Loading...
HomeMy WebLinkAboutEVALUATION REPORT�p NEMO etc. SCANNED Certificate of Authorization #32455 BY 353 Christian Street, Unit #13 s lade county Oxford, CT 06478 I� (203) 262-9245 NGINEER EVALUATE TEST CONSULT CERTIFY EVALU ,TION REPORT Polygla°s USA, Inc. Evaluation Report P12060.02.09-R24 1111 hest Newport Center Drive FL5259-R28 Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009 (954) 2t 3-1230 Revision 24: 01/24/2018 SCOPE: This E aluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of constr 'ction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6t Edition 2017 Florida Buildin Code sections noted herein. �I LABELIN : Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the produ (s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this Evalua ion Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "MEMO l etc. Evaluated" may be displayed in adverti I ing literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECT 'ION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distribi, hors and shall be available for inspection at the job site at the request of the Building Official. This Ev„ luation Report consists of pages 1 through 14. Prepared by: Robe !U.M. Nieminen, P.E. Florida „egistration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 01/24/2018. This does not serve as an electronically signed document. CERTIFICII' TION OF INDEPENDENCE: 1. NEMOIetc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or disl ributing products it evaluates. 2. NE O I etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Rol' lert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Rot'pert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. Thin is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING; 1. 2. 3. i v � ONEMOletc. EVALUATION: duct Category: Roofing b-Category: Underlayment mpliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the lowing sections of the 6 E ition 201�7 F on a Bui in Code through testing in accordance with the following Standards. mpliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Jon Property Standard Year 1.3.1 Wind Uplift FM 4474 2011 13.1 Wind Uplift UL 1897 2012 7.2.3 / 1507.1.1 Physical Properties ASTM D226 2009 1.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 7.3.3 Physical Properties FRSA/TRI April 2012 2012 7.11.2 Physical Properties ASTM D6164 2011 7.11.2 Physical Properties ASTM D6222 2011 110 Accelerated Weathering ASTM D4798 2011 ntt1t V Examination Reference Date M Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 RI (TST 5878) Physical Properties PRIO1111 04/08/2002 RI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 RI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 RI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 RI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 RI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 RI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 RI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 RI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 RI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 RI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 RI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 RI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 RI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 1TI (TST 2508) Physical Properties JX201-17A 04/01/2008 ITI (TST 2508) Physical Properties RX14E8A 01/29/2009 RD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 RD (TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 RD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 RD (TST 6049) Physical Properties 02200.07.03 07/14/2003 RD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 RD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 RD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 RD (TST 6049) Physical Properties P13450.08.09 08/13/2009 RD (TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 RD (TST 6049) Physical Properties P11030.11.09-1 11/30/2009 RD (TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 RD (TST 6049) Physical Properties P11030.11.09-3 11/30/2009 RD (TST 6049) Physical Properties P33360.06.10 06/25/2010 RD (TST 6049) Physical Properties P33370.03.11 03/02/2011 RD (TST 6049) Physical Properties P33370.04.11 04/26/2011 RD (TST 6049) Physical Properties P37300.10.11 10/19/2011 ETC, I.I.C. Evaluation Report P12060.02.09-R24 to of Authorization ✓132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 2 of 14 4. ONEMOjetc. roxity Examination Reference Date RD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012 RD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012 RD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012 RD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 RD (TST 6049) Physical Properties P45370.04.13 04/26/2013 RD (TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 RD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 RD (TST 6049) Wind Uplift P41630.08.13 08/06/2013 RD (TST 6049) Wind Uplift P11751.05.03-R3 11/26/2013 RD (TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 RD (TST 6049) Physical Properties P45270.05.14 05/12/2014 1RD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014 RD (TST 6049) Physical Properties 6020.09.14-2 09/08/2014 RD (TST 6049) Physical Properties 6020.09.14-3 09/08/2014 RD (TST 6049) Physical Properties 6020.09.14-4 09/08/2014 RD (TST 6049) Physical Properties 6020.09.14-5 09/08/2014 RD (TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ,�RD (TST 6049) Physical Properties P46520.10.14 10/03/2014 RD (TST 6049) Physical Properties P43290.10.14 10/17/2014 RD (TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 RD (TST 6049) Physical Properties P40390.04.15 04/03/2015 RD (TST 6049) Physical Properties P44360.10.14-R1 05/18/2015 RD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015 RD (TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 RD (TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 RD (TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 RD (TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016 RD (TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017 RD (TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017 CC -ES (EVL 2396) IBC Compliance ESR-1697 11/01/2014 iami-Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 lolyglass USA Manufacturing Affidavit Products Current 02/18/2009 olyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 olyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 L, LLC. (QUA9625) Quality Control Service Confirmation Exp. 10/05/2018 I RODUCT DESCRIPTION: :1 Mechanically Fastened Underlayments - 1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 1.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. II l .1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet. .1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. 4.2', SeWAdhering Underlayments C2.1 Polystick MTS or Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass �i fiber reinforced, surfaced with polyolefinic film surface; meets FRSA/TRI April 2012. 1 .2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. ETC, I.I.C. Evaluation Report P12060.02.09-R24 to ofAuthorizotion #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 3 of 14 ii fONEMOJetc. 12.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets FRSA/TRI April 2012. ->i i 2.5 Po stir TU Max is a nomina 1160-m t Ic ru erized as a t water roo in membrane wit a 19 m2 o ester a ric su ace; meets ASTM 01970 and F.RSA RI A ri 2012. L2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012. S. 2.7 Polystick Dual ProTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970. 2.8 Polystick Tile ProTm is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section 5.8). 3 Mechanical(y,_,Fastened'and/or Bonded Underlayments 3.1 Elastoflex G TU is a polyester reinforced, modified bitumen the underlayment composed of a sand -surfaced SBS modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 04-12 beneath mechanical) fastened the roofs stems or Hot Asphalt applied "Ca Sheet" in the "Two PI � ( ) Y Y P PP� P Y System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems. .2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164. Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems. .3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems. Polyflex G FR is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. .1 This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. .2 This Evaluation Report is not for use in the HVHZ. .3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. .4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. ETC, I.I.C. Evaluation Report P12060.02.09-R24 to of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 4 of 14 I ONEMOjetc. .5 Allowable Roof Covers: .I !; TABLE 1'.100F,COVER OPTIONS" , . nderlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes o WShingles Slate lastobase Yes Yes (Base Sheet In 2-ply system) Yes (Base Sheet in 2-ply system) Yes Yes Yes lastobase P Yes Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) Yes Yes Yes �olyglass G2 Base it No Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) No No No Ilolyglass APP Base 11 No Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) No No No olystick MTS or MTS PLUS Yes Yes No Yes Yes Yes olystick IR-Xe Yes No No No Yes Yes plystick TU P No Yes Yes (See 5.5.1) No No No olystickTU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes o stic TU Ma No es Yes (See 5.5.1) Yes No No „olystick Dual Pro Yes No No Yes Yes Yes ,'olystickTile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes olystick MU-X Yes No No Yes Yes Yes lastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes lastoflex S6 G FR Yes Yes No No Yes Yes lastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes „olyflex G Yes Yes Yes (See 5.5.1) No Yes Yes „olyflex G FR Yes Yes No No Yes Yes „olyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes ule-Hide SA-APP Cap Sheet 1r SA-APP Cap Sheet (FR) Yes Yes Yes (See 5.5.1) No Yes Yes I 1.5.1 "Foam -On Tile" is limited to use of the following Approved the adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE UNDERLAYMENT COMBINATIONS) Adhesive Florida Product Underlayments Approval AP Foam Touch 'n Seal StormBond Roof rile Adhesive FL14506 Polystick TU Plus, Polystick TU Max ow TileBond" FL22525 Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, CP Adhesives Polyset® AH-160 FL6332 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) j Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, CP Adhesives Polyset® RTA-1 FL6276 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, I; I I Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. ETC, LLC. Evaluation Report P12060.02.09-R24 to of Authorization N32455 6t" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 5 of 14 .1 WNEMOletc. Allowable Substrates: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete. Bond -to -Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. .3 Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied to: ➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. ETC, U.C. Evaluation Report P12060.02.09-R24 to of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (04) 233-1230 Revision 24: 01/24/2018 Page 6 of 14 ONEMOletc. .4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. -> !7 Ex osure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation. P.O vstic MILS, MTfS PLUS, TiU P. TiU P. us, TLU Max, OUaliPro�TiilelPr,o or Elastofl-,,aQkTLIBrhall n llblleft exp ededifor, Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. Tile Slippage Limitations (FRSA/TRI April 2012 (04-12)1: When loading roof tiles on the underlayment in direct -deck the assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS' J nderlayment Tile Profile Staging Method Maximum Slope lastoflex G TU it Flat 10-tile stack 7:12 Lugged 8-tile stack (6 over 2) 6:12 lastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 olystick MTS or MTS PLUS Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 olystick Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 � olystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lu a 10-ti a star 612 it olystick TU P Flat 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 4:12 I olystick TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12 ETC, I.I.C. Evaluation Report P12060.02.09-R24 to of Authorization #32455 6P EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 11 of 14 6. N ONEMOletc. INSTALLATION: 1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. .2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). Elasstobase - astobase P or'Mule Hide Nail Base 3.1 Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or ii Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. .3.2 Tile Applications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual. Po tr - TS; MTSP.LUS, IR=Xe, TU P, TU Plus TU Max Dual Pro, Tile Pr`o or MU=)( or, Polyflex SAP, Polyflex SAP` FR; - . ide.SA-APP,Cap'Sheet or Mule -Hide SA=AP ap Sheet (FR):, .4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 5.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers: All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP I, Cap Sheet or SA-APP Cap Sheet (FR) , Quid be back -nailed in selva e e e seam in accordance wit Po ass Mu e- lameter meta I rd Is RUE Im 13 1 ex- a meta I eap nai , at a minimum rate o 1 o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back -nailed. All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Ovelap Seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details ETC, LLC. Evaluation Report P12060.02.09-R24 to of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ8 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 12 of 14 ONEMOjetc. Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 3.4.j Tile ADDlications (not allowed for Polystick Dual Pro, IR-Xe or Polystick Mu-X): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012,(04-12), Table 1. For adhesive -set the applications, refer to Section 5.6.4 herein. .4.4 Two (2) Ply Underlayment Systems: Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. i.5 .Elastoflex.G TU, Elastoflex,S6"G or Elastoflex S6 G FR: .5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single 11 Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems or the Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet' in the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6 6 Polyflex G or,;Polyflex G FR 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in the applications: ✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2022 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet' in the 'Two Ply System" -from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3). ETC, LLC. Evaluation Report P12060.02.09-1124 to of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 13 of 14 I ONEMOjetc. .6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. �117 Tile Staging: 11. 7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Polyglass published requirements for tile staging. (117.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail - boards, to prevent tile sliding and/or damage to the underlayment during the loading process. .7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. i 7. 1 WILDING PERMIT REQUIREMENTS: is required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. ANUFACTURING PLANTS: II !ontact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following slants have qualified products under their respective physical properties specifications. Plant 5becificatiorr_ Products . 111'ernley, NV, Hazleton, PA & Winter Haven, FL ASTM D1970 Polystick MU-X I!Hazleton, PA M-D 13-0004 Elastoflex G TU II Hazleton, PA & Winter Haven, FL ASTM D1970 Polystick IR-Xe ASTM D1970 & FRSA/TRI April 2012 Polystick TU Plus ASTM D1970 & FRSA/TRI April 2012 Polystick TU Max IiTuscaloosa, AL ASTM D4601, Type II Polyglass G2 Base Winter Haven, FL ASTM D226 (physicals) Elastobase, Elastobase P ASTM D6509 Polyglass APP Base FRSA/TRI April 2012 Polystick MTS, Polystick MTS PLUS FRSA/TRI April 2012 Polystick TU P FRSA/TRI April 2012 Polyflex SAP, Polyflex SA P FR ASTM D1970 Polystick Dual Pro ASTM D1970 & FRSA/TRI April 2012 Polystick Tile Pro ASTM D6164 Elastoflex S6, Elastoflex S6 G FR ASTM D6222 Polyflex G, Polyflex G FR 9. hUALITY ASSURANCE ENTITY: L, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - ETC, U.C. Evaluation Report P12060.02.09-R24 ,te of Authorization #32455 6r" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 14 of 14