HomeMy WebLinkAboutCONCRETE FOUNDATION-BASE RAIL ANCHOR DETAILEpp -------------------------------------------�Pll,WE ---------------------------- - ----------------- 12"x12" REINFORCED FOOTER BY m 0 Z o z W TITS ERE I I 4"x3"(2,500 LB.) CONCRETE I WEDGE ANCHOR WITHIN 6" I OF EACH POST. I U) O m r> 0- J Y Rz � CODE INFORMATION ' ._ 2" MIN. BASE RAIL ' EMBEDMENT MIN. i I I GRADE .I - o I i - _ _ _ _ _ _ __ _ _ _ _ L_...=..1 • ' _ — - _ 2,500 PSI 4" CONCRETE i SLAB WITH W.W.F. OR FIBER MESH �-12" (2) #5 REBAR ® 6" O.C. i MINIMUM SOIL BEARING CONTINUOUS WITH MINIMUM i CAPACITY 2,000 PSF (TYP.) 12" OVERLAP SPLICE i v 10 Z O O U W alf UO ni1T 0 O. W W z \V 3: _:�: Q g J .W„ ,W.. W Z W W W Q < U) of CL V) CODE VERSION FBC 2017 6th Edition, ASCE-7-10 MANU ACTURER CARPORTS ANYWHERE BUIL ING TYPE UTILITY STRUCTURE CON UCTION TYPE II—B R PROTECTION _ R SUPPRESSION SYSTEM NONE NONE OC PANCY STORAGE ALLOWABLE NUMBER OF STORIES 1 BASIC WIND SPEED Vm 150mph EXPOSURE c ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.18 IMPORTANCE FACTOR 1.16 CONCRETEFOUNDATION/BASE RAIL I ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b POINT LOAD I I ANCHOR DETAIL' FLOOR DEAD LOAD 1OPSF "R" RATING OF WALLS, FLOOR, ROOF N/A - I MODULES PER BUILDING 1 j I HURRICANE PROTECTION USAGE NO I I I HURRICANE SHELTER USAGE NO I I SQUARE FOOTAGE 900 so. FT. REVISIONS - i I I I � REV DESCRIPTON DATE BY I I I I O 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER ROLL�UP NOTES: MESH) AND 12"x12" REINFORCED FOOTER PERIMETER DOOR I o I I SUB -GRADE SOILS: CD -TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION . _ I Dra*n By: MTB r I I CONCRETE: -MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS Date: 7/6/ 18 Loc ": �210 speed Road, Ft. Pierce, 34945 REINFORCING STEEL (REBAR) REQUIREMENTS: Model : 301 X 30'W X 1O'H ERAL 1ETHHIS B"DLDI G IS EXEMPT FROM THE FBC ENERGY NSERVATION CODE PER 2. ALOL STEEL TUBING SHALL BE OOKSI OSTEEL. 3. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SEr-BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY AT THE OWNER. 4. ROOF AND WALL SHEATHING SECURED WITH d12-14x1' SELF-DRIWNG SCREWS WITH SEAL WASHERS O 6' O.C. MAX. 5. FIELD FRAMING CONNECT ONS SECURED WITH �12-14x3/4• SELF-DRIWNG SCREWS. 6.ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. 7.CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2'x3', 2,600LB TENSILE STRENGTH. 8. 14CA FRAMING IS 2.5x2.5' TUBE STEEL NIPPLES ARE 225x225' TUBE STEEL 2 -MINIMUM GRADE 40 STEEL -REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: I I -THE REBAR IS BENT COLD -THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6-BAR DIAMETERS: AND I I -REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES I I WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1 " HORIZONTALLY TO 6" VERTICALLY. -COVER: I I -3" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH I SOIL OR WEATHER, AND 14" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF 4" FOR FINE GROUT, AND 4" FOR COARSE GROUT .BETWEEN REBAR AND I ANY FACE OF A CELL. REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING I GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 11" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. o 1 O ® ' I - I GALVANIZATION: > -METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO - -- -- - --- -- - — - - -- -- - AI�I�-( AVARI ' - - - R9APlb'1`tA-Y. T' I=ST;vA G z—rL-A,� --r,—M _ . — - --- - - -- - - - e CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DIRECTLY TO WEATHER SHALL BIE STAINLESS STEEL OR I - - ---- - - - - I — - HOT DIPPED GALVANIZED. ui ------------------------SWI-NGING---------------------------------------------------------------------------------------------------------------------; DOOR 3: LLI 7/6/ 18 . 71 4'-58" 1 3'-0" 30r—On _ z Q Matthew T. Baldwin P.E. Florida License #64608 w ~ �- c -Sheet: CA— 1 OF 4 CARPORTSANYWHEIM CODE INFORMATION CODE VERSION FBC 2017 6th EdiOan, ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE ' T 12 3 �0" OA• MCI 3._413• TT66 3•_413• TTS6 3•_,13. 'i�-o6 12 3� ._Q - ----" CONSTRUCTION TYPE 11-13 FIRE PROTECTION _ NONE - - -- - - FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE 10,-0" ALLOWABLE NUMBER OF STORIES I BASIC WIND SPEED Ve 150mDh EXPOSURE C ENCLOSURE ENCLOSED ' INTERNAL PRESSURE COEFFICIENT +/- 0.18 IMPORTANCE FACTOR 1.15 ROLL -UP 12 GA. POST DOOR 12 GA. POST ROOF DEAD LOAD IOPSF ROOF LIVE LOAD 20PSF OR 3001h POINT LOAD o o 0 FLOOR DEAD LOAD 10PSF "R' RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE, NO SQUARE FOOTAGE 900 SQ. FT. REVISIONS 3,_" 3._" 10'-0' 3,_" 10'-0" 30,-0" 3_x3_• 3•_�3_" 3,_x3-" �T66 10'-0"'�`ff66 '"'ttbb �3•_.,11., 3,_0"" 3._O". ITS W-6 �tS 3,_„11., 3._Q". 3•_Rjj" 3'_�f6" 3— ITS �iS ••Ta 30•_0• REAR END WALL I REV DESCRIPTON DATE BY FRONT END WALL Dro*n By: MTB Date: 7/6/ 18 Locoti n: 210 Sneed Road, Ft. Pierce, 34945 Model - 301 X 30'1N X 1O'H GENERAL NOTES 1. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION 1015.22- 2. ALL STEEL TUBING SHALL BE 60 KSI STEEL 3. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY - CO SWINGING- DOOR SEr—BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 4. ROOF AND WALL SHEATHING SECURED WITH 812-140' SELF—DRIWNG SCREWS WITH SEAL WASHERS m 6" O.C. MAX. 5. FIELD FRAMING CONNECTIONS SECURED WITH Al2-14x3/4' SELF—DRIWNG SCREWS. �y 7. CONCREOTEE EXPANSIONSFRAMING INANCHORS ARE 7O BE AMUM 1/2'x3', 2,50OLB TENSILE STRENGTH. 8. 14GA FRAMING IS 2.5'x2.5' TUBE STEEL NIPPLES ARE 2.258x2.25' TUBE STEEL 3 LLJ "--{ > . 30,-0" -I 30,-0" LEFT SIDE WALL RIGHT SIDE WALL 0 Z_ Q / W 7/6/18 LLI Q Matthew T. Baldwin P.E. Florida License #664608 Sheet:- CA-2 OF 4 S MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL. POST WITH (4)812-14x3' SELF -DRILLING SCREWS ,d3�,AIPPLE TO BASE RAIL NIPPLE I POST TO BASE RAIL CONNECTION. MINIMUM 6' TS NIPPLE. NIPPLE SECURED TO WALL POST WITH It (4)#12-14xj" SELF -DRILLING SCREWS 2"x2"x2' 16 GA ANGLE CUP SECURED WITH (4) #12-14x4" SELF-DRIWNG 2'x2'x2' 16 GA ANGLE CUP SECURED SCREWS WITH (4) #12-14xj' SELF -DRILLING SCREWS —I II__ 1' 1I INTERMEDIATE POST TO END POST TO BASE RAIL HEADER/BASE RAVOR CONNECTION. WINDOW --RAIL DETAIL. _ 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xi" SELF —DRILLING SCREWS NON—STRUCTURAL HEADER OR WINDOW RAIL TO POST DETAIL 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14Xj" SELF —DRILLING VARIES STD. MAX. SPACING 3" _71- STD. MAX. SPACING VARIES SIDE WALL ROLL —UP DOOR HEADER DETAIL k x2' 16 GA. ANGLE CUP RED WITH (4) #12-14Xj'-DRIWNG SCREWS GLE OR DOUBLE TS HEADER MINIMUM 6' TS NIPPLE NIPPLE SECURED TO WALL POST WITH (4)#12-14xj" SELF-DRIWNG SCREWS SINGLE OR DOUBLETS HEADER NIPPLE TO BASE RAJL HEADER CONNECTION HEADER CONNECTION DETAIL DETAIL OPTION 1 __ __- ___-- OPTI-ON 2- 26 GAUGE ROOF SHEATHING SECURED WITH (1)#12-14x1' SELF-DRIWNG SCREWS ® 6" O.C. (9" O.C. MAX.) 1" 16 GAUGE FURRING CHANNEL 48" O.C. MAX. SECURED WITH (2)812-140" SELF -DRILLING SCREWS TO EACH RAFTER. ROOF PANEL CONNECTION VERTICAL SHEATHING OPTION NIPPLE MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14,j' SELF-DRIWNG SCREWS POST TO TRUSS CONNECTION INSTALL PER MANUFACTURERS INSTRUCTIONS 26 GA RIDGE CAP #14x1' SELF -DRILLING - NIPPLE T0\,j:L. #12-14)r SELF -DRILLING SCREWS ® 10' O.C. MAX, 3' SCREWS 0 6' O.C. MAX. k 6" MAX. FROM CORNERS RAFTER MAX. FROM CORNERS HORIZONTALLY/ 4" MAX. FROM CORNERS VERTICALLY 26 GA ROOF SHEATHING MINIMUM 6" TS NIPPLE NIPPLE INTERIOR EXTERIOR 1z" 0o 26 GAUGE ROOF SHEATHING SECURED SECURED TO WALL POST WITH (4)#12-14x3" SELF-DRIWNG SCREWS �11 WITH (1)®12-14x1' SELF-DRIWNG SCREWS ® 9" O.C. MAX. MINIMUM 24' TS NIPPLE DOOR FRAME TO POST ROLL —UP DOOR TO ROOF RIDGE CAP BOX EAVE RAFTER TO TRUSSED RAFTER CONNECTION POST CONNECTION REINFORCEMENT POST CONNECTION DETAIL CONNECTION DETAIL DESIGN PRESSURES — 150 Mph ROOF +19.3/-41.4 WALLS +22.2/-20.0 DOORS +22.2/-20.0 - -----� -------- - - ---- 1 2 3 4 5 ZONE +9.3 —21.9 + 12.3 —35.1 + 19.3 —41.4 +22.2 —20.0 +21 .9 —18.8 APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carolina Carports, Inc. 26 Ga. AG Roof Panel FL6596.1 WALL SHEATHING Carolina Carports, Inc. 26 Go. AG Panel FL6702.1 SWINGING DOOR THERMA—TRU CORPORATION FL15225.1—R4 ROLL —UP DOOR ASTA DOOR CORPORATION 203 WINDLOCK FL8888.1—R5 f► D-0 t 1 t CODE VERSION FBC 2017 6th Edition, ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UnUTY STRUCTURE CONSTRUCTION TYPE II-B FIRE PROTECTION NONE ___- FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES 1 -- BASIC WIND SPEED V.-150mph EXPOSURE C ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.18 IMPORTANCE FACTOR 1.15 , ROOF DEAD LOAD ;0PSF ROOF LIVE LOAD 2OPSF OR 30016 POINT LOAD FLOOR DEAD LOAD fOPSF "R" RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE No HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 900 SO. FT. REVISIONS MTB 7/6/18 0 Sneed Road, Ft. Pierce, 34945 301 X 30'W X 10'H 1. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION 1015.22. 2. ALL STEEL TUBING SHALL BE 50 KSI STEEL. 3. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 4. ROOF AND WALL SHEATHING SECURED WITH a12-14x1' SELF -DRILLING SCREWS WITH SEAL WASHERS 0 6" O.C. MAX. 5. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF-DRIWNG SCREWS 6. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED_ 7. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2"x3', 2,500LB TENSILE STRENGTH, 8. 14GA. FRAMING IS 2.5x25' TUBE STEEL. NIPPLES ARE 2.26'x2.26' TUBE STEEL. 0 7/6/18 Q Matthew T. Baldwin P.E. Florida License #64608 Ld o Sheet: CA-4 OF 4 F-