Loading...
HomeMy WebLinkAboutEVALUATION REPORTSCANNED BY sit, "Lucie (County EXTERIOR RESEARCH & DESIGN, LLC. 0 FILE COPY Certificate of Authorization �l9503 ERD 353 Christian Street Oxford, CT 06478 TRINITY I , (203) 262-9245 4LUATION REPORT glass USA, Inc. Lyon Drive ley, NV 89408 1384-1230 Evaluation Report P40690.12.13-1-R6 FL16717-R5 Date of Issuance:12/12/2013 Revision 6: 09/12/2017 Tlh Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code, High Velocity Hurricane Zone (HVHZ) sections noted h�,[ein. DgkRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems I LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted -ern. VTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced ality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of s Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product inges or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this rluation Report relative to updated Code requirements with each Code Cycle. VERTISEMENT: The Evaluation Report number preceded by the words "Engineer Evaluated, FBC (HVHZ)" may be played in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its PECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or distributors and shall be available for inspection at the job site at the request of the Building Official. Evaluation Report consists of pages 1 through 6, plus a 57-page Appendix. by: t J.M. Nieminen, P.E. Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/12/2017. This does not serve as an electronically signed document. IFICATION OF INDEPENDENCE: Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY I ERD 4. PRODUCP DESCRIPTION: This Evaluation Report covers Polyglass SBS and APP Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. TABLE 1: ROLL -GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS �. Type Product Specification Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A 111 , Polyflex SA Base ASTM D4601 N/A 11M Polyglass APP Base ASTM D6509 N/A N/Al Elastoflex SA V (1.5-mm) ASTM D4601 N/A II Elastoflex SA V FR (1.5-mm) ASTM D4601 N/A II .IM SBS Membranes Polyglass HT Base 650 ASTM D6162 S III Elastobase ASTM D6163 S I Elasto _ lasto�ex .ice '.- E ast'ofiez V P us FR __ASTM D616.3 S I *35TI D6163. :-'. - S ASTM D6163 ` S I Elastobase Poly ASTM D6164 S I Elastoflex S6 ASTM D6164 S I Elastoflex VG ASTM D6163 G I Elastoflex VG FR ASTM D6163 G I Elastoflex S6 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G I Polyfresko G SBS (sand or poly -film backed) ASTM D6164 G I Polyfresko G SBS FR (sand or poly -film backed) ASTM D6164 G I Elastoshield TS G ASTM D6164 G Elastoshield TS G FR _ ---ASTM61624 — G I Elast_o'flex�5 "-�_ = - _ �'r�ti` •C ^ G: , 1 � �iiQST ° G as —to fIex S- P FR- ASTM D6164 G I Polyreflect ASTM D6164 S I APP Membranes Polyflex ASTM D6222 S I ;� Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G I Polyfresko G ASTM D6222 G I Polyfresko G FR ASTM D6222 G I Polybond ASTM D6222 S I Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G 171 Polyflex SA P FR ASTM D6222 G I Polyfresko G SA ASTM D6222 G I Polykool ASTM D6222 S III 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was usedl for permitting or design guidance unless retained specifically for that purpose. 5.2 Fire classification is not part of this Evaluation Report; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.3 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. Exterior Research and Design, I.I.C. Evaluation Report P40690.12.13-1-R6 Certfjhate ojAuthoriration #9503 6EDITION (2017) FBC HVHZ EVALUATION FL16717-RS Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 6: 09/12/2017 Page 4 of 6 TABLE 1E: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck (Note 1) Insulation Layers) Base Sheet Roof Cover (Note 15) MDP No. Type Attach Type Fasten Attach Base Ply Cap Ply I (Psf) ASPHALT -APPLIED OR TORCH -APPLIED BASE PLY: Elastobase, Elastobase P, Min. 19/32- One or more Prelim. Polyglass G2 Base, CertainTeed OMG Flat Bottom Plates (square) with Roofgrip #14; Dekfast Hex (aka, Dekfast PIT- 12-inch o.c. in 4-inch lap and 12- (Optional) BP -AA, SBS-AA, SBS- 49 i�v plywood layers, any Attached Glasbase, Firestone MB Base, H with Dekfast or Trufast 3" inch stag in two (2), equally spaced, SBS-AA, SBS-TA or TA, APP-TA 52.5 combination fM Perma-Ply 28, Tamko Glass Metal In wit#14h Metal Insulation Plate with Trufast HD staggered center rows APP-TA Base or GAFGLAS #75 Min. 19/32- One or more Prelim. OMG Flat Bottom Plates (square) with 12-inch D.C. in 4-inch lap and 12- (Optional) BP -AA, SBS-AA, SBS- W-50. inch plywood layers, any Attached Elastobase or Elastobase P Roofgrip #12 inch D.C. in two (2), equally spaced, SBS-AA, SBS-TA or TA, APP-TA -60.0 combination staggered center rows APP-TA Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32- One or more Prelim. Polyglass G2 Base, Elastobase, Dekfast #14, OMG 3" Round Metal Plate 10-inch D.C. in 4-inch lap and 10- (Optional) BP -AA, SBS-AA, SBS- W-51. inch plywood layers, any Attached Elastobase P with OMG HD, OMG Flat Bottom Plate inch o.c. in three (3), equally SBS-AA, SBS-TA or TA, APP-TA -75.0 combination (Accutrac) with Roofgrip #14 or Trufast 3" spaced, staggered center rows APP-TA Metal Insulation Plate with Trufast HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32- One or more Prelim. Dekfast #14, OMG 3" Round Metal Plate 10-inch D.C. in 4-inch lap and 10- W-52. inch plywood layers, any Attached Polyglass APP Base with OMG HD, OMG Flat Bottom Plate inch D.C. in three (3), equally (Optional) APP-TA APP TA -75.0 combination (Accutrac) with Roofgrip #14 or Trufast 3" spaced, staggered center rows Metal Insulation Plate with Trufast HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32- One or more Prelim. Polyglass G2 Base, Elastobase, Dekfast #14, OMG 3" Round Metal Plate 9-inch D.C. in 4-inch lap and 9-inch (Optional) BP -AA, SBS-AA, SBS- W-53. inch plywood layers, any Attached Elastobase P with OMG HD, OMG Flat Bottom Plate D.C. in four (4), equally spaced, SBS-AA, SBS-TA or TA, APP-TA -90.0 combination (Accutrac) with Roofgrip #14 or Trufast 3" staggered center rows APP-TA Metal Insulation Plate with Trufast HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. One or more Prelim. Dekfast #14, OMG 3" Round Metal Plate 9-inch D.C. in 4-inch lap and 9-inch W 54 inch pll yw plywood layers, any Attached Polyglass APP Base with OMG HD, OMG Flat Bottom Plate D.C. in four (4), equally spaced, (Optional) APP-TA APP TA -90.0 combination (Accutrac) with Roofgrip #14 or Trufast 3" staggered center rows Metal Insulation Plate with Trufast HD. - W-55. Min. 15/32- One or more layersany Prelim. Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with 6-inch o.c. at 4-inch lap and 6-inch stag in three equally spaced, (Optional) BP -AA SBS-AA 90.0 inch plywood combination Attached Trufast 3" Metal Insulation Plates staggered center rows or SBS-AA Min. 15/32- One or more Prelim. OMG #12 Standard Roofgrip or OMG #14 6-inch D.C. at 4-inch lap and 6-Inch (Optional) BP -AA, W-56. inch plywood layers, any Attached Elastobase, Elastobase P Heavy Duty with OMG 3" Round Metal D.C. in three (3), equally spaced, SBS-AA, SBS-TA, SBS-AA, SBS- -90.0 combination Plates or OMG Flat Bottom Metal Plates staggered center rows APP-TA TA or APP-TA Min. 15/32- One or more Prelim OMG #12 Standard Roofgrip or OMG #14 6-inch o.c. at 4-inch lap and 6-inch W 57. inch plywood layers, any . Attached Polyglass APP Base Heavy Duty with OMG 3" Round Metal D.C. in three (3), equally spaced, (Optional) APP-TA APP TA -90.0 combination Plates or OMG Flat Bottom Metal Plates staggered center rows Exterior Research and Design, LLC. d/b/a Trinity) ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 C" EDITION (2017) FBC HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Evaluation Report P40690.12.13-1-R6 for FL16717-RS Revision 6: 09/12/2017 Appendix 1, Page 15 of 57