Loading...
HomeMy WebLinkAboutSOIL NUCLEAR GAUGE0 Port St. Lucia FBPE CA # 4930 521 NW Enterprise Drive Part St. Lucie. FL 34986 Phone: 772-924-35751 Fax: 772-924-3580 Soil Nuclear Gauge Report Date: 4/3/2017 Test Method: ASTM D 6938 Client: Phoenix Realty Homes, Inc. 1760 North Jog Road, Suite 120 West Palm Beach, FL 33411 Project: 16-1614.00 121 Queen Gunevier Court Fort Pierce, Florida Test Results Test At Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. (%) Remark 1 3/28/17 P-1 N/A 10.4 117.1 8.0 114.5 12 98 95 / 105 Pass 2 3/28117 P-1 N/A 10.4 117.1 6.4 115.8 12 99 95 / 105 Pass 3 3/28117 P-1 N/A 1 10.4 1 117.1 1 7.8 1 114.6 1 12 1 98 1 95 / 105 1 Pass 4 3/28117 P-2 N/A 12.0 103.1 5.3 101.5 12 98 95 / 105 Pass 5 3/28/17 P-2 NIA 12.0 103.1 7.3 99.4 12 96 95 / 105 Pass 6 3/28/17 P-2 N/A 12.0 103.1 7.1 99.1 12 96 95 / 105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN Field Technician 1 Below Slab Grade: Foundation pad, center 0-1 Troxler 3430 26474 Grimes, John 2 Below Slab Grade: Foundation pad, northwest corner 0-1 Troxler 3430 26474 Grimes, John 3 Below Slab Grade: Foundation pad, southeast comer 0-1 Troxler 3430 26474 Grimes, John 4 Below Bottom of Footing: Footing, east side 1-2 Troxler 3430 34907 Grimes, John 5 Below Bottom of Footing: Footing, west side 1-2 Troxler 3430 34907 Grimes, John 6 Below Bottom of Footing: Footing, north side 1 11-2 Troxler 3430 34907 1 Grimes, John Remarks Comments Pass: Tests results comply with specifications Tests are 'Direct Transmission' (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. �eee,L�af7Wi�� ee e•` "�� APPROVED �P _� ve,�O .'•AGE • • F<����i � �� m �" ` 0675 045/p17 4 4 • Donald VVNoler, Pi -p rofoq lI"l E gine2P#$0675 0�6ia�€�ofFRrtc�Q'• •�� o�` JSS' 4e �ONALE�.,� 'r1rror010%e Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document_are_not_considered_signed d -and sealeaadihe signaturrnlst beerified on anyetectronio copies. Page 1 of 1 T NA'nON Delray Beach FBPE CA # 4930 1215 Wallace Drive Delray Beach, FL 33444 Phone: 561-347-66701 Fax: 561-395.5805 Client: Project: Report Date: 4/3/2017 Phoenix Realty Homes, Inc. 16-1614.00 Test Method: ASTM D 6938 1760 North Jog Road, Suite 120 121 Queen Gunevier Court West Palm Beach, FL 33411 Fort Pierce Florida Soil Nuclear Gauge Results: .. Test d Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) Probe Depth (In) Percent Compaction Min/Max Comp. e ( /o) Remark 1 3/28/17 PA N/A 10.4 117.1 8.0 114:5 12 98 95 / 105 Pass 2 3/28/17 P-1 N/A 10.4 117.1 6.A 115.8 12 99 95 / 105 Pass 3 3/28117 P-1 N/A 10A 117.1 7.8 114.6 12 98 951105 Pass 4 3128117 P-2 NIA 12.0 103.1 5.3 101.5 12 98 95 / 105 Pass 5 3128/17 P-2 NIA 12.0 103.1 7.3 99.4 12 96 951105 Pass 6 3/28/17 P-2 NIA 12.0 103.1 7.1 99.1 12 96 95/105 Pass 1 . 'Test Information' Test # Test Location Elevation Reference Gauge Make / Model / SN Field Technician 1 Below Slab Grade: Foundation pad, center 0-1 Troxler 3430 26474 Grimes, John 2 Below Slab Grade: Foundation pad, northwest corner 0-1 Troxler 3430 26.474 Grimes, John 3 Below Slab Grade: Foundation"pad, southeast corner 0-1 Troxler 343026474 Grimes, John 4 Below Bottom of Footing: Footing, east side 1-2 Troxler 3430 34907 Grimes, John 5 1 Below Bottom of Footing: Footing, west side 1-2 Troxier 3430 34907 Grimes, John 6 jBelow Bottom of Footing: Footing, north side 1-2 Troxler 3430 34907 lGrimes, John Remarks: P Comments . k Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth Is noted as "Backscatter".'Gauge calibration data on file with the testing agency. Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. and sealed and the signature must be verified on any electronic ///1Ilill0 0 /612 03 Soil Nuclear Gauge I';I Client: Project- rReport Date: 4/3/2017 Phoenix Realty. Homes, Inc. 16-1614.00 y4�e Test Method: ASTM D 6938 1760 North Jog Road, Suite 120 121 Queen Gunevier Court Delray Beach West Palm Beach, FL 33411 Fort Pierce, Florida FBPE CA @ 4930 1216 waeace Drive Delray 0.0, FL 33444 Phoon: 561.347.00701 Fen: 561-395.5805 Test, Results„ Optimum Maximum In Place In Place Probe MinlMax Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Comp. II Test# Of Date Proctor ID Method Classification (% (pcf) (% pcf) in Compaction % Remark 1 3128/17 P-1 NIA 10.4 117.1 8.0 114.5 12 98 951105 Pass 2 3/28/17 P-1 N/A 10.4 117.1 6.4 115.8 12 99 95/105 Pass 3 3128117 P-1 NIA 10.4 117.1 7:8 114.6 12 98 951105 Pass 4 3128A7 1 12 N/A 12.0 103.1 5.3 101.5 12 98 951105 5 3/28I17 - P-2 NIA 12:0 103.1 7,3. 99.4 12 961 951105 Passe 6 3/28/17 P-2 NIA 12.0 103.1 7.1 99.1 12 96 95 / 105 Pass Testlnformatiom, Gauge �. Test # Test Location Elevation Reference Make !.Model / SN Fleld Technician 1 Below Slab Grade: Foundation pad, center 0-1 Troxler 3430 26474 Grimes, John 2 Below Slab Grade: Foundation pad, northwest corner 0-1 Troxler 3430 Grimes, John 3 Below Slab Grade: Foundation, pad. southeast corner 0-1 Troxler 3430 26474 Grimes, John II 4 Below Bottom of Footing: Footing, east side 1-2 Troxler 3430 34907 Grimes, John I, 5 Below Bottom of Footing: Footing, west side 1-2 Troxler 3430 34907 Grimes, John �I 6 1 Below Bottom of Fooling: Footing, north side 1 11-2 1 Troxler 3430 34907 - Grimes, John -Remarks "Comments- Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth Is noted as °Backscatler". Gauge earbrallon data on file with the testing agency. i REF Rso;;r , ,4-: M .. �' Test Reports shall not be reproduced, except in full, without the written approval of UVA international Inc. �i i i I t I tt NG I�� Wi of Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. /%r t� 14