HomeMy WebLinkAboutSET-UP MANUALS . '-UP MANUAL, J..A 0 B S: N HOMES 600 PACKARD COURT SAFETY HARBOR, FLORIDA 34695 (727) 726-1138 NOTICE These specifications and drawing are original, proprietary, and confidential materials of Jacobsen Manufacturing, Inc. Such materials are provided to the recipient for specific purposes and must be kept confidential and secret from others. SU-00-0000 REV-01 /13 MANUFACTURED HOME SET-UP *SITE PREPARATION ' (A.) BLOCKING (B.) LEVELING (C.) ASSEMBLY AND CLOSE-UP *TIEDOWNS (SEE SET-UP MANUAL ADDENDUM) *ELECTRICAL CONNECTIONS *PLUMBING CONNECTIONS *A.C. CONNECTIONS *ON SITE VENT CONNECTIONS SITE PREPARATION *MISCELLANEOUS DETAILS IF YOU ARE GOING TO LIVE IN A PARK, YOUR HOME SITE WILL BE READY OR BE PREPARED FOR YOUR HOME. IF YOU INTEND TO INSTALL YOUR HOME ON YOUR OWN LOT (NOT IN A PARK), SOME SITE PREPARATION WILL BE NECESSARY. ALL DRAINAGE (AT THE INSTALLATION SITE) MUST BE DIVERTED AWAY FROM THE HOME AND MUST SLOPE A MINIMUM OF 1/2" PER FOOT AWAY FROM THE FOUNDATION OR SKIRTING FOR THE FIRST 10'. THE SITE MUST BE GRADED TO PROVIDE FOR STORM RUN-OFF. SPECIAL CARE MUST BE TAKEN WITH THE AREA DIRECTLY BELOW YOUR HOME TO PREVENT WATER FROM PONDING AND/OR PUDDLING UNDER YOUR HOME AND SUPPORTS. IF THE SPACE UNDER THE HOME IS TO BE ENCLOSED WITH SKIRTING OR OTHER MATERIALS, A VAPOR RETARDER (I.E. POLY...) MUST BE INSTALLED TO COVER THE GROUND UNDER THE HOME (SHALL BE 6 MIL. AND ALL SEAMS TO OVERLAP 12" MIN.) REPAIR ANY TEARS OR VOIDS IN THE RETARDER BY PATCHING WITH LIKE MATERIAL, MAINTAINING, A MINIMUM 12" OVERLAP AND SEALING JOINTS WITH DUCT TAPE OR MASTIC. I PIER SUPPORTS MUST BE PLACED ON UNDISTURBED SOIL (ALL GRASS AND ORGANIC MATERIAL MUST BE REMOVED) OR FILL WHICH IS COMPACTED OR FULLY SETTLED (SEE SU-4.1, DETAIL 'A' AND DETAIL 'B'). IN AREAS THAT' ARE SUSCEPTIBLE TO FROST, PIER SUPPORTS MUST BE BELOW THE FROST LINE. OPTIONAL: PIERS MAY BE PLACED ON CONCRETE RIBBONS 6" X 16" X LENGTH OF HOME MINUS 18", REINFORCED WITH WELDED WIRE MESH. (A.) BLOCKING UNLIKE A STANDARD HOUSE, YOUR MANUFACTURED HOUSE DOES NOT NEED A FOUNDATION TO SUPPORT IT COMPLETELY AROUND ITS PERIMETER. THE STEEL FRAME OR CHASSIS USED FOR TRANSPORTATION ALSO SUPPORTS THE HOME AT ITS HOME SITE. THE STEEL FRAME MUST BE SUPPORTED (SEE SU-01-0003 & 0004) TO PREVENT YOUR HOME FROM SAGGING, AND TO KEEP IT LEVEL. NOTE: ADDITIONAL PIERS ARE REQUIRED AT ALL RIDGE BEAM SUPPORT COLUMNS (EXCEPT AT THE FRAME HEADER), SHEARWALLS, AND AROUND THE PERIMETER OF YOUR HOME. CHECK FOR THE APPROPRIATE DETAILS FOUND IN THIS AND THE SET-UP MANUAL ADDENDUM FOR SPECIFICS FOR EACH TYPE OF ADDITIONAL BLOCKING REQUIRED. SPECIFIC BLOCKING LABELS ARE FOUND ON THE EXTERIOR SIDES OF YOUR HOME. MAXIMUM HEIGHT OF A PIER IS DETERMINED BY THE TYPE OF PIER USED, CHECK THE APPROPRIATE DETAILS FOR THE PROPER CONSTRUCTION OF EACH DIFFERENT TYPE OF PIER. (ALSO SEE TIE -DOWN REQUIREMENTS TO DETERMINE MAXIMUM HEIGHT FROM GROUND.) ALL SUPPORTING STRUCTURES NOT LISTED OR SHOWN IN THIS MANUAL OR SET-UP MANUAL ADDENDUM MUST BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER. (B.) LEVELING PROPER BLOCKING SEQUENCE IS ESSENTIAL IN THE LEVELING OF YOUR HOME. (SEE BLOCKING DETAILS ON SU-01-0002 ,0003, & 0004) FOR THE RECOMMENDED BLOCKING SEQUENCE, TAKING CARE TO CHECK YOUR LEVEL BETWEEN EACH STEP AND SUPPORT. RECOMMENDED LEVEL IS A 48" CARPENTER'S LEVEL. (SEE ACCEPTABLE LEVELING GUIDE BELOW) BUBBLE HAIRLNVES CARPENTER'S LEVEL 1/A IS MAXIMUM ACCEPTABLE SPECIAL NOTE FOR ALL HOMES SET IN FLORIDA CHECK FLORIDA STATUTE 15C FOR ANY UMITAIONS THAT MAY AFFECT THESE INSTRUCTIONS. ❑❑❑❑ JACOBSEN HOMES NOTICE: DRAWN BY: DATE REV. LETTER: THESE SPECIFICATIONS AND DRAWINGS ARE O.A. 11-21-06 bE]Et]E]El ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: D MATERIALS OF JACOBSEN MANUFACTURING u P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE MANUFACTURED HOME SET-UP SAFETYHONER(727) 726ID 1384695 � ENT ONFID AL MD � AND FROM O �R DRAWING NUMBER: SU-01-0001 (10-08-08) 1. MADI FRAIEE xA*8 UN t� NOTE Ili) In CAPPED WIN SOLID CiBIxm__� B• X r X le MLM YA901w am—,' i0l OPBI CMS VERTICAL SEE TABLE I FOR PER I= SM AND SPACIIM SPEfS1ClIlI0N5 (PAGE 11) (SEE SU-M FOR 16 X 16 PRECAST PIER PAD TAM) SE NO1E 11-- DETAILS "A" AND "B" lobI ft RFJM ALL ORGW YAMK--' AND RACE PAD ON SIAAN SOIL BELOW FRObT IOff PER LOCAL CODE ENIIIBffHiS. SEE NOTE 12 DETAIL 'A' psm vmEs To IWX. AILOWVIIE SOIL BfMXG) X-DOWR STRAPS ATTAM-\ TO mm ma COLUm ON UCH SECTION TO BE COIOffL:1ED TO A OWN HEADED ANCHOR. SEE NOTE DME HEADED F'i fo CAPPED wN SOLD 7. CONf7RM am (IBIL i 1t m f X 6' X 16. 6411l YASONR1f B. ROCKS mm OPBI REVS VERIIGIL (SEE NOTE 0 FOR YAX. PIER NETm AND DETAL ABOVE) 9. SEE TARE FOR PER FOOIER SRM AND SPA= SI'ECBi im 10. (PAGE 10) 11. WIDE ALL ORGANIC YATERUI. AIM Ra PAD ON STABLE ML BELOW FRMUE PER LOCAL. / 1. 000E IEgTHElENiS SET: MR 12-DETAIL 'B' \SEE NX R OE]ISIDiI VARES 10 INM ALLOWABE SOL ffANr rte6aQ„ _ E IV No 484 IkTE OF R O P•° N •...... __<<?.1.e JACOBSEN HOMES' m7mw v ate+ MAM►ACE m P.O. BOX 369 W. am MA1FJlAIS w Pd0m 10 w MWEI SAFETY HARBOR. FLORIDA W95 PHONE (727) 726-1138 NNW FM f= RIDES n w t err OMMM AI MW 0 2. 36- MAX. SINGLE STACKED FOR HOLLOW BLOCKS AT [-BEAMS. Se MAX. PIER BLOCK DRY STACKED AT PERIMETER* MATING UNE. (PIER SYSTEMS ANY TALLER MUST BE APPROVED BY A UCENSED ARCHITECT OR ENGINEER) MAXIMUM PIER/PAD PROJECTION: SEE OTHER DETAILS ALL PIERS MUST BE CENTERED ON FOOTERS MUST BE WITHIN .1 /Y OF PLUMB PER 3285 STANDARDS. MARRIAGE WALL OPENING PIERS TO BE WITHIN 6. OF OPENING ON OTHER SIDE OF COLUMN. (WHEN REQUIRED FOOTER SIZE PREVENTS A SINGLE STACKED PIER FROM MEETING THIS, USE A DOUBLE STACKED PIER. GOOD UP TO 28 X 28 FOOTM) MINIMUM PIER PAD THICKNESS: A. 4- MIN. FOR PRECAST UNITS UP TO 16- X 160 B. FOR CAST IN PLACE FOOTINGS ON 2000 PSF SOIL (MAX.) THE IN. THICKNESS IS MAX. F007ING DIMENSION DIVIDED BY 4.(BUT NOT'LESS THAN 6-) ALL FOOTING CONCRETE TO HAVE COMPRESSIVE STRENGTH. (fel m 3000 PSI (MIN.) PLACE 6 MIL POLY ON GROUND PRIOR TO POURING FOOTING . CONCRETE (ALL SEAMS TO OVERLAP 12 MIN.) PIERS SUPPOR71NG THE I -BEAMS TO. BE WITHIN 24. OF BOTH ENDS AND NO MORE THAN 1 W O.C. PIERS MAY BE OFFSET UP TO 60 IN EITHER DIRECTION ALONG THE I -BEAMS TO ALLOW FOR PLUMBING, ELECTRICAL. ETC. FOOTING CONSTRUCTION MUST COMPLY WITH LOCAL BUILDING CODES. WOOD SHIMS, WHEN REQUIRED ARE TO BE USED IN PAIRS INSTALLED IN OPPOSITE DIRECTIONS AND FITTED TIGHT BETWEEN THE I -BEAM AND PIER CAP. SHIMS MUST BE MIN. C LONG BY 6- WIDE AND NO MORE THAN 1- IN THICKNESS. APPROVED BY Revised IN Dec 17,2008 INK. FEDERAL MARUFACIURED HOME CONSTRUCTION AND SAFETY STANDARDS O.A. 09-07-93 .DETAILS -A- & SU-01-0001.1 (12-15-08) MOBILE HOME SET-UP NOTES: 1. JACKS TO BE RATED AT 5 TONS. 2. ALWAYS USE A SUPPORT UNDER JACKS. 3. FOLLOW BLOCKING INSTRUCTIONS. 4. FOR MULTIPLE WIDES SET HEAVY SECTION FIRST. BLOCKING SEQUENCE 1. LOCATE HOME ON SITE AND LEVEL AS CLOSE AS POSSIBLE USING HITCH JACK. 2. SET SUPPORTS (BLOCKS #1) UNDER BOTH I -BEAMS JUST FORWARD OF THE FRONT SPRING HANGERS. 3. SET SUPPORTS (BLOCKS #2) UNDER BOTH I -BEAMS JUST BEHIND THE REAR SPRING HANGERS. 4. LOCATE SUPPORTS (BLOCKS #3) MAXIMUM 24" BEHIND THE FRONT CROSSMEMBER. 5. LOCATE SUPPORTS (BLOCKS #4) MAXIMUM 24" FROM THE END OF THE HOME. 6. ADDITIONAL SUPPORTS (BLOCKS #5) MAY BE NECESSARY BETWEEN 1 & 3 AND 2 & 4, IF THEY ARE NEEDED THEY SHOULD BE SPACED EQUALLY, MAXIMUM SPACING 10'-0". 7. IF YOUR HOME HAS 4 AXLES ADD BLOCKING BETWEEN THE MIDDLE SET OF AXLES. 8. FOR SINGLE WIDES BLOCKING IS COMPLETE. 9. FOR MULTIPLE WIDES REMOVE ALL SHIPPING BATTENS AND VISQUEEN AND SET LIGHT SECTION(S) AS CLOSE AS POSSIBLE TO THE ALREADY SET HEAVY SECTION. 10. JACK THE LIGHT SECTION(S) TO THE HEAVY SECTION USING JACKS AND COME-ALONGS. 11. FOLLOW BLOCKING SEQUENCES 1 THRU 7. NOTES: 1. THESE FOUNDATION SPECIFICATIONS HAVE NOT BEEN DESIGNED FOR FLOOD -RESISTANT SPECIFICATIONS. 2. PERIODIC RELEVELING MAY BE NECESSARY BECAUSE OF THE WEIGHT OF THE HOME AND SETTLING THAT MAY OCCUR. ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: O.A. DAIS 06-06-94 REV. LETTER: ❑❑.❑ ORIGINAL, PROPRIETARY. AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: MOBILE HOME SET-UP n ❑,�❑ P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE f2 ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-01-0002 (09-30-08) 3 SEE NOTE #7/ SEE NOTE #6 4 2 1 5 5 3 -SEE NOTE #2 NOTE #1 I NOTE #5 SEE -NOTE #3 TYPICAL SINGLE WIDE BLOCKING (SEE SU-01-0004 FOR NOTES) SEE NOTE #7/ SEE NOTE #6 4 2 1 5 5 3 I SEE NOTE #2 ,.-SEE NOTE #4 ---� -,.--SEE' I NOTE #1 \-NOTE #5 SEE NOTE #3 TYPICAL DOUBLE WIDE BLOCKING (SEE SU-01-0004 FOR NOTES) NOTICE: DRAWN BY: S.A. DATE. 6-6-94 JAC O B S E N HOMES THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: P.O. BOX 368 MATERIALS OF JACOBSEN.MANUFACTURING DOUBLE WIDE BLOCKING INC. SUCH MATERIALS ARE PROVIDED TO THE SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: APHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-01-0003 4 SEE NOTE #7 SEE NOTE #6 2 1 3 I NOTE #5 > SEE NOTE 3 >_ SEE NOTE #2 I �- SEE NOTE #4 I NOTE #5 NOTE #1 I I SEE NOTE 3 ..l 4 2 1 NOTEE E #6 5 5 3 TYPICAL TRIPLE WIDE BLOCKING SEE NOTE #7 NOTES #1-MAIN FRAME I -BEAMS #2-LOCATE PIERS UNDER FRAME I -BEAMS #3-LOCATE PIERS UNDER CLOSEST FLOOR JOIST EACH SIDE OF OPENINGS 48" AND LARGER. (I.E.-RECESSED ENTRIES AND SL. GL. DRS.) SEE TABLE FOR PIER FOOTER SIZING PAGE 10. #4-LOCATE PIERS UNDER MARRIAGE WALL PERIMETER JOISTS WITHIN 6" OF EACH SIDE OF OPENINGS. 48" & LARGER AND RIDGE BEAM COLUMNS. SEE TABLE FOR PIER FOOTER SIZING SU-01-0030 AND SEE DETAIL 'B', SU-01-0010. #5-AXLE ASSEMBLY CENTER LINE #6-SEE TABLE I FOR PIER FOOTER SIZING AND. PIER SPACING INFORMATION SU-01-0040, AND DETAIL 'A' SU-01-0010. #7 OCKING SEQUENCE NUMBERS, SEE SU-01-0002 FOR PROPER BLOCKING PROCEDURES. ❑❑❑❑ ❑❑■❑ ❑„❑ ❑❑❑❑ JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: DRAWING 717LE: TRIPLE WIDE BLOCKING DRAWING NUMBER: SU-0I-0004 5 ADDITIONAL PERIMETER BLOCKING (THIS BLOCKING IS IN ADDITION TO BLOCKING REQUIRED IN THIS MANUAL) BBBBBBBBB■-� TYP. FIREPLACES ON SIDEWALL OR MARRIAGE WALL HOST 6SAN NOT p ETER BLOCKING REQUIRED AT 48' O.C. MAX 54' OR 60' TUB AT SIDEWALL OR MARRIAGE WALL UNDER EACH SIDE OF ALL EXTERIOR DOORS LOCATED ON SIDEWALLS 2 OR MORE 461/2' WINDOWS PIERS REQUIRED AT EACH END AND BETWEEN EACH OPENING r RECESSED AREAS REQUIRE PIERS SPACED 64' O.C. MAX (18' OR LESS IN DEPTH) EACH END OF RECESSED AREAS RECESSED AREAS W/SIDE BAY REQUIRE PIERS SPACED 64' O.C. MAX THIS ALSO APPLIES TO ALL ENOWALL BAY WINDOWS UNLESS SUPPORTED BY A FRAME MEMBER GARDEN TUB AT SIDEWALL OR MARRIAGE WALL . 64' O.C. MAX . ME L:7�in REFER CABINETS ALONG SIDEWALL OR MARRIAGE WALL (APPLIES TO BATH CABINETS 80' OR GREATER IN LENGTH) (SAME BLOCKING MAY BE USED FOR MULTIPLE 461/2' WINDOWS) SPECIAL BLOCKING NOTE FOR 15'-4" (184") WIDE FLOOR SECTIONS PERIMETER BLOCKING IS REQUIRED (MARRIAGE AND SIDEWALLS) 64' ON CENTER MAX SPACING NOTE LEVEL FLOOR SYSTEM FIRST (SIDEWALL TO SIDEWALL OR MARRIAGE WALL) BEFORE INSTALLING PERIMETER BLOCKS NOTES: 1. ADDITIONAL BLOCKING REQUIRED AS INDICATED ABOVE (USE 16' X 16' PIER PADS). 2. LOCATE BLOCKING UNDER PERIMETER JOIST OR WITHIN 8' OF END OF 16' O.C. JOISTS 3. COLUMN PIERS ARE IN ADDITION TO REQUIRED PIERS UNDER FULL -HEIGHT MATING WAILS. 4. PERIMETER BLOCKING IS REQUIRED UNDER TILE FLOORS (MARRIAGE & SIDEWALLS) 64' O.C. MAX. 5. PIERS USED FOR PERIMETER SUPPORT MUST BE INSTALLED 1ITH THE LONG DIMENSION PARALLEL TO THE PERIMETER RAIL 6. WHEN PERIMETER BLOCKING IS REQUIRED ANY MATING LINE OPEN SPAN GREATER THAN 10', MUST HAVE INTERMEDIATE PIERS PLACED AT MAX 10' O.C. EXCEPT 154 TIDE, SEE SPECIAL NOTE ❑❑❑❑ JACOBSEN HOMES NOS 3PECR1CAT DRAWN BY: O.A. DA1E 4-12-00 REV. LETTER: ❑❑�❑ wHS RMCEk A!B) URAMRIGS ARE 0Rm+"4 PROPFETMY• AND MMMIAL MATERUUS OF JACOBSEN MANUFACRMG DRAWING TITTF ADDITIONAL BLOCKING ^ P.O. BOX 368 DIC. SUCH MATSMS AKA: PROVW TO THE ❑ SAFETY HARBOR, FLORIDA 34695 REwff FOR ffm ROM AND MAT BE DRAWING NUMBER: PHONE (813) 726-1138 KEPT CONFDENRAL AM SEC U FM O4FRs SU—O)-0005 (09-3Q-OB) 6, (APPLICABLE TO ALL IMPERIAL A41) gdOR0 COTTAGES WTH 184, FLOOR OPTHS-SEE FL-01-0009.2) ON SITE PERIMETER BLOCKING O.C. SPACING 16 X 16 PIER PAD 17 X 25 PIER PAD MIN. 1000 PSF SOIL 1500 PSF SOIL 1000 PSF SOIL SIDEWALLSMATELINE MALL 49"" 4" 64"/40" 64"/49" VAX LOAD INCLUDING PIER AND FOOTER 1778# 2667# 1 2950# REP. ®0 0°. 0000e°no 6� o ;y E I S,. ®moo No 454 a� rem 4 d. m ® m ST E OF �®" ° ALL JONDZ01ES ALL EXPOSURES 20 PSF ROOF 10 PSF D.L. C-FL- 89.01 - 89.03 APPROVED BY May 07,2009 INC. FEDERAL WINUFACf11RED HOrE CONSTRUCTION AND SAFETY STANDARDS NOT4d4 REV, LEM. JACOB9EN HOME sa�arls:�nogs �� ,� oR � M.T. DAiE. 03-02-09 r A�, Non AK pRA NG n1L6 P,o. Box 36e H imait '.o y4 �o�Tjo0 ADD. PER. BLOCKING REQUIREVE4TS SAFETY HAR80R, FLORIDA 34695 RIOR r rm ,��c vUrP•DYS AIQ IA1 K DR C U M PHONE (727) 726-113. II t n►L up sc�c� rabM onEas SU-01-0005.1 BLOCKING (PIER) LABELS LOCATE THESE LABELS AND CHECK THE APPROPRIATE MANUAL FOR PROPER INSTALLATION OF BLOCKING AND PIERS.. SHEARWALL PIER LOCATIONS SEE SET-UP ADDENDUM FOR SPECIFICS COLUMN PIER LOCATION SEE SET-UP MANUAL FOR SPECIFICS (LOCATE THESE PIERS AT hh, THE MARRIAGE LINE) A BOTTOM OF EXTERIOR SIDING AT SIDEWALL . ISPECIFIC PERIMETER PIER LOCATION SEE SET-UP MANUAL FOR SPECIFICS , BOTTOM OF EXTERIOR SIDING AT SIDEWALL 1. THIS IS INCLUDED IN THE HOME OWNERS PACKAGE. NOW& MAN BY: DAZE REV. LETTER JACOBSEN HOMES 7HESE 7MAND DRAWMSAM M.T. 05-20-06 O TART AND UMULNWL DRAWING TI1LE: B AZE MS OF JACOBSEN YANIFAM11 MP BLOCKING (PIER) LABELS P.O.P.o. BOX 388 W. SUCH MA70M ARE PROVED TO 7W SAFETY HARBOR, FLORIDA 3095 wam FUR 9D PURPOSES AND my 6E DRAWING NUMBER: (09-04-12) PHONE (727) 726-11M REPT CCPEDO m AN Swu FROM ORERS SU-01-0006 N. ADDITIONAL RECESSED PORCH BLOCKING (Teats BLMM is w ADDRIDr1 To B cic REOIARED N THIS Oak) `7 I � � r• i it •�•,r •� memo OF, ���� • awn WALL EXUOB 114L Am l-BEAU LENDER EXTERIOR TFALI. PER Ufa Altt}m � Y �RECESBICN REOI tE PMSPACED 64• QG' YAX pig LED Ap yr� %xw PIERS AT PORCH POSTS) AS SHOWN 640 o.Q MAX PIER SPACING AT UARWAGRALL Not IBM BMW EOGE OF PIER AND EDGE OF PORCH POST YAr NOT WO DEPTH. OF V. PORCH POST TIP. PORCH POST FLOOR JIM (S Itt) K E M• uJiY_ TYP PORCH FLOORING T1fP. PORCH FLMG PORCH FLOOR JOIST DOUBLE PM METER R4 (2) 2X 6 PT x Ur UK Kn E!! 2 rl TiP. 1E-" STRAPno (SEE OiF1TR OETAllS)PORCH FLOOR JOISTS IER(6'XrX1b') 16' X 16' YIN. PNR PAD BOSS SECTION VIEW Al TIP. PORCH POST TIP. PORCH FLOONG PORCH FLOOR JOIST (2)2X6PT IIf WL BWO BETTiEM 2 PORCH FLOOR. JOISTS LONGITUDINAL VIEW A2 DETAIL 'A' PORCH an jw DOUBLE PORCH PEIXTER RAIL (2) 2 16 PT X 1B' 1LN lXtDLID BETWEEJF 2- TIP. XE-D0111 STRAP PORICH ELM AM (SEE 011QR DETAILS) TIP. PIER (e X S X 167 IC X 16• UK PIER PAD CROSS SECTION VIEW Bl IV. PORCH POST • HOTE: DISTANCE SElYkW �PNR EDGE OF re. PORCH FLOOIipLG��Ti2 a1 AND EDGE OF PORCH POST PORCH FLOOR JOIST YAY NOT E1®51/2' (28))22 XB6 PT XmI 2YN.� TYP. X-DOYr! STRAP (SEE OWDETALS) PORCH FLOOR JIMS LONGITUDINAL. VIEW B2 NDTES: L AOOIMI& BLOCION6 REOI= AS INDMIED ABOVE (USE iC X iC PIER � : + 0. 0 4a 3 ��, • PADS OE iom PSF SOL MACITO . 2. LOCALE EttWW HIDER PEIaUW JOIST OR 311M S 1/Y OF END OF IC QC. a pffa iFB @LDGm a REWttED UNOER PORCH AT EACH POST (6P Ot VAX) 4. ADOIiRM BLOCUS RE*= AS INVA1ED ADM UIOER CENTER OF AM D FM � ;,, rd t i SEE OMM OETAAS FOR 011 M REGM BLOOM EO ANG 6 AIM F-BEAY AT PORCH/E><iE" WALL WY WM a 92E FROM !WN HOUSE 4-BEA1r , fir` S'j`C,`"�' L,=;`C'1'►�y�. JACOBSEN HOMES 1= »t" AM DRAW= AK gocK% tFAfll[Tm%"Qo1+ mik ORAIM UXL- UA=KS of ,UICMWG M NIIFAOTUA 0 PA; BOX 368 W- SM MAMAS ARE MWOM TO X SAFETY HARBOR. FLORIDA 34695 tE'MW fat 9BnC NCH' O" WO IE P RAWINO NUMBER PHONE (el�) 726-1138 ta7E CDf1oF81ut Aw ifpl[i Eltw oao�i 9 APPROVED BY "INPIDec 13,2006 INC. FEOEML MNiUFOCfU1E0 MOUE QONSiR11Cf10N MD SAFELY RAKDAR0S 11-28-06 SU-01-0007 ATTACHMENT TO HOST BEAM ATTACHME14T MAY BE FLUSH WITH HOUSE —� HOST BEAM STRUCTURE ATTACHMENT SECURED DIRECTLY TO FACTORY INSTALLED HOST BEAM (THIS IS IN LIEU OF 'FOURTH WALL CONSTRUCTION') STRUCTURE ATTACHMENT INSTALLED ON -SITE BY OTHERS -AND MUST MEET LOCAL CODES PERIMETER BLOCKING ON -SITE. 480 O.C. MAX. DESIGN MEETS FBC AND A.SCE FOR 140MPH (3 SEC. GUSTS)ALSO MEETS WINOZONE. III EXP. B LOADING FOR PARTIALLY ENCLOSED STRUCTURES- REF. PG. 07-0050, 07-0051 20 OS ROOF N.DS01 �2 111.9 TES: ��'; "N HOST BEAN INSTALLA71ON IS FOR ON SITE STRUCTURE ATTACHAIENI: 20' ODE MAX WIND ZONE 2 OR 12.7MPH EXP. B SITES, 16' WIDE MAX MNO ZONE 3 OR 14OMPH EXP. B SITES MIN. BRACKET LOAD CAPACITY FOR VERTICAL TIE -DOWNS IS 24501 WIND ZONE Z 29601 WIND ZONE 3 4 WALL FRAMING IS 2 X 6 SPF /3 IV O.C. ;. ¢ STf.Yr_ OF 48'. O.C. PEIMETER.BLOCKING REOLIRED ON HOST BEAM SIDE OF HOUSEc;OP..�a4: ' JACOBSEN HOMES T sKum' ma t< DNIWIAL PIMPKTANY. AND OOJF10E11T41 AYANG non HP Sox s6lf MA10MU Or' � NM SIM MAWOU AFE aawooD w THE SAFETY HARBOR.. FLORIDA 34695 Kcmf RR >lErnc ramos>:s Alo NO A[ DRAW PHONE (727) 726-1138 . art cmmm i. wr wav mom onoa . 10 10 PSF D.L. OAPIA APPROVAL: APPROVED BY �i ON Jan 20,200 P r� INC. FEDERAL NANIFACf1IRE0 NOtlE CONSTRUCTION AND SAFETY STANDARDS D.M.T. 01-10-07 ATT. TO HOST BEAM SU-01-0008 BLOCKING FOR TEMPORARY SET SINGLE WIDE UNIT .MAIN I -BEAM FLOOR SYSTEM MUST BE LEVEL HEADER AXLE � MAIN I -BEAM I I BLOCKING PIER BLOCKING PIER BLOCKING PIER MAIN [-BEAM _ HITCH TEMPORARY BLOCKING IS REQUIRED ON HOMES LOCATED AT THE DEALERS LOT OR PARKED AT HOME SITE FOR ANY PERIOD OF TIME. BLOCKING PIERS ARE TO BE LOCATED UNDER MAIN I -BEAM AT THE REAR, AT THE HITCH, IN BACK OF AND IN THE FRONT OF AXLE AREA. MULTI —WIDE UNITS BLOCK EACH UNIT OF MULTI -WIDE HOME IN SAME MANNER MAIN I -BEAM -7 HEADER 1 AXLE MAIN I -BEAM BLOCKING PIER BLOCKING PIER MAIN I -BEAM - - - - MATE LINE - - - AXLE MAIN I -BEAM BLOCKING PIER BLOCKING PIER MAIN I -BEAM FLOOR SYSTEM MUST BE LEVEL MAIN I -BEAM HEADER TEMPORARY BLOCKING IS REQUIRED ON HOMES LOCATED AT THE DEALERS LOT OR PARKED AT HOME SITE FOR ANY PERIOD OF TIME. BLOCKING PIERS ARE TO BE LOCATED UNDER MAIN [-BEAM AT THE REAR, AT THE HITCH, IN BACK OF AND IN THE FRONT OF AXLE AREA. 15'-4" (184") WIDTH UNIT REQUIRES PERIMETER BLOCKING 96" O.0 AT SIDEWALL AND MARRIAGE WALL. HITCH HITCH ❑❑❑❑ JACOBSEN HOMES r10TTcND 1HESE SPEgFlCAT1ONS AND DRAYANGS ARE URA11R Ol: D.M.T. UAIL" 1O-1O—OS R[Y. LCIIG ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFlDENTIAL DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC SUCH MATERALS ARE PROVIDED TO THE TEMP. BLOCKING ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECPENT FOR SPEM PURPOSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 KEPT OONRDFT & AND SEOU FROM OTHERS SU-01-0009 11 16" X 16" PIER FOOTER SPACINGS* MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" VADE FLOOR 39" 62" 86" 110" 134" 1571- 144" VMDE FLOOR 33" 53" 73" 93" 113" 1331 160" WIDE FLOOR 30" 48" 66" 85" 103" 121"' 184" WIDE FLOOR 26" 42" 58" 74" 90" 107" 11 MIN. PIER CAPACITY 1778 LBS. 2667 LBS. 3556 LBS. 4444 LBS. 5333 LBS. 6222 LBS. NOTE: ALL UNIT WIDTHS INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. 4" MINIMUM, AND/OR PER LOCAL CODE REQUIREMENTS 4" TYP � � 7" OR ' 8" 30' MAX Tw 'T . (TYP) X X a Q NOMINAL 16" X 16" SQUARE PRECAST CONCRETE FOOTING 00 col 16" MIN. EACH SIDE 4 X B X 8 SOLID 6 X 7 X 8 SOLID FOOTING CONC. BLOCKS CONC. BLOCKS TYPICAL PIER FOOTER TYPICAL PIER CONFIGURATIONS (THE CAPACITY OF THESE PIERS EXCEEDS MIN. REQUIRED) CONCRETE -NOTES WINDZONE III 1. ALL FOOTINGS CONCRETE TO HAVE is = 3000 PSI MIN AT 28 DAYS: (110 MPH) 2. ALL SOLID CONCRETE BLOCKS TO HAVE 1m' = 1500 PSI MIN; ALL EXPOSURES 3. CENTER ALL PIERS ON FOOTINGS 20 PSF ROOF 10 PSF D.L. REF. CALCS. C W A- - ?/:r� 671 0'2 `��aTunFFrugr� NOTES: EN V i � DAPIA APPROVAL 1. REFER TO OTHER DETAILS FOR ADDITIONAL PIER FOOTER SIZES AND • (�P.• GXST E ! RFo ••.• � Q (vp, APPROVED EY SPACINGS. 910334 2. START I -BEAM PIER SPACING 1/2 THE ALLOWABLE SPACING FROM EACH END OF THE HOME AT EACH I -BEAM. AND MAXIMUM SPACING SHOWN IN THE CHART IN ABOVE FOR FULL LENGTH OF HOME. �O STATE OF I INC3. SEE OTHER DETAILS FOR PIER REQUIREMENTS AND MAXIMUM OPENINGS �Q•�•.•/N A '�� FEDERAL MANUFACTURED AT MATING LINE OF MULTIPLE WIDE HOMES. .P'•��` �s s • •• CONSTRUCTI SA fT% fflAROS 4. SEE OTHER DETAILS FOR TIE -DOWN REQUIREMENTS. ?Ijor� M 1 l�y�' JACOBSEN. HOMES N IC THEsz sPEa�cAnaxs AN DFMwN ARE AWN BY: M.T. GATE 2-8-99 REV. LETTER DRAWING TITLE: 16" x 16" PIER SPACING ■ P.O. BOX 368 ORIaNAL. PROPRIETARY, AND COMFM IAL MATERIALS OF JACWSEN MANUFACTURINC SUCH MAmaALS ARE PRONDED TO THE SAFETY HARBOR. FLORIDA 34695 DIG. RECRENT FOR SPECM PURPOSES AHD MUST BE DRAWING NUMBER PHONE (727) 726-1138 KEPT CONnoo ML AND SE00 FROM OTHERS. SU-01-0020 13 Vb (eo-eo-op I lzoo-lo-ns 8 S831d �Y38 NlYA 11V �3uu :131 A38 66-$-z 131 a ��� 118 SaMINV1S.WNS ONV NOU- MN03 MON 03tl01')V3nNVN 1VU3033 -3N�LN d 800L'LT ��0 po®ineg AB a3AOHddtl 110' ASd 01 AN Ad OZ S381160dx3 (Hdn 0111 If 3 040 taa Bf11-99L (M) 3110Hd 969►F Yax1a11 d aoAl 1t B9f X08 V sin 03110H M3iS$r up 1 110 ANM MH of 38 AVA UM 3LMdp M 1Yt h Q4 t aD Z W Wl 1 Iffm a Oh S31Y W MWWH '9 YSM AM HMI No 58.31d 3% SY xla# ft Kiftl"39 lSnA SdV3 V 133LWO aD 73'd Y AB a3fM= 391S11A L9 3110BM S1HM Wad * 't �pgr `r1 otry "-I x3y3 l Ox 3x1 JD dg ►oM3".0Z d OYCIS IBM AV33-I 18M,S 1' %Wydy3 Od *0 TfM3 W a337X3 01 a#91m a a31sn 3B 1snA A3H1 Sand Mw AV 434 T uvydy0 lod i(A 4 TfM3 3B 1A amp 01 moulm dw amil 381 AN 313x>H00 hM 040 59Yd M „9I x .91 D* 04 'Sayd Bald ,91 x .91 WO 43HO *MdS MW a» i* OM-10-ns 'I (j5d 04MY38 'M �P a3SY8 Sat OV03 aY01 0Yd a 31d )WO) Wm fill 'jNrl"A S306.H108 Na `JtrYHa3AO .9 Y 53IMON smu$ iiNn 1310N WlVVM SI 1H'MA a31d IY314 33k3a3ilia OOV - 100 01 do a3ld i0 1HDL* 30 I*l SaYO1 831d '881 1069 - - -- %M 9199 'S81 98Zr 'S81 196Z M1! 3a* .091 S81 1619 '9A1 vlo9 W sm Val 199Z SOVU 3T .091 'Sol 9099 W gets 'S81 O&C SOO-U 3GI* j*1 '0'0 4M '0'0 „96 '0'0 ,.ZL '0'0 net 'Xdw H100 U001i (S31LOVdYO W1 ad A9 03110a11103) DNIDVdS 63id d38-1 MnMixvM (d V 0 3104 33) Al0rdY3 W 000-91 Slid 4010 M9V1S 31000 All 0=3104 i ad 3x1 Aq Aming 3x1 al dDl 3x1 Ill SIMM 7flWW *6 3dr S01313104M #O11ox A 1.0 x J 1rAIM S7m 4301Bo SMOM A Slim .91 x ;R x .9 Of 14 31) MW QYP1 3md x 80')M .0 3L31fJ1�00 x11� MMM 831d m!q a�I m S31d Moole VV1S 319 .IS Tmak S7m W Hl4 SIDDID WMA Qi m .91 x p x (9r 30 33S) 630AM GIVE x *a .r "al � l � A �1108 � � low IM 19 335)r x � Q 9 10018 moo Morm pi x ..9 x .® � `Z Q .Q � +x►!Ot(I►�l 3B AYO3� 16 000�� csx701H 31 ►d0 �x A X .0 x.P) R1111d fivag Nlyy.q,MY 3,L'Id otlllago #BOSB ,o :d-a .3.Lt113 . . o ,�. oi0% a ao .. BB®d8d®@O®B89®®® MINIMUM HOME SET HEIGHT FINISH GRADE NOTES: WHERE THE GRADE IS SLOPED, 25% OF THE LOWEST MEMBER OF THE MAIN FRAME MAY BE SET BELOW 18"; HOWEVER, UNDER NO CIRCUMSTANCES MAY THE BOTTOM OF THE I -BEAM BE SET BELOW 12" FROM THE FINISHED GRADE. NOTICE: DRAWN BY: B.E.M. I DATE: 2-11-99 REV. LETTER: ❑❑❑❑ JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWINGS ARE ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: MIN. HOME SET HEIGHT ❑ „❑ P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-01 -0022 04 15 i 16" X 16" PIER FOOTER SPACINGS* MIN. 256 SQ.IN) MAXIMUM I -BEAM PIER . SPAC.ING . FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500. (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) i120 WIDE FLOOR-- 39" 62.1/2". 86 1/2 110" SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR••. 33" 53" 73 1/2" 93 1/2" 113 1/2" SEE NOTE (/4 I160" WIDE FLOOR-- 30" 48 1/2" 66 1/2". 85". 103" SEE NOTE #4. 184" WIDE FLOOR** 26 1/2" 42 1/2" 58 1/2" 74 1/2" 90 1/2" 107" 'iIN. PIER CAPACITY 1778 LEIS 2667.LEIS �556 LBS 4444 LBS 5333 LEIS 6222 LEIS 18 1/2" X 18 1/2" PIER FOOTER SPACINGS* MIN. 342 1 4 SO IN), II MAXIMUM I BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL .BEARIN.G CAPACITY) �I WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 20" WIDE FLOOR-- 54 1/2" 86" 117 1/2" SEE NOTE #4 SEE NOTE S4 SEE NOTE j/4 44 WIDE FLOORoo 46" 73" 100" SEE.NOTE y4 SEE NOTE #4 SEE NOTE q4 I60" WIDE FLOOR•• 42" 66 1/2" 90 1/2 115" SEE NOTE #4 SEE NOTE #4 i 184" WIDE FLOOR** 37" 58 1/2" ;79: 1/2" 101" SEE NOTE y4 SEE NOTE g4 IN. PIER CAPACITY 2377 LBS. 3565 LBS. 4753 LBS.. .5942 LBS. 7130 LBS. 8319 LBS. NOTE: UNIT WIDTHS WITH •• INCLUDES A 6" OVERHANG ON. BOTH SIDES MAXIMUM. FOR TYPICAL PIERS 'SEE. PAGE SU-01-0021 I OTES: PRE —FABRICATED PIER PADS MAY BE USED AS AN ALTERNATE TO THE CONCRETE ENGINEER APPROVAL: e �� DAPIA APPROVAL: SEE CIfICS, 1. FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET—UP MANUAL. :" `` ' rY- t'F• al 2. THE PRE—FABRICATEO PIER PADS ARE TO BE INSTALLED PER THE � APPROVED BY MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM �(� ►+' 3. PIER CAPACITIES SHOWN ABODE. ALL OTHER REWIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN HOMES INSTALLATION INSTRUCTIONS, . 'y� '. ��A9 E.,�;ONTP ztr.• OCT 1 Y 4. MAX. PIER SPACING 8' FOR UNITS WITH B" I -BEAMS / 10' FOR UNITS WITH 10" OR ;� "" INC. 12" I f —BEAMS (24" MAX. FROM ENDS). FEDERAL MANUFACTURED HOAtE MNSTRI T AND SAFETY STANDARDS II O0 JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY. D.M.T. DATE: 09-22.01 REV. LETTER: P.O. BOX 368 , ORIGINAL PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE DRAWING. TITLE: PRE—FAB. 16" $ 18 12" ER PI P AD SPACING III SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 RECIRENT FOR SPECiIC PURPOSES"MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS -- DRAWING NUMBER: 1 SU-01-0023 i 18" X 22" PIER FOOTER SPACINGS* MIN. 396 SQ.IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WI D TH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 35d,0 (PSF) 120" WIDE FLOOR+• 63 1/2" 100 1/2" SEE NOTE y4 SEE NOTE y4 SEE.NOTE #4 SEEI NOTE #4 144" WIDE FLOOR•• 54" 85" 116 1/2" SEE NOTE p4 SEE NOTE y4 SEE, NOTE y4 160" WIDE FLOOR** 49" 77 1/2" 105 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 184" WIDE FLOOR** 1 43" 168" 93" 117 1/2" SEE NOTE N4 SEE'NOTE #4 MIN. PIER CAPACITY 2747 LBS 4121 LBS 5495 LBS 6868 LBS 8242 LBS 9616 LBS 20" X 20" PIER FOOTER SPACINGS* ( MIN. 400 SQ. IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) i WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR- 64 1/2" 101 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR** 54 1/2" 86" 117 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 160" WIDE FLOOR** 49 1/2" 78 1/2" 107" SEE NOTE a4 SEE NOTE #4 SEE NOTE #4 184" WIDE FLOOR** 43 1/2" 69' 94" 119" SEE NOTE N4 SEE NOTE #4 MIN. PIER CAPACITY 2778 LBS. 4167 LBS. 5556 LBS. 6944 LBS. 8333 LBS. 9722 LBS. NOTE: UNIT WIDTHS WITH ** INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 NOTES: EN PRC I�Q� *ryy �,�� Q� .•.,...... �%Fjtr ry+i� DAPIA APPROVAL' 1 /SEE 1. PRE -FABRICATED PIER PADS MAY BE USED AS AN ALTERNATE TO THE CONCRETE HOMES SET-UP MANUAL. �� es- ,•G%gTE•? ' �'�� / C� r Y - (¢ • a� FOOTINGS SPECIFIED IN THE JACOBSEN iq0 d 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE i •.�4, 9103 "r %z APPROVED BY. MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM CAPACITIES SHOWN ABOVE. PIER 3. ALL OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN K �some_�- HOMES INSTALLATION INSTRUCTIONS. •,. 4' o� ' �bj iNC. 4. MAX. PIER SPACING 8' FOR UNITS WITH B" I -BEAMS / 10' FOR UNITS WITH 10' OR ., .• 12" I -BEAMS (24' MAX. FROM ENDS). • EDERALMANUFACTURED HONIE c ...in0 'DATE: JACOBSEN HOMES NOTICE: F OW1 THESE SPEC6ICATIONS AND DRAWINGS ARE � BY: D.M.T. 09-22-01 REV. LETTER: DRAWING TITLE: PRE—FAB. 18" X 22" do 20" PIER PAD SPACING P.O. BOX 368 ORIGINAL. PROPRIETARY. AND CONFIDENTIAL MATERIALS OF KCOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROWDED TO THE — DRAWING NUMBER: SU-Ol-OO24 „ SAFETY HARBOR. FLORIDA 34695 PHONE (813) 726-1138 RECPIENF FOR SPECRIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS W I 17 3/16" X 25 3/16" PIER FO.OTER SPACINGS* (MIN. 432 7 8 SQ.IN) r MAXIMUM I -BEAM PIER SPACING Ii FLOOR MAXIMUM PIER SPACING (SOIL BEARING `CAPACITY) 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 :(PSF) 3000 (PSF) 3500 (PSF) WIDTH 12 1, WIDE FLOOR-- 70 1/2" 110 1/2. SEE NOTE #4 SEE NOTE #4 SEE NOTEJ4 SEE NOTE #4 1411 WIDE FLOOR** 59 1/2" 93.1/2" SEE NOTE #4 SEE NOTE.y4 SEE NOTE p4 SEE NOTE #4 16$' WIDE FLOOR-- 54" 85" 116" SEE NOTE #4 SEE NOTE y4 SEE NOTE #4 18 i� WIDE FLOOR-- 47 1/2" 75" 102" SEE NOTE #4 . SEE NOTE y4 SEE NOTE y4 MINI PIER CAPACITY 3004 LBS. 4507 LBS. 6009 LBS, 7511 LBS. 9013 LBS: 10,516'LBS. it 24" X 24" PIER FOOTER SPACINGS* (MIN. 576 SQ.IN) MAXIMUM I=BEAM . PIER SPACING FLOOR MAXIMUM PIER SPACING .(SOIL BEARING CAPACITY) 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) ,WIDTH 12 'WIDE FLOOR** 95 1/2", SEE NOTE N4 SEE NOTE #4 SEE NOTE N4 . SEE NOTE #4 SEE NOTE N4 14I" WIDE FLOOR-- 81" SEE NOTE #4 SEE NOTE q4 . SEE NOTE y4 . SEE NOTE p4 SEE NOTE #4 16 it .WIDE FLOOR•• 74" 115" SEE NOTE #4 SEE NOTE a4 SEE NOTE #4 SEE NOTE N4 18 " WIDE FLOOR-- .65" 101" SEE NOTE q4 SEE NOTE #4 . SEE NOTE p4 SEE NOTE g4 MI I11 PIER CAPACITY 4000 LBS 600.0 LBS 8000 LBS... 10.000 LBS. 12.000 LBS. 14.000 LBS. NOTE: UNIT WIDTHS WITH •• INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. i FOR TYPICAL PIERS SEE .PAGE SU-01-0021 N ES: ME -FABRICATED PIER PADS MAY BE USED AS AN ALTERNATE TO THE CONCRETE HOMES EN OV : • , ���� !�� DAPIA APPROVAL: r�� �.•" GN''TE'S •:�~ �' �4� Na. C ' '• �` - �s �f 1. 'OOTINGS SPECIFIED IN THE JACOBSEN, SET-UP MANUAL. : . Y ��� O3" �r 2. °AN ME PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE - 3I034 . VVVV[C[PPROVED BY UFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM IIER CAPACITIES SHOWN ABOVE. '� '. STA - : w QCT 1 1 3. DOMES LL OTHER REOUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN INSTALLATION INSTRUCTIONS.�0�"• • 4. PIER SPACING 8' FOR UNITS WITH 8" 1-BEAMS /.1O' FOR UNITS WITH 10" OR ••��,!,AX.ri Ea N•��;� �¢� ' ••INC. 2' I -BEAMS (24' MAX. FROM.ENDS). S EOERAL MANUFACTURED HOAtE JACOBSEN HOMES NOTICE: THESE SPEOnCAIMS AND DRAMM ARE DRAWN BY:. DA. T. 09 ' 2M1. REV. LETTER: I ❑ nn uu P.O. BOX 368 ORIGINAL, PROPWETARY. AND CONFIDENDAL MATERIALS OF JACOBSEN MANUFACTURING RIA INC. SUCH MATES ARE PROMDED TO INE DRAWING TITLE: PREFAB. 17 X 254 24" PIER PAD SPACING n SAFETY HARBOR. FLORIDA 34695 PHONE (813) 72671138 REOFUT FOR SPEOM PURPOSES AND WSI BE NEPT CWDENML AHO SEW RROM OTNERS . DRAWING NUMBER: SU-01-0025 . 26" X 26" PIER FOOTER SPACINGS* I (MIN. 676 SQ.INj MAXIMUM I -BEAM PIER SPACING �If FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR-- 113 1/2' SEE NOTE #4 SEE NOTE y4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR** 96 1/2" SEE NOTE #4 SEE NOTE y4 SEE NOTE #4 SEE NOTE y4 SEE NOTE #4. 160" WIDE FLOOR** 87 1/2' SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE q4 184' WIDE FLOOR** 77" 119 1/2" SEE NOTE #4 SEE NOTE p4 SEE NOTE N4 SEE NOTE y4 MIN. PIER CAPACITY 4694 LBS. 7042 LBS. 9389 LBS. 11,736 LBS. 14,083 LBS. 16.431 I NOTE: UNIT WIDTHS WITH •• INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 NOTES:r' AS AN ALTERNATE TO THE CONCRETE EN OV L k •-/ °�,. ••; DAPA APPROVAL• p/ 5E� GA$L 1. PRE -FABRICATED PIER PADS MAY BE USED FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET-UP MANUAL. vP.•'G\ST[qe: �, �'Q� No. U � G- T �/� � � • � 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM 910334 ', a T = APPROVED BY PIER CAPACITIES SHOWN ABOVE: TO AS SPECIFIED IN THE JACOBSEN a,ti �E E •, S A-M :• = ; 3. ALL OTHER REOUIREMENTS ARE TO BE ADHERED .a9 f �' 'R �� OCT HOMES INSTALLATION INSTRUCTIONS. ���r�� !• Nil�' 4. MAX. PIER SPACING 8' FOR UNITS WITH 8' I -BEAMS / 10' FOR UNITS WITH 10" OR . N INC.12' I -BEANS (24' MAX. FROM ENDS). / FnF + ! r IW. Fn Hnr..tc JACOBSEN HOMES NOTIC THESE SPECIFICATIONS AND DRAWINGS ARE 'DRAWN BY: D.I.T. DLMSTRUCIION AND SAFE 09-22-01 Y Tr.At , DRAWING TITLE: PRE —FIB. 26" PIER PAD SPACING „ P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONFDENIIAL NC.�SIKH MAATERRALS ARSE SEN PROVIDED TO RING _ DRAWING NUMBER: SU-01 -0026 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 RESENT FOR SPECK PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. 19 PIER FOOTER SIZING CHART FOR MARRIAGE WALL OPENINGS (FOR SIDEWALL OPENINGS SEE NOTE Q3 ) LOAD SPANS SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' w Q 1000 390 sq. in. 494 sq. in. 597 sq. in. 701 sq. in. 805 sq. in. 908 sq. in. 1500 260 sq. in. 329 sq. in. 398 sq. in. 467 sq. in. 536 sq. in. 606 sq. in. -� 2000 195 sq. in. 247 sq. in. 299 sq. in. 351 sq. in. 402 sq. in. 454 sq. in. 2500 156 sq. in. 197 sq. in. 239 sq. in. 280 sq. in. 322 sq. in. 363 sq. in. MIN. PIER CAP. 2708lbs. 3428lbs. 4148lbs. 4868lbs. 5588lbs. 6308lbs. LOAD SPANS w SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' A 1000 409 sq. in. 519 sq. in. 628 sq. in. 737 sq. in. 847 sq. in. 956 sq. in. 1500 273 sq. in. 346 sq. in. 419 sq. in. 492 sq. in. 565 sq. in. 638 sq. in. 2000 205 sq. in. 259 sq. in. 314 sq. in. 369 sq. in. 423 sq. in. 478 sq. in LID 2500 164 sq. in. 207 sq. in. 251 sq. in. 295 sq. in. 339 sq. in. 383 sq. in MIN. PIER CAP. 2841 IDS. 3601 IDS. 4361 lbs. 5121 Ibs. 5881 lbs. 6641 Ibs. LOAD SPANS w SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' Q 1000 428 sq. in. 544 sq. in. 659 sq. in. 774 sq. in. 889 sq. in. 1004 sq. in. 1500 286 sq. in. 362 sq. in 439 sq. in. 516 sq. in. 593 sq. in. 670 sq. in. 01) 2000 214 sq. in. 272 sq. in. 329 sq. in. 387 sq. in. 445 sq. in. 502 sq. in. 2500 171 sq. in. 217 sq. in. 264 sq. in. 310 sq. in. 356 sq. in. 402 sq. in. LQ MIN. PIER CAP. 2975lbs 3775lbs 4575lbs 5375 lbs 6175lbs 6975lbs LOAD SPANS w SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' Q 1000 486 sq. in. 618 sq. in. 751 sq. in. 883 sq. in. 1016 sq. in. 1148 sq. in. 1500 324 sq. in. 412 sq. in. 501. sq. in. 589 sq. in. 677 sq. in. 766 sq. in. °o 2000 243 sq. in. 309 sq. in. 375 sq. in. 442 sq. in. 508 sq. in. 574 sq. in. 0 2500 194 sq. in. 247 sq. in. 300 sq. in. 353 sq. in. 406 sq. in. 459 sq. in. MIN. PIER CAP. 3375lbs 4295lbs 1 5215lbs 6135lbs 70551bs 7975lbs NOTES: (D SEE DETAIL *5 PAGE SU-01-0001 FOR BLOCKING AND ANCHORING OF MARRIAGE WALL OPENINGS WADER THAN 49 INCHES. QSEE NOTES: Q2 , Q3 , AND ® UNDER AT HLE I, PACE SU-01-0040. Q3 FOR ALL UNIT wDTH5, USE 177 sq/in PIER FOOTER UNDER SIDEWALL OPENINGS THAT ARE 49 INCHES TO 96 INCHES WADE. FOR OPENINGS THAT ARE 96 INCHES TO 144 INCHES. USE 242 sq/'n PIER FOOTER UNDER SIDEWALL OPENINGS. (YIN. 1000 PSF SOIL BEARING REO'D) ® FOR PROPER LOAD SPANS, SEE SU-03-0001. ('LOAD SPANS' ARE CLEARSPANS: PIER SPECIFICATIONS ABOVE ASSUME CLEARSPAN OCCURS ON ONE SIDE OF PIER ONLY — IF CLEARSPAN OCCURS ON BOTH SIDES, ADD VALUES LISTED ABOVE FOR EACH CLEARSPAN) CHECK WITH LOCAL JURISDICTION TO DETERMINE THE SOIL VALUE ON YOUR SITE OR HAVE A SOIL BEARING TEST PERFORMED ON YOUR SOIL TO DETERMINE THE VALUE. CALCS. GQ'. 'G\STEq� •�l '',. Q No. o 910334 �O�•,,TATE O�F •:�� ; J AC O B S E N HOMES THESE SPECIFICATIONST AND oRAWrlcs AR ORIONAL. PROPRIETARY. AND CONFIDENTIAL P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE SAFETY HARBOR, FLORIDA 34695 RECFIENT FOR SPECFIC K4MSES AND WST BE PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS B.E.M. WINDZONE III (110 MPH) ALL EXPOSUR 20 PSF ROOF 10 PSF D.L. APPROVED EY N114INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS MAR 0 1 1999 WE: 2-.6-99 REV. LETTE ITER SIZING CHART n R. WALL OPENINGS /—'� SU-01-0030 21 TABLE I PIER FOOTER SIZING AND PIER SPACING CHART (SEE NOTES BELOW) 12- WIDE WIDTH MAXIMUM Qi Q5 PIER SPACING SOIL BEARING PSF CAPACITY Q2 © REQUIRED PIER FOOTER AREA, SQ. IN. 3'-0" MAXIMUM FROM EACH END 1000 655 AND 8'-0" ON CENTER MAXIMUM 1500 437 (MINIMUM PIER CAPACITY 4548#) 2000 327 2500 262 4'-0" MAXIMUM FROM EACH END 1000 808 AND 10'-0" ON CENTER MAXIMUM 1500 538 (MINIMUM PIER CAPACITY 5608#) 2000 404 2500 323 13'- 4"- WIDE WIDTH MAXIMUM Q 0 PIER SPACING SOIL BEARING PSF CAPACITY Q © REQUIRED PIER FOOTER AREA, SQ. IN. 3'-0" MAXIMUM FROM EACH END 1000 716 AND 8'-0" ON CENTER MAXIMUM 1500 478 (MINIMUM PIER CAPACITY 5014#) 2000 358 2500 287 4'-0" MAXIMUM FROM EACH END 1000 884 AND 10'-0" ON CENTER MAXIMUM 1500 590 (MINIMUM PIER CAPACITY 6191#) 2000 442 2500 354 15'-4"-WIDE WIDTH MAXIMUM 05 PIER SPACING SOIL BEARING PSF CAPACITY (2 © REQUIRED PIER FOOTER AREA, SQ. IN. 3'-0" MAXIMUM FROM EACH END 1000 807 AND 8'-0" ON CENTER MAXIMUM 1500 539 (MINIMUM PIER CAPACITY 5615#) 2000 404 2500 323 4'-0" MAXIMUM FROM EACH END 1000 1000 AND 10'-0' ON CENTER MAXIMUM 1500 666 (MINIMUM PIER CAPACITY 6941#) 2000 500 2500 400 NOTES: Q1 ON MULTIPLE SECTION HOUSES, CHECK EACH SECTION INDIVIDUALLY. Q2 UNDISTURBED SOIL OR 90% COMPACTION FOR FILL. Q3 ALL FOOTERS TO BE BELOW FROST LINE. ® MORE THAN ONE PIER MAY BE USED TO ACHIEVE THE MINIMUM SQUARE INCHES REQUIRED. Q ALL UNIT WIDTHS TO INCLUDE 6" SIDE OVERHANG ONE SIDE OR ONE Y OVERHANG ON EACH SIDE MAXIMUM. © CHECK WITH LOCAL JURISDICTION TO DETERMINE THE SOIL VALUE ON YOUR SITE OR HAVE A SOIL BEARING TEST PERFORMED ON YOUR SOIL TO DETERMINE THE VALUE. ALL ZONES ALL EXPOSURES 20 PSF* ROOF 10 PSF D.L. REF. CALCS. GWfi-?15 191- 95, 02- NUN;Wy ,rVA, �Q 910334 $TAT fF 01= c� J AC O B S E N HOMES THESE SPECIRGinON-S ;Z DRANNCs ARE ORIGINAL. PROPRIETARY, AND COWDENTIAL P.O. BOX 368 MAISIALS OF ACOBSEN MANUFACTURING AM I SAFETY HARBOR, FLORIDA 34695 Mo MUSTTHE MCFIDITT F RAW BE PHONE (727) 726-1138 IVY CONRDGM AND SaW FROM OTIM M.T. DAPIA APPROVAL APPROVED EY INC FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS MAR 0 1 1999 DATE I REV. LETTEF 2-8-99 SPECS CHART A SU-01-0040 22 MOBILE HOME SET-UP DIM. 'A' I DIM. 'B' COLUMN #1 COLUMN #2 COLUMN #3 COLUMN SUPPORT SPANS TO PROPERLY SIZE PIERS LOCATED AT RIDGE BEAM SUPPORT COLUMNS, SURVEY THE ARRANGEMENT OF THE ROOMS IN THE MOBILE HOME TO LOCATE THE OPENINGS ALONG THE MARRIAGE WALL OF THE HOME. MEASURE EACH OPENING IN THE MARRIAGE WALL PAYING ATTENTION PARTICULARLY TO OPENINGS GREATER THAN 4 FEET WIDE. IN THE EXAMPLE ABOVE TO DETERMINE THE SPAN FOR COLUMN #1 SIMPLY USE DIMENSION 'A'. TO DETERMINE THE SPAN FOR COLUMN #2 ADD DIMENSION 'A' AND DIMENSION 'B' TOGETHER. THE SPAN FOR COLUMN #3 CAN BE DETERMINED THE SAME WAY AS COLUMN #1 SIMPLY USE DIMENSION 'B'. ONCE THE COLUMN SPANS HAVE BEEN DETERMINED, FIND THE CORRESPONDING PIER FOOTING SIZE IN THE CHART (SU-01-0030). ❑❑❑❑ JACOBSEN HOMES ❑❑E❑ ❑„❑ P.O. BOX 368 4695 ❑❑❑❑ HONE SAFETY HARBOR FLORIDA NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PRONDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. 23 DRAWN BY: DATE: S.A. 6-6-94 oRAwINc TITLE - COLUMN SUPPORT SPANS DRAWING NUMBER: SU-03-0001 REV. LETTER: SET UP NOTES (CLOSE UP) YOUR HOME IS EQUIPPED WITH A FACTORY INSTALLED HATE LINE QASKET. THE MATE LINE GASKET MUST BE INSPECTED BEFORE BRINGING THE HOME SECTIONS TOGETHER -IF THE GASKET IS DAMAGED, IT MAY BE REPAIRED WITH A FABRIC TYPE TAPE, AND IF DISLODGED, IT MUST BE REATTACHED. THESE ARE (3) SUGGESTED (NOT REQUIRED) ITEMS TO HELP ELIMINATE AIR INFILTRATION. 1. FABRIC TYPE TAPE ADHERED TO BOTH SEC11ONS BEFORE APPLYING ON -SITE FINISH MATERIALS. 2. THERMO-PLY STRIPS OR EQUIVALENT (2" WIDE MIN.) FASTENED TO BOTH SECTIONS WITH NAILS OR STAPLES BEFORE APPLYING EXTERIOR FINISH MATERIALS. (NOTE: THE ROOF IS MATERIAL AND APPLICATION SPECIFIC.) 3. SMALLER GAPS APPROX. 1/4" WIDE MAY BE SEALED WITH A BEAD OF LATEX CAULK. (NOTE: A FOAM SEALANT MAY BE USED IN LIEU OF A LATEX'CAULK.) BEFORE SETTING MULTIPLE WIDE UNITS, THE CLOSE-UP PLASTIC SHIPPING MATERIAL MUST BE REMOVED FROM ALL EXTERIOR WALLS OF ALL SECTIONS. THE SHIPPING PLASTIC MAY BE LEFT IN PLACE ON ALL MATING OR MARRIAGE WALLS OF EACH SECTION, BUT THE PANEL STRIPPING MATERIAL SECURING THE CLOSE-UP SHIPPING PLASTIC MUST BE REMOVED TO ALLOW THE MULTIPLE WIDE SECTIONS TO BE BROUGHT TOGETHER WITH MINIMUM GAPPING BETWEEN THE SECTIONS. THE SHIPPING PLASTIC IS TO BE REMOVING SHIPPING STRIPS). AFTER THE SECTIONS ARE SET TOGETHER THE CLOSE-UP PLASTIC, IF LEFT ON THE MARRIAGE WALLS, IS TO BE CUT-OUT AT ALL OPENINGS TO THE OTHER SECTIONS. WHEN THE HOME'S RETURN AIR GRILLE IS LOCATED IN THE MARRIAGE WALL, THE FRAMING, IS TO BE SEALED WITH LATEX CAULK OR FOAM SEALANT. AFTER REMOVAL OF THE GALVANIZED WIND DEFLECTOR(S) LOCATED ON THE ROOF AT THE HITCH END OF EACH SECTION OF THE HOME, SEAL ALL FASTENER PENETRATIONS OF THE .ROOF SHINGLES WITH A ROOFING CEMENT OR OTHER SUITABLE MATERIAL. THE GALVANIZED WIND DEFLECTOR IS TO BE USED FOR THE ROOF CLOSE-UP, SEE AD-FA-0025 (AD-FA-0026 FOR TRIPLE WIDES). NOTE: BEFORE INSTALLING A CEILING FAN, INSTALL A 4 CU. IN. MINIMUM BOX EXTENSION. (CHECK FACTORY INSTALLED CEILING BOX FOR LABELING INDICATING SUITABLE FOR DIRECT ATTACHMENT OF CEILING FAN FIXTURE -IF NOT LABELED AS BEING SUITABLE, YOU MUST INSTALL A HOOK TYPE CEILING FAN -INSTALL HOOK THROUGH BOX INTO LUMBER BACKER BEHIND FAN BOX.) THE SAFETY CHAIN FOR ALL EXTERIOR OUTSWING DOORS SHALL BE INCLUDED IN THE SET-UP KIT. THE SAFETY CHAIN SHALL BE INSTALLED WHEN THE HOME IS SET-UP. INSTALL THE SAFETY CHAIN PER THE MANUFACTURERS SPECIFICATIONS INCLUDED WITH THE SAFETY CHAIN HARDWARE. FASTEN ALL EXTERIOR SIDING TRIM WITH 7/16" X 1" x 16 GA. STAPLES (OR EQUIVALENT) 6" O.C. MAXIMUM THROUGH SHEATHING INTO WALL OR FLOOR FRAMING. (UNDER HOME VENTILATION) WHEN ENCLOSING THE SPACE FROM THE BOTTOM OF YOUR HOME TO THE GROUND (SKIRTING, FOUNDATION WALLS, OR OTHER METHODS) THE AMOUNT OF VENTILATION REQUIRED IS TO BE DONE TO THE LOCAL CODES AND INSPECTED BY THE AUTHORITIES HAVING JURIDICTION. JACOBSEN HOMES NOTICM � sPEaFtcenas AM DRAMNGS ARE DRAWN BY: M.T. DATE 12-22-94 REV. LETTER: ORIMAL, PROPWARY, AND CGNFlOENTIAL MATEwas OF JACOM MANUFACTURING DRAWING TITLE: UP NOTES P.O. BOX 368 SET SAFETY HARBOR, FLORIDA 34695 N1G SUCH MATMALS ARE PRDNDED TO nE pEWW FOR 9ECf1C ROM AND MOST BE DRAWING NUMBER: o2-t2-ae PHONE (727) 726-1138 WT ODK10EN & AM SEW FROM OTTERS SU-05-0001 24 EXTERIOR ROOFING CLOSE-UP RIDGE SHINGLES OR TABS CUT FROM THREE —TAB SHINGLES FURNISHED IN THE SET—UP MATERIALS APPLIED'OVER COMPLETED SHINGLE ROOFING I (INSTALL RIDGE SHINLGES PER ++ I MANUFACTUERS INSTALLATION INSTRUCTIONS.) + I +I I I+ I I I I I I + + .nlll,. illllr + � iIIIN � �luw •mll,. �IIII,. .,IIII. - / •illll,. �Ilu. •nln. ..III,.. .nllp. ill wl• � illll. � +IIIN �Illli — COMPLETE SHINGLE ROOFING BY INSERTING FINISHING COURSE(S) OF SHINGLES TO EXISTING SHINGLES INSTALLED AT THE FACTORY. LIFT THE UPPER ROW OF SHINGLES AT THE TABS TO INSERT FINAL COURSE OF SHINGLES AND FOLLOW THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS FOR FASTENING. (THIS APPLICATION FOR TRIPPLE WIDES ONLY) NOTES: 1. RIDGE SHINGLES ARE FACTORY APPLIED ON TRIPPLE WIDE HOMES, AND MUST BE APPLIED DURING SET—UP FOR DOUBLE WIDE HOMES. — COMPLETE SHINGLE ROOF BY ADDING FINISHING COURSE(S) TO SHINGLES INSTALLED IN THE FACTORY. ALLOW TOP END OF TOP ROW OF SHINGLES TO EXTEND ACROSS RIDGE ONTO OPPOSING SECTION OF MULTIPLE WIDES. (SEE SU-05-0011 FOR SHINGLE FASTENING REQUIREMENTS.) ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE n""'� �' S.A. "16 6-6-94 ^� ��"" ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE EXTERIOR ROOFING CLOSE-UP ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 , KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-05-001 O 25 SHINGLE INSTALLATION r,rrr r, ern r,uan /rvn \ .» ,R..,,..,.. .......f,,, a _z,,.... co MOB SEE PAGE RC-19-0002 NOTES: 1. SHINGLES FASTENED W/ MIN. 1" X 3/4" X 16 GA. STAPLES AS SHOWN IN THE SHINGLE FASTENING DETAIL. IF A STAPLE IS OVER -DRIVEN, PROPERLY INSTALL ANOTHER STAPLE RIGHT OR LEFT OF OVER -DRIVEN STAPLE AND SEAL OVER -DRIVEN STAPLE WITH ROOFING CEMENT. 2. WHEN METAL DRIP EDGE IS INSTALLED, IT IS NOT NECESSARY FOR SHINGLES TO OVERHANG THE RAKE (FRONT & REAR) EDGE OF THE ROOF. 3. SHINGLE UNDERLAYMENT FASTENED TO DECKING W/ MIN. 3/8" X 3/4" X 18 GA. STAPLES MIN. (TACKED DOWN UNTIL SHINGLES ARE APPLIED). 4. METAL DRIP EDGE FASTENED TO DECKING W/ MIN. 3/8" X 3/4" X 18 GA. STAPLES 12" O.C. MAXIMUM. 5. SHINGLE ROOF COVERINGS WHICH ARE SECURED W/ 6 FASTENERS PER SHINGLE THROUGH AN UNDERLAYMENT WHICH IS CEMENTED DOWN TO 3/8" STRUCTURAL RATED ROOF SHEATHING NEED NOT BE EVALUATED FOR DESIGN WIND PRESSURES. FASTENING DETAIL NOTE: SHINGLES INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS ONLY WHEN SPECIFIC APPLICATIONS ARE NOT COVERED WITHIN THIS MANUAL. ooEo JACOBSEN HOMES ❑,F❑ P.O. BOX 368, 901 4th ST. NORTH [JUDE SAFETY HARBOR, FLA. 34695 PHONE (813) 726-1138 SHINGLE INSTALLATION I © 6-6-94 REVISIONS: � DATE: 12-21-94 26- SU-05-0011 I EXTERIOR FINISH CLOSE-UP SOFFIT AND FASCIA APPLICATION DETAIL METAL DRIP EDGE SOFFIT MATERIAL FASCIA MATERIAL LAP RECEIVER (J CHANNEL) NOTES: 1. ALL MATERIALS REQUIRED FOR ON SITE COMPLETION OF THE LAP SIDING APPLICATION IS SHIPPED INSIDE THE HOME WITH THE SET—UP KIT. 2. FIRST LOCATE AND SECURE THE SOFFIT MATERIAL TO EACH SECTION OF THE HOME WITH EITHER STAPLES, NAILS, OR SHEET METAL SCREWS 6" O.C. 3. NEXT LOCATE AND SECURE THE FASCIA MATERIAL IN THE SAME MANNER AS LISTED ABOVE FOR THE SOFFIT. 4. THEN COMPLETE THE APPLICATION OF BOTH THE METAL DRIP EDGE AND THE LAP SIDING RECEIVER. 5. AFTER ALL PARTS HAVE BEEN JOINED AT THE MATING EDGES OF EACH SECTION OF THE HOME, BEGIN WITH THE LAP SIDING APPLICATION. START THE LAP SIDING APPLICATION AT THE BOTTOM OF THE HOME AS SHOWN IN THE LAP SIDING APPLICATION DETAIL BELOW. ALL TRIM AROUND OPENINGS (ie. WINDOWS AND DOORS) IS COMPLETED BEFORE THE HOME IS SHIPPED. LEAVE AMPLE ROOM AT ALL TRIM FOR THE LAP SIDING TO EXPAND AND CONTRACT WITH TEMPERATURE CHANGES. FOR ANY .ADDITIONAL INFORMATION REQUIRED SEE THE MANUFACTURERS INSTALLATION INSTRUCTIONS PLACED INSIDE THE SET—UP KIT SHIPPED WITH THE HOME. LAP SIDING FASTENING: 1. SECURE HORIZ. LAP SIDING W/ MIN. 7/16" X 1" X 16 GA. STAPLES 16" 0. C. MAXIMUM THROUGH SHEATHING INTO STUD. SECURE ALL EXTERIOR TRIM W/ MIN. 7/16" x 5/8" x 15 GA. STAPLES AT 6" 0. C. MAXIMUM. 2. WITH METAL LAP STAPLE CROWNS MAY BE EITHER PARALLEL OR PERPENDICULAR TO NAILING FLANGE WITH BOTH LEGS OF STAPLE PENETRATING THE NAILING FLANGE. 3. WITH VINYL SIDING STAPLE CROWNS TO BE PERPENDICULAR TO NAILING FLANGE WITH ONE LEG CENTERED IN SLOT AND OTHER LEG ON OUTSIDE OF NAILING FLANGE WITH APPROX. 1/32" SPACE BETWEEN STAPLE CROWN AND NAILING FLANGE. 4. ALL FASTENERS TO BE WEATHER RESISTANT. BOTTOM STARTER STRIP HOOK STARTER LAP ON STARTER STRIP LAP SIDING APPLICATION DETAIL ❑❑❑❑ J A C O B S E N HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. DATE: 12-22-94 REV. LETTER: DRAWING TITLE: ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE EXTERIOR FINISH CLOSE-UP DRAWING NUMBER: SU-05-OO20 ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND,MIkT BE KEPT CONFIDENTIAL AND SECRET FROM 'OTHERS. 27 MOBILE HOME SET-UP/CLOSE-UP SITE INSTALLED EXTERIOR SIDING APPLICATION SEE OTHER DETAILS (SU-05-0031 THRU 0034) FOR PLAN VIEW DETAILS IDENTIFING AREAS REQUIRING EXTERIOR SIDING TO BE SITE INSTALLED. SEE SU-05-0020 FOR LAP SIDING FASTENING, AND SOFFIT AND FACIA APPLICATION. ALL AREAS WHERE THE EXTERIOR SIDING MATERIALS EXTEND ACROSS THE MATING LINE BETWEEN MULTIPLE WIDE UNITS ARE REQUIRED TO BE FINISHED ON SITE TO PREVENT A CONTINUOUS SEAM IN THE EXTERIOR SIDING LOCATED AT THE MATING LINE(S) OF THE HOME. ALL TRIM AND EXTERIOR SIDING MATERIALS ARE PROVIDED IN THE HOME SET—UP KIT FOR COMPLETION OF ALL EXTERIOR SIDING APPLICATIONS FOR THE HOME. THE STARTER STRIP FOR THE LAP SIDING APPLICATION IS INSTALLED AT THE FACTORY TO ENSURE STRAIGHT ALIGNED APPLICATION OF THE SIDING. ALL TRIM MATERIALS NOT REQUIRING FASTENING TO MORE THAN ONE SECTION OF MULTIPLE SECTION HOMES IS ALSO FACTORY INSTALLED TO ENSURE PROPER CLEARANCES AND AN ASSURED MATCH TO THE REMAINDER OF THE HOME. ALL TRIM MATERIALS SECURED TO MORE THAN ONE SECTION OF THE HOME ARE TO BE FASTENED TO THE WALL FRAMING MEMBERS WITH MIN. 7/16" X 5/8" X 16 GA. STAPLES OR 1" ROOFING NAILS 6" O.C. MAXIMUM. TAKE CARE IN LOCATING TRIM MATERIALS TO ENSURE PROPER ALIGNMENT WITH THE FACTORY INSTALLED MATERIALS. ALL FASTENERS USED MUST BE WEATHER RESISTANT TO INSURE DURIBILITY. ENCLOSED WITH THE EXTERIOR SIDING MATERIALS ARE THE MANUFACTURERS INSTALLATION INSTRUCTIONS DETAILING THE RECOMENDED INSTALLATION PROCEDURES AND SPECIFICATIONS FOR THE TYPE OF SIDING BEING USED ON THE HOME. CAREFULLY EXAMINE THE MANUFACTURERS INSTALLATION INSTRUCTIONS BEFORE ANY ATTEMPT TO COMPLETE THE REQUIRED INSTALLATION OF THE EXTERIOR SIDING MATERIALS. SHOULD FOR ANY REASON THE MANUFACTURERS INSTALLATION INSTRUCTIONS BE LOST OR MISSING, CONTACT JACOBSEN HOMES AT 901 4th Street North Safety Harbor, Florida 34695 OR CALL (813) 726-1138 FOR REQUESTING THE INSTALLATION INSTRUCTIONS. SKIRTING MUST BE ATTACHED IN A MANNER SO THE VINYL WILL SLIDE (EXPAND AND CONTRACT). WHEN 6 MIL PLASTIC UNDER HOMES, THE VENTILATION OF THE CRAWL SPACE CAN BE REDUCED TO 1 SQUARE FEET OF VENTILATION PER EVERY 1500 SQUARE FEET. E10001 JACOBSEN, HOMES NOTICE: THESE SPECIFICATIONS DRAWN BY: O.A. I DATE: 06-06-94 REV. LETTER: ❑❑■❑ P.O. BOX 368 AND DRAWINGS ARE ORIGINAL, PROPMEMY, AND CONFIDENRAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: SIDING APPLICATION n ❑„❑ INC. SUCH MATERIALS ARE PROVIDED TO THE EXTERIOR /j,\ it ❑❑❑❑ SAFELY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 REMOT FOR SPECIFIC PURPM Am WM DE KEPT CONFIDENTIAL AND SECRET FROM OTHERS DRAWING NUMBER: SU-05-0030 (09-30-08) 28 29 � 11L 1 3 1�1 7 N INC. Tk J6;T yit�lY>_ o �I o 0 ii o00 , !� �111�v►�t.: � - I I if �� ,; _� � � - � • - I-.i�t�� x-Ylut�zrrh�lx I ATH I'i• �� .. �.i'�--�. �rc� ..- _ � -. _ � - ---= IG' e� I'.tr° STvv. CZ`rP) �'� S�f-oS-Go�2 - UyA-L(_ 1- 6 1J {cni k-kLe-V�er _ APPROVED BY 7N7PJUL 1 3 M raw INS .�xj�R►o� �J�� ��n-��I►r�� _ I I��i P�LL?�T10tJ luav�K v��:�n,s+v►.�� ��. p Aur A. `�-ut=JEV05-or1 . I ! � jnllt�•pOh� _ . i I•�� I .� iph�i----•-� , � � ; - .. _ I!/(a/LXYIL �C2Y2 1Gtsi�•�CVI<�S�I��2�y( lES 3-710"o.c.oEZ' ��(vtx�� D.G�— - I�i6r� X"j�tC==oM��X(�I��2-' �-F� •¢�"OL-'^}� - - _.��, F i-'?F �/� I�IYL. � �I IJ � I ►Js��a-i ► ct�l Cep F �r-u�,) F�j�rl Vit.11'�- SI�rIC:r I�ITI-j- I- I &ark. K-illilrzl�N X 2yezo -- _-aLzZ-tGG�:XYIt�"1c il�i."sites I Co"O.G. Iht��j1J� CMItiI.) 52--65-0033 d�'1 � • 7�9 4 ��t PAY= k�3Ca l e _ T't"t''G VINYL StfltN(�'-INSt�L.hPG� it j MOBILE HOME SET-UP SHUTTER INSTALLATION: SHUT1 RS ARE NORMALLY FASTENED BY SCREWING DIRECTLY THROUGH THE VINYL SIDING. THIS TENDS TO RESTRICT SIDE -TO -SIDE MOVEMENT OF THE -VINYL SIDING PANELS. HOWEVER, SEVERAL THINGS, CAN BE DONE TO ELIMINATE BUCKLING OR OIL CANNING OF -THE VINYL SIDING IN THESE AREAS: A. WHEN PANELS RUN FROM WINDOW AREA TO A CORNER POST OR OR J-CHANNEL (OR ANY TYP. VINYL SIDING TRIM) AT THE OPPOSITE END, BE SURE TO LEAVE PROPER CLEARANCE IN THE 'POCKET" - THEN SIDING WILL EXPAND TOTALLY IN. THAT DIRECTION. B. TWO SHUTTERS BETWEEN WINDOWS: THE PANELS THAT WILL BE RESTRICTED BY THE SHUTTER SCREWS SHOULD BE SHORTER LENGTHS (SEAM BETWEEN WINDOWS - NOT ONE CONTINUOUS PIECE OF VINYL) - SIMPLY OVERLAP TWO PANELS IN THIS AREA. PANELS WILL THEN EXPAND TOWARD THE OVERLAP JOINT (SEE DETAIL "A"). OR STAGGER THE SHUTTER SCREWS - INSTALL FIRST SHUTTER, TAKE NOTE OF WHICH PANELS ARE RESTRICTED BY THE SCREWS. THEN INSTALL THE OPPOSITE SHUTTER, POSITION THE SCREWS FOR THIS SHUTTER THROUGH PANELS EITHER. ABOVE OR BELOW THE PANELS RESTRICTED BY THE SCREWS FROM THE FIRST SHUTTER. BY DOING THIS THE PANELS OF VINYL SIDING WILL BE ABLE TO EXPAND IN AT LEAST ONE DIRECTION, SO LONG AS PROPER CLEARANCE HAS BEEN MAINTAINED IN THE "POCKET", AREA OF, THE CHANNEL. (SEE DETAIL "B") I �. DETAIL "B" L111 DETAIL "A" I it ❑❑❑❑ JACOBSEN HOMES NOTICE; THESE AND DRAWINGS ARE DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: DRAWING TITLE: .SHUTTER INSTALLATION ❑❑■❑ORIGINAL, ❑„❑ P.O. BOX 368 PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE DRAWING NUMBER: SU-05-0034 u ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIRC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. . 32 MOBILE HOME SET-UP TIIEDOWNS THERE ARE TWO TYPES OF WIND THAT CAUSE DAMAGE HORIZONTAL AND UPLIFT. YOUR HOME IS DESIGNED FOR THE HURRICANE ZONE (ZONE 111). IF YOU FOLLOW OUR RECOMMENDATIONS YOU WILL PROTECT YOUR HOME FROM BOTH TYPES OF WIND FORCES. IN TIEING DOWN YOUR HOME, YOU MUST USE MATERIALS OF ADEQUATE STRENGTH AND SPECIFICATIONS. ANCHORING EQUIPMENT- (LOAD RESISTANCE) ANCHORING EQUIPMENT SHALL BE CAPABLE OF RESISTING AN ALLOWABLE WORKING LOAD EQUAL TO OR EXCEEDING 3.150 POUNDS AND SHALL BE CAPABLE OF WITHSTANDING A 50 PERCENT OVERLOAD (4,725 POUNDS TOTAL) WITHOUT FAILURE OF THE ANCHORING EQUIPMENT. ANCHORING EQUIPMENT- (WEATHERIZATION). ANCHORING EQUIPMENT (STRAPS, ETC...) EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIORATION AT LEAST EQUIVALENT TO THAT PROVIDED BY A COATING OF ZINC ON STEEL OF NOT LESS THAN 0.30 OUNCES PER SQUARE FOOT OF SURFACE COATED, AND IN ACCORDANCE WITH THE FOLLOWING: SLIT OR CUT EDGES OF ZINC -COATED STEEL STRAPPING NEED NOT BE ZINC COATED. TIE -DOWN STRAPS SHALL BE TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING, 1, 1 /4 INCHES WIDE AND 0.035 INCHES IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL, AND SEALS. ANCHORING NOTE: THERE IS A TENDENCY FOR THE TOP OF THE ANCHOR ROD TO DEFLECT AND MOVE OR 'SLICE" THROUGH THE SOIL WHEN LOADED WITH THE FRAME TIE. THIS IS NOT DESIRABLE. SINCE IT PERMITS THE MOBILE HOME TO BE DISPLACED .DOWNWIND AND TEND TO SLIDE OFF THE PIERS. TO MINIMIZE DEFLECTIONS. AUGER -TYPE AND OTHER ANCHORS USING STEEL RODS SHOULD BE PUT ON AT AN ANGLE SO THEY ARE MORE IN LINE WITH THE DIRECTION OF PULL. THIS CAN BEST BE ACCOMPLISHED BY INSTALLING THE ANCHORS PRIOR TO PLACEMENT OF THE MOBILE VERTIICALLYE TOT. THEICAPACITYLREQUREDSFORETHESIRED, THE STRAPPING BEINGRATTCHED USED APPROVED BY 000 ONJUL 1 3 10 INS FUMI COG= as SA NOT APPLIED DOTO TIE -DOWNS TALTERNA LTRAPS ON ONE Y ON OPPOSITE SIDE SIDES. THE THE HOME MAYY. BE ON PULLED OFF -HE SUPPORTS. _ ,,,.__ _ 6-6-94 SU-07- 0001 33 MOBILE HOME SET-UP (ELECTRICAL ELECTRICAL CONNECTIONS BETWEEN HOME SECTIONS NOTE: NO ELECTRICAL POWER SHOULD BE CONNECTED TO HOMES WHILE MAKING ELECTRICAL CONNECTIONS. ALL ELECTRICAL WORK SHOULD BE DONE BY A QUALIFIED ELECTRICIAN. MATERIAL SUPPLIED 1. APPROPORATE NUMBER OF JUNCTION BOXES TO MAKE 2 CONNECTIONS PER JUNCTION BOX. (SHIPPED LOOSE IN THE SET-UP KIT) 2. WIRE NUTS. 3. JUNCTION BOX COVERS. INSTRUCTIONS A. SECURE JUNCTION BOXES UNDER HOME. B. WIRES HAVE BEEN COLOR CODED; SIMPLY MATCH UP COLOR CO-ORDINATED WIRES WITHIN A JUNCTION BOX AND CONNECT WITH WIRE NUTS. C. PLACE COVERS OVER JUNCTION BOXES. OMITTED CEILING FIXTURES FIXTURES TO BE INSTALLED AT THESE LOCATIONS MUST BE A TWO WIRE FIXTURE WITH GROUND. INSTALL ALL FIXTURES BEFORE TURNING ON MAIN BREAKERS. NOTE: SEE BELOW FOR SERVICE CONDUCTOR SIZES GROUND (GREEN OR BARE) WIRE TO GROUND BAR HOT LEADS (RED & BLACK) CONNECTED TO MAIN -1 BREAKER NEUTRAL (WHITE) WIRE TO NEUTRAL BUSS MINIMUM CONDUIT SIZES: ---�-VL CONDUIT DROP FROM HOME - EXTEND 1 1/2" MINIMUM - 150 AMP TO BELOW GROUND LEVEL OR SEE 2" MINIMUM - 200 AMP LOCAL CODES TYPICAL ELECTRICAL .CONNECTIONS CROSS -OVER CONNECTIONS CROSS -OVER INFORMATION APPLIES TO MULTI -SECTION UNITS CROSS -OVER WIRES ARE COLOR -CODED SERVICE CONDUCTORS MAIN BREAKER HOT NEUTRAL GROUND 150 2 NO. 1 1 NO. 1 N0. 6 200 2 NO. 2 0 1 NO. 2 0 1 NO. 6 NOTE: ABOVE SERVICE CONDUCTORS ARE FOR COPPER ONLY. FOR COPPER -CLAD ALUMINUM REFER TO LOCAL CODES ELECTRICAL PANEL LABEL THIS LABEL IS LOCATED ON OR NEAR THE ELECTRICAL PANEL THE MINIMUM SIZE JUNCTION BOX ATTACHED TO THE CONDUIT FOR SERVICE CONDUCTORS ARE: 9" X 9" X 4" - 150 AMP OR 12" X 12" X 4" - 200 AMP �0�� ❑❑.F-1 JACOBSEN HOMES P.O. BOX 368 SAFETY PHONER 813 70RID 138�95 ( ) NOTICE: THESE SPECIFlC NOTICE: AND DRAWINGS ARE ONGNAL, PROPPoETW AND CONRMTIAL MATERALS GF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROUTO DER THE ffAw FOR KEPT OWDED Nn�il AM SEW OSES p O H DRAWN BY: B.C.K. DATE 03-30-12 REV. LETTER: B DRAWING TITLE SET-UP ELECTRICAL DRAWING NUMBER: SU-09-0001 35 ELECTRICAL CROSS -OVER & TESTING PROCEDURES MARRIAGE LINE I I NOTCHED MARRIAGE WALL PERIMETER JOISTS. - .92" DEEP NOTCH MAX. ELECTRICAL WIRING FROM ONE SECTION TO BE HOOKED -UP IN JUNCTION BOX(S) ELECTRICAL JUNCTION BOX(S) FASTENED TO TRANSVERSE FLOOR JOIST. AFTER ALL ELECTRICAL WIRING CONNECTIONS ARE MADE, SYSTEM MUST BE INSPECTED AND TESTED. (FOR CONTINUITY TEST PROCEDURES SEE SU-09-0020) TESTING THE POLARITY OF THE ELECTRICAL SYSTEM WILL .REQUIRE TEST EQUIPMENT .CAPABLE OF DETERMING INCORRECT WIRING CONFIGURATIONS, AND ALSO SHOULD INCLUDE ADAPTERS FOR VARIOUS CONFIGURATIONS (POLARITY TESTER). USING THIS DEVICE ALL ELECTRICAL CONNECTIONS (INCLUDING OUTSIDE FIXTURES SUCH AS HEAT TAPE RECEPTACLE) ARE INDIVIDUAL TESTED TO ENSURE ALL CONNECTIONS HAVE BEEN PROPERLY MADE. A PIGTAIL CIRCUIT TESTER MAY BE USED AS AN ALTERNATE TEST METHOD FOR LIGHT FIXTURES. PIGTAIL TEST IS AS FOLLOWS: 10T IN BASE OF SOCKET TO GROUNDED FIXTURE CANOPY (LIGHT MUST LIGHT), NEUTRAL TO FIXTURE CANOPY (LIGHT MUST NOT LIGHT), AND A GROUND CHECK TO DETERMINE NO OPEN GROUND. . FAILURE AT ANY FIXTURE REQUIRES REPAIR AND RETEST. NOTE: ALL GROUND LEADS ARE SECURED TOGETHER AND BONDED TO THE JUNCTION BOXES W/ THE LARGEST SIZE CONDUCTOR IN BOX. (ALL REQUIRED JUNCTION BOXES ARE SHIPPED LOOSE IN THE SET-UP KIT) ALL ELECTRICAL WIRING CONNECTIONS TO BE MADE INSIDE LISTED JUNCTION BOX(S) IN COMPLIANCE WITH N.E.C.. - 2005 2. WIRING IN LISTED JUNCTION BOX(S) NOT TO EXCEED CAPACITY OF THE JUNCTION BOX(S) PER N.E.C. - 2005. 3. WIRING TO BE PROTECTED AND SECURED AT MARRIAGE WALL JOISTS WITH WIRE PROTECTOR PLATES INCLUDED IN SET-UP KIT. 4. ELECTRICAL CROSSOVER WIRING TO BE DONE ONLY BY QUALIFIED PERSONNEL. MATCHING IDENTIFIED CIRCUIT WIRING FROM EACH SECTION OF MULTIPLE WIDE HOMES. 5. AFTER WIRING CONNECTIONS HAVE BEEN MADE, REPLACE COVER ON JUNCTION BOX(S), AND REPAIR ANY CUTS OR VOIDS IN THE I� BOTTOM BOARD WITH DUCT TAPE.. ❑❑❑❑ ❑;N❑❑ ❑❑❑❑ JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 NOTICE: THESE SPECIFICATIONS AND DRANINGS ARE MUM. PROMJEEARY. AND CONFIDENIUL MATERIALS OF JACOBSEN MANUFACTIR NG INC. SUCH MATFMULLS ARE PROVOED TO THE RECPIENT FOR SPECFlC PUKES Ala MUST BE IDPT CUMMAL AND SECRET FROM OTHE DRAWN BY: D.M.T. DATE 05-25-06 REV. LETTER: / 1`/. (09-29-08 ` DRAWING TITLE ELECTRICAL CROSS -OVER DRAWING NUMBER: $U-09-00� D 36 MOBILE HOME SET-UP/ELECTRICAL I -BEAM WIRE FROM BREAKER BOX TO GROUNDING TERMINAL #8 BARE COPPER WIRE MINIMUM OUTRIGGER GIRDLING WIRE MAY BE ATTATCHED TO ANY PART OF THE FRAME ASSEMBLY; (NOT REQ'D TO BE ® OUTRIGGER). ANY APPROVED GROUNDING TERMINAL SECURED TO FRAME TO INSURE PROPER GROUND (METAL TO METAL CONTACT INSURED BY USING A STAR WASHER BETWEEN OUTRIGGER AND TERMINAL). TYPICAL ELECTRICAL GROUND NOTE: ALL EXPOSED NONCURRENT CARRYING METAL PARTS THAT MAY BECOME ENERGIZED SHALL BE EFFECTIVELY BONDED TO THE GROUNDING TERMINAL OR ENCLOSURE OF THE DISTRIBUTION PANELBOARD. A BONDING CONDUCTOR SHALL BE CONNECTED BETWEEN EACH DISTRIBUTION PANELBOARD AND AN ACCESSIBLE TERMINAL ON THE CHASSIS. le NO. 8 BARE COPPER J' L-APPROVED GROUNDING TERMINAL BOND WIRE (MINIMUM) ATTACHED TO OUTRIGGER OR I -BEAM (TYPICAL EACH UNIT). TYPICAL ELECTRICAL BONDING GROUNDING AND CONTINUITY TEST THE GROUNDING CONTINUITY TEST MUST BE PERFORMED BEFORE THE FEEDER CONDUCTORS ARE CONNECTED. PERFORM THE FOLLOWING TEST AFTER ALL STRUCTURAL ASSEMBLY, METAL AND TRIM INSTALLATION IS FINISHED: A. CONNECT ONE CLIP OF A FLASHLIGHT CONTINUITY TESTER TO A CONVENIENT GROUND (METAL SKIN, WINDOW FRAME ON METAL SKINNED UNITS, FLOOR DUCT RISER, SCREW HEAD ON RECEPTACLE OR SWITCH PLATE, ETC.) AND TOUCH THE OTHER CLIP TO EACH LIGHT FIXTURE CANOPY (WHERE LIGHT IS MOUNTED TO CEILING OR WALL). THE CONTINUITY TESTER SHOULD LIGHT IF EACH FIXTURE IS PROPERLY GROUNDED. B. REPEAT THESE PROCEDURES FOR ALL DIRECT WIRED APPLIANCES AND FIXTURES. C. USING THE SAME PROCEDURES, CHECK THE CONTINUITY BETWEEN THE FOLLOWING: 1. BETWEEN METAL ROOF AND STEEL FRAME. 2. BETWEEN METAL SKIN AND STEEL FRAME: 3. BETWEEN STEEL FRAME AND GAS PIPING. D. ANY LOSS OF GROUNDING CONTINUITY FOUND IN THE ABOVE WILL REQUIRE INVESTIGATION, CORRECTION, AND RETESTING FOR CONTINUITY. ❑❑❑❑ ❑❑■❑ORIGINAL, JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAK7NCS ARE PROPRIETARY, AND CONFIDENTIAL DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF MANUFACTURING INC. SUCH MATERIALSRIALS ARE ARE PROVIDED TO THE TYPICAL ELECTRICAL GROUND DRAWING NUMBER: ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS SU-09-0020 37 I I EXTERIOR LIGHT FIXTURE INSTALLATION BE SURE ELECTRICAL SERVICE IS DISCONNECTED BEFORE COMING IN CONTACT WITH ELECTRICAL CONDUCTORS I FIXTURE FLASHING RING IN WHITE FIBROUS RING) it l I h WHITE (NEUTRAL) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT BLACK (HOT) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER .AND SECURED WITH WIRE NUT I 0 EXTERIOR ELECTRICAL BOX BARE (GROUND) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT I EXTERIOR LIGHT FIXTURE (LISTED FOR EXTERIOR USE) BEFORE ELECTRICAL SERVICE IS CONNECTED TO THE HOME, INSPECT THE EXTERIOR OF THE HOME AND LOCATE ALL THE. EXTERIOR LIGHT LOCATIONS TO BE INSTALLED ON SITE. (ALL EXTERIOR LIGHT FIXTURES IN PORCH AND OTHER AREAS NOT ALONG THE EXTERIOR WALL AREAS OF THE HOME ARE INSTALLED AT THE FACTORY). THE EXTERIOR LIGHT LOCATIONS CAN BE IDENTIFIED AS EXTERIOR ELECTRICAL BOXES IN THE WALLS USUALLY LOCATED ADJACENT TO EXTERIOR DOORS THAT ARE COVERED WITH BLANK (SOLID) COVERS. TO INSTALL THE EXTERIOR LIGHT FIXTURES, REMOVE THE BLANK COVERS FROM THE ELECTRICAL BOXES AND FEED THE THREE WIRES (IDENTIFIED IN THE DETAIL ABOVE) THROUGH THE FIXTURE FLASHING RING BEFORE THE 11 CONNECTIONS OF THE CONDUCTORS.ARE MADE. THE FIXTURE FLASHING RINGS MUST EXTEND FROM THE OPENING OF THE ELECTRICAL BOX TO THE OUTERMOST EDGES OF THE EXTERIOR LIGHT FIXTURE (EXCESS AMOUNT OF THE FLASHING RING MAY BE TRIMMED OFF AFTER THE FIXTURE IS SECURED TO THE ELECTRICAL BOX). TO INSURE AGAINST THE POSSIBILITY OF AN I ELECTRICAL SHOCK, ALL ELECTRICAL CONNECTIONS SHOULD BE DONE WITH THE ELECTRICAL SERVICE SHUT OFF TO THE HOME. THE WIRE NUTS REQUIRED FOR SECURING THE WIRES WILL BE FOUND INSIDE THE ELECTRICAL BOX FOR THE FIXTURE (THESE WIRE NUTS ARE INSTALLED AT THE FACTORY TO CAP THE CONDUCTORS IN THE ELECTRICAL BOX). THE FIXTURE FLASHING �I RING IS LOCATED IN THE SHIPPING KIT INSIDE THE HOME. III JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWN BY: S.Q. DATE: 6�6-94 REV. LETTER: - Ril„❑ fl u ❑❑❑ ❑❑❑ DRAWING TITLE: LIGHT FIXTURE INSTALLATION DRAWING NUMBER: SU-09-0030 38 MOBILE HOME SET-UP PLUMBING CONNECTIONS CHECK WATER AND DRAIN LINES FOR ANY CONNECTIONS THAT MAY HAVE COME LOOSE DURING SHIPMENT. SHOULD YOUR HOME NOT BE EQUIPPED WITH A MASTER SHUT—OFF VALVE, ONE MUST BE INSTALLED BETWEEN THE HOME AND THE WATER SUPPLY. THE WATER SUPPLY SYSTEM IS DESIGNED FOR A MAXIMUM INLET WATER PRESSURE OF 80 PSI. IF THE LOCAL WATER SUPPLY PRESSURE TO WHICH THE HOME IS BEING CONNECTED EXCEEDS 80 PSI, A PRESSURE REDUCING VALVE SHOULD BE INSTALLED TO LIMIT THE SUPPLY PRESSURE. WHEN HOMES ARE SET IN AREAS SUBJECT TO FREEZING THE EXPOSED WATER SUPPLY LINES MUST BE PROTECTED. AN ELECTRICAL RECEPTACLE IS LOCATED ON THE UNDERSIDE OF THE HOME NEAR THE WATER INLET, AND NEAR ANY CROSSOVER LOCATION WHERE THE WATER LINES ARE EXPOSED. THESE ELECTRICAL RECEPTACLES ARE FOR THE CONNECTION OF AN ELECTRICAL HEAT TAPE. HEAT TAPE USED MUST BE LISTED FOR USE WITH MOBILE HOMES. FOR MULTIPLE SECTION HOMES WITH PLUMBING IN MORE THAN ONE SECTION, LOCATE AND CONNECT THE WATER CROSSOVERS LOCATED UNDER THE FLOOR ALONG THE MARRIAGE LINE BETWEEN THE SECTIONS. TURN THE WATER SUPPLY ON AND CHECK FOR LEAKAGE. CAUTION: DO NOT TURN THE POWER ON TO THE WATER HEATER UNTIL THE TANK IS FULL OF WATER. CONNECT DRAIN DROP OUTS TO COMPLETE ALL FIXTURE DRAINS AND MAIN DRAIN. BE SURE ALL CONNECTIONS ARE MADE TO COMPLY WITH LOCAL PLUMBING CODES. GAS PIPING HOMES WITH GAS PIPING HAVE BEEN FACTORY TESTED FOR LEAKS, HOWEVER, BEFORE CONNECTING THE GAS SUPPLY TO THE SYSTEM ANOTHER PRESSURE TEST IS REQUIRED TO INSURE THAT THERE ARE NO LEAKS AFTER THE HOME HAS BEEN TRANSPORTED AND SET—UP. 1. CLOSE OFF ALL THE GAS APPLIANCE SHUT OFF VALVES. j 2. ATTACH THE GAS TEST FITTING GAUGE. 3. PRESUREIZE THE SYSTEM UNTIL 3 PSI OF AIR PRESSURE IS REACHED. 4. PRESSURE MUST BE MAINTAINED FOR 10 MINUTES WITHOUT ANY INDICATED PRESSURE LOSS. CAUTION: DAMAGE MAY RESULT IF THE SYSTEM IS OVER PRESSUREIZED, THE GAS PIPING SUPPLY SYSTEM HAS BEEN DESIGNED FOR A MAXIMUM PRESSURE OF 14" WATER COLUMN (1 /2 PSI) AND NOT LESS THAN 7" WATER COLUMN (1 /4 PSI). THE GAS PIPING SYSTEM IS DESIGNED TO USE EITHER LIQUIFIED PETROLEUM GAS OR NATURAL GAS. BEFORE TURNING THE GAS ON: 1. BE SURE THE APPLIANCES IN YOUR HOME ARE DESIGNED FOR THE TYPE OF GAS BEING CONNECTED. 2. WHERE APPLICABLE ON MULTIPLE WIDE HOMES, LOCATE "QUICK —DISCONNECT" AND CONNECT. THE "QUICK —DISCONNECT" IS LOCATED UNDER THE FLOOR AT THE MARRIAGE LINE. 3. MAKE SURE ALL CONNECTIONS ARE TIGHT, AND ALL APPLIANCES ARE TURNED OFF. 4. AFTER THE GAS HAS BEEN CONNECTED AND TURNED ON, MAKE SURE ALL THE PILOT LIGHTS ARE LIT. JACOBSEN HOMES NOTICE: THESE sPECD1GATONS AND DRAVANGS ARE DRAWN BY: D.M.T. DALE 3-22-95 REV. LETTER: RODE]HEI P.O. BOX 368 ORIGINAL. PROPRIETARY, AND CONRDENTAL MATERIALS OF JACOBSEN MANUFACTURING WC. SUCH MATERIALS ARE PROVIDED TO 1NEPLUMB. DRAWING TLE: CON. & .GAS TESTSAFETY 34695 BE HARBOR, FLORIDA PHONE (727) 726-1138 RE�xf FOR SPM RAHPm AID MAST KEPT CON MIAL AND SEOU FROM OTHERS. DRAWING NUMBER: SU-11-0001 / /O9-Z9-O8 PLUMBING TESTS WATER SUPPLY PIPING TEST ALL PIPING IN THE WATER DISTRIBUTION SYSTEM SHALL BE SUBJECTED TO A PRESSURE TEST. (MULTI — WIDE. UNITS SEE SU-11-0020A• FOR CROSS —OVER CONNECTION) PRIOR TO TESTING BE SURE ALL PLUMBING FIXTURES ARE CONNECTED EXCEPT WATER HEATER. CLOSE ALL FAUCETS AND RAISE AND HOLD THE FLOAT ARM IN THE TOILET TANK TO SHUT—OFF LEVEL. ALL SHUT—OFF VALVES IN PIPING SYSTEM ARE OPENED FULLY (EXCEPTIONS ARE DISHWASHER AND ICE —MAKER SHUT—OFF VALVE WHICH WILL REMAIN CLOSED) TAKE THE HOT AND COLD SUPPLY LINES AT WATER HEATER AND (FOR TEST PROCEDURE ONLY) CONNECT THEM TOGETHER. OR IF YOU CHOOSE YOU MAY TEST HOT LINES AND COLD LINES SEPARATELY (IN THIS CASE DO NOT CONNECT HOT TO COLD AT WATER HEATER). CONNECT TEST GAUGE AND THEN CONNECT SOURCE OF PRESSURE (AIR' OR WATER MAY BE USED) TO PIPING SUPPLY SYSTEM. PRESSURIZE SYSTEM TO 100 PSI NO LESS AND THEN ISOLATE / DISCONNECT SOURCE OF PRESURE. 1.00 .PSI MUST BE MAINTAINED FOR AT LEAST 15 MINUTES. IF GAUGE SHOWS A DROP IN PRESSURE THERE IS A LEAK IN THE SYSTEM THAT REQUIRES REPAIR. AFTER REPAIR IS MADE RETEST THE SYSTEM, 100 PSI MUST BE MAINTAINED FOR AT LEAST 15 MINUTES. DISCONNECT HOT FROM COLD SUPPLY LINE AT WATER HEATER, AND CONNECT T0. WATER HEATER: DRAINAGE SYSTEM TEST CONNECT ALL DRAIN DROP OUTS TO COMPLETE ALL FIXTURE DRAINS AND MAIN DRAIN. BE SURE ALL CONNECTIONS ARE MADE PER ENCLOSED DRAIN LAYOUT OR TO COMPLY WITH LOCAL PLUMBING CODES.. CAP OR PLUG THE MAIN DRAIN OUTLET. LOCATE THE LOWEST FIXTURE (USUALLY THE SHOWER), THIS WILL BE WHERE YOU NEED TO OBSERVE THE WATER LEVEL. INTRODUCE WATER INTO THE SYSTEM (SEE NOTE #2) UNTIL WATER REACHES DEPTH OF 2" MIN. IN LOWEST FIXTURE. THE. TEST SHALL BE SUSTAINED FOR NO LESS THAN 15 MINUTES WITHOUT EVIDENCE OF LEAKS. VISUALLY CHECK ALL CONNECTIONS MADE ON —SITE FOR LEAKS (FACTORY CONNECTIONS HAVE ALREADY BEEN TESTED). IF WATER LEVEL. IN LOWEST FIXTURE HAS NOT CHANGED. WITHIN THE MINIMUM 15 MINUTES, AND THERE WAS NO EVIDENCE OF LEAKS AT. FITTINGS, THEN' THE DRAINAGE SYSTEM TEST IS COMPLETE. FAILURE TO MAINTAIN WATER LEVEL INDICATES A LEAK IN THE SYSTEM AND REQUIRES REPAIR AND RETESTING. HOME SHALL BE IN A LEVEL POSITION. INTRODUCE WATER TO SYSTEM AT SINK, SHOWER OR TUB. DO NOT INTRODUCE WATER TO SYSTEM AT TOILET BOWL FOR THIS MAY TRAP AIR WITHIN THE SYSTEM. ❑❑❑❑ JACOBSEN HOMES mm sPEc�1c�1I�am m DR DRAWN BY D.M.T. °"'� 09-2s—Os `�" `�` ❑❑■❑ wm mE M NAL PRWWMRY. AND COFSD1W& DRAWING 11TLE ❑,I❑ P.O. BOX 368 MATE VATS OF JACOBSEN YANUFAC1U NG wc SUCH NAIMU ARE PROYM 1O 11E PLUMBING TEST ' - ❑❑❑❑ SAFETY � HONER( 27) 7261D 138 95 IEp jDp g�FRMI O1NO MIE�ff DRAWING NUYBEl� SU-11-0002 MOBILE HOME SET-UP SET-UP KIT PLUMBING FITTINGS FITTING NAME: COUPLER SYMBOL ORIENTATION / USE COUPLING PIPE SPLICING DIRECTION OF FLOW FITTING NAME: SANITARY TEE SYMBOL ORIENTATION / USE SAN. TEE HORIZONTAL TO VERTICAL ONLY FITTING NAME: LONG TURN 90' ELL SYMBOL ORIENTATION / USE 90' ELL MAY BE USED IN ANY ORIENTATION CHECK THE INSTALLATION INSTRUCTIONS FOR MATERIALS REQUIRED AND PLACEMENT OF FITTINGS, NOTE AS SHOWN IN THE DETAILS THE DIRECTION OF FLOW FOR FITTINGS. DIRECTION OF FLOW FITTING NAME: REDUCER BUSHING SYMBOL ORIENTATION / USE BUSHING REDUCE FITTING PIPE SIZE O. = 1 1/2" DROP O = 2" DROP O = 3" DROP O. = 1 1/2" DRY VENT 0 = 2" WET VENT O = 3" MAIN DRAIN - - = 1 1/2" DRAIN LINE � = � = 2" DRAIN LINE = 3" DRAIN ,LINE NOTE: USE A GOOD QUALITY CLEANER AND CEMENT LISTED FOR USE WITH PVC PIPING CONNECTIONS. BE SURE TO FOLLOW THE MANUFACTURERS INSRUCTIONS ON THE CONTAINERS. ALL PIPING REQUIRED TO FIT BETWEEN FITTINGS IS INCLUDED IN THE SET-UP MATERIALS. THE LENGTHS OF PIPE SHOULD BE CHECKED BEFORE CUTTING TO ENSURE THAT PROPER DROP-OFF IS REMAINING FOR COMPLETION OF PIPE RUNS. DRY FITTING ALL PARTS TOGETHER IS RECOMENDED BEFORE ANY FITTING AND PIPE JOINT IS GLUED. NOTICE: DRAWN BY: DATE: REV. LETTER: ❑❑❑❑ JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWINGS ARE S.A. 6-6-94 ❑❑■❑ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE SET-UP KIT. PL. FITTINGS SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: ❑❑❑❑ PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-1 1-0010 4-1 MOBILE HOME SET-UP 2" WET VENT WITH NOT MORE THAN UNVENTED �� (1) FIXTURE DRAIN W.C. DROP - i 2„ i 3" O� D , 2" VENTED W.C. 3" ALT. DROP / TYPICAL O 2" DROP i � INDICATES BOTTOM / 3 / OF HOME i 3„ i / 1 1/2" DRY VENT 2" (SEE ALT. FOR OPT. WET VENT O UNVENTED i CONNECTION) W.C. DROP 2 " i 3" 2- OA i i 0 3„ 0 3„ _ TYPICAL 3" Q 1.1/2" DROP Q O / 3" i i 3" / 1 1/2" 1 1/2" 3" TO ON SITE DRAIN CONNECTION Q �` MINIMUM SLOPE 3" i 1/8" PER FT. /i. WITH CLEAN -OUT 1/4" PER FT: WITHOUT CLEAN -OUT INSTALL FULL SIZE CLEAN -OUT IF SLOPE IS BETWEEN 1/8" k 1/4" PER F00T USE O IF CLEAN - OUT IS NOT NEEDED FITTING SCHEDULE QA VERT. TO HORIZ. (LONG TURN TY OR COMB. Y k 1/8 BEND) OB HORIZ. TO HORIZ. (LONG TURN TY OR COMB. Y h 1/8 BEND) © HORIZ. TO VERT. (1/4 ;BEND -LONG ELL) OD VERT. TO HORIZ. (LONG SWEEP 1/4 BEND) OE HORIZ. TO VERT. (SHORT. TURN TY - SAN. TEE) TYPICAL ON SITE DRAIN CONNECTIONS 3/4" DROP FIR WATER HEATS i / SECTION i ,,,,-3/4" THREADED INLET '4" DROP 3/4" TEE AND --- FRESH WATER INLET FOR - 3/4" THREADED 3/4" ELL TINGLE WIDES AND MULTI- NOTE: INLET - FIELD THE TWO EXAMPLES SHOWN ARE INSTALLED WIDES WITH PLUMBING IN TYPICAL FOR MOST MODELS. ONE SECTION ONLY SOME MODELS DEPENDING 3/4" CROSS-OVERS ON THE PLUMBING LAY -OUT FRESH WATER INLET FOR (FIELD INSTALLED) MAY HAVE A COMBINATION MULTI-WIDES WITH OF BOTH OF THE EXAMPLES SHOWN. PLUMBING IN MORE THAN ONE SECTION TYPICAL FRESH WATER ENTRANCES NOTICE: DRAWN BY: DATE: JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWINGS ARE S.A.. 6-6-94' ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING DRAIN SET-UP INC. SUCH MATERIALS ARE PROVIDED TO THE SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS SU7-1 1-OOOS 42 WATER LINE CROSS -OVER \I/IILI\ VI\VJJ (SEE DETAIL BELOW) I TYPICAL MARRIAGE LINE OF MULTIPLE WIDE HOMES TYPICAL FLOOR ASSEMBLY FLOOR JOIST MAY BE NOTCHED AT PLUMBING CROSS -OVER WATER CROSS -OVER (SEE ELECTRICAL SET-UP FOR SPECIFICATIONS). R-7 INSULATION MINIMUM AND BOTTOM BOARD OVER WATER CROSS -OVER LINES NOTE: NO HEAT TAPE RECEPT. REQUIRED AT INSULATED WATER CROSS -OVER. NOTES: 1. CONNECT WATER LINES TOGETHER AT ALL CROSSOVER LOCATIONS. 2. INSTALL R-7 MINIMUM INSULATION BLANKET OVER THE WATER CROSS -OVER LINES AND SECURE INTO PLACE WITH DUCT TAPE. 3. PLACE A PIECE OF BOTTOM BOARD MATERIAL LARGE ENOUGH TO COVER WATER CROSS -OVER LINES AND INSULATION AND SECURE TO FLOOR FRAMING MEMBERS WITH 1' X 1° X 16 GA. STAPLES MINIMUM AT EACH FRAMING MEMBER, AND TAPE OVER SEAMS WITH CLOTH DUCT TAPE OR EQUAL. ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: C.L.Y. DATE: 10-23-95 REV. LEIIEH: ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF MANUFACTURING DRAWING TITLE: WATER CROSS -OVER ❑"❑ P.O. BOX 368 ARESEN INC. SUCH MATERIALS ARE PRONDED TO THE MATERJACOIALS ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 REOPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-11 -0020 44 MOBILE HOME SET-UP 6. A.C. CONNECTIONS JACOBSEN MOBILE HOMES ARE MADE AIR CONDITIONER READY, WHICH MEANS THE REGISTERS, SUPPLY DUCTS, AND RETURN AIR FACILITIES ARE ALREADY INSTALLED IN YOUR HOME. IN A MULTI — SECTION HOME THERE IS ONE SUPPLY DROP PER SECTION, AND ONE RETURN AIR DROP FOR .THE ENTIRE HOME. CONNECT THE RETURN AIR DROP TO THE INTAKE SIDE OF THE AIR CONDITIONING UNIT, AND CONNECT THE SUPPLY DROPS REDUCER "Y" FITTING(S) (i.e., (1) 12" TO (2) 10") TO THE BLOWER SIDE. FOR SINGLE UNIT HOMES, THERE IS ONE SUPPLY DROP, CONNECT THAT ONE DROP DIRECTLY TO THE BLOWER SIDE OF THE AIR CONDITIONING UNIT. ALL CONNECTIONS BETWEEN THE AIR CONDITIONER AND DROPS CAN BE MADE WITH INSULATED FLEXIBLE DUCT. CHECK THESE ITEMS AFTER THE AIR CONDITIONER IS INSTALLED. 1. ALL DUCT WORK BELOW THE HOME IS INSULATED. 2. ALL SEAMS ARE SEALED. 3. ALL CONNECTIONS ARE INSULATED AND TIGHT FITTING. 4. CROSS —OVER DUCT MUST BE SUPPORTED EVERY. 4'-0" O.C. TYPICAL RETURN AIR DROP . TYPICAL - SUPPLY DROP - TYPICAL SUPPLY DROP REDUCER 'Y' I FITTING AIR FLOW UNIT IS SHOWN WITH TWO SUPPLY AND ONE RETURN DUCT(S). THIS WILL VARY BY MODEL MODELS MAY HAVE MORE OR FEWER SUPPLY OR ALL IN ONE AIR CONDITIONER UNIT (AIR HANDLER, CONDENSER, AND. RETURN DUCTS. COMPRESSOR) TYPICAL MULTIPLE SECTION A.C. CONNECTIONS NOTE: ON SOME MODELS THE SUPPLY AND/OR RETURN AIR DROPS PROVIDED ON THE HOME MAY BE LOCATED DIRECTLY OVER THE RUNNING GEAR (TIRE AND/OR AXLE). ON HOMES WITH THE DROP LOCATIONS LOCATED ABOVE THE RUNNING GEAR IT IS NECESSARY TO REMOVE THE RUNNING GEAR BEFORE HOOKING UP THE SUPPLY AND/OR RETURN AIR DUCT FROM THE AIR CONDITIONER UNIT TO THE HOME. ❑ ❑ ❑❑ JACOBSEN HOMES NOTICE: THESE SPEaRrATIONS AND DRAWNGS ARE DRAWN BY: O.A. DATE 06=06-94 REV. LETIER: DRAWING TITLE: DOUBLE WIDE A.C. CONNECTIONS ❑❑;;� ORIGINAL, PROPRIETARY, AND CONFIDENTIAL NSIjCLS OF MANUFACTURING n P.O. BOX 368 RIALSJACOMARE INC.G SUCH MATERIALS ARE FRONDED To THE '/-�` DRAWING NUMBER: SU-1 3-0001 ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECFIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT 001611 NIIAL AM SECRET FROM 07HM (09-30-08) MOBILE HOME SET-UP USE THE FOLLOWING INSTRUCTIONS WHERE APPLIED TO DUCTWORK PROVIDED BY JACOBSEN HOMES FOR AIR CONDITIONER INSTALLATION. CHECK THE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR ALL ADDITIONAL DUCTS USED DURING AIR CONDITIONER HOOK—UP FOR RECOMMENDED INSTALLATION PROCEDURES FOR THE TYPE DUCT BEING USED. METHOD PRESSURE DETAILS LIMITATIONS TAPE ONLY (FOR LOW PRESSURE o NOT TO EXCEED CONNECTING 2 IN. W.G.) SPLICING CLAMP ONLY ng or pling METAL CLAMP (FOR LOW TO Band MEDIUM PRESSURE i NOT TO EXCEED 4 IN. W.G.)SEE PRESURELIMITATIONS FOR PLASTIC CLAMPS** Duct MIN. CONNECTING OR SPLICING TAPE & CLAMP (FOR LOW, MEDIUM OR HIGH PRESSURE NOT TO EXCEED 10 IN. W.G.) SEE PRESURE CONNECTING LIMITATIONS FOR PLASTIC CLAMPS** SPLICING A) B) C) D) E) F) CONNECTIONS FOLD BACK JACKET AND INSULATION A) FROM END OF DUCT EXPOSING CORE. SLIP CORE OVER FITTING AT LEAST B) 1 1/2 INCHES. APPLY DUCT TAPE* AROUND CORE AND C) FITTING WITH AN EQUAL TAPE WIDTH ON EACH. PULL BACK INSULATION AND JACKET D) OVER FITTING. APPLY DUCT TAPE* AROUND JACKET E) AND FITTING WITH AN EQUAL TAPE WIDTH ON EACH. SLIP DUCT OVER FITTING AT LEAST I A) THREE INCHES. PLACE CLAMP** AROUND DUCT AT FITTING AND TIGHTEN WITH APPROPRIATE TOOL UNTIL ALL MATERIAL UNDER CLAMP HAS BEEN COMPRESSED AND CLAMPING PRESSURE IS ASSURED. CHECK CONNECTION BY PULLING ON DUCT WITH A FORCE OF AT LEAST 25 LBS. TO INSURE DUCT HAS BEEN ADEQUATELY CLAMPED. PULL BACK JACKET AND INSULATION FROM END OF DUCT EXPOSING CORE. SLIP CORE OVER FITTING AT LEAST 1 1/2 INCHES. APPLY DUCT TAPE* AROUND CORE AND FITTING WITH EQUAL TAPE WIDTH ON EACH. PLACE CLAMP** AROUND TAPE AND CORE AND TIGHTEN WITH APPROPRIATE TOOL. PULL BACK INSULATION AND JACKET AND APPLY DUCT TAPE* AROUND JACKET AND FITTING. WITH TABBED DUCTBOARD FITTINGS, OUTER JACKET MAY BE 'DIAPERED' INSTEAD OF TAPED (SEE STEP F). PULL JACKET OVER RING, THROUGH HOLE, AND FOLD UP WITH TABS. SPLICES FOLD BACK JACKET AND INSULATION FROM END OF DUCTS EXPOSINGICORE. INSERT ONE CORE INTO THE OTHER ABOUT THREE INCHES. APPLY DUCT TAPE* AROUND OUTSIDE OF CORE EDGE WITH EQUAL WIDTH ON EACH CORE. BUTT INSULATION AND PULL JACKET FROM ONE DUCT OVER OTHER DUCT. APPLY DUCT TAPE* AROUND OUTSIDE OF JACKET EDGE WITH EQUAL TRPE WIDTH ON EACH JACKET. FOLLOW AS DIRECTED UNDER 'CONNECTIONS' BUTTING TWO DUCTS TOGETHER ON A STANDARD SHEET METAL COUPLING AT LEAST SIX INCHES IN LENGTH. h A) BUTT TWO CORES TOGETHER ON A SIX INCH METAL COUPLING AND FOLLOW DIRECTIONS UNDER 'CONNECTIONS'!. + DUCT TAPE: USE A MINIMUM OF ONE WRAP OF 2 INCH OR TWO WRAPS OF 1 1/2 INCH WIDTH OF TYPE SHUFORD #PC622, TUCK #92T, ARNO #C520, POLYKEN #222, OR NASHUA #357. ++ PLASTIC CLAMPS: PLASTIC CLAMPS ARE NOT RECOMMENDED FOR PRESSURES EXCEEDING 4 IN. W.G. (DIAMETERS 3" — 10") AND 2 IN. W.G. (DIAMETERS 12 AND OVER) TO ACHIEVE PROPER TENSIONING OF PLASTIC CLAMP, SET CORRESPONDING TOOL AT MAXIMUM TENSION SETTING. APPROVED TYPES: PANDUIT TYPE PLT—H (TOOL G); CATAMOUNT L-175 (TOOL L-300); OR TYTON T-150 (TOOL T-150). ❑❑❑❑ ❑❑■❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIIONSAND DRAVANGSARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MANUFACTURING DRAWN BY: S.A. I DATE: 6-6-94 REV. LETTER: _ DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN INC. SUCH MATERIALS ARE PROVIDED TO THE MOBILE HOME SET—UP DUCTWORK DRAWING NUMBER: SU-13-O01 O ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. PHONE (727) 45 ELECTRIC CLOTHES DRYER VENTING IMPORTANT - BEFORE. DRYER IS USED IT MUST BE VENTED.TO THE OUTSIDE OF THE HOME. THE VENT MUST NOT TERMINATE INSIDE THE SKIRTED AREA UNDER THE HOME, THIS WOULD RESULT IN EXCESSIVE HUMIDITY IN THE HOME. HOMES SET UP TO RECEIVE A DRYER ARE EQUIPPED WITH. A VENT HOLE PRE -DRILLED THROUGH THE FLOOR AT THE DRYER LOCATION, TO COMPLETE THE DRYER EXHAUST SYSTEM, FOLLOW THESE PROCEDURES: 1. REMOVE THE DRYER VENT ACCESS HOLE COVER. 2. .CUT DRYER VENT DUCT TO THE PROPER LENGTH, AND CHECK FOR OBSTRUCTIONS. THEN CONNECT TO DRYER IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 3. SECURE THE VENT CAP TO THE OUTSIDE OF THE SKIRTING AT THE APPROPRIATE LOCATION. 4. SECURE THE END OF THE FLEXIBLE DRYER DUCT TO THE VENT CAP AT THE EXTERIOR OF THE HOME WITH CLAMPS. NOTE: DO NOT USE ANY SCREWS OR OTHER DEVICES THAT EXTEND INTO THE DUCT. 5. STRAP THE DRYER DUCT TO THE UNDERSIDE OF THE HOME TO PREVENT THE DUCT FROM COMING IN CONTACT WITH THE GROUND. 6. SEAL THE OPENINGS AROUND THE DUCT WHERE' IT PASSES THROUGH THE FLOOR WITH CAULK OR DUCT TAPE, AND THE BOTTOM BOARD WITH DUCT TAPE. JACOBSEN HOMES WILL NOT BE RESPONSIBLE FOR DAMAGE TO THE HOME RESULTING FROM FAILURE TO INSTALL THE DRYER EXHAUST SYSTEM IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND THE INSTRUCTIONS LISTED ABOVE. NOTE: GAS DRYER INSTALLATION MUST BE DONE BY QUALIFIED PERSONNEL. THE CUTTING OF STRUCTURAL ELEMENTS OF THE HOME, SUCH AS RAFTERS OR FLOOR JOISTS TO EXPEDITE INSTALLATION IS PROHIBITED. ANY WEAKENING OF THE STRUCTURE RESULTING FROM SUCH CUTTING IS NOT THE RESPONSIBILITY OF JACOBSEN HOMES, AND MAY RESULT IN NEGATING YOUR WARRANTY. VSTALLED DUCT ;T BE METAL X OR RIGID CAP CAP �I ❑❑❑❑ ❑❑■❑ ❑„❑ JACOBSEN HOMES P.O. BOX 368 NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL INC. SUCHMATERIALSMATERIALSBAOF ARRE PROVIDED TORTHE unawn tlY: R.R: DATE: 01-21-00 REV. LETTER: n A DRAINING TITLE: ELECT, CLOTHES DRYER VENTING ❑❑❑❑ SAFETYHARBOR, ARBO )F726RIDA3B4695 PHONE RECIPIENT �FOR PEpRICDPURPOSES M SECRET FIM OHM DRAWING NUMBER: SU-15-0001 SITE INSTALLED WATER HEATER PAN DRAIN IMPORTANT - SET-UP OF THIS HOME REQUIRES THAT AN ON -SITE DRAIN BE INSTALLED FROM THE WATER HEATER PAN TO THE EXTERIOR OF THE HOME BEFORE THE WATER HEATER MAY BE USED. WATER HEATER PAN FACTORY INSTALLED DRAIN THROUGH FLOOR�� AND BOTTOM BOARD SITE INSTALLED DRAIN --/- PIPE AND ELBOW (1 /4" PER FOOT MIN. SLOPE) 4'-0'yO.0 DRAIN TO EXTEND. PAST THE EXTERIOR lWALL LINE AND BE LEFT EXPOSED AND VISIBLE FOR INSPECTION. Q (SEE DETAIL 'A') SCREEN FACTORY INSTALLED BETWEEN PIPE AND ELBOW. THIS ASSEMBLY TO BE'' USED AS OVERFLOW PIPE TERMINATION. DETAIL 'A' (DEALER IS RESPONSIBLE FOR THE SHIP LOOSE W/H PAN PIPE ON SITE INSTALLATION) NOTES: 1.) SITE INSTALLED STRAPPING USED TO MAINTAIN THE REQUIRED SLOPE MAY BE SECURED TO FLOOR FRAMING AND/OR CHASSIS MEMBERS. 2.) SHIP LOOSE DRAIN LINE TO BE THE SAME MATERIALS AS THE FACTORY INSTALLED W/H PAN PIPE. ALL MATERIALS FOR THE COMPLETION OF THE ON SITE DRAIN WILL BE SHIPPED LOOSE. 3.) THE WATER HEATER PRESSURE AND TEMPERATURE RELIEF LINE MAY TERMINATE UNDER THE HOME. ❑❑❑❑ ❑„❑❑❑■❑ ❑❑❑❑ J AC O B S E N HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPEgFlCATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE REMW FOR SPECFIC Pins AND MUST BE IVT C01'FIDEN7UV. AND SECRET FROM OTHERS, DRAWN BY: M.T. DATE: 03-08-07 REV. LETTE D Ivl DRAWING TITLE: W/H PAN DRAIN DRAWING NUMBER: SU-15-0003 47- DOWN DRAFT RANGE VENTING IMPORTANT - BEFORE RANGE IS USED IT MUST BE VENTED TO THE OUTSIDE OF THE HOME. THE VENT MUST NOT TERMINATE INSIDE THE SKIRTED AREA UNDER THE HOME, THIS WOULD RESULT IN EXCESSIVE HUMIDITY IN THE HOME. HOMES WITH A DOWN DRAFT RANGE ARE EQUIPED WITH EXHAUST DUCT INSTALLED FROM THE RANGE THROUGH THE FLOOR, THE REMAINING DUCT IS SENT WITH THE HOME AND MUST BE INSTALLED ON SITE. 1. LOCATE DUCT DROP FROM RANGE. (MAY BE EXTENDING THROUGH BOTTOM BOARD, OR SEALED INSIDE) 2. CHECK DUCT PROVIDED FOR PROPER LENGTH, AND OBSTRUCTIONS. THEN CONNECT TO DUCT DROP FROM RANGE IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 3. SECURE THE VENT CAP TO THE OUTSIDE OF THE SKIRTING AT THE APPROPRIATE LOCATION. 4. SECURE THE END OF THE DOWN DRAFT RANGE DUCT TO THE VENT CAP AT THE EXTERIOR OF THE HOME WITH CLAMPS OR SCREWS. -NOTE: DO NOT USE ANY FASTENERS THAT CRUSH OR BLOCK THE DUCT. 5. STRAP THE DUCT TO THE UNDERSIDE OF THE HOME TO PREVENT THE DUCT FROM BENDING OR COMING IN CONTACT WITH THE GROUND. 6. SEAL THE OPENINGS AROUND THE DUCT WHERE IT PASSES THROUGH THE FLOOR WITH CAULK OR DUCT TAPE, AND THE BOTTOM BOARD WITH DUCT TAPE. JACOBSEN HOMES WILL NOT BE RESPONSIBLE FOR DAMAGE TO THE HOME RESULTING FROM FAILURE TO INSTALL THE RANGE EXHAUST SYSTEM IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, AND THE INSTRUCTIONS LISTED ABOVE. RANGE NOTE: DROP LOCATED DIRECTLY BELOW RANGE BLOWER MOTOR SITE INSTALLED DUCT ❑❑❑❑ Hlt:100 JACOBSEN HOMES P.O. BOX 365 SAFE HONETY R( 27) FLORIDA 384695 NOTICE: THESE SPECIFICATIONS AND DRABINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED 10 THE KEEPT C *lDENTIAL FIC AND SECREESFROM MUST BE DRAWN BY: DRAWING TITLE: DOWN DRAWING NUMBER: 48' i VENT CAP DAZE: S.A. 6-6-94 DRAFT RANGE VENTING SU-15-0002 BOTTOM BOARD P—TRAP ACCESS PANELS — TAPE APPLIED OVER ALL SEAMS AT PATCH APPROX. 1" PATCH TO BE SAME MATERIAL AS BOTTOM BOARD BEING REPAIRED. HOLE MAY BE (3) SIDED CUT IN BOTTOM BOARD AND TAPE USED TO SEAL EXISTING MATERIAL BACK OVER OPENING VISUALY INSPECT BOTTOM BOARD OF THE ENTIRE HOUSE TO ASSURE THAT THERE IS NO DAMAGE (RIPS OR TEARS ) AND THE AREA AROUND PROTRUSIONS ARE REPAIRED. P—TRAPS MUST BE CHECKED TO BE SURE THEY ARE WELL INSULATED AND COVERED., NOTES: 1. , P—TRAP ACCESS PANELS WILL BE BELOW P—TRAP AREA IN FLOOR. 2. P—TRAP ACCESS PANELS MAY BE 3 OR 4 SIDED, AND WILL HAVE 1 OR 2 ROWS OF TAPE AT THE PERIMETER OF THE PANEL. 3. NORMAL BOTTOM BOARD REPAIRS WILL HAVE ONLY TAPE OVER THE CUT OR DAMAGED AREA. 4. MINOR HOLES AROUND PIPES ETC. MAY BE SEALED WITH TAPE 5• THESE ARE SOME ACCEPTABLE TAPES TO USE FOR REPAIR; SHURTAPE PC658, FIRST LINE 620 ❑❑❑❑ �;;� ❑❑❑❑ JACOBSEN HOMES P.O. BOX 368 SAFETY HONER(0 7) 7261D 13 4695 NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE ORIGMAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS AT JACORIALS AEN ROVIDE CTO ING THE INC. sugi MATERIALS ARE PROVIDED To THE RT M gaV R YDS4 DRAWN BY: D.M.T. DATE 10-31-01 REV. LETTER: B (10-08-08) DRAWING TITLE: BOTTOM BOARD P—TRAP ACCESS DRAWING NUMBER: SU-15-0010 49 m AIR HANDLER CROSS -OVER CONNECTIONS PLENUM (DUCT CONNECTION BETWEEN CROSS -OVER SUPPLY DISTRIBUTION BOX) I / DUCTS SHALL BE MADE PER OTHER DETAILS. 00 1 f 00 1 CEILING BOARD L--- PLENUM (DUCT I DISTRIBUTION BOX) UNIT MARRIAGE LINE DUCT RISER(S) (SUPPLY DUCTS) AIR HANDLER A/C SYSTEM (AIR HANDLER, ETC...) SUPPLIED BY OTHERS AIR HANDLER CROSS -OVER ELEVATION VIEW rTD DRAWN BY: JACOBSEN HOMES DATE REV. LETTER: THESE sPECIFIG11ONS NS MAHD DRAWINGS AREDRAWINGS.L.Y.. 3-21-95 O� - PRA AND �N�E„>�L DRAWING T1 P.O. BOX 368 MAMAS of .WCo9SEN MANUFACTLX HANDLER CROSS -OVER W_ SUCH MAIMS ARE PROM ED TO THE SAFETY HARBOR, FLORIDA 34695 RECPENT FOR SaEM PULP M AND UM BE DRAWING NUMBER PHONE 813) 726-1138 K" COL MTLAL Alp SEOV FROM OTHERS SU—AC-OI Q0 501.