HomeMy WebLinkAboutCHECK LISTCHECIt LIST PRE 89-1621 Project Name: Architect: Contractor: Owner: Address: y S(OE® BY ST. LUCIE BUSINESS PARK - WAREHOUSE - SHELLSM- L.d1 e(COUAI RALPH BOUZA Ph: (305) 496-3711 (MIAMI) CATALFUMO CONSTRUCTION, INC. ph: (407) 471-0338 (W.PALM) PAUL JENNAH BLOSSOM CORP. S. US 1 PORT ST. LUCIE, FL Ph: (305) 576-6333 (MIAMI) Occupancy Classification: S - Type of Construction: p _ -- Height and Area: 2cs 030 // t pop L---�Q &—,o f cre s'e Occupancy Requirements per Chapter IV: Construction Requirements: A. Fire Protection: B. Egress Requirements: b d d>",j Other Requirements: Alk Elevators pa4>dv Sprinklers 6 Standpipes ® `4XA10-J Combustible Materials - Interior Roof Coverings doq�� Light - Ventilation - Sanitati S�pwst) Handicap Requirements III rC110. \' Plans sent to Fire Dept. - Date: S -z z 12 7 Approved: Plot Plan Check Water Seger Energy Code Paving b Drainage approval by Engineering Dept. Special Conditions prior to issuance Threshold Affidavit/Before Issuance Affidavit re'v-'e2 "t- 89-1621 Project Name: Architect: Contractor: CHECK LIST SM. tl 90 Ely ST. LUCIE BUSINESS PARK - WAREHOUSE - SHELL RALPH BOUZA CATALFUMO CONSTRUCTION, INC. Owner- I JENNAH BLOSSOM CORP. Address- S. US 1 PORT ST. LUCIE, FL ph: (305) 496-3711 (MIAMI) v►,- (407) 471-0338 (W.PALM) PAUL ph: (305) 576-6333 (MIAMI) Occupancy Classification: 1 Type of Construction: Height and Area: 2d, %30 ! /6�poo L-tf/6 A &na l xwreoSy- Occupancy Requirements per Chapter IV: &rla AawcAr Construction Requirements: A. Fire Protection: -E o )6e c.&gss rgeal M B. Egress Requirements: 6 K F-&,r Zik,&LLo b Mea ®oJ 5: de#.r*W 4L tkse c Other Requirements: 'd A Elevators 'j/"" p` >&) Sprinklers 6 Standpipes Combustible Materials - Interior Roof Coverings Awe-_ _-C"wo Light - Ventilation - Sanitation Handicap Requirements Plans sent to Fire Dept. - Date: 3 -z Z Approved: Plot Plan Check Water Energy Code Sever Paving b Drainage approval by Engineering Dept. Special Conditions prior to issuance Threshold Affidavit/Before Issuance Affidavit re W4 a. r � "s r 4 0 ST. LUCIE BUSINESS PARK PR 89-1621 - PLANS REVIEW MAY 22, 1989 CHUCK McDERMOTT 1. SHEET P-1 - SHOWS SANITARY WITH NO CLEAN OUTS INSIDE OF BUILDING. NEEDS TO COMPLY WITH STANDARD PLUMBING CODE, SECTION 704 THRU 706.2. 2. SHEET A-1 - TURNING RADIUS AT ENTRANCES DOES NOT AGREE WITH SITE PLAN INTERIOR TURNING RADIUS DELETED FROM THIS PLAN. 3. SIGN DETAIL SHOWN ON SHEET A-1 IS NOT INCLUDED IN THIS PERMIT. 4. PHASE LINE FLOATS FROM SHEET TO SHEET FROM 190' TO 208'. ST. LUCIE BUSINESS PARK PR 89-1621 - PLANS REVIEW MAY 22, 1989 CHUCK McDERMOTT 1. SHEET P-1 - SHOWS SANITARY WITH NO CLEAN OUTS INSIDE OF BUILDING. NEEDS TO COMPLY WITH STANDARD PLUMBING CODE, SECTION 704 THRU 706.2. 2. SHEET A-1 TURNING RADIUS AT ENTRANCES DOES NOT AGREE WITH SITE PLAN INTERIOR TURNING RADIUS DELETED FROM THIS PLAN. 3. SIGN DETAIL SHOWN ON SHEET A-1 IS NOT INCLUDED IN THIS PERMIT. 4. PHASE• LINE FLOATS FROM SHEET TO SHEET FROM 190' TO 208'.