Loading...
HomeMy WebLinkAboutNFRC REPORT8GANNED BY NFRC Report - iLuds C.00 �9 Quote # 5319084 PO Number: Job Name: Seagrape Lot 8 Job Address: Line # ^Item Description Quantity Location 0001 SH (1.00) 36. GB'2V1H/2VlH,DBL,SWEEP,1816K-INSTALLED,CMI 500 VINYL SINGLE 62.X.,25,STD,5/8" HUNG 5500 Ordered: FL,W,EQUAL,7/8 LIG,CL,ES Max,9/�6" 2.00 Q1�lumber: E DINING ROOM H1L !! Certification Type: MIAMI NOA Selection: 17-0630.05 1 Frame Type:.625FLANGE Vent Configuration: EQUAL _ I _ r " Window Style: STD Size Code: 25.0000 Size Selection: COMMODITY Size Ref: ACTUAL Actual Size: 36 X 62 Rough Masonry: 37 3/4 X 63 1 Wood Frame Opening: 36 1/4 X 62 1/4 Egress Opening: 31 3/4 X 26 3/8 (5.8087 SQFT) {( Frame Color: W -White Balance Type: CONSTANT t I Glass Family: LI - Laminated Insulating Interlayer Type: PVB090 _ Glass Makeup: LIA207AA5 Glass: 7/8" LIG (1/8 L N - 7/16 AIR -5/16 AN/AN Does unit need to meet Turtle Code: NO Glass Color. CL -CLEAR 1 j 0 Low E: ENERGY SHIELD MAX Privacy Glass. NONE -NONE Grid Style: STD Summary Top: 3A2D LITES (2V1 H BARS) Reinf. Upgrade: NONE -None Argon Gas: NONE Grid Type. GBGF0563 - 9/16 Flat GridBETWEEN Grid Location: UNIT Summary Bottom: 3A2D LITES (2V1 H BARS) Screen Type: 1816K - 1816 Charcoal Screen Frame Type: ROLLFORM WOCD: N Vent Latch: N Lock Type: SWEEP - Sweep Latch Upgrade Hardware Finish: N Comfort Lift: Y Lift Rail: N Lock Quantity: 2.0000 Anchor Group: C.SH5500 Boxing Options: N -None Acc Glass Breakage: N Decralite: N Vent Ht: 30.6430 CAR#: 17-0630.05 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL-239 EnergyStar. 1.0000 CondensationResistance: 55.0000 UF: 0.3200 SolarHeatGainCoeff: 0.1900 VT: 0.4300 VTCOG: 0.6300 { 0002 M L MULL BARS Ordered: E DINING ROOM (22.00) 1,621,W,.625FLANGE,SERIES 5500,MULL/CVR/CLPS,2 1.00 Product Family Series: 5500.0000 Certification Type: MIAMI NOA Selection: 17-0630.01 Part Selection: MULL/CVR/CLPS - Mull, Ext/Int Frame Type:.625FLANGE Mull Bar Type: 1.25X3.25X.100 Mull Clip Qty: 2.0000 Mull Clip Type: T-C.LIP/T-CLIP Size Selection: CUSTOM Length: 62.0000 Frame Color: W -White Boxing Options: N - None 0003T36 (4.00) 5004 VINYL SINGLE HUNG 5500 Ordered:x K 62.X.,25,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,9/16" 1.00 B BED #2 HN 2V1H/2V1H,DBL,SWEEP,1816K-INSTALLED,CMFRTLFT 5L _ J FILE COPY Print Date 7/16/2018 Page 1 of 6 Certification Type: MIAMI NOA Selection: 16-0714.03 Frame Type:.625FLANGE Vent Configuration: EQUAL 1 r — _ Window Style: STD Size Selection: COMMODITY f I Size Code: 25.0000 Size Ref: ACTUAL ( 1 Actual Size: 36 X 62 Rough Masonry: 37 3/4 X 63 Wood Frame: 36 1/4 X 62 1/4 Egress: 31 3/4 X 26 3/8 (5.808 SQFT) Frame Color. White Does unit need to meet Turtle Code: NO +. 1 Lj � , Glass Family: Laminated Insulating Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN =i� Intedayer Type: PVB090 Argon Gas: NONE �B Glass Color: CLEAR Low E: ENERGY SHIELD MAX �1 Privacy Glass: NONE Grid Type: 9/16" Flat GridBETWEEN GLASS i { 4"" Grid Style: STD Grid Location: UNIT I!% Summary Top: 3A2D LITES (2V1H BARS) Summary Bottom: 3A213 LITES (2V1H BARS) Screen Type: 1816 Charcoal Screen Frame Type: ROLLFORM }} o- Anchor Group: C.SH5500 Boxing Options: None Vent Latch: N Comfort Lift: Y Lift Rail: N WOCD: N Lock Type: Sweep Latch Decralite: N Reinf. Upgrade: None Acc Glass Breakage: N Upgrade Hardware Finish: N Vent Ht: 30.6430 CAR#: 16-0714.03 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL-239 EnergyStar: 1.0000 CondensationResistance: 55.0000 UF: 0.3200 SolarHeatGainCoeff: 0.1900 VT: 0.4300 VTCOG: 0.6300 2. 0004 SH 500 VINYL SINGLE HUNG 5500 A BED #2 =Ordorel: (5.00) 36.X37.375X.,23,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,NO GR,,DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL Certification Type: MIAMI NOA Selection: 16-0714.03 Frame Type:.625FLANGE Vent Configuration: EQUAL Window Style: STD Size Selection: COMMODITY T� Size Code: 23.0000 Size Ref: ACTUAL 1 Actual Size: 36 X 37 3/8 Rough Masonry: 37 3/4 X 38 318 Wood Frame: 36 1/4 X 37 5/8 Egress: 31 3/4 X 14 0/1 (3.094 SQFT) -- — xm Frame Color: White Does unit need to meet Turtle Code: NO Glass Family: Laminated Insulating Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN InterlayerType: PVB090 Argon Gas: NONE Glass Color: CLEAR Low E: ENERGY SHIELD MAX Privacy Glass: NONE Grid Type: NO Grid 38 x Screen Type: 1816 Charcoal Screen Frame Type: ROLLFORM Anchor Group: C.SH5500 Boxing Options: None Vent Latch: N Comfort Lift: Y Lift Rail: N WOCD: N Lock Type: Sweep Latch Reinf. Upgrade: None Acc Glass Breakage: N Upgrade Hardware Finish: N Vent Ht: 18.3300 CAR#: 16-0714.03 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL-239 EnergyStar: 1.0000 CondensationResistance: 55.0000 UF: 0.3200 SolarHeatGainCoeff: 0.2200 VT: 0.4800 VTCOG: 0.6300 0005 HR 510 VINYL HORIZONTAL ROLLER 5510 Ordered: C BATH #2 (6.00) /8" FL, 8 LIG,CL,ES Max,NO GRID,XO,EQUAL,1816K- 1.00 NSALL EP Print Date 7/16/2018 Page 2 of 6 Certification Type: MIAMI �! NOA Selection: 16-0714.17 Frame Type:.625FLANGE Unit Configuration: XO Vent Configuration: EQUAL Size Selection: CUSTOM ({ Size Ref: ACTUAL Width: 35.0000 Height: 17.0000 Actual Size: 35 X 17 Rough Masonry Opening: 36 3/4 X 18 Wood Frame Opening: 35 1/4 X 17 1/4 r Egress Opening: 12 9/16 X 12 1/16 SQFT 1.0493 Frame Color: White Does unit need to meet Turtle Code: NO Glass Family: Laminated Insulating Glass Type: 1/8" - 5/16" Interlayer Type: PVB090 Argon Gas: NONE Glass Makeup: LIA207AA5 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Glass Color: CLEAR Low E: ENERGY SHIELD MAX Privacy Glass: NONE Grid Type: NO Grid Screen Type: 1816 Charcoal Screen Frame Type: ROLLFORM Anchor Group: C.HR5510 Boxing Options: None Vent Latch: N Type Lock: Sweep Latch Window Opening Control Device: N Reinf. Upgrade: None Acc Glass Breakage: N Upgrade Hardware Finish: N CAR#: 16-0714.17 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL-242 EnergyStar: 1.0000 CondensationResistance: 57.0000 UF: 0.3200 SolarHeatGainCoeff: 0.2100 VT: 0.4700 VTCOG: 0.6300 y 0006 SH 500 VINYL SINGLE HUNG 5500 rdered: A BED #3 (7.00) 36. 37.375X.,23,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,NO .00 10, GR ,DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL Certification Type: MIAMI NOA Selection: 16-0714.03 Frame Type:.625FLANGE Vent Configuration: EQUAL Window Style: STD Size Selection: COMMODITY Size Code: 23.0000 Size Ref: ACTUAL Actual Size: 36 X 37 3/8 Rough Masonry: 37 3/4 X 38 318 Wood Frame: 36 1/4 X 37 5/8 Egress: 31 3/4 X 14 0/1 (3.094 SQFT) Frame Color: White Does unit need to meet Turtle Code: NO s% BE Glass Family: Laminated Insulating Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Interlayer Type: PVB090 Argon Gas: NONE -J Glass Color: CLEAR Low E: ENERGY SHIELD MAX 3s^ Privacy Glass: NONE Grid Type: NO Grid Screen Type: 1816 Charcoal Screen Frame Type: ROLLFORM Anchor Group: C.SH5500 Boxing Options: None Vent Latch: N Comfort Lift: Y Lift Rail: N WOCD: N I Lock Type: Sweep Latch Reinf. Upgrade: None Acc Glass Breakage: N Upgrade Hardware Finish: N Vent Ht: 18.3300 CAR#: 16-0714.03 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL-239 CondensationResistance: 55.0000 EnergyStar: 1.0000 UF: 0.3200 SolarHeatGainCoeff: 0.2200 VT: 0.4800 VTCOG: 0.6300 0007 SH51,600 (8.00) 36.62.X.,25,STD,5/8" VINYL SINGLE HUNG 5500 Ordered: B BED #3 FL,W,EQUAL,7/8 LIG,CL,ES Max,NO 1^00 GRI),DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL Print Date 7/16/2018 Page 3 of 6 Certification Type: MIAMI Frame Type:.625FLANGE Window Style: STD — -- Size Code: 25.0000 Actual Size: 36 X 62 I Wood Frame: 36 1/4 X 62 1/4 I Frame Color: White Glass Family: Laminated Insulating ` "72 InterlayerType: PVB090 ( a Glass Color: CLEAR i{ Privacy Glass: NONE " l Screen Type: 1816 Charcoal - Anchor Group: C.SH5500 «; '�' Vent Latch: N Lift Rail: N Lock Type: SweepLatch ""�- Acc Glass Breakage: N Vent Ht: 30.6430 PositiveDesignPressure: 50.0000 PANumber: FL-239 CondensationResistance: 55.0000 SolarHeatGainCoeff: 0.2200 VTCOG: 0.6300 6008 SGD5570 VINYL SGD SERIES 5570 Ordered: (23.00) 105�Ih875X80.,9068,BYPASS,3P3T,XXX,REV,2.5,W,11/16 1.00 TLI I,,CLEAR,ES Max,NO GRID,BS,1816K,ALL 1 Send Unit: COMPLETE - NOA Selection: 17-0420.06 Pnlffrk: 3 Panel / 3 Track Panel Stack: REV Size Code: 9068.0000 Calc Track Length: 105.1880 Glass Makeup: LIT307AS7 Glass Family: LI - Laminated Insulating Glass Color: CL - CLEAR Argon Gas: NONE InteriayerType: PVB090 Sill Riser Height: 2.5000 Screen Type: 1816K - 1816 Charcoal Handle Type: RAISED/RAISED Lock/Handle Location: STD Key Lock: N Panel Opr Rlr. STEELTM Steel Tandem Anchor Group: C.SGD5570 Boxing Options: N -None Acc Glass Breakage: N PositiveDesignPressure: 38.7000 PANumber: FL-251 CondensationResistance: 55.0000 SolarHeatGainCoeff: 0.2000 VTCOG: 0.6200 NOA Selection: 16-0714.03 Vent Configuration: EQUAL Size Selection: COMMODITY Size Ref: ACTUAL Rough Masonry: 37 3/4 X 63 Egress: 31 3/4 X 26 3/8 (5.808 SQFT) Does unit need to meet Turtle Code: NO Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Argon Gas: NONE Low E: ENERGY SHIELD MAX Grid Type: NO Grid Screen Frame Type: ROLLFORM Boxing Options: None Comfort Lift: Y WOCD: N Reinf. Upgrade: None Upgrade Hardware Finish: N CAR#: 16-0714.03 NegativeDesignPressure: 50.0000 EnergyStar: 1.0000 UF: 0.3200 VT: 0.4800 Certification Type: MIAMI Door Configuration: BYPASS Panel Configuration: XXX Size Selection: NOMINAL Actual Size: 105 3/16 X 80 Frame Color: W -White Glass: 1-1/16" LIG (3/16 TMP-7/16AIR-7/16 AN/HS Does unit need to meet Turtle Code: NO Low E: ENERGY SHIELD MAX Privacy Glass: NONE -NONE Grid Type: NONE - NO Grid Screen Panel Type: BOX Screen Rail Qty: 1-BOX Handle Color: W -White Secondary Lock Type: NONE Keyed Alike: N Screen Rlr. STEEL Steel Send frm w/snap on Nail Fin: N Max Energy/Composite Reinf: N CAR#: 17-0420.06 NegativeDesignPressure: 60.0000 EnergyStar: NONE UF: 0.3500 VT: 0.4200 1. (16.00) `X37.37 X.,3 ,S D,5/8- FL,W,CMFRT LFTHis ,E ,DL Max,NO �o GR 4„ Ordered: D KITCHEN Print Date 7/16/2018 Page 4 of 6 i Certification Type: MIAMI NOA Selection: 16-0714.03 �• i--- a � Frame Type:.625FLANGE Vent Configuration: EQUAL Window Style: STD Size Selection: COMMODITY Size Code: 33.0000 Size Ref: ACTUAL = - - Actual Size: 52 1/8 X 37 3/8 Rough Masonry: 53 7/8 X 38 3/8 Wood Frame: 52 3/8 X 37 5/8 Egress: 47 7/8 X 14 0/1 (4.665 SQFT) Frame Color: White Does unit need to meet Turtle Code: NO Glass Family: Laminated Insulating Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Interlayer Type: PVB090 Argon Gas: NONE Glass Color: CLEAR Low E: ENERGY SHIELD MAX Privacy Glass: NONE Grid Type: NO Grid Screen Type: 1816 Charcoal Screen Frame Type: ROLLFORM Anchor Group: C.SH5500 Boxing Options: None Vent Latch: N Comfort Lift: Y Lift Rail: N WOCD: N Lock Type: Sweep Latch Reinf. Upgrade: None Acc Glass Breakage: N Upgrade Hardware Finish: N Vent Ht: 18.3300 CARM 16-0714.03 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL-239 EnergyStar: 1.0000 CondensationResistance: 55.0000 UF: 0.3200 SolarHeatGainCoeff: 0.2200 VT: 0.4800 VTCOG: 0.6300 0010 SH 500 VINYL SINGLE HUNG 5500 Ordered: E MASTER BED (17 00) 36. 62.X.,25,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,NO 1.00 ' GR,,D,DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL Certification Type: MIAMI NOA Selection: 17-0630.05 i Frame Type:.625FLANGE Vent Configuration: EQUAL _- a Window Style: STD Size Selection: COMMODITY Size Code: 25.0000 Size Ref: ACTUAL ij} Actual Size: 36 X 62 Rough Masonry: 37 3/4 X 63 Wood Frame Opening: 36 114 X 62 1/4 Egress Opening: 31 3/4 X 26 3/8 (5.8087 SQFT) { Frame Color: W -White Balance Type: CONSTANT Glass Family: LI - Laminated Insulating Interlayer Type: PVB090 Glass Makeup: LIA207AA5 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN �N r( ii Does unit need to meet Turtle Code: NO Glass Color: CL - CLEAR ill Low E: ENERGY SHIELD MAX Privacy Glass: NONE - NONE Argon Gas: NONE Grid Type: NONE - NO Grid j{ Reinf. Upgrade: NONE - None Screen Type: 1816K - 1816 Charcoal Screen Frame Type: ROLLFORM Vent Latch: N WOCD: N Lock Type: SWEEP - Sweep Latch Upgrade Hardware Finish: N Comfort Lift: Y Lift Rail: N Lock Quantity: 2.0000 Anchor Group: C.SH5500 Boxing Options: N - None Acc Glass Breakage: N Vent Ht: 30.6430 CAR#: 17-0630.05 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL-239 EnergyStar: 1.0000 CondensationResistance: 55.0000 UF: 0.3200 SolarHeatGainCoeff: 0.2200 VT: 0.4800 VTCOG: 0.6300 ,- _ 0011 MU1 L MULL BARS Ordered: E MASTER BED (18.00) Product Family Series: 5500.0000 Certification Type: MIAMI NOA Selection: 16-0218.03 Part Selection: MULUCVR/CLPS Frame Type:.625FLANGE Mull Bar Type: 1.25X3.25X.100 Mull Clip Qty: 2.0000 Mull Clip Type: T-CLIP/T-CLIP Size Selection: CUSTOM Length: 62.0000 Frame Color: W Packaging Options: N { 0012 PW 520 PW5520 VINYL PICTURE WINDOW Ordered: F MASTER BED (20.00) 83. 5.,5/8" FL,W,7/8 LIG,CL,ES Max,OUTSIDE GLZ,NO GRID 1.00 Print Date 7/16/2018 I Page 5 of 6 Certification Type: MIAMI NOA Selection: 16-0629.12 `s Frame Type:.625FLANGE Size Selection: CUSTOM ==> a. '• Size Ref: ACTUAL Width: 83.0000 Height: 15.0000 Actual Size: 83 X 15 ! i Rough Masonry Opening: 84 3/4 X 16 Wood Frame Opening: 83 1/4 X 15 114 j Frame Color: White Does unit need to meet Turtle Code: NO j Glass Family: Laminated Insulating Interlayer Type: PVB090 Argon Gas: NONE Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Glass Color: CLEAR Low E: ENERGY SHIELD MAX i Privacy Glass: NONE Grid Type: NO Grid Boxing Options: None Acc Glass Breakage: N CAR#: 16-0629.12 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL 243 EnergyStar: 123.0000 CondensationResistance: 58.0000 UF: 0.2800 SolarHeatGainCoeff: 0.2300 VT: 0.5300 VTCOG: 0.6300 0013 SH�`500 VINYL SINGLE HUNG 5500 Ordered: G MASTER BATH (21.00) 52. [25X49.625X.,34,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,NO 1.00 GR ,DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL Certification Type: MIAMI NOA Selection: 16-0714.03 _ Frame Type:.625FLANGE Vent Configuration: EQUAL Window Style: STD Size Selection: COMMODITY Size Code: 34.0000 Size Ref: ACTUAL i Actual Size: 52 1/8 X 49 5/8 Rough Masonry: 53 7/8 X 50 5/8 # _ Wood Frame: 52 3/8 X 49 7/8 Egress: 47 7/8 X 20 1/8 (6.701 SQFT) Frame Color: White Does unit need to meet Turtle Code: NO p 14 ( r r Glass Family: Laminated Insulating Interlayer Type: PVB090 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Argon Gas: NONE ti iW Glass Color: CLEAR Low E: ENERGY SHIELD MAX Privacy Glass: NONE Grid Type: NO Grid Screen Type: 1816 Charcoal Screen Frame Type: ROLLFORM Anchor Group: C.SH5500 Boxing Options: None I Vent Latch: N Comfort Lift: Y Lift Rail: N WOCD: N Lock Type: Sweep Latch Reinf. Upgrade: None Acc Glass Breakage: N Upgrade Hardware Finish: N Vent Ht: 24.4550 CAR#: 16-0714.03 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL-239 EnergyStar: 1.0000 CondensationResistance: 55.0000 UF: 0.3200 SolarHeatGainCoeff: 0.2200 VT: 0.4800 VTCOG: 0.6300 Print Date 7/16/2018 Page 6 of 6