HomeMy WebLinkAboutPRODUCT APPROVAL1/9/2018
riui iu U'DUliuii u ii,uutl .it n❑ is
1 • _ M _ f
SCANNED
. Professional Regulation BY
st. Lucie County
BCIS Home Log In • User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff I BCIS Site Map i Links Search
Product Approval
\m USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL9555-R4
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email.
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
UNION CORRUGATING COMPANY
701 S. KING ST.
FAYETTEVILLE, NC 28301
(910) 483-0479 Ext256
jstieby@unioncorrugating.com
John Stieby
jstieby@unioncorrugating.com
Structural Components.
Roof Deck
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 09/07/2027
Validated By Yoosef Lavi, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL9555 R4 COI CertificateIndeoendence.Ddf
Standard Year
ASTM E1592 2005
FM 4470 2012
r�
https://www.florltlabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtvOROQkZA5RE8EOgziUd]7ntuFlu2jC5sp/o3d 1/3
l /y/zu _I tl
Product Approval Methi
rionua tsuuaing uoae vnnne
' Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
SLimmFAru of Prneiiirft
08/23/2017
08/28/2017
09/09/2017
12/12/2017
EL *
Model, Number or Blame
Description
9555.1
5V Panel
29 ga., 24" wide, through fastened panel over wood supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II EvaluationRenortC2-172 I.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-70.25
Evaluation Reports
Other: Uplift load of 70.25 psf @ support spacing of 24" o.c.
FL9555 R4 AE EvaluationReportC2172 I.pdf
Created by Independent Third Party: Yes
9555.2 MasterRib Panel
26 ga., 36" wide, through fastened panel over steel supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 1I EvaluationReportC2172 2.ndf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-47.2
Evaluation Reports
Other: Uplift load of 47.2 psf @ support spacing of 60" o.c.
FL9555 R4 AE EvaluationReportC2172 2.pdf
Created by Independent Third Party: Yes
9555.3
MasterRib Panel
29 ga., 36" wide, through fastened panel over steel supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II EvaluationReportC2172 3.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +27.1/-37.7
Evaluation Reports
Other: Design load of 27.1 & -37.7 psf at support spacing of
FL9555 R4 AE EvaluationReportC2172 3,Pdf
48" o.c.
Created by Independent Third Party: Yes
9555.4
MasterRib Panel
29 ga., 36" wide, through fastened panel over wood supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II EvaluationRellortC2172 4.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +27.1/-36.2
Evaluation Reports
Other: Design load of 27.1 & -36.2 psf at support spacing of
FL9555 R4 AE EvaluationReportC2172 4,pdf
48" o.c.
Created by Independent Third Party: Yes
9555.5
MasterRib Panel
29 ga., 36" wide, through fastened panel over nom. 1" x 4"
wood supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II EvaluationReportC2172 5 odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-138.9
Evaluation Reports
Other: Uplift load of 138.9 psf @ support spacing of 24" o.c.
FL9555 R4 AE EvaluationReRortC2172 5.pdf
Created by Independent Third Party: Yes
9555.6
PBR Panel
Min. 26 ga., 36" wide, through fastened roof panel over open
steel supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II EvaluationRenortC2172 6.Pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +96/-163
Evaluation Reports
Other: Design loads of 96 & -163 psf at support spacing of
FL9555 R4 AE EvaluationReportC2172 6,pd
20" o.c.
Created by Independent Third Party: Yes
E'aCi( N+2%t
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
I.org/pr/pr app_dti.aspx?param=wGEVXQwtDgtvOROQkZA5RE8EOgziUdi7ntuFlu2jC5sp/o3d. 2/3
uyau Its moncia Buuciinn coae Unllne
mail to this entity. Instr ~';intact the office uy phone or i'iy traditional mail. If you have any c� `is, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statuti -ctive October 1, 2012, licensees licensed under Chapter 455, F.S. _)rovide the Department with an email address If they have
one. The emalls provided msy uc used � for official communication with the licensee. However email addresses are public record. IF you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
® ® 0-70 fL'-k
Credit Card
Safe
https://www.flori�abuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtvOROQkZA5RE8EOgziUd17ntuFIu2jC5s%3d 3/3
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
`26 GA. MASTERRIB PANEV
OVER STEEL SUPPORTS
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 9555.2-R4
STRUCTURAL COMPONENTS
ROOF DECK
Prepared For:
Union Corrugating Company
701 S. King St.
Fayetteville, NC 28301
Telephone: (910) 483-0479
Fax: (910) 483-1091
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
Load Span Table (1 Page)
Report No. C2172-2
Date: 8.20.2017
%%�tile t66E104,
wY C%,�ALIN(,- 4,
o�p
x it C as
L v� zj may.
Manufacturer:
Product Name:
Panel Description:
Union Corrugating Company
MasterRib Panel
36" wide coverage with 3/4" high ribs at 9" o.c.
FL 9555.2-R4
C2172-2
8.20.2017
Page 2 of 3
Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Support Description: Min 16 ga., 50 ksi steel. (Must be designed by others)
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: 47.2 psf @ maximum support spacing of 60" o.c.
(Factor of Safety = 2)
Support Attachment: #12-14 x 1" long self -drilling screws with washers
At end supports @ 3.5"-5.5"-3.5" o.c. across panel width
At intermediate supports @ 9" o.c. across panel width
Sidelap Attachment: '/4"-14 x 7/8" long SDS with washer @ 30" o.c.
Test Standards: Roof assembly tested in accordance with ASTM E1592-01 `Test
Method for Structural Performance of Sheet Metal Roof and Siding
Systems by Uniform Static Air Pressure Difference' and FM 4470
Section 5.5 `Resistance to Foot Traffic'.
Test Equivalency: The test procedure in ASTM E1592-01 comply with test procedure
prescribed in ASTM E1592-05(2012).
The test procedure in FM 4470 (1992) comply with test procedure
prescribed in FM 4470 (2012).
Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. The design uplift pressure for reduced support spacing may
be computed using rational analysis prepared by a Florida Professional
Engineer or based on Union Corrugating load span table. This product
is not approved for use in the High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section 1505 and current approved roofing materials
directory for fire ratings of this product.
FL 9555.2-R4
C2172-2
8.20.2017
Page 3 of 3
Supporting Documents: ASTM E1592 Test Reports
Farabaugh Engineering and Testing Inc.
Project No. T163-06, Reporting Date 6/7/06
FM 4470 Test Report
ENCON Technology Inc.
C1583-2, Reporting Date 7/24/08
INTERIOR SUPPORTS
MIN 16 GA. STEEL —
(DESIGNED BY OTHERS)
END SUPPORTS
MIN 16 GA. STEEL
(DESIGNED BY OTHERS)
MASTERRIB
PANEL
MIN 16 GA. STEEL —
(DESIGNED BY OTHERS)
P�9NEl—FASTENER------ _ --- SEE PANEL SIDELAP
® 9" O.C. DETAIL
i O.C. — MASTERRIB
PANEL r
PANEL FASTENER
3.5"-5.5"-3.5" O.C.
MASTERRIB
PANEL
TYPICAL PANEL INSTALLATION X—SECTION
PANEL FASTENER
® 9" O.C.
SIDELAP FASTENER MASTERRIB
1/4"-14 SDS WITH PANEL
WASHER ® 30" O.C. PANEL FASTENER
#12-14 x 1" LONG
SOS WITH WASHER
MIN 16 GA. STEEL
(DESIGNED BY OTHERS)
PANEL SIDELAP
SIDELAP FASTENER
@ 30" O.C.
MAX 60" O.C.
(SEE LOAD SPAN TABLE FOR
ALLOWABLE LOADS AND SPANS)
SECTION VIEW
SIDELAP FASTENER
® 30" O.C.
SIDELAP FASTENER
® 30" O.C.
PANEL FASTENER
3.5"-5.5"-3.5" O.C.
GENERAL NOTES:
1. ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA
BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE 26 GA. (t = 0.017"). EFFECTIVE COVERING WIDTH
OF PANEL = 36".
3. ROOF PANELS SHALL BE INSTALLED OVER STRUCTURE AS SPECIFIED ON THIS
DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT.
THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE DESIGN LOADS.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL
6. SUPPORTS MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
7. PANELS MAY SPAN BETWEEN EAVE TO RIDGE SUPPORTS OR RAKE TO RAKE
SUPPORTS.
U O
U WNN
z�
Q SUN
V, Z ,
Z00
Ljlo
U U)�yjO
Lc
1 OF 1
_ UNION CORRUGATING COMPANY
MasterRib Roof Panel
36" wide, 26 ga. (ruin) Steel Panel over Steel Supports
Span
Loading
Allowable Load (psi)
Support Spacing (ft)
Condition
'Type
1.50
1.75
2.00
2.50
3.00
3.50 1
4.00
4.50
5.00
Two Span
Uplift
138.3
118.5
103.7
83.0
69.2
59.3
51.9
46.1
37.7
Three Span
ill
Uplift
157.2
134.7
117.9
94.3 -
78.6
-----
67.4
58.9
52.4
-
47.2
--.-----
11 Four ro M More e
------
Uplift
151.3
129.6
--
113.4
90.8
75.6
64.8
56.7
50.4
44.1
Spans
III
I otes:
i
Allowable load for each condition is the smallest load calculated based on fastener capacity, panel
strength
and
II and deflection. limit of L/180. Allowable loads are calculated for minimum 26 ga. panel.
i 11e W111U WdU 15 LUMC11 Ub V. / U1UG5 ULU 1iV111t.IVLLG111. CW1U vrauuluy lv - uav F-1- .......•............. 1, .-..••.. -
The panel allowable properties are determined from full scale ASTM E1592 tests at 5' 0" span
The panel fasteners are M12-14 x 1" long self drilling screws with washers. Fastener spacing across panel width
is 9.0" o.c. in the interior supports and 3.5"-5.5"-3.5" o.c. at panel ends.
Sidelap fasteners are 1/4"-14 x 7/8" long self drilling screws with washer at 30" o.c.
Steel supports are minimum 16 ga. All supports must be designed to resist all loads imposed on the panel.
The panels may span from eave to ridge or rake to rake.
Panels must be installed as per Evaluation Report FL 9555.2 and Union current installation procedure.
1216 Lansing Ave., Suite C
Tulsa, OK 74106
918 4 ,2 5992
ItttIIa0Plite,
• OF
90 °
h v,.
l-7
limit.
Bala Sockalingam, Ph.D., P.E.
PE 62240
1/9/20 ,i8 Florida Building Code Online
ProfessionafRegulafloil
pprr
8CIS Home Log In User Registration Hot Topics Submit Surcharge Stats SL Facts Publications FBC Staff BCIS Site Map Linics Search
Approval
USER: Public Userr
Product A4 npnii Nano > PIIWuO or Application Search > Aoolication list > Application Detail
FL # FL9555-R4
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST.
FAYETTEVILLE, NC 28301
(910) 483-0479 Ext256
jstieby@unioncorrugating.com
Authorized Signature John Stieby
jstieby@unioncorrugating.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Structural Components
Subcategory
Roof Deck
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
-: Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Bala Sockalingam
the Evaluation Report
Florida License
PE-62240
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
09/07/2027
Validated By
Yoosef Lavi, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
FL9555 R4 COI CertlflcateIndeoendence.odf
Referenced Standard and Year (of Standard)
Standard Year
ASTM E1592 2005
FM 4470 2012
Equivalence of Product Standards
Certified By
Sections from the Code
.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtvOROQkZA5REBEOgziUdl7ntuFlu2jC5s%3d 1/3
Product Approval Method
Florida Building Code Online
Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
08/23/2017
08/28/2017
09/09/2017
12/12/2017
FL # N1ode1, Plumber or Name Description
9555.1 SV Panel 29 ga., 24" wide, through fastened panel over wood supports
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9555 R4 II EvaluationRenortC2172 1,adf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design pressure: +N/A/-70.25 Evaluation Reports
Other: Uplift load of 70.25 psf @ support spacing of 24" o.c. FL9555 R4 AE EvaluationReoOrtC2172 1.odf
Created by Independent Third Party: Yes
9555.2 1MasterRib Panel
26 ga., 36" wide, through fastened panel over steel supports
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9555 R4 II EvalualionReoortC2172 2.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design pressure: +N/A/-47.2 Evaluation Reports
Other: Uplift load of 47.2 psf @ support spacing of 60" o.c. FL9555 R4 AE EvaluationReoortC2172 2.odf
Created by Independent Third Party: Yes
9555.3 1 MasterRib Panel
29 ga., 36" wide, through fastened panel over steel supports
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9555 R4 II EyaluationReoortC2172 3.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design pressure: +27.1/-37.7 Evaluation Reports
Other: Design load of 27.1 & -37.7 psf at support spacing of FL9555 R4 AE EvaluationReoortC2172 3.{Ldf
48" o.c. Created by Independent Third Party: Yes
9555.4 1 MasterRib Panel
29 ga., 36" wide, through fastened panel over wood supports
Limits of Use InstallationInstructions
Approved for use in HVHZ: No FL9555 R4 IT Eva luationReoortC2172 4.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design pressure: +27.1/-36.2 Evaluation Reports
Other: Design load of 27.1 & -36.2 psf at support spacing of FL9555 R4 AE EvaluatlonReoortC2172 4,ndf
48" o.c. Created by Independent Third Party: Yes
9555.5 1 MasterRib Panel
29 ga., 36" wide, through fastened panel over nom. 1" x 4"
woad supports
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9555 R4 II EvaluationReoortC2172 5.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design pressure: +N/A/-138.9 Evaluation Reports
Other: Uplift load of 138.9 psf @ support spacing of 24" o.c. FL9555 R4 AE Evaluat(onReoortC2172 5.odf
Created by Independent Third Party: Yes
9559.6 1 PBR Panel
Min. 26 ga., 36" wide, through fastened roof panel over open
steel supports
Limits of Use Installation Instructions
Approved for use in HVHZ: No FI 9555 R4 I1 EvaluatfonReoortQ2172 6.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design pressure: +96/-163 Evaluation Reports
Other: Design loads of 96 & -163 psf at support spacing of FL9555 R4 AE EvaluatlonReQortC2172 6.odf
20" o.c. Created by Independent Third Party: Yes
Dock Nest
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
2/3
Florida Building Code Online
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click ere.
Product Approval Accepts:
= IM-EW =CtCJ M
Credit Card
Safe
3/3
E1%ALUATION REPORT OF
UNION CORRUGATING COMPANY
`29 GA. 5N' PANEL"
OVER WOOD SUPPOWfS
FLORIDA BUILDING COVE 6'TII EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 9555.1-R4
STRUCTURAL COMPONENTS
ROOF DECK
Prepared For:
Union. Corrugating Company
P. O. Bow; 229
Fayetteville, NC 28302
Telephone: (910) 483-0479
Fax: (910) 483-8897
Prepared By:
Bala Socltalingarn, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OIL 74106
Telephone: (918) 492-5992
FAY: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (I Page)
Report No. C2172-1
Date: 8.20.2017
b`gjgBlOBtttttt�
b`gti��OGKA L d /1,rG,q�P,o
oar: •� �22�0 •
® o
n �o
V
m F F CLU
s
I • O • Lij Z
`•ice"°• OPi
'4
�tj.2a ,2G t'-2
FL 9555.1-R4
C2172-1
8.20.2017
Page 2 of 3
Manufacturer: Union Corrugating Company
Product Name: 5V Panel
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Minimum 29 ga.,180 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Support Description: Nom. 1" x 4" (min) lumber (Southern Yellow Pine Untreated)
(Must be designed by others)
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: 70.25 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2) (3 or more spans)
Panel Attachment: #9-15 or #10-14 x 1-1/2" long wood screws with washer
At panel ends @ 12" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with ASTM E1592-01 `Test
Method for Structural Performance of Sheet Metal Roof and Siding
Systems by Uniform Static Air Pressure Difference' and FM 4470
Section 5.5 `Resistance to Foot Traffic'.
Test Equivalency: The test procedure - in ASTM E1592-01 comply with test procedure
prescribed in ASTM E1592-05(2012).
The test procedure iin FM 4470 (1992) comply with test procedure
prescribed in FM 4470 (2012).
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design., The maximum support spacing listed herein shall not be
exceeded. The design uplift pressure for reduced support spacing may
be computed using rational analysis prepared by a Florida Professional
Engineer. This product is not approved for use in the High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2017 Section 1505 and current
approved roofmg materials directory for fire ratings of this product.
FL 9555.1-R4
C2172-1
8.20.2017
Page 3 of 3
Supporting Documents: ASTM E1592 Test Report
Farabaugh Engineering and Testing Inc
Project No. T246-06, Revised Reporting Date 11/7/06
FM 4470 Test Report
ENCON Technology Inc
C1583-3, Reporting Date 7/24/08
12'
PANEL FASTENER
#9-15 OR #10-14 X 1.5" LONG WOOD
SCREWS @ MAX 12" O.C.
FASTENER PATTERN
SUPPORT SPACING = 24" O.C.
ALLOWABLE UPLIFT PRESSURE = 70.25 PSF
24'
5V Panel Profile
Minimum 29 Gauge. Minimum Yield - 80 KSI
NOM. 1 " X 4" (MIN)
SYP UNTREATED
(DESIGN BY OTHERS) m
1/2'T
m
a
>rc%
Sheet No.