Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL EXTERIOR DOORS7/1 Florida Building Code Online BCIS Home I Log In ial Regulation SCANNED User Registration F Hot Topics i Submit Surcharge I Stj &Mj Facts I Publications t Contact Us E BCIS Site Map F Links Search y a " Product Approval M USER: Public User Product Approval Menu > Product or Application Search > gpplication List > Application Detail FL # FL7640-R8 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Therma Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton, OH 43517 (419) 298-1740 rickw@rwbldgconsultants.com Authorized Signature Rick Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan ]. King, P.E. Cl Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards FL7640 R8 COI (b) Certificate of Independence.pdf Standard ANSI/AAMA/NWWDA 101/I.S.2/A440 ASTM E1886 ASTM E1996 ASTM E330 TAS 201, 202, 203 Certified By Florida ofe al Engineer or Architect FL7640 ui (b) quivale OftafROX Sections from the Code UFY ig.org/pr/pr app_ d.aspx?param--wGEVXQwtDgvKp/o2bCDGtDPk%2b6VPfFie6OgmuUAxYGc2%2bA`/o3d Year 2005 2002 2002 2002 1994 1/4 7/16/201 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 10/18/2017 Date Validated 10/18/2017 Date Pending FBC Approval 10/22/2017 Date Approved 12/12/2017 Summary of Products FL # IModel, Number or Name Description 7640.1 a. "FiberClassic", "SmoothStar", 6'8 "Impact" Glazed Fiberglass Single Door - (X) Inswing or "ClassicCraft" or "ClassicCraft Rustic" Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL7640 R8 II (2) Inst 7640.1.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7640.1 for Design Pressure Ratings by FL7640 R8 AE (b) Eval 7640.1.pdf specific Model and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. (For FiberClassic and SmoothStar doors, this product approval requires the use of "Y part numbers for these doors, which have been stained or painted within six months of installation.) 7640.2 b. "FiberClassic", "SmoothStar", 6'8 "Impact" Glazed Fiberglass Single Door with Sidelite - (OX "ClassicCraft" or "ClassicCraft Rustic" or XO) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL7640 R8 II (b) Inst 7640.2.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7640.2 for Design Pressure Ratings by FL7640 R8 AE (b) Eva] 7640.2.pdf specific Model and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. (For FiberClassic and SmoothStar doors and sidelites, this product approval requires the use of "I" part numbers for these doors and sidelites, which have been stained or painted within six months of installation.) 7640.3 c. "FiberClassic", "SmoothStar", "ClassicCraft" or "ClassicCraft Rustic" 6'8 "Impact" Glazed Fiberglass Single Door with Sidelites - (OXO) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL7640 R8 II (b) Inst 7640.3.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7640.3 for Design Pressure Ratings by FL7640 R8 AE (b) Eval 7640.3.pdf specific Model and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. (For FiberClassic and SmoothStar doors and sidelites, this product approval requires the use of "]" part numbers for these doors and sidelites, which have been stained or painted within six months of installation.) 7640.4 d. "FiberClassic", "SmoothStar", "ClassicCraft" or "ClassicCraft Rustic" 6'8 "Impact" Glazed Fiberglass Double Door - (XX) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL7640 R8 II (b) Inst 7640.4.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7640.4 for Design Pressure Ratings by FL7640 R8 AE (b) Eval 7640.4.pjf specific Model and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. (For FiberClassic and SmoothStar doors, this product approval requires the use of "]" part numbers for these doors, which have been stained or painted within six months of installation.) 7640.5 e. "FiberClassic", "SmoothStar", 6'8 "Impact" Glazed Fiberglass Double Door with Sidelites - "ClassicCraft" or "ClassicCraft Rustic" (OXXO) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL7640 R8 II (b) Inst 7640.5.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes %3d 2/4 THERMAITRU @ THEPZMA TRU DOORS 1 1 6 INDUSTRIAL DR., EDGERTON, OH 4351 7 "SMOOTH STAR"; "FIBER CLASSIC", "CLASSIC CRAFT" & "CLASSIC CRAFT RUSTIC" GLAZED FIBERGLASS DOOR INSWING / OUTSWING 'IMPACT" GENERAL NOTES 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "Wand includes Wind Zone 4 as defined in ASTM El996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 4, For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS DESCRIPTION Typical elevations, design pressures & general notes Smooth Stardoor panel & glazing detals Fiber Classic door panel & glazing details T Classic Craft/Classic Craft Rustic door panel & glazing details Horizontal cross sections Vertical cross sections Buck and frame anchoring-2Xbuckmasonryconstruction Frame anchoring - iX buck masonry construction 9 1 Bill of Materials & Components �Z•� W 37.75'MA)L V: a N't y Z FRAME WIDTH 36.00" MAX. ��i�� •'• PANEL WIDTH w g o� N m "SMOOTH STAR", "FIBER CLASSIC" "CLASSIC CRAFT" & "CLASSIC CRAFT RUSTIC" a 0 U SWING ':_ a OVERALL FRAME DIMENSION OVERALL `= DIMENSfON DESIGN PRESSURE POSITIVE ,NEGATIVE': INSWING 37.76" x 82.0W 21.00" x 63.25" +47.0 -53.0 OUTSWING 37.75" x 80.62" 21.00" x 63,25" +50.0 -50.0 N 0, U1 o� S 01 �gR Z0Mm a lV •• O Z OZ 9mm 560 m n- a sc": N.T.S. DWG. e+: AL CHL Ff. LFS DRAWING NO.: FL-7640.1 PERMANENT\A - Florida Product Appnmis\FL-7640\C - Drawings\FL-7610 (2017)\FL-764D.1.3.dwg, 2.1 0.814" 0 N <T 3 � g Y 't:, g°o Cc):; s M 5 m S z -1 N C 5 z- �_ mGT;- � O a p 0 z O A � m y O) 00 m < b Iri ba a s pp O --r T CD 7 01 0 tnAu N O C. N c m W Ir a I+ D CL vo ' N N D Z r) So'I O O " how Mo 5->k ys;m Dy� lil. -> wZ Ao �n vY:, Z O SD Z CT m v o z m O M f� Kd I No. 43409 October 17, 2017 PRODUCT: Documents Prepared ey: �,� THERMA_TRU GLAZED FIBERGLASS DOOR Lyndon F. Schmidt P.E. No. 43409 �i�i4S •........••'••d`� ro 3 10 17 17 UPDATE TO 6TH ID . 2017 FBC JK 4 y -' 2 1 29 15 UPDATE TO 5TH ED. 2014 F13C LFS PART OR ASSEMBLY: BUILDING CONSULTANTS. INC. O L7 p 1 6 11 12 UPDATE TO 2010 FBC JK P.O. Box 230. Volrldo, FL 33595 co NO DATE BY SMOOTH STAR DOOR PANEL k GLAZING DETAILS phone No: 813.659.9197 !I REVISIONS FBPE C.A. No. 9813 ® 2D09 R.W. BUILDING CDNHULTANTH INC. Tru P8V4ANENT\A - Radda PmdUd Approvals\FL-7640\C - DravvIngs\VL-764D (2D17)\FL-7640.1-3.dwq, 3.1 632Y MAX. D.1-0. 0.836' Cr 1:2 0 0 F- M 0 010 QN 0 o 0 0 0 EMIM--11 1.541 try en a —z M M m 050 M M a . ...... m 0 b. 0 215 OL CD 0 > 06 0 O oz, To az 2!:Oz- - X r. 5�. O� 5: w 50 5: Cq -z ;C `C -9 IR -> > z P z Z 0 m m DO m m 0 rp (R)i en 0 ;0 4., M ..... 70 0 ca J* No.43409 October 17, 2017 J A PRODUCT. Document. Prepared BY.I,W Lyndon F. THERMA—TRU GLAZED FIBERGLASS DOOR Schmidt ftq• . ON P.E. No. 44mg R� 7AFAL 0....•...... 0) UPDATE TO 6TH ED. (2017) FBC JK UPDATE TO STH ED. (2074) FBC LFS PART OR ASSEMBLY: X(W BUILDING CONSULTANTS,INC. Da MO. UPDATE TO 2010 FBC - JK _�,y .1 FIBER CLASSIC 00 OR PANEL & GLAZING DETAILS P.O. Box 230, VoIrIca. FL 33595 9 phone No.: 813.65 .9197 REVISIONS FBPE CA No 813 9 00009 R.W. BuiLosmo CCNOULTAMT INC. Tm PERMANENT\A - Florida Product Appmvats\FL-7640\C - Drawings\FL-7690 (2017)IFL-7640.1-3.dw0, 4.1 I i N O A T11 000 _ •4 _ ^I ��m in L cXi -►j 0.957' --{ 0.957 r i mayy.. i?•�P'`v W 63241MAX D.L.O. 4 010 U �IT, 0 Z 1 N C p A >zs AG1� f O A O Crrf � D H N A m m ^�1�1�^�! 61 V/W z yZ �y r > m D A r Z m m m ® rn 00 v � o 3 UPDATE TO MED. 2017 FBC JK M10117 5TH ED. 2014 FBC LFS 1 2 UPDATE TO 2010 FHC JK NO DATE BY �W A O Z 70 THERMA-TRU GLAZED FIBERGLASS DOOR CLASSIC CRAFT/CL CRAFT DOOR PANEL & GLAZING �. F•SCHIyj �,� `�.�� v,.•� ucaisF• . J� �. No.43409• ! G *9 * :* October 17, 2017 % L It cemorMe Prep—d ey:,, tdon F. Schmidt ��j'C�••F:��'' d ���` No. 43409 BUILDING CONSULTANTS, INC. P.O. Box 230, Voirico. FL 33595 Phone No.: 813.659.9197 FBPE CA No. 9813 9 R.W. BUILDING CONSULTANTS INC. Tru PERMENT\A - Farlda Product AppmvalsWL-76401C - DrawingskFL-7640 (2017)%FL-7640.1.3.dwg, 5.1 • ;' m 0 iZ7 7 a - OF Z m 9 � _ 0 eL-J e e a I m 20 A ° ? 41 / No.43409 t _ October 17, 2017 •y PRODUCT: THERMA—TRU DoeumentII Prepared Br.' Lyndon F. Schmidt '�i/'•.OFt{D/:'\���� ' ` GLAZED FIBERGLASS DOOR P•E. No. 43409 /��_//���111/S�oj; �C " ' o Z N 3 17 17 �QA UPDATE TO BTFI ED. 2017 FBC JK 2 9 15 UPDATE TO STH ED. 2014 FBC LF'S PART OR ASSEMBLY: C(�/ BUILDING CONSULTANTS, INC. ��/�/ in 1 1 12 UPDATE TO2010 FBC JK co NO TE HORIZONTAL CROSS SECTION P•O. Box 230. Valrico, FL 33595 Phone No.: 813.659.9197 REVISIONS FBPE CA No. 9813 eu1LDING CONSULTANTS INC. PERNANENT\A - Flodda Product Approvals\FL-7640\C - Orawings\R-7640 (2017)\FL-7640,1-3.dwg, 6.1 1-I M MIN. EMB. (M.) m m 22 O A 1-1M MIN. EMB. (TYP.) Z o O A O o. I W m A O 30 1-1/4 MIN. EMB. (TYP.) 1-1/4" MIN. EMB. (TYP.) \LF,SCHM/ i����i �!•'VOFNl4F'O�' k/ No.43409 ' October 17, 2017 .1 C Q PRODUCT: 7T{ER(}A—TR(J ODaumente Prepamd eY: ' Lyndon F. Schmidt q,, GLAZED FIBERGLASS DOOR P.E. No. 43409 �i��ur71 //111�%��.1\\�\ w N 3 10 17 17 UPDATE TO 6TH ED. 2017 FBC JK 1—n y -' 2 7129115 UPDATE TO 5TH ED. 2014 FBC LFS PART OR ASSEMBLY: �1 BUILDING CONSULTANTS, INC. Ito O I" y r v7 0 1 NO 6 11 12 DATE UPDATE TO 2010 FBC JK BY d l�� P.O. Box 230. VDlri, FL 33595 ro REVISIONS CROSSRSEC17ONS Phone No.: 813.659.9197 FBPE C.A. No. 9813 BUILDING CONeNLTANT9 INC. ,Cients\Themm Tru PERMANENiV1- Rodda Pmduct Approvals\FL-7640\C - Drawings\FL-764D (2017)\FL-7640.1-3.dwg, 7.1 m to -- FF a r�`C]Zoo Z ,n ice;., Z?: a 3 0 n 0'n": n.m� X c: two > > > D Inc <3a a a pomoRO ':in.,x�. m O 6518 a. Z Er Ec q 0 5r E y [•rrr:�; m' i m 4 m c a pt Om a m D- .'` Z a. n . y3. a7 OR. x m9'Z 0 a?qn a man (D o wV t7Yi,^q � a w. v. ' �o n o cd]m 3' a ,o^ si�y>n p0q S m - ae>a.A m S L. n n ] m n >• 3n n II 2 I a Z 0 19" MAX. 4" O.C. (TYP.) Fn my 3 29.2T TYP" HINGE I -' 11.25' TO HINGE 0D Z Z c 17) j 3 a a y m i n F �n p o = 0 O a� n J 13.75' MAX. I b„ p O.C. (iYP.) W 15X Fes- 39.33' a N N `��`` vim• 13��'O�''�i ' V / Z No.43409 II _ October 17, 2017 h I� I� io it Z N $ r, ro co PRODUCT: THERMA—TRU GLAZED FIBERGLASS DOOR Document. Prepared Ebr.�Wt Lyndon F. Schmidt ��� P.E. No. 43409/O """���� m �!!!l 11110 %� /� BUILDING CONSULTANTS, INC. J l� P.O. Box 230, Valrleo, FL 33595 Phone No.: 813.659.9197 FBPE CA No. 9813 3 10 17 17 UPDATE TO 6TH ED. 2017 FBC JK 2 1 29 15 UPDATE TO 5TH ED. 2014 FBC LFS PART OR ASSEMBLY: BUCK &FRAME ANCHORING 2X BUCK MASONRY CONSTRUCTION 1 6 tt 12 UPDATE TO 2010 FBC JK NO DATE BY REVISIONS 2 09 R.W. BUILC INa CCNBULTANT9 INC. ,a a r--r6" MASONRY OPENING TYP. HEAD & JAMBS FRAME In ui _T N9z 5t IX BUCK F '20 TYP. SILL % HINGEJAMB FRAME ANCHORING Masonry IX buck construction CONCRETEANCHOR NOTES., 1. Concrete anchor locations at the comers maybe adjusted to maintain the min. edge distance to mortarjoints. ; L 2. Concrete anchor locations noted os"MAX. ON CENTER"must be adjusted to maintain the min. edge distance to mortarjoints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: AJNP.00#,. ANC-00 MIN..,...C..L..Z. ARAV CLEARANCE 1YPE SIZE ENT',' . .....MASONRY..... ...... .... ... ..... ITIN TAPCON 1/4" 1-1/lr ITW PCON 3/16- 1-1/4n I w VVUUU atKrYV HV31 ALLAHUN (NW1rX I. Maintain a minimum 516" edge distance, I" end distance,& I"o.c. spacing of wood screws to prevent the splitting of wood SnUKEJAMB LATCH & DEADBOLT DETAIL HINGE DETAIL cn 0 dO CS z z d 0 3E2 0. z 0 in Z' 2 wq n m a: oz V L4 s"L ,e 8 coXV E5 itWJ r m I Luo o ix a. a �191N I I lzi z a z Ej ?1/08 z a N.T.S. 10 AL M, BY.. LFS -rc - OF BILL OF MATERIALS ITEM DESCRIPTION MATERIAL ITEM DESCRIPTION MATERIAL A 1 X BUCK SG >= 0.55 WOOD 40 FIBERGLASS DOOR PANEL - SMOOTH STAR B 2X BUCK SG >= 0.55 WOOD 41 FIBERGLASS SMC SKIN MIN 0.065' THICKNESS SMC C MAX, IN SHIM SPACE WOOD 42 1 TOP RAIL COMPOSITE D 1 /4" X 2-3 4" PFH ELCO OR 9W CONCRETE SCREW STEEL 43 1 LATCH STILE WOOD E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 44 HINGE STILE WOOD 45 BOTTOM RAIL WOOD F 1/4" X 1-3/4" PFH ITW CONCRETE SCREW STEEL 46 POLYURETHANE FOAM CORE -1.9 LBS. DENSITY FOAM G 3/16" X 3-1 /4" PFH ITW CONCRETE SCREW STEEL 47 LOCK BLOCK REINFORCEMENT WOOD H 1/4'x3-1/4"PFHITW CONCRETE SCREW STEEL 50 FIBERGLASS DOOR PANEL - FIBER CLASSIC - I 1 /4" X 2-1 /4" PFH ITW CONCRETE SCREW STEEL 51 FIBERGLASS SMC SKIN MIN 0.065' THICKNESS SMC J 1 /4" X 3-3/4" PFH ITW CONCRETE SCREW STEEL 52 TOP RAIL COMPOSITE K #8 X 2-1 /2" PFH WOOD SCREW STEEL _53 LATCH STILE WOOD L #10 X 2-1 2" PFH WOOD SCREW 1.15" MIN. EMBEDMENT STEEL 54 HINGE STILE WOOD 1 EXTERIOR LITE FRAME ALUMINUM 55 BOTTOM RAIL COMPOSITE 2 INTERIOR LITE FRAME ALUMINUM 56 POLYUREFHANE FOAM CORE -1.9 LBS. DENSITY FOAM 3 L7 LITE FRAME TRIM PVC 57 LOCK BLOCK REINFORCEMENT WOOD 4 #10 X 1-1 /2" PFH SCREW STEEL 60 FIBERGLASS DOOR PANEL - CLASSIC CRAFT & CLASSIC CRAFT RUSTIC MEDIUM REACH COMPRESSION WEATHERSTRIP FOAM 61 1 FIBERGLASS SMC SKIN MIN 0.090" THICKNESS SMC 8 LONG REACH COMPRESSION WEATHERSTRIP FOAM 62 TOP RAIL COMPOSITE 9 4" X V HINGE .097' THK. STEEL 63 LATCH STILE WOOD 10 #10 X 3/4" PFH WOOD SCREW STEEL 64 HINGE STILE WOOD 17 PASSAGE LOCK - KWIKSET SIGNATURE SERIES STEEL 65 BOTTOM RAIL COMPOSITE 18 THRESHOLD OUTSWING HERMA-TRU ALUM./WOOD 66 POLYURETHANE FOAM CORE -1.9 LBS. DENSITY FOAM 19 HEADER JAMB PIN SG >= 0.42 WOOD --{ 1.318" 20 SIDE JAMB PINE SG >= 0.42 WOOD 21 DEADBOLT - KWIKSET SIGNATURE SERIES 780 STEEL 27 LATCH STRIKE PLATE STEEL42 28 DEADBOLT PLATE STEEL 32 DOOR BOTTOM SWEEP PVC 33 INSWING THRESHOLD ALUM.COMP. NOTE: WOOD DOOR COMPONENTS: PINE OR OAK (SG >= 0.42) 5.83" TT 5 µ .<iy, 1 INSWING 33 Threshold Fes-- 4.563" O 18 OUISWING fireshold r V.JJV 3 llir- FRAME Trim '\EXT. WE Z INi. UrE ' Frame Frame OR— �1''1111ii co it N 8 N y 9 o Z 0 Z N C p LO p m J c o �o E aZ 8 3a 4.563" h II o I—2.359"—TT ^ ^ ^ N ^ C M N ^ 421 08 SULE N.T.S. DWc. eY: AL 19 20 HEAD II. SIDE OX BY: In Jamb DRAWIND ND.: FL-7640.1