HomeMy WebLinkAboutPRODUCT APPROVALSCANNEDBY
Professional -
Regullation st,Lude coal*
r:
BCIS Home I Log In I User Registration I Hot Topic tamSubmit Surcharge ! Stats & Facts Publications I Contact Us I BCIS Site Map I Links Search
W,10 ALED FATI El
ProdUSER: Public User r oval FILE COPY ' ACTOR OR RECORD
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
FL16027-R2
Revision
2017
Approved
RECEIVED
JUL 2 4 2018
ST. Lucie County, Permittin
❑ qy
Tri-Built Materials Group, LLC/�e--
PO Box 70
Rutherford, NJ 07070
david 5 david.ruiz@tribuiltmg.co
ST. LUCIE COUNTY BUILDI*DIISIOdavid.ruin@tribuiltmg.cor�EVIEWED FOR COMPLIANREVIDavid Ruiz rPATE
david.ruiz@tribuiltmg.co PLANS AN PER IT MUST JOB
SITE OR NO INSPECTIONSADE
David Ruiz.
250 Route 17 North
East Rutherford, NJ 07073
(201)842-2449
david.ruiz@tribuiltmateriaisgroup.com
C Richard Schurman
9050 Louisiana Street
Merrillville, IN 46410
rich.schu rman @a Iliedbu ild ing.comCONC
��l.EE D FASTBNER3 OR An.ACHMEfJTgj
Roofing i�
E RESPONSIBILITY OF THE
Modified Bitumen Roof System n+'h;i&ORORRECORD
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
10/06/2018
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL16027 R2 COI 2017 01 COI Nieminen.Ddf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D6163
2008
ASTM D6164
2011
ASTM D6222
2011
FM 4470
2012
FM 4474
2011
Equivalence of Product Standards
Certified By
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 09/30/2017
Date Pending FBC Approval 10/08/2017
Date Approved 12/12/2017
Summary of Products
FL #
Model, Number or Name
Description
16027.1
TRI-BUILT Modified Bitumen Roof
SBS and APP modified bitumen roof systems
Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16027 R2 II 2017 09 FINAL Al ER TRI-
Approved for use outside HVHZ: Yes
BUILT MODBIT FL16027-R2.Ddf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The Design Pressure noted in this application
Evaluation Reports
refers to one system. Refer to ER Appendix for all systems
FL16027 R2 AE 2017 09 FINAL ER TRI-
and max. design pressures. 2.) Refer to ER Section 5 for
BUILT MODBIT FL16027-R2.pdf
Limits of Use.
Created by Independent Third Party: Yes
Beck Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click ham.
Product Approval Accepts:
"M a 507 eGh
Credit Card
Safe
TRINITY I ERD
APPEN
ik1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table
Deck
Application___,____
Type
Description _ LL,
Page
Wood;
[Jew -or Re[oofGear-Off)
A-2 .
if!Mech:•AttSheet, Bonded lnsulationfaddidi $if.Cover-�I
4
IA-2"
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5
1B
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
5
1C
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
6
1D
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
6
3E-1
Wood
New or Reroof (Tear -off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
7
1E-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
8
1F
Wood
New or Reroof(Tear-Off)
F
Non -Insulated, Bonded Roof Cover
8
2A
Steel or Structural concrete
New, Reroof (Tear -Oft) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
9
2B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech, Attached Insulation, Bonded Roof Cover
9
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
10
3A
Structural concrete
New or Reroof (Tear -off)
A-1
Bonded Insulation, Bonded Roof Cover
11-14
3B
Structural concrete
New or Reroof (Tear -off)
F
Non -Insulated, Bonded Roof Cover
14
4A
LWIC
New or Reroof (Tear -off)
A-1
Bonded Insulation, Bonded Roof Cover
15-16
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
16
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
17-19
5A
CWF
New or Reroof (Tear -off)
A-1
Bonded Insulation, Bonded Roof Cover
20
58
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded.Roof Cover
21
SC
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22
SD
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
22
SE
CWF
New, Reroof (Tear -Off) Or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
22
6A
Gypsum
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
23
6B '�
Gypsum
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
24
6C
Gypsum
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
24
6D
Gypsum
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
24
7A
Various
Recover
A-1
Bonded Insulation, Banded Roof Cover
25-26
7B
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
26
The fc
flowina notes apply to the systems outlined herein:
a roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
ad resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
isulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢ Wood: Minimum 0.75-inch penetration.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute ofthe steel deck.
➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturers published installation instructions.
nless otherwise noted, insulation may be any one layer or combination of polyLocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA
quirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
r Research and Design, U.C. d/b/a Trinity)ERD Evaluation Report A42970.10.12-R2 for FL36027-R2
ate of Authorization #9503 hie EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
d by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 526-1485 Appendix 1, Page 1 of 26
1.
I,
2. I1
3.
Exterl
Certifi
Prepa
TRINITY ERD
j TABLE 1A-1: WOOD DECKS —NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
Deck
Anchor Sheet
Base Insulation
Top Insulation
Roof Cover (Note 15)
MDP
No.
(Note 1)
Type
Fasteners
Attach
Type
Attach
Type
Attach
Base Ply
Ply
Cap Ply
(Psf)
Min. 0.25-inch Dens
8-inch o.c. in 4-
Deck, Dens Deck Prime,
Polyglass G2 Base,
32 ga., 1-5/8-
inch lap and 8-
(Optional) FBC
SECUROCK Gypsum -
Min. 19/32-
CertalnTeed Glasbase,
Base, JM
inch diameter
inch o.c. in
Approved,
Fiber Roof Board, Min.
(Optional)
SBS-AA,
W 1
inch plywood
Firestone MB
tin caps with 11
three, equally
ASTM C1289,
HA
0.75-inch FescoBoard
HA
BP -AA
SBS-TA,
-60.0
at max. 24-
Perma-Ply 28, Tamko
a annular ringtype
g'
spaced,
yp II p of y +so-
(homogeneous) or min.
( g )
BP AA
APP TA
inch spans
Glass Base or
shanknails
staggered
cyanurate
0.5-inch Structodek
GAFGLAS#75
center rows
High Density Fiberboard
Roof Insulation
Polyglass
8ynch'n'`c m;
-;
G26ase;
I
32 ga., 1-5/8- I
p,an.�-
+ inri>>lap and 8-
(Optional) FBC
(Optional)
Min. 19/32-
inch
CertainTeed Glasbase,
Firestone MB Base, JM
inch diameter
t
mch o=-- S.
j
Approved,
Min.0.25-inch Dens
Deck, Dens Deck Prime,
_
_
�
A��
One or J_
SBS-SA,.
<r�• ',27
APP-_SA,
W-2
plywood
tin caps with 11
th ee; equallyj,
ASTM C1289,
HA
HA
6' vd
Amore 585''
-60.0
max. 2
at max. 24-
Perma-Ply 28, Tamko
ga. annular ring
spaceed,. " , j
type 11 polyiso-
SECUROCK Gypsum-
(,
t�.�--"
.r*'
dSA o
SBS-TA or
Inch spans
Glass Base or
shank nails
staggered_ t1
cyanurate
Fiber Roof Board
s
APP TA
APP-TA
GAFGLAS #75
'-✓
:centervrows-
6-hich o.c. in 4-
Min. 2-inch
DAS, OB500,
Min. 19/32-
32 ga., 1-5/8-
Inch lap and 6-
ACFoam II, III,
CR-20 or M-
Min. 0.25-inch Dens
D-I5,
inch plywood
Polyglass Elastobase
inch diameter
Inch o.c. in
H-
OSFA, atop
Deck, Dens Deck Prime
OB500,
(Optional)
SBS-AA,
W 3
at max. 24-
or Polyglass
tin caps with 12
four, equally
ShieH-Shld O,
Shield CG,
fastener
or SECUROCK Gypsum-
CR-20 or
BP AA
BP -AA
SBS TA,
-60.0•
inch spans
Elastobase Poly
ga. annular ring
spaced,
Multi -Max FA3
rows, 7-Inch
Fiber Roof Board
M-OSFA
APP-TA
shank nails
staggered
or ENRGY-3
oc
center rows
6-inch o.c. in 4-
Min. 2-inch
DAS, OB500,
Min. 19/32-
32 ga., 1-5/8-
inch lap and 6-
ACFoam II, III,
CR-20 or M-
D-IS,
(Optional)
SBS-SA,
inch plywood
Polyglass Elastobase
Inch diameter
inch o.c. in
H-Shield, H-
OSFA, atop
(Optional) Additional
OB500,
One or
APP SA,
W-4
at max. 24-
or Polyglass
tin raps with 12
four, equally
Shield CG,
fastener
layers of base insulation
CR-20 or
SBS-SA
more SBS-
SBS TA or
-60.0'
inch spans
Elastobase Poly
ga. annular ring
spaced,
Max FA3
rows, 7-inch
M-OSFA
SA or
APP TA
shank nails
staggered
or ENRGY-3
or EN
oc
APP TA
center rows
research and Design, U.C. d/b/a Trinity IERD Evaluation Report A42970.10.12-R2 for FL16027-RZ
e of Authorization #9503 6'" EDITION (2017) FBC NON-WHZ EVALUATION Revision 2: 09/25/2017