4 Bt. PLATE DORMER ATTACHMENT 15 SCALE: In"=1'-0' 2x RIDGE ONE SI RGER THAN RAFTS 12E MIN. (3) 12d NAILS MIN. (4) 10d GUN NAILS 2x4 COLLAR TIE AT EVERY OTHER RAFTER W/ MIN. (3) 12d NAILS OR MIN. (4) 10d GUN NAILS 2x RAFTERS No NAILER SECURE TO TRUSSES BELOW W/ (2) 12d NAILS OR (3) 10d GUN NAILS s EA. TRUSS RAFTER t0 TRUSS MTS-12 CREATE VOID FOR STRAP PENETRATION ROOF DECKING OVER PRE -ENG TRUSSES PRE-ENG. TRUSS HEADER SIZE PER SPAN CHART. Nei TYP. INTERIOR DOOR OPENING WD 11 SCALE:I/2'=1'-O' *5 REBAR VERT. IN SOLID GROUTED CELL 19/8' THICK, 3 COAT CEMENr PLAsTBR APPLIED DIRECTLY TO MASONRY GALV.8TEEL TRACK BRACKETS FASTENED TO WOOD JAMB W/ 3/16'x1 1/4' LAG GALV. STEEL SCREWS VERTICAL TRACK BY MAUF. FASTENED rO TRACK BRACKETS WV 1/4'-20X1/2' CARRIAGE BOLTS AND LOCK NUTS. PRE-ENCsI� MTS-12 MTS-12 3/W) �A CONV. FRAMED ROOF SCALE: I n' - I' -O' PRE-ENG TRUSSES W/TRUSS CONNECTOR VERIFY W/ FRAMING PLAN -VOUBLE TOP PLATE CRIPPLE STUDS Zoz..KMAX SIMPSON LSTA-IZb*ftBOTH 51 lipPE NG. 2 a 16' O.C. MAX W/ PING. SHEATHING TO BE PIN }' OF WINDOW/ DOOR OPENING AND SECURE PER NAILING SCHEDULE KING STUDS (SEE HEADER 5PAN CHART FOR DETAILS AND SPECIFICATION) -JACKS (SEE HEADER SPAN CHART FOR DETAILS AND SPECIFICATION) CK STUD ASSEMBLY t0 BE RED ONE PLY a A TIME. USE NAILS, Tu WITHN 6' FROM E END < NO MORE THAN 12' O. . TTGGERED In'x9' A.B. MIN,T' EMBEDMENMT 8" F GP -END E 32' O.G. MAX. SP4 OR H5 • TOP AND BOTTOM PLATES • EA. FULL LENGTH STUD, BOTH SIDES OF OPENING. LINE OF SLAB CORNER BEAD SEALANT t BACKER ROD 8' CMU SEE STRUCTURAL FOR REINFORCEMENT 2x6 P.T. WD ATtACI-ED TO FILL CELL AS PER PRODUCT SPPROVAL Rea. FROM MIAMI-DADS COUNTY WEATHER STRIP MOULDING ALL AROUND(8Y DOOR MANUFJ OVERHEAD DOOR BY OTHERS GARAGE DOOR JAMBS SCALE: In'=1'-0° 2X4 DBL. TOP PLATE ?X4 STUDS 16' I/16" OS$. TEXT. FINISH META-16 �<7Mu WALL " II15 UPLIFT SIMPSOM PTSM20 W/10 10d r0 TRUSS AND (4) 1/4' x 2 1/4' TAPCONS TO CONT POURED LINTEL M 1900 UPLIFT (2) SIMPSOM HTSM20 INSTALLED ON OPPOSITE FACES OF BLOCK WALL W/10 10d TO TRUSS AND (4) 1/4' x 2 1/4' TAPCOI6 TO CONT -POURED LINTEL PRE -ENO TRUSS /� CONTINUOUS / BOND BEAM TRUSS ANCHOR 12 RETROFIT N.T.S. CONTROL DATE: 07/01/15 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 W 99 W 0 0. U W A F A h BVHDIV. at LOT: CREEKSIDE LOT 63 PROJECT# 04321.000 063R1 �ODzzA 4EAB "1672-ARIA" GARAGE ®'RING: LEFT PAGE: MISC. DETAILS t60 MPH EXP. C ARCHITECT: STATE OF FLORIDA PRINT 06/06/18 DATE: ECALIM 1/4"=1'-0" �9HEET 1 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 M W U W 0 F 0. v W Q F A I E: �9VHDiV. dt LOT: CREEKSIDE LOT 63 PROJECT# 04321.000 063R1 MODEL: 4EAB "1672- ARIA" GARAGE 8MMG: LEFT PAGE: PRODUCT APPROVALS t60 MPH EXP, C ARCHITECT- STATE OF FLORIDA AN R . AN BCALE: 1/4"=1'-0" 1 NOTE- NOTE: IF ZIP S�-IEATI-IINCs SYSTEM IS APPROVED BUILDING WRAP IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE SHALL BE LAPPED A MINIMUM OF INSTALLED, PLEASE SEE 4'x4" SELF -ADHERING MEMBRANE 6 ° MANUFACTURERS b" 9 VERTICAL LAPS (ROLL MANUFACTURERS FLASHING (COMPATIBLE W/ HOUSE �w ENDS) 4 6' 40 HORIZONTAL LAPS. WRAP MATERIAL) OVER INSTALLATION PROCEDURES ALL SEAMS NEED TO BE TAPED LATH VERTICAL LAP TO BE In INSTALLATION PROCEDURES APPROVED HOUSE WRAP. WITH FORTIBER SHEATHING TAPE FLASHING TO EXTEND ONTO PIPE In OR LESS PIPE b'xb' SELF -ADHERING MEMBRANE PREFORMED CONTROL JOINT �° THICK, 3 COAT CEMENT PENETRATION FLASHING (COMPATIBLE W/ HOUSE ' WRAP MATERIAL) OVER 4'x4' FLANGE OF CONTROL JOINTS t '� \ PLASTER / \ SELF -ADHERING MEMBRANE BE WIRED TIED t0 LATH OW WIC LAYER 02, FORTIFIBER FLASHING OVER APPROVED O.C. MAX (VERTA NOTE; DO BUILDING PAPER I° MN. LAP q METAL LATH HOUSE WRAP. NOT FASTEN CONTROL JOINT TO / \ FLASHING TO EXPEND ONTO PIPE WALL EVEN IF STUD EXISTS BEYOND EXCEPT STAPLES W/ APPROVED METAL LATH W LEG MAY BE USED TO TEMP. FASTENED •-I' (VERT.) O.G. MAX X X X I SECURE CONTROL JOINT AT SUPPORTS X X X — DURING INSTALLATION CURB LAYER 09 GUT AND OVERLAP ONE SIDE OF • O.G. MAX VERTICALLY METAL LATH 6ELF-ADµERING MEMBRtWE FASTENERS TO BE 9PAGED STUCCO WRAP pH I FLASHING CUT CUT AND OVERLAP ONE SIDE OF SEL WOOD SHEATHING / `STEP "1`�' TEP *2 FLASHING EKING MEMBRANE I OR i/16' ZIP BHEATHINCs ' � WR$ LAYER 41, in CHICK, 3 COAT CEMENT44, SYSTEM 1INStALLED PER �� STUCCO WRAP PLASTER STUWRICCO LAYER P MANQF 6. CS.) METAL LATH STUCCO WRAP 6" MIN PAPER LAP BELOW ONLI' / WRB LAYER n, FORTFIBER WRS LAYER 02, FOR1'IFIBER WRB LAYER 02, FORTIF15ER BUILDING PAPER BUILDING PAPER BUILDING PAPER METAL LATH �\ STUCCDYER 01, WRAP 6°xb' SELF -ADHERING MEMBRANE FLASHING OVER 4'x4' SELF -ADHERING MEMBRANE e" TO i' INSTALL FASTENERS (CLIPS, FLASHING OVER APPROVED SAP rliN. WOOD SHEATHING STRAPS, STAPLES) AS - HOUSE WRAP. LATH 614ALL NOT E CONTINUOUS CONTROL 6'MIN. a. ~ w a � MYST EM SP1 CSC (INSTALLED (PER OR 1/16' ZIP NG REQUIRED TO SECURE FLASHING TO EXTEND ONTO PIPE JOINTS BUt SHALL PIPE/ WIRE TO FRAMING :rt v.A 4 rn . 4'x4' SELF -ADHERING MEMBRANE BE STOPPED AND FLASHING OVER AWED HOUSE WRAP. TIED AT EACH SIDE. PROVIDE 2X4 BLOCKING r t 4 LArN FLASHING t0 EXTEND t0 PIPE PER ASTM G1063 PLACED FLAT MAX b' 70 e' Z LAAPLL LAP R 1.10.1.4 FROM CONTROL JOINT WHEN CONTROL JOINT FALLS ON 2 APER LAP V CONT. BEAD OF SEALANT NT '— \ l STRUCTURAL STUD SCALE: 1 I. FASTENERS FOR LATH TO BE NAILS OR INSTALL APPROVED HOUSEWRAP AIR STAPLES IN COMPLIANCE W/ ASTM C1063 INFILTRATION BARRIER OVER 2. WIRE TIES TO BE (NO. IS) 0.0416' WIRE / SHEATHING 3. BLOCKING SHOWN MAY BE IN ADPITI \ t0 WALL STUDS REQUIRED PER PLAN ELASTOMERIC COATING OVER STUCCO/ - G.V. FINISH (SEE tYi' WALL SECTION) ;,•:",1 ". , . Ih 'max �1 .. t �: VERTICAL LATH & PAPER DETAIL \� WOOD STUDS 1 SECTION PER SECTION R703.7 a 4I Exterior lathing and plastering Nam: SHEATHING Exterior use of portland cement plaster SIDE LADS OF METAL OR 7/16' ZIP SHEATHING 9T91EM shall comply with the application PLASTER BASES SHALL !INSTALLED PER MANUF. SPECS.) " requirements of ASTM C 926-12A. BE SECURED TO BUILDING NOTE: „ „ FRAMING MEMBERS. PAPER k 6�AP IF ZIP SHEATHING SYSTEM IS nstallationofexterior lathing and framing �\ INSTALLED, PLEASE SEE 1 shall comp M TYPE CONTROL JOINT THEY SHALL ly with ASTM BET'II�EN SUPP_ C 1063-12A. p TIED ORTS WITH 0.041S-IN. (1.21-MM) STUCCO X• LAP ® LATH MANUFACTURERS WIRE AT INTERVALS NOT 4 3" LAP m PAPER INSTALLATION PROCEDURES MORE THAN S' (2213-MM). AS PER ASTM C1063 :j[' O I. FOLD INUTARD • Pr. A O I. FOLD INWARD • PT. A tal. 3 ,� F I F F N T R A T I O N D TAIL (f f; A 1"C 2 2. CREASE s Pr. B NOTE: C ®F° ° ® 4 K�C JKO UT FOR REPAIR OF TEARS HORIZONTAL LATHIN LAYERS, N.�.�.J. DETAIL MAYBE PATCHED ARS & PAPER DETAIL W/HOUSE WRAP TAPE PER MANUF. SPEC. OR FoLD PEEL 4 STICK • 4b- 1/16" ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS.) OR I. FOLD INWARD , ( a I. FOLD MWARD • F'r. A (WOOD SHEATHING OR CMU �J PT.A / 2. cREA9E • Pr.6 2. cREasr= • Pr. $ LURB LAYER 01, 3. cWASE • Pr. c STUCCO LJRAP (FRAME ONLY) 3. CREASE s PT. C 4. FOLD FT. C OVER Pr. D TILL PT. C TOUGdEB I ®" THICK, 3 COAT CEMENT ® PLASTER(FRAME), 1/2a 2 COAT I CEMENT PLASTER (CMU) LEGENij METAL LATH (FRAME ONLY) ��� ® LAP LURE E TAPE OVER DRAINAGtE FLANS (WR5 ItIATER TIGHT Root=/wALL scRED . TT• ®orrcr, FLAtYaE NOTE: SEAL. FOLD, 22 IF ZIP SHEATHING SYSTEM IS tl4T WT. INSTALLED, PLEASE SEE d' THICK 3 pp4r CEMENT z $'XSII IIL® TYPE CONTINUOUS WR5 LA R *`2 (FORT IF 15ER — — — — — — PLASTER ("UMW V2' 2 COAT GAL V. METAL FLASHING MANUFACTURERS CMIMT PLASTER (CM) INSTALLATION PROCEDURES WRBLAYER •2 FORTIFIBER (NAIL TO ROOF DECK, NOT 5L1 ILD INS FAFER) BUILDINGPAPERtFWIEONLY) WALL SHEATHING) WRBLAYIE CAP SHINGLE - DO NOT NAIL, 1`IETAL LATi 4 X X X X STUCCO WRAPOWAME ONLrJ INSTALL IUITH ROOF CEMENT LAP LAYERS OK Iiii u)wP -Z Vcm rwlurRa rLc...r, WIWI eu NW EE 8(FROIME Vr OILY / /�f`� I I (/^� a- S T STUCCO C 0 b ®.� W Vt V . FRArac OR CM �xr� .n iwll All �I I LLIIICCI') — � y ROOF CEMENT •„£ US61ALLFLASHWG Gm ROOF PER ELEVATIONS WOOD Ji ,�Ti- INC /. = o OR 116 ZIP SI-E ATNIN E G SZ'ST EM a KCK-OUTFLASHIN e6M ( (INSTALLED PER MANU1=. SPECS.) DETMU SELF-AD�ESIV FL�AS�ING — — NOTE- F ZIP SHEATHING SYSTEM IS NOTE: INSTALLED, PLEASE SEE MANUFACTURERS 1*vIETAL LA4T�4: LATE TO 8E i=ER SECTION FM-* UNIPMArIMT-- _ ,F ct� — wareR TruT SEAL (aaD OR �EKDONarcut INSTALLATION PROCEDURES R��3.�.1 / ,�,STI„� C-Bpi 1"11N, 2.5 LBS, 814t LE ROOFMG / IWA�ING ATE Krrr 6 OF ROOF 4 Ff=-iR SQ. TARO (U'TIL ITN' OR N01"rINAL DRIP EDGE( OAP 3' EXTEND U21 le -all %eATt-HNC, MFCF-ANICALLY FASTEN 4' Or- MAX , FASCIA WRAP r� L' FLAS SIN ILA' t j�}}—.. 1y.�� /� 1 D O E 5 NOT 1� E E I S E C 1 I I C /A T ION S N.T.S. •1 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 r � �1'II'1 S'CTHDm da LOT: CREEKSIDE LOT 63 PltOJZCT# 04321.000 063R1 MODIC : 4EAB "1672— ARIA" GABAGE SIMMO: LEFT PAGE: WALL ASSEMBLY DETAILS t60 MPH EXR C ARCHITECT - STATE OF FLORIDA 3181 ape; 06/06/18 ®CALF: 1/4f1=1'-0" r 8:" : % NOTE: INSTALL 6" SEL4:-AP14 IF ZIP 5I I T14ING SYSTEM I5 MEMBRANE FLA INSTALLED, LEASE SEE TOP, SIDE(S) ANMANU1=ACtUR RSFLANGES OE NOINSTALLATIONROCEDURE5 FRAME OF THE S QU NG of FI. BOTTOM 2. SID X VENT IS BE SET IN BED X OF AL T T TOP AND SI SEALANT IS TO BE T L AS TO DEFLECT AT FROM JOINTS. E- AD ALL AROUND N APPLY SEALANT ALL i X T5 AND INTERSECTIONS PLY SEALANT AT PERIMETER OF BACKER ROD ti ON -MOVABLE FRAME AND STUCCO 1 ON ALL SIDES, Y4" CAULKING a JOINT ALL AROUND PER SECTION R703.7 Exterior lathing and plastering Exterior use of portland cement plaster BACKER ROD shall comply with the application X requirements of ASTM C 926-12A. In Ilation of exterior lathing and framing X she] mply with ASTM C 1063-12A. WRB LAYER "I, STUCCO WRAP NODDED YE T X' THICK, 3 COA EMENT ' X' PLAS4ER METAb. LATH WRB LAYER *2, FORTIPI R BUILDINGS PAPER WOOD SHEATHINCs A DRYER VENT (FRAME), 8' CMU rIN5TALLED MR MANUF. 5 C5J OR WOOD SHEATHINGS WRB LAYER "I, STUCCO WRAP -WRB LAYER FORTIPISER BUIj,�NCx P R LATH - V YL CA51NCa BEAD 6' RAISEp BAND -Yal ToX11 MID -WALL WEEP SCREEL W WIDE STRIP SELF ADHESIVE FL-ASHIWz, GLEAN MASONRY BEFORE APPLYING Z FLASHING OVER 6CRATC44 COAT I7ZONTAL WEEP SCR` W/STONE VENEER (FRAME TO BLOCK H ]LEGEND DRAINAGE PLANE (LUR3 LATER 01, STUCCO L1RAP) WRB LAYER *2 (FORTII=IBER - - - - - 5UILDING PAP1=R) METAL LATH X--x—x—x STUCCO � " LUCOD 5HEAT4NG OR 7/16" ZIP SHEATHINGS SYSTEM ( INSTALLED PER MANUF. SPECS.) SELF-ADHESIVE FLA54NG - — — — NOTE: METAL LATH: LATH TO SE PER SECTION R103.1.1 / ASTM G-541-09, MIN. 2.5 LSS. PER ea. `WARD (UTILITY OR NO INAL LATH DOES NOT MEET SPECIFICATIONS) BUILDINGS PAPER OVER "QUICK FLASI-4" PIPE T14ROUCcH — WALL I 6" SELF ADHESIVE — FLASHING (INSTALL PER MANUF. SPECS.) BUILDINGS PAPER — UNDER 'QUICK FLASH" ELEC. METED VERIFY LO STUCCO FINISH ro" SELF ADHESIVE OVER TOP E SIDES SELF FLASHING UNIT PREMANUF. DRYER VENT CAP (SET IN CONT. SEALANT) SEALANT a TOP E SIDS=$ fl- 1 / NOTE: IF ZIP SHEATHING SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES A VENT PENETRATION SCALE: N.T.S. ,y1'<=H Iv 1'CMLI=Iym STUCCO SCRATCH COAT 4 1 COAT OF PAINT W/BACK- ROLL PRIOR TO ELEC. METER INSTALLATION METER FIELD =Y LOCATION WOOD CONSTRUCT! 1/16' ZIP SPEATI I SY EM (INSTALLED PER MANSPEGSJ OR WOOD 51-IEATI41 IS :R n, FORTIFIBER PAPER tl-41GK, 3 COAT CEMENT ASTER TO Ys" �-- 0 SE L D \ FLASH41NCx WOOD FRA WALL AL WEEP SC FRAME TO FRAME) NOTE: IF ZIP SHEATHING SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES ML Y STUCCO SCRATCH COAT AND ONE (1) LAYER OF PAINT PRIOR TO INSTALLING ELEC. METER CAVITY TO BE FILLED WITH RIGID POLYMERIC 15OCYANOTE-POLY5LEND FOAM nt Gtl ILt" 7R SIMILAR) APPLY A SILICON BASE SEALANT AT POINT THAT ELEC. WIRE PENETRATES �O SCRATCH COAT LARGER THAN THE ELEC. METER CAN OR METER CAN COMBO OR METER CAN AND DISCONNECT O ELECTRICAL CONDUIT PENETRATION CUT OPENINGS IN APPROVED HOUSEWRAP FOR BOX INSTALLATION WRB LAYER *1, STUCCO WRAP WOOD SHEATHING APPROVED HOUSEWRAP BELOW CUT SUCH THA' NO MEMBRANE ENTERS BOX, APPLY TO FA( EDGE APPLY E-Z 5EA1 OVER 60 MIN GRADE "D" FELT -PROVIDE SEALANT AT ALL JOINT5 AND INTERSECTIONS '1/16' ZIP S4EATHING SYSTEM (INSTALLED PER MANUF. SPECS.) OR OD SHEATHING [WO WRB LAYER M, 1. STUCCO WRAP WRB LAYER 02, FORTIFIBER BUILDINCs PAPER METAL LATH WOOD CONSTRUCTION 1/8" TEXTURED /FINISH a WOOD FASTEN TO WOOD STRUCTURAL MEMBER O i" O.G. MAX e' CMU 1. Ya' TO X5' MID -WALL =,y' i WEEP SCREED - zQ Y1 V WIDE STRIP SELF AD44E51VE PLASHING, GLEAN MASONRY BEFORE APPLYING FINISH * MASONRY B HORIZONTAL WEEP SCREED (FRAME TO BLOCK) &T F 1 &TEi= #3 1•q•q•O.9 •e•O.O q 0 0• •O O 0• .o O O• 0 0� .e.o•o 0 NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WRB LAYER *I, STUCCO WRAP CUT "X" INTO SELF -ADHERING MEMBRANE FLASHING APPLY SELF -ADHERING MEMBRANE FLASHING OVER BOX AND OVER APPROVED WRBLATER *I 5Tf' �2 WRB LAYER *I, STUCCO WRAP APPLY 60 MIN SELF-ADHERINGS GRADE 'D' FELT MEMBRANE FLASHING OVER El SELF -ADHERING FLASHING OVER APROVEDJe -LJ HOUSEWRAP WRB LAYER *2, F-ORTIF15ER BUILDING PAPER 57 f= '* ELASTOMERIC COATINGS OVER STUCCO/ C.V. FINISH (SEE TYPICAL WALL SECTION) METAL LATH SfiEP Sfir=P #ro OELECTRICAL RECEPTACLE 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com lIIIIII AA #: 0003325 J F w U W D q eusioIY. ae LOT: CREEKSIDE LOT 63 P'itOJzCT�(i 04321.000 063R1 MODML: 4EAB "1672- ARIA" GAZU010 BW MG: LEFT PAGIC: WALL ASSEMBLY DETAILS 160 MPH EXR C ARCHITECT: STATE OF FLORIDA JL11\1 117 1" DRMT A 06/06/18 BCALM 1/4f1=11-01' 8HRIET 1 WOOD SHEATHING WOOD CONSTRUCTION 3/4' HAT CHANNE W/S/e° TYPE "X' WOOD SHEATHING WRB LAYER "I, STUCCO WRAP ' THICK, 3 GOAT CEMENT PLASTER WRB LAYER el, STUCCO WRAP AMIGO AM6fo-WFWC-1S0 CUSTOM CASING BEAD (SHOWN FO CLARIFICATION OF SEPARAT AGGESSORIES ONLY) ASING BEAD 10A DTL. C� CANT. SCALE: I I/2 I'-0° WRB LAYER "I, STUCCO WRAP WRB LAYER 02, -OR ER BUILDING PAPER " THICK, 3 COAT I" LENT PLASTER 6' SAP. a TOP WEEP SCREED TO SHk�ING EHIND WEEP SCREED 6' SELF-ADHEREING FLASHING WRAPPED TOP OF WEEP SCREED TO SHEATHING BELOW _ WRB LAYER el, STUCCO WRAP 1 i— WRB LAYER 02, FORTING BUILDING PAPER a r �— 6' SELF—ADHEREING FLASHING WRAPPED 0 CORNER OF CANTILEVER 2u NOTE: IF ZIP SkFATHIN INSTALLED, PLEA MANUFACTURERS INSTALLATION PF EXT. FRAMED WALL PRE-ENG'D SS '�` TTlT7T77?rTl X---�� WEATHER RE515 I BARRIER WEATHER RESISTIVE BARRIER 02 P THICK, 3 GOAT CEMEN y RIESAl, , PLASTER Y METAL LATH WOOD SHEATHING EXTERIOR GRADE DRY WALL 4° POSITIVE DRAIN THICK, 3 COAL CEME WEEP SCREED PA PLASTER VINYL CORNER BEAD N FI VINYL CASING BEAD (SHOWN FOR I ATION OF SEPARATE ACC IES ONLY) 10 CANTILEVER DR STEM IS EDGE SEE = uRES L E G E N NOTE: 1„IETAL LATE: LATE TO 5E Pf=1R SCTI 2.� S. PER SCE. %TI ARD (UTILITi' OR Nor"l AL L 1DO S NOT 1"IE T S rCi l ATIO is) NOTE: IF ZIP SHEAT ING SY IS INSTALLED, EASE E MANUFACTU RS INSTALLATION PR L RES OD CONSTRUCTION WEATHER RESISTIVE BARRIER MI 3/4 RESILI T WEATHER RESISTIVE HAT CHANNEL BARRIER N2 VINYL CAS Ap I' I J' THICK 3 COAT CEMENT PLASTER 5/8' TYRE WALL METAL LATH COAT CEMENT VINYL CASING BEAD 11D DRIP EDGE INSTALLATION IF ZIP SHE14THINGS S EM IS INSTALLEp, PLIEEA51E SEE MANUFACTURERS INSTALLATION PROCEDURES 5/8' TYPE 'X" DRYWALL W/TEXTURED 4 PAINTED FINISH " THICK, 3 COAT CEMENT PLASTER VINYL CORNER BEAD VINYL CASING BEAD NO GAP IN FIELD (SHOWN FOR CLARIFCATI OF SEPARATE ACCESSORIES O 1 WOOD CONSTRUCITON WEATHER RESISTIVE a3ARRIER M WEATHER RESISTIVE OARRIER "2 " THICK, 3 COAT CEMENT PLASTER METAL LATH 2PANLP. GCS-) VINYL GORP 4' POSITIVE DRAIN WEEP SCREED NO GAP IN FIELD (SHOWN FOR CLARIFICATION OF SEPARATE ACCESSORIES ONLY) DRAINAGE FLANS (WRB LAYER *I, STUCCO WRAP) WRB LATER #2 (r=ORT11-1k ER PUILDING PAPER) 1" IETAL LATH STUCCO WOOD 5I--IEATI4 NCB OR 1116" ZIP SI-IEATHING; SYSTEM ( INSTALLED PER MANUF. SPECS.) SELF -ADI4ESIVE r-LASNING x x x x FINISH LAYER l2 LAYER EEL 4 StIGK)� 6' EL 4 STI 0 pRIP EDG O DECK I VXI V P.T. OR. SIMULATED WOOD (TREX) LER, CONTINUOUS 3' X 3" 2(o GA. GA METAL DRIP ED SET IN FULfK.1p SEALAI SPACENFRFACE TO T " GOP FOR BACKER .025 4 SEALANT WATER PROOFING I \ II " ` WEATHER RESISTIVE LAYER (2 LAYER P L 4\, BARRIER wi SLICK) WRAPPED F WEATHER RESISTIVE BALCONY DECK TO 1 BARRIER 02 CANTILEVER a' % 6" PEEL 4 STICK ® t PECK MEMBRANE, DRIP EDGE TO DECK , EXTEND OVER DRIP SUB FLOOR EDGE ®® 3" X 3' 26 GA. GALV. METAL DRIP EDGE SET IN FULL BED OF I VIXI V4" P.T. OR AT SEALANT, Ysi" MIN. WOOD (TREX) FI E SPACE FROM DRIP CONTINUOUS FACE TO TREX Y'4" GAP NY CASINGAD ROD 4 SEAL W LER PROOFING let FINISH LAYER AVER LA R (2 LAYER PEEL 4 PEEL 4 STICK) STIG WRAPPED FROM 3/4 RESILIEN 15ALC Y DECK TO HAT CHANN CANTIL R 91 VINYL GASIN EA THICK, COAT CEMENT PLASTER METAL LATH TYPE " DRYWALL WOOD SHEAT W/TEXTURE 4 PAINTED WEATHER RESIS VE FINIS(-4 BARRIER M WEATHER RESIST[ THIC 3 COAL CEMENT BARRIER 02 PLAS R 4'_ POSITIVE DRAIN VINY CORNER 5EADU1EEP SCREED VIlo(YL CASING 5EADNO GAP IN FIELD (SHOWN FOR CLARIFICATION OF SEPARATE ACCESSORIES ONLY) BALCONY DRIP 11A EDGE INSTALLATION Y4" GAP FOR BACKER I ROD 4 SEALAN! — Il VINYL CASING BEAD f '' WATER PROOFING let LAYER (2 LAYER PEEL 4 STICK) nraRr role PEEL 4 WOOD SHEATHING 2x 1=RAMING MMBI=R WRB LAYER "I, — g" THICK, 3 COAT CE NT STUCCO WRAP PLASTER WRB LAYER "2, ORT I/� COR E BUILDING PAPS �% FA SHEATHING AX. X = METAL LATH T; ~ 8" THICK, 3 COAT CO x B LAYER #I, PLASTER STUCCO WRAP 6"SELF-ADHERING FLASI-41NG OOD SHEATHING MET LATH DRIP GAP WRB LAYS PORTF5ER BUILDING PAP WINDOW FLANGE (JRNER BEAD @) FR E 2 1/211 Ik CORNER BEAD (FASTENER 4 SPACING tv 1" O.G.) ctvlu VTHIGK, 3 GOAT CI=MENT PLASTER APPLIED DIRECTLY TO MA50NRY 1 A 1RICORNER BEAD BLOCK ::OLUMN SHEATHING WEATHER RESISTIVE BARRIER "1 WEAL+IER RESISTIVE BARRIER °2 S' S.AF. -PEEL 4 STICK I Vx3' °L' FLASHING FULLY EMBEDDED IN ROOF CEMENT ,1 V X 3" 26 GA. GALV METAL DRIP EDGE SET IN FULL BED OF SEALANT," M SPACE FRO RI FACE TO TI rkx IWOOR 1 SIMUL X PfLLERA S Y4' FOR SEALANT OPT ACKER ROD. -� M PIED 90 /4 RESILIENT HAT CHANNEL WEATHER RESISTIVE BARRIER M WEATHER RESISTIVE BARRIER "2 EXTERIOR COLUMN COLUMN SHEATHING I Ya'x3' 'L' FLASHING FULLY EMBEDDED IN ROOF CEMENT 1 ,4' X 3' 26 GA. GAILY. METAL DRIP EDGE SET IN FULL BED OF SEALANT,,5" MIN. SPACE FROM DRIP FACE TO TREX /INYL CASING BEAD WATER PROOFING let LAYER (2 LAYER PEEL 4 STICK) WRAPPED FROM BALCONY DECK TO ANtILEVER 1" ICK, 3 COAT CEMENT LA TER 5/8" TYPE 'X' DRYWALL I � �� METAL ATH W/TEXTURED 4 PAINTED FINISH WOOD ATHING g" THICK 3 COAT CEMENT 4° Sftl IN PLASTER SC NO GAP IN FIELD VINYL CORNER BEAD (SHOWN FOR CLAIRFI TION OF VINYL CASING BEAD SEPARATE ACCESSOIR S ONLY BALCONY DRIP 11C EDGE INSTALLATION @ COLUMN (wrL" FLASHING) SCALE: NTS NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE ';i i MANUFACTURERS INSTALLATION PROCEDURES i r WOOD SHEATHING 'x WRB LAYER "I, STUCCO WRA WRB LAY 02, FORTIFIBER ' BUILDIN PAPER META ATH \- ) (EXPLOD $" T ICK, 3 COAT CEMENT �VIE w ASTER CLARI i' 11 1 I WRB" Ld�YER "I, STUGC� WRAP WRB LAVE 02, IFIBER ! BUILDI = METAL LA " THIC GOAT CEMENT ! wi PLESAT 6'S LF-ADHERING F SHING i DRIP GAP WINDOW FLANGE 1 CA ING BEAD WINDOW (FRAME, NO BAND) .1 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 F w w W 0 F �0. y q ti A I OUBDIY. de LOT: CREEKSIDE LOT 63 PROJECT# 04321.000 063R1 MODELS 4EAB "1672— ARIA" GA AGE ET47NG: LEFT PAGE: WALL ASSEMBLY DETAILS Q60 MPH EV, C ARCHITECT: STATE OF FLORDA ATE: DATE: 06/06/18 DATE; 93CAIM 1/4"=1'-0" (SHEET LUOOIA SHEATHING WRB LATEN 01, \ STUCCO WRB LAYER *2, F tIFIBER BUILDING PAPER METAL LATH �\ l " THICK, 3 COAT CEMENT PLASTER 6 "SELF -ADHERING FLASHING VINYL ANGED CASING BEAD + DRIP GAP WINDOW FLANGE vi NOTE: IF ZIP SHEATHING SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WOOD 6HEATI4 WRB LATER , S1 UCCO UJ P /AL L.R 0'2, FCRTIF15ER APER I-4COAT CEMENT" PLASTER 'CURB LAYER *2, FORTIFI$E BUILD PAPER( ' METAL MATT-! --{� \ I " THICK, 3 COAT CEMENT PLASTER 6"5ELF-ADHERING FLASHING is 1 DRIP GAP WINDOW FLANGE CASING BEAD G WINDOW 5 ( FRAME, W/BAND) SI-4EAT4NG METAL LAT WRB LATER *1, STUCCO WRAP WRB LAYER *2, FORTIF15E BUILDING PAPER THICK, 3 COAT CEMENT PLASTER VINYL ANGLED CA51NG BEAD VINYL CASING BEAD NOTE: IF ZIP SHEATHING SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WOOD SI4EAT Y4' CzAP TYf- easiNr3 BE4D to TRIM IX TRIM MBER m STUCCO SIDING TRAN ION SIDING LURB LAYER *I, STUCCO WRAP O " THICK, 3 COAT C NT PLASTER METAL LATH L ER 12, FORTIFIBER I ING PAPER '!WOOD SHEATHING: WRB LAYER "I, STUCCO WRAP b" SEL DHEREING FLASHING PEEL E STICK SIDING TO S TUC O CASING BEAD (CROSS SECTION) WOOD CONSTRUCTION BEYOND WOOD SHEATHING — WEATHER RESISTIVE BARRIER Of THEIR RESISTIVE — BA TER *2 XMi ' LLAP SIDING SELF- FLASHING STARTER STRIP DO NOT CAULjK O — SEAL OPENII�TG GALV'D METAL Z' FLASHING I Yl X b' SIMULATED— ` WOOD TRIM MEMEER W�m SIDING TO STUCCO @) BLOCK TO FRAME TRANSITION 6' 88LF-ADI-4ERINCs FLASHING WEATHER RESISTIVE BARRIER "1 WEATHER RESISTIVE BARRIER 02 �iov LASSHINGDHERING GALV'D METAL "Z' FLASHING DO NOT CAULK OR b SIMULATED TRIM MEMBER GAP W/CAULKIP NOTE: METAL LAT{ 4: LATH TO BE PER SECTION R703.7.1 / A5TM C-847-09, MIN. 2.5 LBS. PER 5Q. YARD (UTILITY OR NOMINAL LATI4 DOES NOT MEET SPECIFICATIONS) R #WOO10 CONSTRUCTION— r WOODFS-HAD NEHRSINTIG CO WR,4i= WEATHER BARRIER "1 6000 WEATHER RESISTN! BARRIER "2P SIDING IDVCSIDING �C W R5 L/NI/ R *2, RE AL 000, FLASHINGBIL ., ) roo t = STARTER STRIP _ DO NOT CAULK OR 711 SEAL OPENING (ExPLODED T I CK, 3 C0,4fi C1" �1�1`i \ VIEW FOR 4S�`EfR Cs'FLA5HALvD ING Z' FLASHING _ CLARITY) UJOOID bTR TRIM CASING BEAD OP RAISED 1 BAND (FRAME) SCALE: 1 1/2"=V-0" SEALANT WINDOW i i t 2X FRAMING MEMBER SEALANT WINDOW FRAME i INDOW FLANGE 2X FRAMING MEMBER BUILDING WRAP ------------------- b' HER RESISTIVE RRIER IM TO LAP / 'MIN. ABOVE TOP / OF "Z' FLASHING 1 WEATHER RESISTIVE z \ BARRIER »I WEATHER RESISTIVE / BARRIER 02 GALV'D METAL i W FLASHING DO NOT CAULK OR / SEAL OPENING /' WEATHER RESISTIVE BARRIER M TO LAP W MIN. ABOVE TOP I 'Z' FLASHING ~ I Y' X b' SIMULATED (W/�(," FLEXIBLE VC / i WOOD TRIM MEMBER BACKER ROD) \ / " SELF -ADHERING b' SELF -ADHERING I + i I SDNG FLASHING \ �y' TI 41�K 3 GOAT \\ SEAL AP W/CAULKIA1Cs CEMENT PLASTER OR AP VED SEALANT WEATHER RESISTIVE WEATHER SISTIVE BARRIER �M BARRIER "I WEATHER RESIST A V N , BARRIER "2 (W %" FLEXIBLE PVC BACKER ROC)) SIDING TO STUCCO U ATT RR�SISTIVE C6) FRAME TO FRAME TRANSITION Ira s" THICK, 3 COAT CEMENT PLASTER METAL LATH •---------------------------------------------------------- / E-ZB5AD VINYL B5AD VINYLCA (W/3/e" FLEXIBLE PVC WRB LAY 02, FORTIFIBER BUILDIN PAPER ROD) WRB LAYER 01, UCCO WRAP, WRAPPED AR ND FRAMING MEMBER 6" L A HE51VE FLASHING EATHING ET ELOW EXPLODED O R CLARITY --- --------------------------------------------- lit' THICK, 3 COAT CEMENT " C� BEAD PLASTER WINDOW METAL LATH WRB LAYER 02, FORTIFIBER vW ING PAPER SHEATHING WRB LAYER *I; STUCCO WRAP 6" WIDE PEEL 4 STIC OVER FLANGE E-Z BEAD VINYL CASING (W/3/0" FLEXIBLE PVC BAc *APPLY FULL BED OF SEALANT B FLANGE E BUILDING WRAP LEGEND , r , , i i i r� DRAINAGE PLANE (WRB LAYER #I, STUCCO WRAP) WRB LAYER 02 (FORTIFIBER — — — — BUILDING PAPER) METAL LATI4 x—x—x—x STUCCO F. WOOD 5I-4EATI 41NG OR 1/16' TIP SHEATIPINGs SYSTEM (INSTALLED PER MANUF. 6F:q=-C6J SELF-ADHESIVE FLASHING - - - - ROD) 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 w U h F 0. U w a F h BMW da LOT: CREEKSIDE LOT 63 PROJECT# 04321.000 063R1 MoDELa 4EAB "1672- ARIA" GARAGE SIVING: LEFT PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP. C ARCHITECT- STATE OF FLONDA npTE., 06/0 6 /18 ®CAL1/4" F =1'-0" !SHEET OUT HOUSEWRd AT 45' ANGLE MODIFIED "I' OUT IN HOUSEPUP LINE OF L OPENING APPROVED HOUSEWRAP OVER SHEATHING OVER WD STUD WALL STEP I INSTALL 6' SELF —ADHERING FLASHING OVER NAILING FLANGE AT JAMBS EXTEND FLASHING MIN I' BELOW SILL FLEX15LE FLASHING DO NOT SEAL BOTTOM FIN STEP 6 NOTE: il- f=fROCEED�fRE5 APPLY N MEMBRAE FLASHING OVER JOINT `L_ 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 W U W ti iz 0. W q F A F» tiImmilm BtTHDIV. ee LOT: CREEKSIDE LOT 63 PRAJECT# 04321.000 063R1 DLODEL: 4EAB "1672- ARIA" GARAGE iswu LEFT PAGE: WALL ASSEMBLY DETAILS: WINDOW FLASHING 160 MPH EXP. C MR fPDpAtrTKJT:06/06/18 SCALM 1/4"=1'-0" SIiC�ET 2x(o 5U5-BAND W/I"x4" NOTCH 6 END, WRAPPED IN PEEL E STICK METAL FA DRIP EDGE\\ l\ 1/8" TEXTURED I \\ 1=INI5H 'w WOOD I \ 2x& sue 1 1/2" TEXTURED r \ FINISH CMU \ METAL FASCIA \ O WRAP YS" FROM \ STUCCO, I" FROM \\ WOOD WALL \ EXTERIOR WALL \ i (FRAME OR GMU) \ \ NOTE: NOTCH FOR 2X6 \ SUB BAND ONLY ROOF KICK OUT REMOVED FOR CLARITY \ ROOr DECK (BEYOND) DRIP EDGE, I" OF:P WALL �'IIIITI1ZI17I._ - _ -1 VNOT INTO STUCCO) -1/0" TEXTURED FINISH 1 / WOOD, 1/2' TEXTURED -- -- �`` --- �� 1=1N15H m CMU 2x& SUB -BAND W/I"x4" NOTCH a ." END, WRAPPED IN PEEL 8 STICK ®ELEVATION_ PLAN A 1 METAL 1=ASCIA WRAP 1" OIL WOOD WALL. SUS BAND 2 ° OFF WOOD WALL i• � I 7/8' TI=XTURED FINISH ® UJOOD, 1/2" TEXTURED FINISH B GMU METAL LATH UJOOD SHEATHING OR GMU UJRB LAY(=R M, 5TUCCO WRAF' (FRAME ONLY) WRB LAYER 02, FORTIPIBER BUILDING PAPER (FRAME ONLY) ROOFING CEMENT DRIP EDGr= METAL KICK OUT NOTE: IF ZIP 5HEATHING SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES PRE-ENG'D TRUSS TO BE CUT 6 WALL LINE TO AVOID CONTACT W/TEXTURED FINISH 2 "x4"x4' - o ll SCABBED TO TRUSS W/126 NAILS bil-S" O.C. MAX. 2x SUB -RAND W/IY"x4" NOTCH 6 END METAL 1=ASCIA WRAP DRIP EDGE EXTERIOR WALL (FRAME OR CMU) SUB BAND DETAIL C) WALL x x x x x x x '4'0'� x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X x x x x x x x x x x -' A x x x x x x x x x x x x x x x x x x x x --- ' x x x x x x x x x x x SUB BAND DETAIL C WALL W./KICK-OUT FRAME OR CMU FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. ,V4" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/IY11x4" NOTCH e END, WRAPPED IN PEEL 4 STICK *ROOF CEMENT e ROOF EDGE OMITTED FOR CLARITY FRAP'IE OR GMU WALL KICK -OUT 1=LASHING FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. Y4" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/IY"x4' NOTCH tv END, WRAPPED IN PEEL 4 5TICK *ROOF CEMENT o ROOF EDGE OMITTED FOR CLARII"Y 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 w U W t. 0 F U cli w q F q z stmDrv. ee LOT: CREEKSIDE LOT 63 PROJECT# 04321.000 063R1 MODEL: 4EAB "16'72- ARIA" GARAGE O ING: LEFT PAGE: WALL ASSEMBLY DETAILS: SUB -BAND 160 MPH EXP. C ARCHITECT - STATE OF FLORIDA Ju 0 7 DATja 06406/18 SCALE: 1/4=1' — o ' 81-MET