Loading...
HomeMy WebLinkAboutENGINEERING3 IL FIN�Ur I ------- ST LUCIE COUNTY LJ ,SCANNED BUILDING DIVISION ��y FOR COMP CE gT PUBLIC yy0 St" Lucie Countv REVIEWED BY 5'-0" O.C. 4'-0" �t� �""T'• FL I DATE -0" MAX SPACING 25'-9' DOOR END ._W-4- DOOR END 4'-0" O.C, '-p PLANS AND PERMIT MAX - 22-9- D006A START � 13Y-4' DOOR START MAX MAx Acrarr I -BEAM O INSP LC B F - - - - - - .T. 2 X8 ROOD CAP ❑0 ❑ G: ❑ .Z p❑T €.. - .. O❑ LF-TT - ❑ ❑❑ 7 �� F.: F ❑❑ 0 Ft-01 G FACTORY I- 4' THICI( soup BLOCK cAP '-OTYP �• •ter 8•X6'X16' CONCRETE iV MAX'-6'-6" MAX A - MASONRY UNITS F-1 6'-6" MAX MAX SINGLE -STACKED) Q I Q o B'X8'X16' CONCRETE •• �. ASONRY UNITS ••4•;• FACTORY I- ',�.•y: (SNGLE-STACKED) a :. �:� F.T. T p F.T. F.T. •,.i.. .�.•"!t G. F. T, F G.A G.A. A PIER "A" ,. L ❑ ❑ Q ALT. G - 'Z. �o A ❑❑ G ' ❑ -® �.;� : J%'..; F'1 11I i.;, • 0 c 4'-0" O.C. '-0 n• X 22' MAX 5'-0" O.C. F-1 B MAX MAX ` GRADE WITH WAM PAD GRADE MAX SPACING �•--B_NL POLYETHYLENE 18' X le F-1 FILM NOTE. PIER TYPE 'A' HAS A SS PAD TYPE '8' HAS A MAXIMUM HEIGHT OF 38' FROM NOTE.MAXIMUM HEIGHT OF 64" FROM GRADE TO TOP OF P.T. 2 X 8 ,,,,•„- -„ STRUCTURAL LOAD LIMITATIONS: CODE EDITION: 2010 FLORIDA BUILDING CODE BASCE7.10 1. ULTIMATE DESIGNWID SPEED: 170 mph WIND SPEED 2. NOMINAL DESIGN WINO SPEED: 132 mph WINDSPEEO 3. WIND EXPOSURE CATEGORY: 'C" A. IMPORTANCE FACTOR: 1� 6. INTERNAL PRESSURES: s26.9 -28A INTERIOR •2S9 4H.6 END 6. DESIGN ROOFLNELOAD: 20 PSF T. DESIGN FLO OR LIVE LOAD: m PSF 8. MIN. ASSUMED SOIL BEARING CAPACITY: IOMPSF 9. O CCUPANCY CLASSIFICATION: R3 10. CONSTRUCTIONTYPE: VB 11. THIS BUILDING IS NOT DESIGNED FORPLACEAEJTINA HIGH VELOCITY HURRICANE ZONE AS DEFINED BYTHE FBC. 12. THIS BUILDING IS NOT DESIGNEDTO BESDTMERGEDOR SUBJECTED TO WAVE ACTION WHEN LOCATE) INA FLOOD PRONE OR ZONE AREA. THE BOTTOM OFTHE STRUCTURAL ,.BEAM MUST BE LOCATED ABOVE TESULDING SITE FLOOD PLANE LEVEL FOR THIS BUILDING TO BE LOCATED W A FLOOD PRONE OR ZONE AREA OR THE THE GRADEATTHE BUILDING SITE MUST BE ABOVE THE FLOOD PLANE LEVEL LEGEND 16'X16' ABS PAD =1785 LBS. CAPACITY ® 17"1Q2" ASS PAD = 2500 LBS. CAPACITY SYMBOLS F.T. -FRAME TIE -DOWN FASTENED TO G.A. GROUND ANCHOR. Q -OLIVER TECHNOLOGIES OR EQUIVALENT LONGITUDINAL 81 TRANSVERSE BRACING SYSTEM ®-OLIVER TECHNOLOGIES OR EQUIV. LONGITUDINAL BRACING SYSTEM ONLY FOUDATION NOTES: 1. BLOCKING SPACING BASED ON 20PSF LIVE LOAD ON ROOF AND 1000 PSF SOIL BEARING CAPACITY. 2. CONCRETE BLOCKS ARE ONLY RATED AT 8000 POUNDS, 8000 POUND PIERS OR HIGHER MUST BE DOUBLE BLOCKED. 3. STABILIZER SYSTEM PER OLIVER TECHNOLOGIES, INC., OR EQUIVALENTAND ALL SIDEWALL ANCHORS ARE SPACED PER PLAN. FOUR FOOT GROUND ANCHOR MAY BE USED. 4. THE MODEL 1101-f(LONGITUDINAL 8 LATERAL PROTECTION) ELIMINATES THE NEED FOR MOST STABILIZER PLATES AND FRAME TIES. EACH SYSTEM IS REQUIRED TO HAVE A FRAME TIE AND STABILIZER ATTACHED AT EACH LATERAL ARM STABILIZING LOCATION. THIS FRAME TIE AND STABILIZER PLATE MUST BE LOCATED WITHIN 18' FROM CENTER OF GROUND PAN. 5. WOOD SHIMS MAY BE INSTALLED WHEN NECESSARY BETWEEN THE I -BEAM AND THE TOP OF THE PIER. SHIMS SHALL BE FREE OF KNOTS, SPLITS, AND SIMILAR IMPERFECTIONS. SHIMS SHALL BE OF P.T. LUMBER, CEDAR, DRABS AND BEARG AT ALL CONTACT POINTS SHALL NOT BE LESS THAN 2(3 OF THE BEARING PRIOR TO ADDING THE SHIMS. =B=AI:LT)E.DOWN:ANCHOR&SHALtHAVE-A-MINIMUM-472SU W- ACFYAND'SAA[tBl1bSTAfEEDPER?HENIANUFACTUFER3SPECIFICA7(OAS. 7. THE STEEL FRAME OF HOME IS NOT FOR USE OF RELOCATION OF HOME AFTER SETUP, AND IS INTENDED FOR USE AS A PERMANENT FOUNDA 8. ALL PIERS SHALL BE CONSTRUCTED OF 8' X 6" X 16' CONCRETE MASONRY UNITS CONFORMING TO ASTM C90. 9INSTALL BLOCK PIER ON EACH SIDE OF ALL EXTERIOR DOOR OPENINGS. 16. I -BEAM SUPPORT PIERS MAY BE INSTALLED LATERALLY (90 DEGREES FROM THE ORIENTATION SHOWN ON THE FOUNDATION PLAN). MUST BE LOCATED DIRECTLY BELOW THE I•BEAM CENTERLINE 11. ALL MASONRY PIERS MAY BE INSTALLED IN A DRY STACK SUBJECT TO LOCAL JURISDICTION THE FOUNDATION IS DESIGNED TO RESIST FLOTATION, COLLAPSE, AND LATERAL MOVEMENT DUE TO THE EFFECTS OF WIND AND WATER LOADS, AND ALL OTHER LOADS DURING THE BASE FLOOD. IN ADDITION, THE FOUNDATION IS DESIGNED TO PROVIDE RESISTANCE TO UPLIFT AND,OVERTURNING OF THE HOME DUE TO FLOOD AND WIND FORCES AT THE BASE FLOOD. FLOOD ZONE INFORMATION �r -- TIE DOWN STRAP INSTALLATION (OPTION) 2. 1� -GRADING UNDER THE HOME SHALL BE CROWNED TO (� DEWALL PROVIDE POSITWE SLOPE TO EXTERIOR OF HOME. �+� 1-3/B' �I 7/16' HOLE -+ - FEMA MAP INDICATES THAT THIS LOT IS IN A FLOOD ZONE roIAUEEFJt) A -LOT SITE GROUND (ESTABLISHED) ELEVATIONS ARE 18.6. 1-1/4' t-Ile AND 18.8' S/B• -MINIMUM ELEVATION AT BOTTOM OF I -BEAM TO BE 21.8' 1/2' ALL TIE -DOWN STRAPS. ETC.. SHALL BE TYPE 1 2 x 6 FLOOR JOIST FINISH B. GRADE 1, STEEL STRAPPING 109.000 MINIMUM YIDD SMENIH, .OW NINNUM THICKNESS IDEWALL 11EDOWN STRAP (PLUS OR Mows .002 N. - 0.05MN) FINISHPED ZINC 5/16' X 3' FULL THREAD LAGS G (AM STANiDARD tj2yp3�g�� THRU BRACKET INTO OUTER MOST PER OUNCES SOUNM FOOT, PER SURFACE. 4750 RIM JOIST AT EXTERIOR WALLS. POUNDS MINIMUM BREAK STENGTH. MARKED EVERY 12 TO 18 OkH6 (MINUFAC. ME NAME I AND ASTM SPEC. 0�95]-91), 1 1/4' VADTH. OEIYALL EDt:Y/ALL GROUND ANCHOR INSTALLATION TIEDOWNS-4•-Or O.C, TIEDOWNS-4'-0' 0.G BRACKET FASTENED TO PERNETER RAIL W /, tToOD SOREYRS MN. 1PEFILTRAnON WITH LON. 14 SCRLIYS OR 50% SCRERMOLES E OUTRIGGER FlLLm, EVENLY SPACED, BLOCKS D FLOORJOISTS (CHED) 2XS . MN. PERIMETER RAG. . L FRANE ALL TIE-OOXTI STRAPS. ETC.. SHALL BE TYPE 1 B GRADER STEEL .STRAPPING 109,000H!CK L 2X8 V/OOD SHIM MIOSI uINNuu TIED smEemL .o3s' MINIMUM iRCA01Ess (PLUS OR MNUS .002 9L - O.OSYM) I i a FINISH B - HOT-O PPED GALVANIZED ZINC .. NXunuD AsrM STANDARD 123-69A..0 ` DRY STACKED Q (SINGLE-STACKED)MID KSFE_NNUM-BRENC SD3IGIH. ALARMED EYERf 12 TO 15 MM (MANUFCNRFR'E NAME ASTM SPEC. D3953-91)• 1 1/4' WIDTM. GROUND ANCHORS DSHOULDFESSIO LCEFYflilm BY A PRDFESSIONIL ARCNIIECT. ENGINEER AND/OR NATIONALLY RECOGNRED O.C. TESTING LABOWTORY. THE MINIMUM WORKING 44�'-O" MAX SPACING LOAD CAPACITY SHOULD BE AT LEAST EMIAL 70 4725 LBS. ANCHORS SHOULD BE EMBEDDED BELOW THE FROST LINE AND AT LEAST 12' ABOVE 11 THE WATER TABLE 'PRIEM" - -MIL MINIMUM POLYETHYLENE FILM -JOINTS SHALL BE LIPPED 12-INCHES AND SEALED IMTH ADHESIVES Senyb Engineering Services _s_scenictlWyrste too- Lake Wales, FL 33853 THESE STANDARDS AND PLANS MEET THE 2010 F.B.C. - RESIDENTIALDESIGNED l - - - Vu =ULTIMATE DESIGN WIND SPEED =170 MPH (RISK CATERGORY II BUILDING) SE S__ DRAWING INFORMATION ru,ME, L_OT69_(12'�_X64'-0°� Address: 3318 Orange Park Ave., Ft. Pierce, FL 34947 FOUNDATION PLAN AND DETAILS FOR 20 PBFROOFLNELOAD AND 1000 PSF SOIL BEARING Phone: 863589-5980 VA =NOMINAL DESIGN WIND SPEED = 132 MPH (CATERGORY II BUILDING) (TABLE1609.3.1) M.B.J. PROVIDED BY CAPACITY DATE: 11-05-2013 Fax: 1.866-865-2044 LEONARD G. WOOD P.E. #47377 S]ENY I 318 S. SCENIC100 EONA G. WOOD ]EN G A N]E]EIMI h (G SEMB ENGINEERING SERVICES 1 SC NOTPRINTEDTOSCALE WALES FIiWY�TE EGI P S ONAL OFFICE:863589-5980 ENGINEER # 47377 I V � �]E]M IOE5 Lake Wales, FL 33853 SHEET 1 OF 1