Loading...
HomeMy WebLinkAboutEPL DISPLAY CARDSCANNED f BY ENEWdYPE' RFORMANCE LEVE L (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 79 The lower the EnergyPerformance Index, the more efficient the home. i LOT#841 VENTURE, ST. LUCIE COUNTY, FL, 1. Newonstruction or existing New (From Plans) 9. Wall Types Insulation Area 2. Sing[ family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1344.00 ft' 3. Num er of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 205.33 ft- c.. N/A R= ft= 4. Num er of Bedrooms 2 d: N/A R= ft. 5. Is thi a worst case? No 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=38.0 963.00 IF 6. Con Toned floor area (W). 963 b. N/A R= ft2 7. WindQi Description Area c. N/A R= ft' a. Nactor: Sgi, U-0.46 155.00 ftz 11. Ducts R IF SHGC: SHGC=0.36 a. Sup. Attic, Ret: Attic, AH: Main 6 185 b. U- actor: N/A ft2 SH C: 12. Cooling systems kBtu/hr Efficiency c. U- actor: N/A ftz a. Central Unit SH C: 24.2 SEER:16.00 d. U- ctor: N/A ft2 13. SH C: Heating systems kBtulhr Efficiency Area eighted Average Overhang Depth: 2.000 ft. a. Electric Strip Heat 17.0 COP:1.0o Area i ighted Average SHGC: 0.360 8. Floor es Insulation Area 14. Hot water systems a. Sla n-Grade Edge Insulation R=0.0 963.00 ft' a. Electric Cap: 40 gallons b. N/A R= ftz EF: 0.92 c. N/A R= ftz b. Conservation features None 15. Credits Pstat I certify th I t this home has complied with the Florida Energy Efficiency Code for Building Constructi' n through the above energy saving features which will be installed (or exceeded) �o�TttF STgl� in this ho �e before final inspection. Otherwise, a new EPL Display Card will be completed based on i stalled Code compliant features. a a Builder Si ature: � � Dater ce�'�'� c o I Home: Address of ew i /�q � � o �'�ilti � City/FL zlp:,� Ca- cf oo WE "Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortg ge (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1 92 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For inform tlon about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's suppo staff. required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGaugee USA - FlaRes2010 Section 405.4.1 Compliant Software 0 Ill 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole. Building Performance Method AD RESS: LOT#841 VENTURE PERMIT #: ST. LUCIE COUNTY, FL, STORY REQUIREMENTS SUMMARY - See individual code sections for full details. W F UNENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air eakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. j Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfmisq.ft. Testing or visual inspection required. j Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. & 403.1 At least one thermostat shall be provided for each separate heating and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies. in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. nical 403.5 Homes designed to operate at positive pressure or with mechanical itilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. ming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4116/13). Heat pump pool heaters minimum COP= 4.0. ig/heating 403.6 Sizing calculation performed & attached: Minimum efficiencies per uipment Tables 503.2.3. Equipment efficiency verification required. Special occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Is/knee walls 405.2.1 R-19 space permitting. 7:22 PM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 7-1177 # System.Typ 1 Central Unit 1 I # System Ty 1 Electric Cooling Cooling Heating Hanfin COOLING SYSTEM "imiltalcy Loapacrty Air Flow SHR Block Ducts None SEER: 16 24.2 kBtu/hr 726 cfm 0.75 1 syslFi HOT WATER SYSTEM SubType Location EF Cap Use SetPM None Main 0.92 40 gal 50 gal 120 deg Conservation None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name None None — Supply — # Location R Value Area 1 Attic 6 185 fF mable Thermostat: Y System Model # DUCTS — Return — Location Area Leakage Type Attic 20 fi2 Default Leakagi TEMPERATURES Jan Feb Mar Apr Lx1J Jan Feb Mar l Jan Feb Mar AAppr at Schedule: HERS 2006 Reference Type 1 2 VD) PM 78 80 80 VEH) PM 78 78 VD) PM 68 68 Aleut .. Ceiling Fans: May Jun May Jun riJun Collector Collector Model # Area ftz Air CFM 25 CFM25 Handier TOT OUT Main (Default) (Default) Storage Volume FEF HVAC # ON RLF Heat Cool 1 1 r ]Jul ri A g X Sep[ ] Oct (I Nov Dec ]Jul lLX]I (CxX11 Jul Aug Sep Occtt Nov Dec Nov Dec Hours 3 4 5 6 T 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 68 68 68 68 68 8 9 10 11 12 78 s8 78 78 78 78 78 78 78 78 78 78 68 68 68 AR aft ',/FO M 405-10 F ;ORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION(Florida Department of Business and Professional Regulation - Residential Perform ance Method Proj 'ct Name: NANCY & WALLY BURKE Stre LOT#841 VENTURE City, tate, Tip: ST. LUCIE COUNTY, FL, DD gh Location: FL, Fort Pierce 1. New onstruction or existing 2. Sirigl I family or multiple family 3. Num Ier of units, if multiple family 4. Num I r of Bedrooms 5. Is this a worst case? 6. Cond' oned floor area above grade (ft2) Condi `oned floor area below grade (ft2) 7. Windo (155.0 sgft) Description a. U- ctor. Sgl, U=0.46 SH C: SHGC=0.36 b. U-F ctor: N/A SH C: c. U-F ctor: N/A SH C: d. U-F ptor: N/A Area W ghted Average Overhang Depth: Area W ghted Average SHGC: 8. Floor T es (963.0 sqft.) a. Slab- n-Grade Edge Insulation b. N/A C. N/A Area: 0.161 New (From Plans) Single-family 1 2 No 963 0 Builder Name: Permit Office: Permit Number: Jurisdiction: 9. Wall Types (1549.3 sgft.) a. Concrete Block - Ext Insul, Exterior b. Frame - Wood, Adjacent c. N/A d. N/A 10. Ceiling Types (963.0 sgft.) a. Under Attic (Vented) b. N/A c. NIA 11 Ducts Area a. Sup: Attic, Ret: Attic, AH: Main 155.00 ft2 ft2 12. Cooling systems a. Central Unit fr 13. Heating systems ft2 a. Electric Strip Heat 2.000 ft. 0.360 14. Hot water systems Insulation Area a• Electric R=0.0 963.00 ftz R= b. Conservation features ftz R= None 15. Credits Total Proposed Modified Loads: 21.87 Total Standard Reference Loads: 27.60 I hereby ce'�' ify that the plans and specifications covered by this calcul tion are in compliance with the Florida Energy Code. PREPAR By DATE: y--1 I hereby ceq, ify that this building, as designed, is in compliance with the Floda Energy Colt. DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: Insulation Area R=4.1 1344.00 ff R=11.0 205.33 ft2 R= ft2 R= ft2 Insulation Area R=38.0 963.00 f? R= fF R= ft2 R fF 6 185 kBtu/hr Efficiency 24.2 SEERA6.00 kBhr/hr Efficiency 17.0 COPA.00 Cap: 40 gallons EF: 0.920 Pstat PASS 4/3/2014 7. PM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5