HomeMy WebLinkAboutSEWAGEOCANNED
RECEIVED
# : AP1349573
q,e
BY
APPLICATION
STATE OF FLORIDA M. Lucie ie CoUtityAPR 2 9 2019
PERMIT # : 56-SF-1854695
DEPARTMENT OF HEALTH
DOCUMENT #:06/13/
ONSITE SEWAGE TREATMENT AND DISP09kVt.�ihRW.nment
t. ucie ounty 06/13/2018
01
•~�
CONSTRUCTION INSPECTION AND FINAL APPROVAL
pA
DATE PAID:
FEE PAID:515.00
RECEIPT #:56-PID-3589947
f l
APPLICANT: Jose
Macias I In
AGENT: Ja es
Trefelner
PROPERTY
II DREss: 3148 Brocksmith Rd Fort Pierce, FL 34945
LOT: 2
BLOCK:
sUBDIVISI
N:
I
ID#: 2329-502-0002-000-1
CHECKED [XI ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TA
INSTALLATION
SETBACKS
[ ] 1011
TANK SIZE [1] 1090.00 12] [ ]
[271
SURFACE WATER 105 FT
[ ] [01]
TANK MATERIAL Polypropylene [ ]
[28]
DITCHES 100 FT
[ ] [O
]
OUTLET DEVICE [ ]
[29]
PRIVATE WELLS 100 FT
[ ] [041
MULTI —CHAMBERED [ Y N ] [ ]
[30]
PUBLIC WELLS FT
[ ] 10
]
OUTLET FILTER Polylok PL-68 [ ]
[31]
IRRIGATION WELLS FT
[ ] [O
]
LEGEND 1. 70-143-11DC3 2. [ ]
[32]
POTABLE WATER 75 FT
[ ] [0]
WATERTIGHT [ ]
[33]
BUILDING FOUNDATIONS 6 FT
[ ] 10
1
LEVEL [ ]
[34]
PROPERTY LINES 100 FT
[ ] [0)1
11
DEPTH TO LID [ ]
[35]
OTHER FT
D
INFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ ] [ll]
AREA [11 679.2 [2] SQFT [ ]
136]
DRAINFIELD COVER
[ ] Eli]
DISTRIBUTION BOX HEADER x [ ]
[37]
SHOULDERS
[ ] [1
2]
NUMBER OF DRAINLINES 1. 6.00 2. [ ]
[381
SLOPES
[ ] [1
]
DRAINLINE SEPARATION [ ]
[391
STABILIZATION 04/26/2019
[ ] [1,1]
DRAINLINE SLOPE
[ ] [1]
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ] [ll]
1
ELEVATION [ ABOVE / HELOW IBM 31.00 [ ]
[40]
UNOBSTRUCTED AREA
[ ] [1
1
SYSTEM LOCATION [ ]
[41]
STORMWATER RUNOFF
[ 7 [131
DOSING PUMPS [ ]
[421
ALARMS
[ ] [lll]
AGGREGATE SIZE [ ]
[43]
MAINTENANCE AGREEMENT
[ ] [211]
AGGREGATE EXCESSIVE FINES [ 1
[44]
BUILDING AREA
[ ] [2
]
AGGREGATE DEPTH [ ]
[451
LOCATION CONFORMS WITH SITE PLAN
[ ]
[46]
FINAL SITE GRADING.
FI,IL
/ EXCAVATION MATERIAL
[ 1
[471
CONTRACTOR MICHAEL W STUHR (ASHTO
[ ] [2
I ]
FILL AMOUNT
[ ]
[48]
OTHER INFILTRATOR Quick4 Plus EQ36 LP
[ ] [2
]
FILL TEXTURE
[ ] [2
1
]
EXCAVATION DEPTH
ABANDONMENT
[ ] [21]
1
AREA REPLACED [ ]
[49]
TANK PUMPED
[ ] [2
]
REPLACEMENT MATERIAL [ ]
[50]
TANK CRUSHED 6 FILLED
Comments:)
Comments
are on page 2.
/
St. Lucie CHD DATE: 02/20/2019
CONSTRUCTION
[ APPROVED
DISAPPROVED ] Environmental Spec alist II Bri
Ingram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM
[ APPROVED / DISAPPROVED ]:
St. Lucie CHD DATE: 04/26/2019
Environmental Specialist II Br)4
J Ingram (ENVIRONMENTAL
HEALTH)
all
(Explanatil
of Violations on Following page)
DH 4016,
g8/09 (Obsoletes all previous editions which may not
be used)
Page 2 of 3
Incorporated:
64E-6.003, FAC
EH Database v 1,0.1 AP1349573
EID1054695
� APPLICATION # : AP1349573
T STATE OF FLORIDA PERMIT #:56-SF-1854695
�- DEPARTMENT OF HEALTH DOCUMENT #:F11282560
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM 06/13/2018
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:
FEE PAID:515.00
RECEIPT #:56-PID-3589947
Violation humber Comment
Comments 11
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 400
gpd.
New ST, ou ��et�filter and 6xl0 long DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final
inspection f r mound system and final site grading.
Final syste laDDroved. Contractor end building department emailed final approval.
DH 4016,E08/09 (Obsoletes all previous editions which may not be used)
Incorpor lted: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1349673 EID1054695