HomeMy WebLinkAboutLETTER ROOF SPECIFICATIONSkchitecto"--t Inc
ly 20, 2018 SCANNED
BY
lint Lucie County Building DepartmeAtLuey
dGo*
In: Roof Permit Plan, Review
MO Virginia Avenue
Pierce, FL 34982
foe: Roofing specification prepared for the. St. Lucie County Building Dept. for the structure
located at 4900 Palm Drive, St. Lucie County; FL
anufacturer:
ofiles:
)de:
irid Speed:
;posure:
can Roof Height:
FPhi
squired Design Pressure:
aximum Uplift Pressure:
ise:
ly Sheet:
Tri-Built Roofing Products
Tri —Built Modified, FL# 16027-R2
FBC 2017; Section R 905,10
165 MPH; Ultimate Design Wind Speeds
C
30' Maximum
/12
Zone1: =33.5 Zone 2: -52.8 Zone3:-73.45
-60 Zone 1 & Zone 2, -96.9 Zone,3
Certain Teed Glasbase with 32.ga. 1-5/8" diameter Tin Caps w/ 11 ga.,
Annular ring shank nails @ 8" ox. in 4 inch lap and 8" o.c. in three
equally spaced, staggered center rows Zone 1 & 2, Zone 3 fasteners
shall be spaced @ 6" o.c. in 4 inch lap & 6" o.c. in`three equally spaced
staggered center rows
(Optional) One or more SBS-SA or APP-TA
SBS-SA, APP-SA, SBS-TA OR APP-TA
above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code,
s recommendations.
Iloilo
e ectfuP LSY944
t�d•
bo'
F
AIR
Rg6 a C
A
�. •_
FILE COPS`
,'qC'Je'r-n.1 �-
1 WO-7-
Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1