Loading...
HomeMy WebLinkAboutLETTER-ENGINEEERINGL SCANNED BY �-- reasure Harvey E. Ko •� Koehnen C OaSt Professional. ,Engineer #32831 B° 011din Architect #AR0009471 9 _ E ngrneerS- Certified.General.Contractor #C6CO24776. Inc. April 13, 2016 Saint Lucie County Building Department Permit #1603-0544 Owner: Mr. and Mrs. Floyd APR 19 Address: 10701 S. OceanDr., Jensen Beach, FL. PcH:AiT"TItNG Contractor: Mel-Ry Construction- St. Lucie County, FL o Whom It,May Concern: letter and the revised plans submitted with them represent our corrections and/or responses to your review comments generated by your department. These corrections and/or responses, are as follows: 1. These three comments will be addressed by the relevant party and is not address in this letter jilPlans Examiner: 1. Contractor plans to remove and replace compromised soil with proper soil for a minimum soil bearing capacity of 2000 lbs/sq. ft. Any required certification to be supplied at appropriate time. Any required notice for permitting reasons will be supplied with this revision but supplied by others. 2. Corrected MAN "J" and Energy Calculations to be submitted with this revision done by others. 3. Zero lot line footer modification now correctly shown on sheets two (2), three (3), and six (6) of seven (7). 4. Required hydro vent now shown on sheets two (2) and three (3) of seven (7). 5. Clear net area of hydro vent now shown on elevation on sheet two (2) of seven (7). 6. Hydro vent now shown on elevation on sheet two (2) of seven (7). 7. Handwriting on truss layout has been removed 8. All references to carport have been removed 9. All overhangs on zero lot line side now shown and notes added that all overhangs in that area to be no more than 6" including fascia and gutters on sheets two (2) and six (6) of seven (7). 10. No showing on floor plan on sheet three (3) of Seven (7) method to comply with R302.1 11. No showing on floor plan on sheet three (3) of Seven (7) method to comply with R302.1 12. Opening now will be closed with traditional glass block to bottom of beam as labeled on sheets two (2) and three (3) of seven (7) -T;C B E, Inc,' ; 7205 Elyse. :Circle Phone :.;(772) 46675509 ' Fax (772) 489-3035 Port Saint Lucie ... Florida 34952=8212 E-mail hkoelinen@tcbewe6'.com Web site http:%%www.tcbeweb.com r 1. Corrected issue refer to number nine (#9) under plans examiner responses. W it believe with these revisions our plans will now be in compliance wth FBC 2014 5I' edition If ou have any questions, please call our office. RI spectfully Submitted, _ N, 3283E � P : "STATE isle 1110 H � r "ey lE. K ` ehnen, PE 32831 t C B- E, Inc. 7205 Elyse .Circle Phone . ..(772) 466-5509 Fax_ (772)489-3635 Port Sa3495 -8 1.' E=mail hkoe. en@tcbeweb.cofn Florida 34952-8212 Web site http:%%www.tcbew'eb.com