Loading...
HomeMy WebLinkAboutPERMIT WORKSHEETPERMIT NUMBER (i�!✓1 i / 1 /a %d1 LlCense r'ur ..�lT �( �! .J' Z Address of home �%l /�cr�C��i�' /� � l G�i�'/ i r-c Installer .66 ............... W' being Installed Manufacturer �`-c-�n /� ��n%^ Length x width NOTE, 'it home Is a single wide fill out one half of the blocking plan If horde Is a triple or quad wide sketch In temalnder'of home I understand Lateral Arm Systems cannot be used on any home (new, or Mare the sidewall ties exceed 5 ft 4 in; Installer's Initials Typical pier spacing 2• lateral PERMIT WORKSHEET CD m nm M !D Amy o 0 New Home ❑ Used Home .2 rr Home installed to the Manufacturer's Installation Manual Home is installed in accordance with Rule 15-0 page 1 of 2 I� Single wide ❑ Wind Zone II ❑ Wind Zone III ® -- Double wide Installation Decal F TriplarQuad ® Serial PIER SPACING TABLE FOR USED HOMES Load bearing capacity Footer size (sq In) i 6' x Is, (256) is 112, x is 1l2' (342) 20' x 20' (40D) 22' x 22° (484)° 24' X 24' (576)` 26' x 26, (676) 10D0 s 3 4 1 00 IDs 4 6 6 8 DO s 6' 8 8 8 2 00 s 6 8 8 8 '3000 C)ST 8 81 8 8 3 00 Dst 1 8.a,- 8 Interpolatea rrom hule'Ibu-1 pier spacing lade, PIER PAD SIZES I-beam pier pad size �. Perimeter pier pad size Other pier pad sizes / :12Z Y, (required by the mfq.) MIDraw the approximate locations of marriage I wall openings 4 foot or greater. Use this symbol to show the piers, List all marriage wall openings greater than 4 foot and.their pier pad sizes below, POPULAR PAD SIZES �.T�s'i�.ie� • � � ANCHORS Opening Pier pad: -size ft 5 ft / 4 - FRAMETIEs within 2' of end of home ! jFr/ X /L spaced at 5' 4" oc �/ TIEDOWN COMPONENTS OTHER 71E5 Number Longliudlnal Stabillzln Device (LSD) Sidewall Manufacturer min dLl ee� Longitudinal Longitudinal Stabll•Izing Device wl Lateral Arms Marriage wall. Manufacturer- d12 m Shearwall POCKET PENETROMETER TEST The pbcket penetrometer tests are rounded down to psf or check hereto declare f DOD lb, soil without testing. X X X POCKET PENETROMETER TESTING METHOD 1.- Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the.footer. 3. Using 500 lb, increments, take the lowest readinq'and round down to that increment. X X X TORQUE PROBE TEST The results of the torque probe test Is inch pounds or check here if you are declaring 5' anchors without testing . A test showing 275 inoh pounds or less will require 5 foot anchors, Note: A state approved lateral arm system is being used and 4 ft, .anchors are allowed at•the sidewall locations. i understand 5 ft anchors are required at all centerline tie points where the torque test reading is 275'or less and where the mobile home manufacturer may requires anchors with 400 inq capacity. Installer's initials ALL TESTS MU_5TPERFORMED BYAJUCENSED INSTALLER Installer Name Date Tested 1 Electrical lonnect electrical conductors between multi -wide units, but not to the main power ource. This•ingludes the bonding wire between mutt -wide units. Pg. Plumbinq . bnnect all sewer drains to an existing sewer tap or septic tank. Pq. onnect all potable water supply piping to an existing water ete aier tap, or other tdependegt water supply systems, Pg.��� PERMIT WORKSHEET 1 page 2 of 2 I Debris and organic material remo_f�Iq_<_ Water drainage: Natural Swale Pad Other Fastening multi wide units Floor: Type Fastener `_— Length: ! Spacing: r� X� Walls: Type Fastener Length: Spacing: 68' CJ G Roof: Type Fastener: Length. K " Spacing: /&- C> For. used homes' a twin. so gauge, 8" wide, galvanized metal strip will be centered over the peak of the -roof and fastened with gaiv. - roofinq nails at 2" on center on both sides of the centerline, Gasket(we therproofingr&gulremant) -i understand a properly installed gasket is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of -a poorly installed or no gasket being installed. I understand a strip of tape will not serve as a gasket. /�' Installer's initials / Type gasket �r✓«%`1�' Installed: Pg. Between Floors Yes Between Walls -Yes Bottom of ridgebeam Yes Weatherprooflng The bottomboard will be repaired and/or taped. Yes Pg. Siding on units is installed to manutacturer`s specifications.' Yes Fireplace chimney Installed so as not to allow intrusion of rain water, Yes Skirting to be installed. Yes ' No Dryervent installed outside of skirting. Yes N/A Range downflow vent installed, outside of skirting. Y WA Drain lines supported at 4 foot intgrvals. Electrical crossovers protected. Yes Other: installer verifies al.l information given with this permit Worksheet is accurate and. true based on the manufacturer's insta.11e ion lnstrucf=s and or Rule 150-1 & 2 installer Signature r Date