Loading...
HomeMy WebLinkAboutLETTER OF TRANSMITTAL6 92ECS Florida. LLC 2000 Avenue "P" Suite 3 LETTER QF T6 r L West Palm Beach, FL 33404�� i0 (561) 840-3667 [Phone] G }NM FILE (561) 840-3668 [Fax] ''3 Y C Dec mber 21, 2018 r Y4900 Seagrape Drive - CMT Coo' er Enterprises 4.0, LLC ECS Job # 25:3415 251 SW Regency Road Stu t. FL 34997 Permits: AT IIN: Mr. Stewart Cooper W are enclosing: ,l Field Reports XII For your use ;� As requested Field Report # 1 12/13/2018 Location: 4900 Seagrape Drive Ft. Pierce, FL 1. This rep art (and any attachments) shall not be reproduced except in full without prior written approval of ECS. 2. The info' ation in this report relates only to the activities performed on the report date. 3. Where propriate, this report includes statements as to compliance with applicable project drawings and specifications for the activities performed on this r port date. 4. Incompl ate or non -conforming work will be recorded for future resolution. 5. The results of samples and/or specimens obtained or prepared for subsequent laboratory testing will be presented in separate reports/documents. 1100.1 Transmittal Page 1/6 ECS Florida. LLC rJ- 2000 Avenue "P" Suite 3 West Palm Beach, FL 33404 (661) 840-3667 [Phone] (561) 840-3668 [Fax] :t 4900 Seagrape Drive - CMT on Ft. Pierce, FL Cooper Enterprises 4.0, LLC - Stewart Cooper Cooper Enterprises 4.0, LLC - Stewart Cooper FIELD REPORT Project No. 25:3415 Report No. 1 Day & Date Thursday 12/13/2018 Weather 820/ Sunny On -Site Time 2.00 Lab Time 0.00 Travel Time* 0.00 Total 2.00 Re Obs.Time 0.00 Charges* 20.00 Tolls/Parking* Mileage* Time of Arrival Departure -geable Items 1 -Nuclear Gauge Rental 01:30P 03:30P * Travel time and mileage will be billed in accordance with the contract. II Summary of Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted. The undersigned arrived on site, as requested, to test the compaction of soils for the building pad. Please see the attached sketch. Utilizing the Nuclear Test Method (ASTM D-6938) to check the compaction of soils; test results indicated that the compacted material, at the areas and elevations tested, met or exceeded the project requirements of 98% of the maximum dry density as obtained in our laboratory using the Modified Proctor Method (ASTM D-1557). Locations and elevations of all tests are based on stakeout provided by others. We cannot be responsible for structures located off of the observed engineered pad, misaligned utilities or stakeout errors causing uncontrolled fill to be placed in structural areas. An ECS representative will return for further testing upon request. The undersigned also picked up as requested a soil sample for proctor/LBR testing. The material was obtained from a stockpile west of the building pad. The soils were returned to the ECS laboratory for final testing. Please see attached photo. By Rashad A Smith 1800 Transmittal Page 2/6 v17.1.12 13 651495 ECS Florida, LLC 2000 Avenue"P" Suite 3 West Palm Beach, FL 33404 (561) 840-3667 [Phone] (561) 840-3668 [Fax] ,x P �oject 4900 Seagrape Drive - CMT Ell \�� J�i�;•��GENd ' •�'Y ��i � � e �htiag$,t� :oF 0 2018 ittA'rxee Fr:0R1O};'-��`Z'�� ON Ay 111 By Rashad A Smith FIELD REPORT Project No. 25:3415 Report No. 1 Day & Date Thursday 12/13/2018 le',PAK� Paul C Desentz Project Engineer 1800 Page 2 Transmittal Page 3/6 v17.1.12 13 651495 Page 1 Field Compaction Summary, ASTM D6938 Project No: 3415 Project Name: 4Q 0 Seagraoe Drive - CMT Date:12/13/2018 Client: Cooper Enterprises 4.0, LLC Test Method ASTM D6938 _LC Nuclear Gauge No.31761 Contractor: Cooper Enterprises 4.0, LLC Make Troxler Density Std 2001 Model 3440 Moisture Std 1 778 Technician: Rashad A Smith Ser. No. 31761 Sample io. Description Proctor Method Uncorrected Max. Densi6 Uncorrected Opt. MC 'ID4S1 Brown fine to medium slightly silty sand trace shellrock Modified Proctor Method (ASTM D-1557) 116.70 10.40 and organics Corrected Corrected Wet Dry Moisture Percent Probe Maximum Optimum Test I Test Depth Station / Lift / ova Dry Moisture Density Density Content Comp. P / F Comments No. Lot No. Mode (in.) Location Elev Sample No. Oversize Density Content (pct) (p ) (off) (%) 1 341 III DT 12 Building Pad 1st D4S1 0.00 116.70 10.40 129.6 117.2 10.5 100.4 P 2 341S DT 12 Building Pad 1st D4S1 0.00 116.70 10.40 126.8 112.8 12.4 96.7 P 3 341 II DT 12 Building Pad 1st I D4S1 1 0.00 1 116.70 10.40 130.1 113.6 14.5 97.3 P 4 341 DT 12 Building Pad 1st D4S1 1 0.00 116.70 1 10.40 126.2 112.2 12.5 96.1 P Test Mode: DT = Direct Transmission BS = Back Scatter WCA5564 Transmittal Page 4/6 F :49:0( Seagrape Drive - 25:3415 Rashad Smith 12/13/2018 F M: a. xT ll /r.ar rx t f Transmittal Page 5/6 'ex ol W, 91 _-km 1:1 .1- W­ A U _Oc 10� W-,