Loading...
HomeMy WebLinkAboutMOBILE HOME INSPECTION REPORTPam, All All Addre Year � Width C=1r Revisal St Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce, FL 34982 SCANNED BY Mobile Home Inspection Repot LudeCOU01, for permits to place or replace used Mobile / Manufactured homes must be accompanied by this Inspection Report and copies of both sides of the Title to the home. Mobile homes must be Wind Zone II certif led. CgneE2ACF YER S Date:/QA/ (Print or type) fR IP' cE, FL ; , PW 91970 A Fi.A. &Z22 o� Serial# P8 9159M9 HUD Plate# (FZA SaaaOr Length &b Single N = Not in Compliance DoublWind Zone Fire Safety / Electrical 1. Smoke Detector: Installed Missing 2. Electrical System Checked: Exposed Wiring Other 3. Distribution Panel: Missing Loose Main Missing Breaker Missing Unplugged Opening Other CONCEALED FASTENERS OR ATTACHMENTS 4. Electrical Fixtures: Missing Installed Improperly ARE THE RESPONSIBILITY OF THE Improperly Wired Loose Wire CONTRACTOR OF RECORD GFCI receptacles not where required 5. Electrical Ground: Chassis Main Panel Gas Pipe THESE PLANS AND ALL PROPOSED ARE SUDJECT TO ANY COPIREC T IONS REQUIRED SY MEW INSPECTORS THAT SAY➢E NECESSARY IN ORDER TO COiMWWITH A L APPLICASU OODES. Page 1 of 3 �-7 —olo(o ST. LUCIE COUNTY BUILDING DIVISIO REVIEWED FOR COMPL NC REVIEWED BY DATE PLANS AND PER 11T MUST BE KEPT ON OB OR NO INSPECTION WIL BE MADE rAl Construction .1. Exit Doors Operable: Front Back Other 2. Exit Door Locks: Missing Inoperable 3. Egress windows: Missing Inoperable .4. Windows: Broken Glass Inoperable 5. Screens: Missing Damaged .6. Floor System: Joist Decking Area Damaged .7. Interior Paneling: Missing Loose Damaged . 8. Rodent Proofing: Bottom Board Pipe openings Other .9. Leaks Apparent: Ceiling Doors Floor Roof _ 10. Vertical tie -down straps: Missing Short Damaged 11. Structural modifications since manufactured: YES_ NO_X/__ 12. Walls: Structurally Unsound Loose Weather tight _ Plumbing 1. Trap: Missing Not connected Other 2. Plumbing fixtures: Missing Not installed Not Vented l3. Relief Valve: Missing Inoperable Other 4. Drain Waste and Venting Piping: Missing Not supported Clean outs Use of fittings Not capped Heating and Air Conditioning 11. Heating Appliances: Missing Not Connected Other. 2. Deleted Heating/AC system: Not installed Other. 3. Thermostat: Missing Inoperable 4. Air registers: Missing Inoperable , 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 0 6. Gas furnace Water heater vent: Missing Loose Return Air: To Furnace To A/C From rooms Range: Vent Hood Gas Valve: Accessible Installed improperly 0. Gas lines: Not capped Not supported Kinked Not bonded Sumt,hary 1. Is ubject structure found to be fifty (50%) or more damaged or deteriorated? YES NOV1 2. W� I a remodeling permit be required? YES NOV/ The pr visions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than t se standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited o, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 IF ANIj RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PE FORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEP RATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST STAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MI BILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOC ED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBFOITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A RJ�ISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX THEIR SEAL. Date in ' pected: It-,,474j Z2 Inspect By: V J V f. �� License # 3 L 3 J v sign ture required _ !�/��!$ Phone umber: ( Engine Seal Page 3 of 3 STEVEN G. WOOD, P.E. yL LICENSE W98 �y f��[o SULTy11�,N DR Fp