Loading...
HomeMy WebLinkAboutREVISIONOFFICE USE ONLY: DATE FILED: I -SCANNEJ PERMIT # I !Zt? *-d g 5 REVISION FEE: RECEIPT # 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: RT 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: _ BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): 4. OWNER/BUILDER INFORMATION: 5. NAME: ADDRESS: CITY: PHONE: NAME: ADDRESS: CITY: PHONE (DAY' SLCCC: 9/23/09 Revised 04/26/2010 K .-t-, ( '-� ) TE: ' FAX: STATE: ZIP: FAX: FAX 7T/_— 7 9'S 1- Hanson Regal/Spanish "S" II Roof Tile FL it 3505.3 . nailed to decking with (2) IOd ring shank nails over 90 lb, mop in over 19/32" COX plywood attached to trusses 12 per sheeting attachment diagram on roof plan SLOPE 6 O 12'-0" T.0.15 A.F.F. 12„ 10. H; 24' s � O.H. 5/8„ thick light textured stucco on typical concrete � O stucco banded block construction Smooth finished stucco band ��yU FRONT ELEVATION SCALE: 1/4". = 1'-0" Hanson Regal/Spanish "S" 11 Roof Tile FL 9 3505.3 nailed to decking with (2) IOd ring shank nails over 90 lb. mop in 12 over 19/32" COX plywood attached to trusses per sheeting attachment diagram on roof plan SLOPE L A.F.F. 12" x 12" concrete column 'block: -filled -with.-concrete and. (4) ,46 bars _...._..__.._. 24" vert. w/ stucco Finish and decorative stucco capital And base O.H: 5/8" thick light textured stucco on typical concrete block construction O i �f REAR ELEV,4710N ►vi PERMITTING INFORMATION (FORM 100) Florida Building Code Residential 2010 Edition and ASCE 1-10 for Wind Loading Building Design is: Enclosed Risk Categoryy II Wind Speed: 160 mph ultimate Mean Roof Height: I1'-10" Roof Pitch: 4:12 Internal Pressure CoCe`�`icient: ±0.18 Subjectability to damage from: Weathering: Negligible Termites: Very Heavy Width of .Roof End Zone: 5'-6" Wind Exposure Classification: C Adjustment factor for Exposure Height Using Allowable Stress Design and Load Combination per ASCE T-10 Section 2.4 DL+LL DL+0.6WL; O.6OL+0.6WL Ex Height Adj Factor: 1.21 x Load Combo Factor 0.6 = 0.126 applied below Components t Cladding Wind Pressure (NET) Roof Zone: 1. +21.9/-34.6 psf Roof Zone: 2. +21.9/-60.0 psf Roof Zone: 3. +21.9/-89.3 psf Components t Cladding Wall End Zone Width: 5'-6" Components t Cladding Wind Pressure (NET) Wall Zone: 4. +31,9/-41.1 psf Wall Zone: 5. +31.9/-50.1 psf Components t Cladding Wind Pressure (NET) on Garage Door: +31.9/-5C.1 psf Shear Walls Considered for Structure? Yes Continuous Load Path Provided? Yes Are Components an Cladding Deter Provided? Yes Minimum Soil Bearing Pressure:2,500 psi, Presumptive: X Bg Test: psi This Budding Shall Have the Following: APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER: E:1 = Roof Zone I Walls Zone 4 = Roof Zone 2 Walls Zone 5 END ZONE = Corner Zones RooF Zone 3 ' 2:12 ITCH Product Approval Submittal Affidavit Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows & Skylights 0 enin p Type;, NOA FL NUMBER Product Model # Manufacturer Glass Attachment method TEST Expiration at Maximum Design Pressure of Approved Tests 1, 11-1115.08 Sln H Single g Hung Series 110 Thermal Impact CGI Sentinel Type B Concrete: 1/4" dia. 7a cons w/ min. 1 1/2" penetration spaced per testing requirements stated' in NOA 9-22-15 + 80,0 PSF - 2; II-103LO4 Fixed Glass Series 130 . Thermal Impact CGI � Sentinel Type "Cl" Concrete: 1/4" Tapcons min. I I/2" ppenetration t stated in NOA spaced per testingng requirements 9-22-15 + 80.0 PSF - 3: 09-1028.10 PGT 6 Type A + �5.0 PSF - French .Door _ 5 Impact Series 110 5 SriePGT ImpactyP e i s is x p n wi p a on at b max from corners. Jambs: II" o.c. max from corners at 18" o.c. thereafter 2-24-15 4: 09-0826.10- Sliding Glass T e "A„ Head t Sill: 1/4" dia x 3" Tapcons 'with 1 1/2" penetration at 4" max from corners. Jambs: II" o.c. max from corners at 18" o.c. thereafter 2-17-15 ± 90.0 PSF 5 FLU 8248.9 Steel Overhead Garage Door 8100 Series Raised Panel ne Wa Dalton y Per Plans - I/2" x 6" sieve anchors at 10" o.c. + 46.O/-52 PSF 6. Product NOA FL / NUMBER Model # Manufacturer Attachment Method TEST Expiration Date- Maximum Design Pressure of Approved Tests Mullions Roof _. ,.,. FLU 3505.3over Regal/Spanish "S" Tile Hanson Roof Nailed to decking with (2) IOd ring shank nails over 90 lb. mop in 19/32" COX plgwood attached- _to trusses per sheeting_. - attachment diagram on roof plan Siding STUCCO ON BLOC14 5/8" Thick light textured stucco on typical Concrete block construction Soffit STUCCO ON LATH 1/2" thick stucco on 3/8" Hi -Rib lath attached to horizontal and vertical wood framing with nails or staples to provide no less than 1 3/4" penetration into horizontal wood framm and 3/4" penetration into vertical framm Hurricane Panels . 3. 08-06206 0.050 Aluminum Storm Shutters Eastern Metal Supply Inc. Provide I/4" dia. ELCO Male/Female "Panelmate" with min. 2" penetration and 1/4"-20 machine screw with nut at 6" o.c. for installation Section 48 9-1-13 + 63.0 PSF ALL Product Testing by: Miami -Dade County Building Code Compliance Office / Product Control DIVISion I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record ) P�"�s� ON ST. LUCIE COUNTY BUILDING DIVISION - REVIEWED FOR COM �ICE REVIEWE BY DATE PLANSANDPERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILT. BE MADE FILE COPY SCANNrrn 3V FILE COPY O v kn U O NCI O I Q N � � I I aj -v cv v I L a, �C'I Q10 Q �K Q Q.._ cv v �O �a Do cr1 N 0 OD OJ E w I I OQ W l �(VN �UNcvQJa- r r !�Q QQJ LLI r r a 03 (o E LL Q ~ LL I Q1 LL . L tQ W flo Sheet 1_ OF Comm ti 13-31