Loading...
HomeMy WebLinkAboutREVISIONOFFIC USE ONLY: DATE t,i ED:REVISFEE: �� • `t3 BY 9t. iLude Coo* �I T. LUCIE -OU TY BUILDI�NVG D ION EVIEWED FOR OMPLIANCE-4-;i, A/ LANS AND PE MIT MUST BE ITE OR NO INPECTION(S) J JOB, MADE PERMIT # RECEIPT # $ 3 y PLANNING & DEVELOPMENT SERVICES lwmrmCTOE U][LDING E REGULATION DMSION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 RECEIVED (772) 462.1553 AUG 0 2 2i�1� APPLICATION FORBUILDING PERMIT REVISIO S - - PROJECT INFORMATION Fl- TLCle GP LOCATION/SITE ADDRESS: o A4: I-. DETAILED DESCRIPTION OF PROJECT REVISIONS: L�lc9 J CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: 6 ADDRESS: 2 1 CITY: 5+ PHONE ( AYTIME):L� OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME: ST. LUCIE CO CERT. #: d• c-5 a ZIP: FAX: STATE: ZIP: FAX: ARCMTECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: ZIP: ! 8 OR A O� 7HE� ISIBILfry OR RECORD SLCCC. 9123109 Revised 06/30� SE PLANS AND ALL PROPOSED WORK �fF1E SUBJECT TO ANY CORRECTIONS R.IEVISION REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. jtl,4fy TRINITY !,ERD Table Deck Application Type Description Page 1A-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 1A-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 5 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 SD Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 6 lE-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 7 Wood Mech. Attached Base Sheet. Bonded 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 9 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 10 3A Structural concrete New or Reroof (Tear -off) A-1 Bonded Insulation, Bonded Roof Cover 11-14 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 14 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 15-16 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 16 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-19 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 20 SB CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 21 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22 SD CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 22 SE CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 22 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 23 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 24 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 24 6D Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 24 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 25-26 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 26 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-Inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturers published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the OA requirements of FAC. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.30.12-R2 for FL16027-RZ Certificate of Authorization #9503 Gn' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 1 of 26 TRINITY I ERD 4. Minimum 200 psi, minimum 2-inch thick lightweight Insulating concrete may be substituted for rigid Insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturers published instructions. D HA (HA): Full coverage at 25-30 lbs/square. D Dow INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. D Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. D OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. (Pace Cart or SpotShot). Nate: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-Inch wide ribbons, 12-inch o.c. D Note: When multiple layers(s) of insulation and/or coverbaard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. D Note., The maximum edge distancefrom the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. in no case shall these values be used to 'increase'the MOP listings in the tables; rather if MOP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MOP -157.5 psf (Min. 0.5-inch thick) D OMG OlyBond 500 (O11500): MOP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) D OMG OlyBond 500 (08500): MOP -1875 psf (Min. 0.5-inch thick ISO 95+GQ D OMG OlyBond 500 (OB500): MOP -315.0 psf (Min. 0.5-inch thick ENRGY 3) D OMG OlyBond 500 (OB500): MOP -487.5 psf (Min. 0.5-inch thick ACFoam 11) D ICP Adhesive & Sealants CR-20: MOP -117.5 psf (Min. 1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 30D psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report A42970.30.12-R2 for FL160Z7-R2 Certificate of Authorization #9503 6'a EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2:09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) S16-1485 Appendix 1, Page 2 of 26 QCt TRINITY ERD 15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. .. r"w ,.>. e. ..o. .w ta.. r..: F www. r..TltBLEl TRI BUILTROOF CDVER$ w.a. srrt )............. :.s a wear ""• �swsarr rw' , Reference Layer Material Application BP -AA Base Ply FBC Approved ASTM D4601, Type II HA at 20-40lbs/square Ply FBC Approved ASTM D2178, Type IV or VI (Base and Ply sheets, Asphalt -Applied) SBS-AA Cap Ply TriBuilt SBS Granular HA at 20-40 lbs/square (SBS, Asphalt -Applied) SBS-TA Cap Ply TriBuilt SBS Granular Torch -Applied (SBS, Torch -Applied) SBS-SA Base Ply TriBuilt SA SBS Base Self -Adhering Cap Ply TriBuilt SASBS Cap (SBS, Self -Adhering) APP-TA Base Ply or Ply TriBuilt APP Smooth Torch -Applied Cap Ply THBuilt APP Smooth, TriBuilt APP Granular (APP, Torch -Applied) APP-SA Cap Ply TriBuilt SA APP Cap Self -Adhering (APP, Self -Adhering) 16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs, those in Table 3A applies: _ NA6dRBARR(Eft,UPT10NS;SiRt1CTURAI`CONCRE7F,DECK;JitfHERE01N3U1/WYIdtIP,Ei(TAs1E9/1„�", -... .. _.._ .. _... drn aw . ww nr. r m a _ ,,,na. ...,..=..«p« a"�„------ ,..------ ,...a, m_..._a. ..,.. ,. Option # Primer Vapor Barrier Insulation Adhesive MDP (psi) Type Attach VB-1. ASTM D41 TriBuilt SASBS Base Self -Adhering Inta-Stik or CR-20, 12-inch o.c. -60.0 VB-2. ASTM D41 TriBuilt SA SBS Cap Self -Adhering Insta-Stik, 12-inch o.c. -75.0 VB-3. ASTM D41 TrlBullt SASBS Cap Self -Adhering Millennium One Step Foamable Adhesive, 12-inch o.c. -157.5 VB-4. ASTM D41 THBuilt SASBS Cap Self -Adhering CR-20, 12-Inch o.c. -270.0 VB-5. ASTM D41 TriBuiltSASBS Base Self -Adhering Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade Adhesive, OlyBond 500 or CR-20, 12-inch o.c. -290.0 17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements. 18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, U.C. d/b/a Trinity ( ERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization #9503 6rx EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59165 TRI-BUILT Modred Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 3 of 26 \ i ti( TRINITY ! ERD �x�.r a lwa'r-°s r¢xree r�r ¢n" a sn anrri rse R¢i s�r`TABLE'1A.1.rWOODDECICS" VIEW CONSTRUCTIN OR REROOFr(TFAR.OFF) ' emrcx a'mr €s rx svm a a °P ¢c�` ERR aw es ntc cz a¢¢eea¢rr¢ 10 s efm¢¢eer¢ ¢a¢v ¢mre as• ¢ P rrr.i.¢rvsi r.¢•A�oie •a-�rcrr">iSYSTEMTI!P9A2 ;MECHANfCACLYATTACH_EDANCHQRSHEE1�.80NDED:INSULATION�BONDEDROOfCOVERya . ,.ne<sxrms__ _¢ _ _.r_a=_ .:. s mxn_ System Deck Anchor5heet Base Insulation Top Insulation Roof Cover (Note 15) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 0.25-inch Dens 8-inch o.c. in 4- Deck, Dens Deck Prime, Polyglass G2 Base, 32 ga., 1-5/8- inch lap and 8- (Optional)FBC SECUROCKGypsum- Min. 19/32- CertainTeed Glasbase, inch diameter inch o.c. in Approved, Fiber Roof Board, Min. SBS-AA, W 1 inch plywood Firestone MB Base, JM tin caps with 11 three, equally ASTM C3289, HA 0.75-inch FescoBoard HA BP -AA (Optional) SBS-TA, -60.0 at max. 24- Perma-Ply 28, Tamko ga. annular ring spaced, type II polyiso- (homogeneous) or min. BP -AA APP-TA inch spans Glass Base or shank nails staggered cyanurate 0.5-inch Structodek GAFGLAStl75 center rows High Density Fiberboard Roof Insulation G Polyglass G2 Base, 4- 8-inch o.c. in 4- 32 ga., 1-5/8- inch lap and 8- (Optional) FBC (Optional) Min. 19/32- Certaiass Glasbase, inch diameter inch o.c. in Approved, Min. 0.25-inch Dens One or SBS-SA, W 2 in o inch plywood Firestone MB Base,JM tin caps with 11 three, equally ASTM C1289, HA Deck, Dens Deck Prime, HA SBS-SA more SBS- APP-SA, -60.0 max. Peestoney 28, Tamko ga. annular ring spaced, type 11 polyiso- SECUROCK Gypsum- SA or SBS TA or inch spans Glass Base or Fiber Roof Board APP-TA GAFGLASt175 shank nails staggered cyanurate APP-TA center rows 6-inch o.c. In 4- Min. 2-inch D-15, OB500, 32 ga., 1-5/8- inch lap and 6- Min.19/32- Polyglass Elastobase inch diameter inch o.c. in ACFoam II, III, CR-20 or M- Min. 0.25-inch Dens D-IS, SBS-AA, W 3 inch plywood or Polyglass tin caps with 12 four, equally H-Shield, H- OSFA, atop Deck, Dens Deck Prime OB500, BP-AA (Optional) (Optional)SBS-TA, -60.0• at max. 24- Elastobase Poly ga. annular ring spaced, Shield CG, fastener or SECU ROCK Gypsum- CR-20 or APP TA inch spans Multi -Max FA3 rows, 7-inch Fiber Roof Board M-OSFA shank nails staggered or ENRGY-3 oc center rows 6-inch o.c. In 4- Min. 2-inch D-IS, OB500, Min. 32 ga., 1-5/8- inch lap and 6- ACFoam II, III, CR-20 or M- D-I5, (Optional) SBS-SA, lywoo inch plywood Polyglass Elastobase inch diameter inch o.c. In H-Shield, H- OSFA, atop (Optional) Additional OB500, One or APP SA, W-4 at max. 24- or Polyglass tin caps with 12 four, equally Shield CG, fastener layers of base insulation CR-20 or SBS-SA more SBS- SBS-TA or -60.0• inch spans Elastobase Poly ga. annular ring spaced, Multi -Max FA3 rows, 7-inch M-OSFA APP-TA shank nails staggered APP- TA AP center rows or ENRGY-3 oc Exterior Research and Design, U.C. d/b/a Trinity ( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization 89503 6Tx EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 4 of 26 (-"IQ I TRINITY! ? ERD r AA6rRP r C R r. R eRrr P e C A aFe Ars n...s es s aro-RRo rea x r aTABLE �YA2 WOODDECKS .NEW CONSTROGTION REROOFjTEAe OFF)OR`RECOVER.a;F n ce a ner.k + erve"' ee«sA sr As k2 .. pa*A aAr*rs+:)E a.AA•re=..°rs=e.'_ArSY5TEM7YPEll,2 MECHANICAELYATTACHEUANCHORSHEET;B:�sxee a,c. c"�AerarrnAeey� A sra vareAw€ mar A ess� , AA x_ _ DNDED�INSULATION,'.BONDEDROOFCOJIFRRAa eeAs` A-s_"-R_sar.A a _es:rm ra ec System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Ply I cap Ply (Psf) Min. 0.25-inch Dens Deck, Polyglass 12-inch D.C. in 4- (Optional) FBC Dens Deck Prime, SECUROCK Min. 19/32- Elastobase or OMG Flat inch lap and 12- Approved, Gypsum -Fiber Roof Board, W 5 inch plywood polyglass Bottom Plates inch in two, ASTM C1289, HA Min. 0.75-inch FescoBoard HA BP -AA (Optional) SBS-AA, SBS- -60.0 max. 24 atat max. 24- Elastobase (square) with equally spaced, equally type 11 polyiso- (homogeneous) or min. 0.5- BP -AA TA, APP-TA Poly Roofgrip #12 staggered center cyanurate inch Structodek High Density rows Fiberboard Roof Insulation Polyglass 12-inch D.C. in 4- (Optional) FBC (Optional) Min. 19/32- Elastobase or OMG Flat inch lap and 12- Approved, Min. 0.25-inch Dens Deck, One or 585-SA, APP- W 6 inch plywood polyglass Bottom Plates inch D.C. in two, ASTM C1289, HA Dens Deck Prime, SECU ROCK HA SBS-SA more SBS- SA, SBS-TA -60.0 at max. 24- Elastobase (square) with equallyspaced, type II polyiso- Gypsum -Fiber Roof Board SA or APP- or APP-TA inch spans Poly Roofgrip #12 staggered center rows cyanurate TA : s cr rr.e Arne rr. r Haze TABLEIB,WOODDECKS NEW CONSTRUCTIOIVREROO (TEAR-0FF)oR12ECOVER-a' ARA r P r :A. a rA n " eA a ._®, ,,,;-_;,,,,a , ,.,,,,,..F. - ffA,F,,;+%,*e5Y5TEM?Y�E,B�,MI:<CHAN,�Cl3LLY/►T,'fACHEDpBF1SE1N5ULA'_TION._B4O�IDEDTOP'INSULAT�ON BOfYDED�i00F;COVER,a .o-a,:a,A,.e;G�PF-r :e„-,,.,a.'rcea„�,'e.,e. System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) TyperDekfast teners Attach Type Attach Base Ply Ply Cap Ply (P� Min. 19/32-inch Min. 1.5-inchex with per Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch (Optional if1 (Optional if using AA Base) One SBS-AA, 585-TA, W-7 plywood at max. 24-inch ENRGY 3, H-Shiel2 or TruFast 1.33 ft' Structodek High Density Fiberboard HA using AA Ply) r more BP -AA or APP-TA -60.0 spans or Polytherm TruFast DP Roof Insulation BP APP-TA Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems, (900) 516-1485 Appendix 1, Page 5 of 26 QTilNITYIERD ... (,DE z r oa o nor . r R r ayt r - fTABCEIC WOOD;DECKS NEW CONSTRUCTIONrREROOF)TEAR-0FF)oe.RECOVER ..R.= rEW .0 gaR4 ,rr 64 P4+ {PA .EC F ..... ..A P rr (A r `4rnVe4P.F p..:eee3 A«F r.dr rrrr.re:.r4R..op(ntSYSTEIVI.T1fPEC MECHANICACLYATTl1CHEDINSUUITION;BONDEDRODF'COVER, t.Arer+===Ee r«rrP=rR A _ s 'r r _ oome`oe — - --- - — System Base Insulation Top Insulation layer Roof Cover (Note 15) MDP No. Deck (Note 1) layer (Psf) Type Fasteners Attach Base Ply Ply Cap Ply Min. 19/32-inch (Optional) Min. 0.5-inch Structodek High Density Dekfast Galvalume (Optional if (Optional if using AA W-8 plywood at max. One or more layers, Fiberboard Roof Insulation or min. 0.25- Steel Hex with 1 per 1.33 usinit,g AA Ply) Base) One or more BP -AA SBS-AA, SBS-TA, APP- 82 5 24-inch spans any combination, inch Dens Deck, Dens Deck Prime or Dekfast #12 DP BP -AA or APP-TA TA loose laid SECUROCK Gypsum -Fiber Roof Board (Optional) Dekfast Galvalume Min.19/32-inch One or more layers, Min.1.5-inch ENRGY 3, H-Shield or Steel Hex with 1 per 1.33 (Optional) One or more SBS-SA, APP-SA, SBS- W-9 plywood at max. any combination, Polytherm Dekfast #12 DP or SBS-SA 5BS-SA or APP-TA TA or APP-TA -82.5 24-inch spans TruFast MP-3 with loose laid TruFast DP r r TABLE SD ...... WOODDECKS NENfICONSiRUCT1ON REROOF(TEAaOFF)oRRECOVER ", . ....... rfi F r.. 6AF➢ 6F Y r 4P. '.rS «r R ras$ .. .rc SF R SC ,,, .rrt=r-rrrr:..> ; ,�r„rxSYSTEMTYPE,D,QREUM11VARILY,ATTACNEDINSULATION MECHANICALCYATTACHEDBASE,SHEET BONDEDROOFCOVERm ," System Insulation layers) Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Attach Base Fasteners Attach Base Ply Cap Ply (Psf) Polyglass Elastobase, Polyglass OMG Flat Bottom Plates Min. 19/32-inch Elastobase Poly, Polyglass G2 Base, (square) with Roofgrip 12-inch o.c. in 4-inch lap and 12- (Optional) One SBS-AA, W-10 plywood at max. One or more layers, Prelim. CertainTeed Glasbase, Firestone MB #14, Dekfast Hex with inch o.c. in two, equally spaced, or more BP -AA 5BS-TA, -52.5 24-inch spans any combination Attached Base, JM Perma-Ply 28, Tamko Glass Dekfast #14 or TruFast staggered center rows or APP-TA APP-TA Base or GAFGIAS #75 MP-3 with TruFast HD Min. 19/32-inch Dekfast Hex with Dekfast 12-inch o.c. in 4-inch lap and 12- SBS-SA, W-11 plywood at max. One or more layers, Prelim. Polyglass Elastobase or Polyglass #14 or TruFast MP-3 with inch o.c in two, equally spaced, One or more APP-SA, -52.5• 24-inch spans any combination Attached Elastobase Poly with poly top surface Tru Fast HD staggered center rows SBS-SA 5BS-T or APP TA Min. 19/32-inch 12-inch o.c. in 4-inch lap and 12- (Optional) One SBS-AA, W-12 plywood at max. One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates inch o.c. in two, equally spaced, or more BP -AA SBS-TA, -60.0 24-inch spans any combination Attached Elastobase Poly (square) with Roofgrip #12, staggered center rows or APP-TA APP-TA Min. 19/32-inch One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates 12-inch o.c. in 4-inch lap and 12- One or more SBS-SA, APP-SA, W-13 plywood at max. any combination Attached Elastobase Poly with poly top surface (square) with Roofgrip #12 inch o.c. in two, equally spaced, SSS-SA SBS-TA or -60.0' 24-inch spans staggered center rows APP-TA Exterior Research and Design, LLC. d/b/a Trinity ) ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 536-1485 Appendix 1, Page 6 of 26 TRINITY i ERD �a"" TABLEIr-Ifi OODDECKS NEWCONSTRUCTION1 RERgOF(TiW-, esr$s � e pgp 'wr accr. "s e:aa'siieaz Y PSf Bit FwF a � 4# aC #Aek*�RO P, PoaR rw-a a55uP-En WF> MF3F "`ua R seal?EM 7YPE E"EryC!N 9NSULATED M CHA ICALLI"Q'iTACHEr�B;/ISES,((��EETT MP DEQROOFgCO,I/ER8 F.. FR4RRpS5 R e 6 ¢ w msR:KR -'`"en`_er_r a �eef x ee=.sa' erne System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Base Fasteners Attach Base Ply Cap Ply lPsfl W-14 Min. 15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 9-inch O.C. at 2-inch lap and 18-inch o.c in two, (Optional) BP -AA or SBS-AA, SBS-TA -45.0• inch spans equally spaced, staggered center rows APP-TA or APP-TA W-15 Min. 15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c in two, (Optional) BP -AA or SBS-AA, SBS-TA -52.5 inch spans equally spaced, staggered center rows APP-TA or APP-TA Min. 19/32-inch Polyglass Elastobase, Polyglass Elastobase (Optional) One or W-16 plywood at max. Poly, Polyglass G2 Base, CertainTeed 32 ga., 1-5/8-inch diameter tin caps 8-inch o.c. in 4-inch lap and 8-inch o.c. in three, more BP -AA or SBS-AA, SBS- -60.0 24-inch spans Glasbase, Firestone MB Base, JM Perma- with 11 ga. annular ring shank nails equally spaced, staggered center rows APP TA TA, APP-TA Ply 28, Tamko Glass Base or GAFGLAS #75 Min. 19/32-inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 8-inch o.c. in 4-inch lap and 8-inch o.c. in three, (Optional) One or SBS-SA, APP- W-17 plywood at max. Elastobase Polywith of to surface poly P with 11 a. annular ring shank nails g g equally spaced, staggered center rows q y p gg more SBS-SA or SA, SBS-TA or -60.0 24-inch spans APP-TA APP-TA Min. 15/32-inch 6-inch o.c. at 24nch lap and 6-inch o.c. in two, (Optional) BP -AA or SBS-AA, SBS-TA W-18 plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap equally spaced, staggered center rows APP-TA or APP-TA -90.0 inch spans Min. 19/32-inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 4-inch o.c. in 4-inch lap and 4-inch o.c. in four, (Optional) One or SBS-SA,APP- W-19 plywood at max. Elastobase Polywith of to surface poly p with 11 a. annular ring shank nails. g g equally spaced, staggered center rows q y p gg more SBS-SA or SA, SBS-TA or -97.5 24-inch spans APP-TA APP-TA W-20 Min. 15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three, (Optional) BP -AA or SBS-AA, SBS-TA -105.0 inch spans equally spaced, staggered center rows APP-TA or APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, (Optional) One or SBS-AA, SBS- W-21 plywood at max. Elastobase Poly with 11 ga. annular ring shank nails equally spaced, staggered center rows more BP -AA or TA, APP-TA -112.5 24-inch spans APP-TA Min. 19/32-inch 32 ga., 1-5/8-inch diameter tin caps SBS-SA, APP- W-22 plywood at max. Polyglass Elastobase or Polyglass with 11 ga. annular ring shank nails. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, (Optional) One or SA, SBS-TA or -112.5 24-inch spans Elastobase Pol with of to surface y p y p Note: Tin ca s are to be rimed with P P a uall s aced, sta ered center rows equally p staggered more APP-TA APP-TA ASTM D41 primer. Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL160Z7-R2 Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems, (800) 515-2485 Appendix 1, Page 7 of 26 u "Q TRINITY JERD e raaUOFZrOR ),58SXFt�=o-£ EM Ws6. •ins .. _a.V Il£ £Y R rr °r..�«ve YSTEMTYPE' ON D-MEC A ICg_'Y. ACHEDBASE$H TrBONDEDROOFOVER t rya «£ tacee.a."asa :r•..-o- "gasp'"ia $ �Sssg.._o-?a.u- x - - System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Base - Fasteners Attach Base Ply Cap Ply (Psf) Min. 19/32-inch Polyglass Elastobase, Polyglass Elastobase OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch (Optional) One or W-1 plywood at max. Poly, Polyglass Teed Base, CertBase, Roofgrip #14, Dekfast Hex with Dekfast #14 o.c. in two, equally spaced, staggered more BP -AA or SAS -AA, SBS- -52.5 24-inch spans Glasbase, Firestone MB Base, JM Perma- o J or TruFast MP-3 with TruFast HD center rows APP-TA TA, APP-TA Ply 28, Tamko Glass Base or GAFGLAS #75 W-2 Min. 19/32-inch plywood at max. Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast #14 or TruFast MP- 12-inch o.c. in 4-inch lap and 12-inch o.c. in two, equally spaced, staggered One or more SBS- SBS-SA, APP- SA, SBS-TA or -52.5' 24-inch spans Elastobase Poly with poly top surface 3 with TruFast HD center rows SA APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass OMG Fiat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch (Optional) One or SBS-AA, SBS- W-3 plywood at max. Elastobase Poly Roofgrip #12 o.c. in two, equally spaced, staggered more BP -AA or TA, APP-TA -60.0 24-inch spans center rows APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) withOne 12-inch o.c. in 4-inch lap and 12-inch or more SBS- SBS-SA, APP- W-4 plywood at max. Elastobase Poly with poly top surface Roofgrip #12 o.c in two, equally spaced, staggered SA SA, SBS-TA or -60.0• 24-inch spans center rows APP-TA TABLElF WOODDECKS NEWCONSTRUCn6oio REROOF(TF�tROpF) „SYSTEM-TYQEF NUNAINSULATED,�ONOED,ROOEZOVER. r �a ", ' : ;~ 4 � ry ::: aaq Roof Cover(Note 15) MDP Deck er Primer (Psf) JointTreatment Base Ply Ply Cap Ply ESystem Min. 15/32-inch plywood (Optional)ASTM D41 None SBS (Optional) SBS-SA or BS-SA, APP-SA,SBS-TAat max. 24-inch spans APP-TA orAPP-TA-90.0 Min. 15/32-inch plywood (Optional) ASTM D41 Plywood joints are covered with 4-inch wide strips ofTriBuilt SA TriBuilt SA SBS Base (Optional) SBS-SA or SBS-SA, APP-SA, SBS-TA 97.5 at max. 24-inch spans SBS Base, rolled into place to create continuous bond. APP-TA or APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity( ERD Evaluation Report A42970.30.12-112 for FL16027-RZ Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 8 of 26 �RINOTY;ERD ...n a a sa 3 P n area a rs ' � erTABLE2A STEELCIRSTRUCTURALCONCRETEDECKSNEW'CONSTRUMOM RER- -OOFjTEAR OFP)ISR`-RECOVER.:;. ae xr x s ar rrrP a r . Pa S f Pair Irv�s! � 4 !'frt Pti B F!$#PNkr9#frPR£ Rh rRPlP!?t fA V4p £° rrSYSfEMTYPI 6 MECHANICALLYATFACHEDBASEINSULATION'BONDEDT,OFrINSULAT10N;80NDEQI200FCO,VERP ,%.=' ru s.P a .............. Qi#@Q-lQ4 QSP PR_.-�- .- _ .. System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Type Fasteners Attach Type Attach Base Ply Ply cap Ply (Psf) Min. 22 a., g type B, Min. 1.5-inch Dekfast Hex with Min. 0.75-inch FescoBoard (Optional if using SC-1. Grade 33 steel or ACFoam II, ENRGY Dekfast #14, Trufast MP-3 with Trufast HD or z 1 per 2 ft (homogeneous) or min. 0.5-inch HA (Optional if using AA Base) One or SBS-AA, SBS- "-0• min. 2,500 psi 3, H-Shield or Structodek High Density AA Ply) BP -AA more BP -AA or TA, APP-TA structrual concrete Polytherm OMG 3-inch Daly Plate Fiberboard Roof Insulation APP-TA with OMD HD Min. 22 ga., type B, Min. 2-inch Dekfast Hex with Min. 0.75-inch FescoBoard (Optional if using Grade 33 steel or ACFoam II, ENRGY Dekfast #14, Trufast z (homogeneous) or min. 0.5-inch (Optional if using AA Base) One or SBS-AA, SBS- SC-2. min. 2,500 psi 3, H-Shield or MP-3 with Trufast HD or 1 per 4 ft Structodek High Density HA AA Ply) BP -AA more BP -AA or TA, APP-TA -45.0• structrual concrete Polytherm OMG 3-inch Galy Plate Fiberboard Roof Insulation APP-TA with OMD HD Min. 22 ga., type B, MinGY3inch Dekfast Hex with Min. 0.75-inch FescoBoard (Optional if using SC-3. Grade 33 steel or ENRGY 3, H-Shield Dekfast #14 or TruFast 1 per 1.33 (homogeneous) or min. 0.5-inch HA (Optional if using AA Base) One or 565-AA, SBS- -90.0 min. 2,500 psi W Structodek High Density AA Ply) BP -AA more BP -AA or TA, APP-TA structrual concrete or Polytherm MP-3 with TruFast HD Fiberboard Roof Insulation APP-TA Min. 22 ga., type B, Min. 15-inch Dekfast Hex with Min. 0.75-inch FescoBoard BP -AA (Top surface One or more SBS-SA, APP- SC-4. Grade 33 steel or ENRGY 3, H-Shield Dekfast #14 or TruFast 1 per 1.33 z (homogeneous) or min. 0.5-inch HA primed with ASTM layers, SBS-SA or SA, S65-TA -90.0 min. 2,500 psi or Polytherm MP-3 with TruFast HD ft Structodek High Density D41eprimer) APP-TA or APP-TA structrual concrete Fiberboard Roof Insulation VU1, UN-rf ! £`. F E r ERlQ F TABLE26p5TEELORSTRUCTURA<CQNCRE7EDECKS P tr 2'c NE1AIfCONSTRUC[IONtEROOF(TInnROFF)DRRE,COVER YP rQt nr r .Y !!rW C'r %RM ♦£..£ Q F P r ! - P !P Q 8 -R P9 r FPF R! C:t# S F F . SYrSTEfJITYPE,PC,1ylECHAN�Ct�LLYATTA�kIEDINSULtITION BON'@DROQF�OVER,- _ r«MDP! System Base Insulation Top Insulation layer Roof Cover (Note 15)�Y No. Deck (Note 1) Layer (Psf) Type Fasteners Attach Base Ply Ply Cap Ply Min. 22 ga., type B, (Optional) One or (Optional if (Optional if using AA SC-5. Grade 33 steel or more layers, any Min. 0.5-inch SECUROCK Gypsum- OMG 3-inch Galvalume Steel 1 per 1.78 using AA Ply) Base) One or more BP- SBS-AA, SBS- -75.0 min. 2,500 psi combination, loose Fiber Roof Board Plate with OMG #14 HD ft2 BP -AA AA or APP-TA TA, APP-TA structrual concrete laid _ Min. 0.5-inch Structodek High Min. 22 ga., type B, One or more layers, Density Fiberboard Roof Dekfast Galvalume Steel Hex with (Optional if (Optional if using AA SC-6. Grade 33 steel or any combination, Insulation or min. 0.25-inch Dens Dekfast #12 (steel only) or #14 or 1 per 1.33 using AA Ply) Base) One or more BP- SBS-AA, SBS- 82.5 min. 2,500 psi loose laid Deck, Dens Deck Prime or TruFast MP-3 with TruFast DP ft' BP -AA AA or APP-TA TA, APP-TA structrual concrete SECUROCK Gypsum -Fiber Roof (steel only) or HD Board Min. 22 ga., type B, (Optional) Dekfast Galvalume Steel Hex with SBS-AA, SBS- Grade 33 steel or One or more layers, Min. 1.5-inch ENRGY 3, H-Shield Dekfast #12 (steel only) or #14 or . 1 per 133 (Optional) One or more TA, SBS-SA , 82.5 SC-7. min. 2,500 psi any combination, or Polytherm TruFast MP-3 with TruFast DP W SBS SA SBS-SA or APP-TA APP-TA, APP- structrual concrete loose laid (steel only) or HD SA Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-RZ for FL16027-RZ Certificate of Authorization #9503 6'v EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 5163485 Appendix 1, Page 9 of 26 JTRINITYIERD ......gr£ R°e ee 84 r4s£ "rTABLE2C STEELORSTRUCTURAUCONCRETEDECKS NEWrCONSTRUCTIOMRERO IF(T[AR-0F )7&ECOVER. r« r E rs aerer r sa 4e e a «.r e4mr ik£ +xav« kr� A•� E. Re'r r nYT4a •l[[.er E£ F«p«rk Ft`8mn.1-01 E S<9tfr Pr : r rE zri 9 uk f4 VER k SYSTEM TYPED PRELIMINARILY ATTACHED INSULATION MECHANICALLY�ATTACHEDBASESHEET BONDEDROOECO 4 E r r 4£AnfB s£ kF 49 _ _ 1 E - ran a ar« rm�.e '............« «e«44♦ £ £ :4N F£ s +=«£e.,«ear=9£ra£ag9�44sr.ea`:F4r£F£nr«44r«£say eR94 °'NOTE INSULATIONISOPTIONAL"FOR RECOVER'APpCICATIQ�IS £s,s ae3cFs4 a«v c'ra £ raz£4mvi64a4o-oe'.._ rP, R'.$,h'Bl Pver£r-R f System Insulation Layer(s) Base Sheet Roof Cover (Nate 15) MDP No. Deck (Note 1) Type Attach Base Fasteners Attach Base Ply Cap Ply (Psf) Min. 22 ga., type B, One or more Polyglass Elastobase, Polyglass OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap (Optional) One or SC-8. Grade 33 steel or min. layers, any Prelim. Elastobase Poly or 1M Perma- with Roofgrip #14, Dekfast Hex and 18-inch o.c. in two, more BP -AA or APP- SBS-AA, SBS- -45.0• 2,500 psi structrual Attached with Dekfast #14 or Tru Fast MP-3 equally spaced, staggered TA, APP-TA concrete combination Ply 28 with Trufast HD center rows TA Polyglass Elastobase, Polyglass Min. 22 ga., type B, One or more Elastobase Poly, Polyglass G2 OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap (Optional) One or Grade 33 steel or min. Prelim. Base, CertainTeed Glasbase, with Roofgrip #14, Dekfast Hex and 12-inch o.c. in two, SBS-AA, SBS- SC-9. 2,500 psi structrual layersany Attached Firestone MB Base, JM Perma- with Dekfast #14 orTruFast MP-3 equally spaced, staggered more BP -AA or APP- TA APP TA -52.5 concrete combination Ply 28, Tamko Glass Base or with TruFast HD center rows TA GAFGLAS #75 Min. 22 ga., type 8, One or more Polyglass Elastobase or OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap SBS-SA, APP- SC-10. Grade 33 steel or min. layersany Prelim. Polyglass Elastobase Poly with with Roofgrip #14, Dekfast Hex with and 12-inch o.c. in two, One or more 585-SA SA, SBS-TA -52.5• 2,500 psi structrual Attached Dekfast #14 or Tru Fast MP-3 equally spaced, staggered concrete combination poly top surface with Tru Fast HD center rows or APP-TA Min. 22 ga., type B, One or more OMG Flat Bottom Plates (square) 12-inch o.c. in 4-Inch lap (Optional) One or SC-11. Grade 33 steel or min. layers, any Prelim. Polyglass Elastobase or with Roofgrip #12 (steel only) or and 12-inch o.c. in two, more BP -AA or APP- SBS-AA, SBS- -60.0 2,500 psi structrual Attached Polyglass Elastobase Poly equally spaced, staggered TA, APP-TA concrete combination #14 center rows TA Min. 22 ga., type B, One or more Polyglass Elastobase or OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap SBS-SA, APP- SC-12. Grade 33 steel or min. layers, any Prelim. Polyglass Elastobase Poly with with Roofgrip #12 (steel only) or and 12-inch o.c. in two , One or more SBS-SA SA, SBS-TA -60.0` 2,500 psi structrual Attached equally spaced, staggered concrete combination polytopsurface #14 center rows or APP-TA Min. 22 ga., type B, Grade 80 steel or min. One or more Prelim. Dekfast isofast IF-2.375-AT Plates 12-inch o.c. in the inch SBS-TA, APP- SC-13. 2,500 psi structrual layersany Attached Tri Built APP Smooth with Dekfast #15 HS wide, hea side lap (Optional) APP-TA TA -82.5 concrete combination Min. 22 ga., type B, One or more SC-14. Grade 80 steel or min. layers, any Prelim. TriBuilt APP Smooth Trufast 2.4 in. Barbed Seam 12-inch o.c. in the 5-inch (Optional)APP-TA SBS-TA, APP- -82.5 2,500 psi structrual Attached Plates with Trufast EHD Fasteners wide, heat -welded side lap TA concrete combination Min. 22 ga., type B, One or more Dekfast Hex with Dekfast #14 or 12-inch o.c. in the 4-inch Grade 33 steel or min. Prelim. lap and 18-inch o.c. in two, (Optional) BP -AA or SBS-AA, SBS- SC-15. 2,500 psi structrual layers, any Attached TriBuil[ APP Smooth OMG Flat Bottom Plates with equally spaced, staggered APP-TA TA, APP-TA -112.5 combination OMG Roofgrip #14 concrete I I I center rows Exterior Research and Design, U.C. d/b/a Trinityl ERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization #9503 6Ex EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems, (800) 516-1485 Appendix 1, Page 10 of 26 TRINITY I ERD ------------ (## s.i es assaw eP sx i"vm �mauxvs'npwp z'"wwrv'wrsr%# a'TABLE3A:,"STRUCTURACCONCRET111316 S* :NEW CONSI'RUCTJON UR.REROOF(iEAR.OFFJ`: o-# w r v - #r� r wm r•x� r^rrz#x rwxr sirs eaerv»*e 'n r a;. xaosro a"�vsamrasesr Y#aw ware#�# r rc a>ar ar p rc m.Rss. cv ca+A'a WTFss YY enx"Yr,Y =nwca ne s#i c..PH•s"n�n.`r`wepe #R.aci° R"e-S STE1�I,11'YPEA Z,80NDED IIVSVWl0;W CpONDED,ROOF CODER a: "' Y aR". k S4F A 6'P WD #RM# R!P k'B 6 4T.. #a #f' a C`.9taT 9 4r'YSffiYF#`x £s t#Pk S##&Y9Si#aYT 4 rt%mTPv FKa F# v�n aFmYr amr#a m#eav-s'z un£.kp F"f'ww @ E P%�Y! 9 BffS #ffi#'Fffk E&F H Pl.C' xF6P AP! � BM�a n�3 A.�m X%e s#Qx.mer sw#ur #nrx re�rY a#Y�e ea e�rc�a#rewrr%me.###assae ss€#a€#�n ®aU_" SE '!OTE:16sFOR VI(POfTBA(t(tfEFi`O¢II,DPi a.caoe wruun wnss r amrigid r. Ts��* rwaTmrw'rienArrarrrwsn#na�amd so<ee �YRoof System Base Insulation Layer Top Insulation layer Cover (Note 15) MOP No. Deck Primer Type Attach Type Attach Base Ply Ply Cap Ply (PsR #$E[F;;%tONERIN�+ STEMAS.WItFi BA561Ne1n •YION`r,,'D OP710fiAi,T6P I(SUTATIW,41F'IH�SAIV) n�4 ry},_> .. �'. sY 4rCaY8sc `. IS E(Optional) a aaett w.t me rB Structural (Optional) Min. 1.5-inch H-Shield or Multi -Max additional layers(s) of D-IS SBS-SA (Optional) One or more SBS-SA, APP-SA, -67.5 C-1 concrete ASTM D41 FA3 D-IS insulation SBS-SA or APP-TA SBS-TA or APP-TA Structural (Optional) (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C 2 concrete ASTM D41 Min. 1.5-inch ACFoam II or ENRGY 3 D-IS base insulation D-IS SBS-SA SBS-SA or APP-TA SBS-TAor APP-TA -135.0 C-3 Structural None Min. 1.5-inch, min. 1.5, pcf Insulfoam D-IS (Optional) additional layers of base D-IS SBS-SA (Optional) One or more SBS-SA, APP-SA, -157.5 concrete insulation SBS-SA or APP-TA SBS-TA or APP-TA Structural (Optional) additional layers of base (Optional) One or more SBS-SA, APP-SA, C-4 concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 insulation OB500 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -120.0 Structural (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-5 concrete None Min. 1.5-inch ENRGY 3 OB500 base insulation OB500 SBS-SA SBS-SA or APP-TA SBS-TAor APP-TA -127.5 C-6 Structural None Min. 1.5-inch ACFoam II or H-Shield OB500 (Optional) additional layers(s) of OB500 SBS-SA (Optional) One or more SBS-SA, APP-SA, -150.0 concrete base insulation SBS-SA or APP-TA SBS-TAor APP-TA Structural Min. 1.5-inch ACFoam II, ENRGY 3, H- (Optional) additional layers(s) of M-OSFA SBS-SA (Optional) One or more SBS-SA, APP-SA, -232.5 C 7 concrete None Shield or Multi -Max FA3 M-OSFA base insulation SBS-SA or APP-TA SBS-TA or APP-TA Structural (Optional) additional layers of base (Optional) One or more SBS-SA, APP-SA, 240'0 C-B concrete None Min. 1.5-inch, min. 2.O pcf Insulfoam CR-20 insulation CR-20 SBS-SA SBS-SAor APP-TA SBS-TA or APP-TA Structural Min. 1.5-inch ACFoam 11, ACFoam III, (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C 9 concrete None ENRGY 3, Shield, H-Shield CG, Multi- CR-20 base insulation CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -270.0 Max FA3 orr I50 95+ GL C-10 Structural None Min. 2-inch ACFoam II or H-Shield OB classic (Optional) additional layers(s) of OB Classic SBS-SA (Optional) One or more SBS-SA, APP-SA, -270.0 concrete (FULL) base insulation (FULL) SBS-SA or APP-TA SBS-TA or APP-TA Structural Min. 1.5-inch ACFoam II, ACFoam III, (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-11 concrete ASTM D41 ENRGY3, H-Shield, H-Shield CG or HA base insulation HA SBS-SA SBS-SA or APP-TA SBS-TAor APP-TA -480.0 Multi -Max FA3 _SEIF.�AONERING Sy5TEM5:WRH BA agulA71oNAND.GOYERB_O_ARO .._.-.....,._,,....._ #aae #xrs.. r`r<saa r _ ra r r #mww- ## r. �x* snwx xaa aecre� 2r s-. s cr ez -S x€s.rrsamx#erw """(Optional) aY wa rvs _ sw#a F�r.es xr xa###s#ua _ ---------- Y cs�afir Structural Min. 0.25-inch SECU ROCK Gypsum-4 One or more SBS-SA, APP-SA, C-12 concrete None Min. 1.5-inch Multi -Max FA3 D-IS Fiber Roof Board D-IS SBS-SA SBS-SA or APP-TA SBS-TAor APP-TA -67.5 Structural Min. 0.25-inch Dens Deck, Dens (Optional) One or more SBS-SA, APP-SA, C-13 concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam D-IS Deck Prime D-IS SBS-SA SBS-SA or APP-TA SBS-TA orAPP-TA -120.0 Structural Min. 2-inch ACFoam 11, ENRGY-3 or H- Min. 0.25-inch SECUROCK Gypsum- D-IS SBS-SA (Optional) One or more SBS-SA, APP-SA, 247.5 C-14 concrete None Shield D-IS Fiber Roof Board SBS-SA or APP-TA SBS-TA or APP-TA Structural Min. 0.25-inch Dens Deck, Dens (Optional) One or more SBS-SA, APP-SA, C-15 concrete None Min. 1.5-inch ENRGY3 OB500 Deck Prime OB500 SBS-SA SBS-SA or APP-TA SBS-TAor APP-TA -127.5 Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 515-1485 Appendix 1, Page 11 of 26 T'RININ I ERD Y%R t a e ! q�r -fn R rnri rn r " PIUM, r,rTAB1LE3A WRUCTURAL CONCRETEDECKS NEW C0NSTRUCTIO1JAR RERDDf (TEAR OFF), ;< -R '..z R3� 'R"s . esa` RR "R�' Rr rep Rcsna"° u"rRR ae �a o-a r R a xis®w x.r}s c g> rr rr e. F€ € ea5Y5TEM lYPEAI BONDEDINSULATION BONDED ROOF COVER . rs ts, rrRt _ t ekp *'ar fF8}E RR YRSI.. P -- 9 r. M' }. .YSR F4 Re pnpo-r 4R R¢D pYaB .¢�.,R a a. �' ee^R »i.a sRrRa°°a.«Kenne+ee.°rae RRR xisR�n csts�meas� re«}¢.«errlan Rsr>sePRR sxaen.oRRas�rrFrxe Rrt RN CW s�F. r�EE�lOfE 16}FOR VJIPOR.B�IRRIER"0PTIONS, } rca System Base Insulation layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck Primer Type Attach Type Attach Base Ply Ply . Cap Ply (psf) Structural Min.1.5-loch ACFoam II, H-Shield or Min. 0.25-inch Dens Deck, Dens (Optional) One or more SBS-SA, APP-SA, C-16 concrete None IS095+GL OBSOD Deck Prime OB500 SBS-SA SBS-SA or APP-TA SBS-TAor APP-TA -150.0 C 17 Structural None Min. 2-inch ACFoam II, ENRGY-3 or H- 08500 Min. 015-inch SECUROCK Gypsum- OB500 SBS-SA (Optional) One or more SBS-SA, APP-SA, -247.5 concrete Shield Fiber Roof Board SBS-SA or APP-TA SBS-TA or APP-TA C-10 Structural None Min.1.5-inch ACFoam 11, ENRGY 3, H- M-OSFA Min. 0.25-inch SECUROCK Gypsum- M-OSFA SBS-SA (Optional) One or more SBS-SA, APP-SA, -232.5 concrete Shield or Multi -Max FA3 Fiber Roof Board SBS-SA or APP-TA SBS-TA or APP-TA C-19 Structural None Min-2-inch ACFoam II, ENRGY-3 or H- M-OSFA Min. 0.25-inch SECUROCK Gypsum- M-OSFA SBS-SA (Optional) One or more SBS-SA, APP-SA, -247'S concrete Shield Fiber Roof Board SBS-SA or APP-TA SBS-TAor APP-TA C-20 Structural None Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch Dens Deck, Dens CR-20 SBS-SA (Optional) One or more SBS-SA, APP-SA, 240.0 concrete Deck Prime SBS-SA or APP-TA SBS-TA or APP-TA Min.1.5-inch Ultra -Max or Multi -Max C-21 Structural None FA-3, min. 1.3-inch ACFoam III or min. CR-20 Min- 0.25-inch SECUROCK Gypsum- CR-20 SBS-SA (Optional) One or more SBS-SA, APP-SA, -240.0 concrete 1.0-inch IS095+GL, H-Shield, H-Shield Fiber Roof Board SBS-SA or APP-TA SBS-TAor APP-TA CG or ENRGY 3 C-22 Structural None Min. 24nch ACFoam II, ENRGY-3 or H- CR 20 Min. 0-25-inch SECUROCK Gypsum- CR-20 SBS-SA (Optional) One or more SBS-SA, APP-SA, 247.5 concrete Shield Fiber Roof Board SBS-SA or APP-TA SBS-TA or APP-TA Structural OB Min. 0-25-inch SECUROCK Gypsum- OB (Optional) One or more SBS-SA, APP-SA, C-23 concrete None Min. 2-inch ACFoam II or H-Shield Classic Fiber Roof Board Classic SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -350.0 (FULL) . (FULL) Min. 1.5-inch ACFoam 11, ACFoam Ill, Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C-24 concrete AST.D41 ENRGY 3, H-Shield, H-Shield CG or HA Fiber Roof Board HA SBS-SA SBS-SA or APP-TA SBS-TAor APP-TA -350.0 Multi -Max FA3 - rASPHALT�AND/ORTORCHADPSEDST�TEMS rerts��'c•c®s arrxo nags r�:.p Rx��'•x re�anR .Pe »asp£ ,.�=R�Rrpr_+�}rerRrt�a ns srpape'M«.��a .+�n rp�•r RC R.s�€vr.,rnai�Ri�e.r�ia9«e. �assw ma�R r xr..._ ssxrae Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-25 concrete None Min. 2-inch ACFoam 11 or H-Shield D-IS Fiber Roof Board D-IS BP -AA BP AA SBS-AA -225.0 C-26 Structural None Min. 2-inch ACFoam II or H-Shield 0.L5 Min. 0.25-inch SECUROCK Gypsum- D-IS APP-TA (Optional) One or more APP-TA -232.5 concrete Fiber Roof Board APP TA C-27 Structural None Min. 2-inch ACFoam II or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum- OB500 BP -AA (Optional) One or more SBS-AA -225.0 concrete Fiber Roof Board BP -AA Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C 28 concrete None Mln.2-inch ACFoam II or H-Shield OB500 Fiber Roof Board OB500 APP-TA APP TA APP-TA -232.5 C 29 Structural None Min. 2-inch ACFoam 11 or H-Shield M-OSFA Min. 0.25Anch SECUROCK Gypsum- M-OSFA BP -AA (Optional) One or more SBS-AA -225.0 concrete Fiber Roof Board BP -AA C-30 Structural None Min. 24nch ACFoam II or H-Shield M-OSFA Min. 0.25-inch SECUROCK Gypsum- M-OSFA APP TA (Optional) One or more APP-TA -232.5 concrete Fiber Roof Board APP-TA Exterior Research and Design, U.C. d/b/a Trinity ( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 a EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 12 of 26 TRINITY 1 ERD ....................F _.; o 'sFR TABLE3A: STRUCTURALCONCRETM CKS NEW CONSTRUMON5RREROOFE(TEAR-0FF) v P .e.. P F P f f - .; r,eesnsan fr=sc}a. �}acy}. of nce�<i« fFrenPrrrrn €f+vrs* xepesn s,°ss 'say Fa aeo-.:rt�P° ra ieYSTEM.TYPEA� BONDED INSULATION�$ONDEO ROOFCOVER ,,� sa a .re xiwK PF }.dR qg} F£F SP .4 F P.. 9 Pk '9 x s.f mss a ""' SEE,NOTEI6 FOR V_APtlIt8ARR1E1t OPTIONS xCFf..s o-4E t£..weffmPQ r„F-fo-s sas raaPf•srcf .. f FaTFfF .fsa•ee.= Fir an�x.Rf.F a •ass: «aaeac.=c f System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck Primer Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min.1.5-inch Ultra -Max or Multi -Max C-31 Structural None FA-3, min. 1.3-inch ACFoam III or min. CR-20 Min. 0.25-inch SECUROCK Gypsum- CR-20 BP -AA (Optional) One or more SBS-AA -225.0 concrete 1.0-inch ISO 95+GL, H-Shield, H-Shield Fiber Roof Board BP AA CG or ENRGY 3 Min. 1.5-inch Ultra -Max or Multi -Max Structural FA-3, min. 1.3-inch ACFoam III or min. Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-32 concrete None 1.0-inch ISO 95+GL, H-Shield, H-Shield CR-20 Fiber Roof Board CR-20 APP-TA APP TA APP-TA -232.5 CG or ENRGY 3 Structural (Optional) Min. 2-inch ACFoam II or H- Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-33 concrete None Shield COlassic Fiber Roof Board COlassic BP -AA BP -AA SBS-AA -225.0 (FULL) (FULL) Structural (Optional) Min. 2-inch ACFoam II or H- OB Min. 0.25-inch SECUROCK Gypsum- OB (Optional) One or more C-34 concrete None Shield Classic Fiber Roof Board Classic APP-TA APP TA APP-TA -232.5 (FULL) (FULL) Structural Min. 1.5-inch ACFoam II, ACFoam III, Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-35 concrete ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA Fiber Roof Board HA BP -AA BP 5BS-AA -225.0 Multi -Max FA3 Structural Min. 1.5-inch ACFoam 11, ACFoam III, Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-36 concrete ASTM D41 ENRGY H-Shield, H-Shield CG or HA Fiber Roof Board HA APP-TA APP TA APP-TA -232.5 a Mu1tFMax FA3 (Optional if (Optional if using AA C-37 Structural ASTM D41 Min. 0.75-inch FesmBoard HA None N/A using AA Ply) Base) One or more BP- SBS-AA, SBS-TA, -277.5 concrete (homogeneous) One or more APP TA BP AA AA or APP-TA Min. 1.5-inch ACFoam II, ACFoam III, (Optional if (Optional H using AA C-38 Structural ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA Min. 0.75-inch Fesco Board HA using AA Ply) Base) One or more BP- SBS-AA, SBS-TA, -290.0 concrete MUltl-Max FA3 One r more o OneBP- AA or APP-TA APP TA (Optional if (Optional if using AA Structural Min. 0.5-inch Structodek High Density using AA Ply) SBS-AA, SBS-TA, C-39 concrete ASTM D41 Fiberboard Roof Insulation HA None N/A One or more Base) One or more BP- AA or APP-TA APP TA -285.0 BP -AA (Optional if Structural ACFoam ACFoam III, Min. 0.5-inch Structodek High using AA Ply) (Optional if using SBS-AA, SBS-TA, C-40 �M D41 EN RGY5-inch hi ENRGY 3, H-Shield, H-Shield CG or HA HA e B Base) One or more BP- -480.0 concrete Multi -Max FA3 Density Fiberboard Roof Insulation One or more AA or APP-TA APP TA BP -AA Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.10.12-112 for FL16027-RZ Certificate of Authorization #9503 a EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 13 of 26 t rTRINITYIERD R F'P RP.RP A. R 4F R P}:y}a P R a.R S P afi eR R Faa Rae } s a e F RR a aae `TABLE3A $TRUCTUR/1LCONCRETE,DECKS NEW CONSTRUCTION ORREROOF(TEAR-OFF) a a a .R ae P a.} IN pRo P a• a }..ea }s R-.. z UU: a".fi aP RR�aar P t c�� aawam® TXPE/f`1.�BONDEDINSUI:ATIIONyBONDEDROQ�COVER }zae F} F r Pan xR-a } Ra'FD as RR xeRarF s} }aRaR Rh a tSYSTEM PmaR a° nae . fiF a� >. a( �eFe ranxr eaese-eRea a:.;�ssae cPPmei- R asRPMra 'RPe,cert:P Ffiaae eaeR a«Fvdea'a a?EE NOTE I6Ffgl'( PjD BARRIEf>r.OPTIONS sna-a ..�usc Ra,. P...,a..R. ..P.., Q.me.carc=..aaa. Fr�r•ss=_. .zaR }.•ee eR?G System Base Insulation layer Top Insulation layer Roof Cover (Note 15) MDP No. Deck Primer Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Structural Min. 1.5-inch ACFoam II, ACFoam III, (Optional if using AA Ply) (Optional if using AA 585-AA, SBS-TA, C-41 ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA Min. 0.25-inch Dens Deck Prime HA One Base) One or more BP- APP TA -480.0 concrete Multi -Max FA3 or more AA or APP-TA BP -AA (Optional if (Optional if using AA F1-41concrete Structural ASTM D41 Min. 0.25-inch Dens Deck Prime HA None N/A using AA Ply) Base) One or more BP- SBS-AA, SBS-TA, -510.0 One or more AA or APP-TA APP TA BP AA .a TABLE36TRUCTURALCONCRETEDECKS aNEW{ONSTRUCiIONORREROOF(TFAR OFF) afi e }PYRa FS }.a aaa a ar' E P�J IIa5}r'F eRir F. } a C Pa ara } tlD�D€ k r } frR t. F F)R E.F n a' MS C RTfiia£4'! F,E SYSTEMTY�EF NON INSULATES BASFSIEET BONDED ROOF�OVER BON_ rfiv.zas} # Roof Cover (Note 15) MDP System No. Deck Primer (Psf) Base Ply Ply Cap Ply C-43 Structural concrete ASTM D41 SBS-SA (Optional) SBS-SA or APP-TA SBS-SA, APP-SA, SBS-TA or APP-TA -315.0 C-44 Structural concrete ASTM D41 BP -AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base) BP -AA or APP-TA SBS-AA, SBS-TA, APP-TA -622.5 Exterior Research and Design, U.C. d/b/a Trin'dy ) ERD Evaluation Report A42970.30.12-R2 for FL16027-112 Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) S16-1485 Appendix 1, Page 14 of 26 QTRINIIY;ERD " s z ° €" sca " "" zsa TABLE 4A.LIGHTWEIGHT,CONCRETEDECKS .NEW CONSTRUCTIONOR REROOE[TEAR OFF)Qa rr z €an' an 4'. amz e e a: z4M° '. a" e z nr x roxa rx as a€ a a r a s€€ - r *: €ar r€zcg+ r a>P n m t ar dz sxvz r z " s e z�a zE��..-.ySYSTE IYPE,A �l BOJ,NDEDIN. >ac ae . F.€s=xaar � r=errn� M' ST E3 € eeAmF€ AP iFn RRF!`__ P fi t e Fg€,., ra. a "' , SULA_T1ON,B0NDEDR00F,C0V_ER".,z € •., - - - System Deck Lightweight Base Insulation layer Coverboard Roof Cover (Note 15) MDP Type Attach Type Attach Base Ply Ply cap Ply No. (Note 1) Concrete (Note 14) (Psf) pSF1F;ADNERING SYSTEMSYVITH.BAS�INSUUAitUN AND,OPTIONAL;iOP INSUlAT10N OFiHESAM'�TYP6 ea €:€ems€s•e•€€a�e.¢•a.�'�'nr -c,�rr €s...Krt az �€e:� a .. €�.es-, rs.�r r€F ss�€cn'a• �: �.n �azr Ursa_ LWC-1 Structural Min. 2D0 psi, min 2- Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 (Optional) Additional OB500 SBS-SA (Optional) One or SBS-SA, APP- -120.0 concrete inch Elastizell layers of base insulation more SBS-SA SA (Optional) One or SBS-SA, APP- LWC-2 Structural Min. 200 psi, min 2- Min.1.5-inch ACFoam II, ENRGY 3, ISO 95+GL OB500 (Optional) Additional OB500 SBS-SA more SBS-SA or SA, SBS-TA -225.0 concrete loch Elastizell or H-Shield layers of base Insulation APP-TA or APP-TA LWC-3 Structural Min. 200 psi, min. Min. 2.0pcf Insulfoam CR-20 (Optional) Additional CR-20 SBS-SA (Optional) One or SBS-SA, APP- -180.0 concrete 2-inch Elastizell layers of base insulation more SBS-SA SA Structural Min. 200 psi, min. Min. 1.5Anch ACFoam II, ACFoam III, ENRGY 3, (Optional) Additional (Optional) One or SBS-SA, APP- LWC-4 concrete 2-inch Elastizell ISO 95+GL, H-Shield, H-Shield CG, Multi -Max CR-20 layers of base insulation CR-20 SBS-SA more SBS-SA or SA, SBS-TA -190.0 FA3 APP-TA or APP-TA Structural Min. 200 psi, min. (Optional) Additional (Optional) One or SBS-SA, APP- LWC-5 concrete 2-inch Celcore or Min. 2.0 pcf Insulfoam CR-20 layers of base insulation CR-20 SBS-SA more SBS-SA SA -222.5 Mearlcrete Structural Min. 200 psi, min. Min.1.5-inch ACFoam 11, ACFoam 111, ENRGY 3, (Optional) Additional (Optional) One or SBS-SA, APP- LWC-6 2-inch Celmre or ISO 95+GL, H-Shield, H-Shield CG, Multi -Max CR-20 layers base insulation CR-20 SBS-SA more SBS-SA or SA, SBS-TA -222.5 concrete Mearlcrete FA3 of APP-TA I or APP-TA ,-------- SELF-ADHERING3YSiEN1�VRRTH BASEaINSUUITNONARID COVE €------- ,«z. �reRae . c za sartt a rr are � r a a az a. _. a ------------- (Optional) One or SBS-SA, APP- LWC-7 Structural Min. 200 psi, min 2- Min. 1.5-inch, min. 2.0 pcf Insulfoam 08500 Min. 0.25-inch SECUROCK OB500 SBS-SA more SBS-SA or SA, SBS-TA -120.0 concrete inch Elastizell Gypsum -Fiber Roof Board APP-TA or APP-TA (Optional) One or SBS-SA, APP- LWC 8 Structural Min. 200 psi, min 2- Min. 1.5-inch ACFoam II, ENRGY 3, ISO 95+GL OB500 Min. 0.25-inch SECUROCK OB5D0 SBS-SA more SBS-SA or SA, SBS-TA -225.0 concrete inch Elastizell or H-Shield Gypsum -Fiber Roof Board APP-TA or APP-TA Structural Min. 200 psi, min. Min. 1.5-inch ACFoam 11, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- LWC 9 ISO 95+GL, H-Shield, H-Shield CG, Multi -Max CR-20 CR-20 SBS-SA more SBS-SA or SA, SBS-TA -180.0 concrete 2-inch Elastizell FA3 or min. 2.0 pcf Insulfoam Gypsum -Fiber Roof Board APP-TA or APP-TA Structural Min. 200 psi, min. Min. 1.5-inch ACFoam 11, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- LWC-10 2-inch Celcore or ISO 95+ GL, H-Shield, H-Shield CG, Multi -Max CR-20 Gypsum -Fiber Roof Board CR-20 SBS-SA more SBS-SA or SA, SBS-TA -222.5 concrete Mearlcrete FA3 or min. 2.0 pcf Insulfoam APP-TA or APP-TA ..... _ _....._ ... .. ASPHALT"AND/OR'TORCHAP£a.,;.;F � •.. - ...',.rFt €€..­ue.€.. ,€z€€. z€ w.... Fa +€...®.seerrosIDYre�€l e, a€ iCeeRS,€8 F'4,.1r _. 4F€4a s.€pspf as g €F'a54 (Optional)One or LWe-11 Structural Min. 200 psi, min 2- Min. 1.5-inch ACFoam II, ENRGY 3, ISO 95+GL OB500 Min. 0.25-inch SECUROCK OB500 BP -AA, mo re BP -AA or APP- SBS-AA, SBS- -225.0 concrete inch Elastizell or H-Shield Gypsum -Fiber Roof Board APP-TA TA, APP-TA TA Structural Min. 200 psimin. Min.1.5-inch ACFoam 11, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK BP �' (Optional) One or SBS-AA, SBS- LWC-12 concrete , 2-inch Elastizell ISO 95+GL, H-Shield, H-Shield CG, Multi -Max CR-20 Gypsum -Fiber Roof Board CR-20 APP-TA more BP -AA or APP- TA, APP-TA _180.0 FA3 or min. 2.0 pcf Insulfoam TA Exterior Research and Design, U.C. d/b/a TrinityI ERD Evaluation Report A42970.10.12-R2 for FL36027-112 Certificate of Authorization N9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (900) 516-1485 Appendix 1, Page 15 of 26 QfiZRINITYIERD F OSOSFSTT EDEC.K'_ NEWCON57RU•Ci IPOfNvfr'oFa Wg't `.air=s�crtseFr-�uRr.enne:ssam pFrs.r:=r«"s)sa°raee`ew.na'wfr"s.::ei5Y5)'EM7YPEAI:EBOjNC1EDINSULQ710N; RRQESR P'kf "PPR Y f'RceEe S OS >. FC 4F t BONDED RQO,FCOVER;. `. "'.P 4C°° '�F°,g" s'F_ gsrvc r�xxsmaP �asscsg FP sac PP smc aF rP+rFe aer, s System Deck Lightweight Base Insulation Layer Coverboard Roof Cover (Note 15) MDP Type Attach Type Attach Base Ply Ply Cap Ply No. (Note 1) Concrete (Note 14) (Psf) Structural Min. 200 psi, min. Min. i.5-inch ACFoam II, ACFoam III, ENRGY 3, Min. 0.25-inch SECU ROCK BP -AA, (Optional) One or SBS-AA,SBS- LWC-13 concrete 2-inch Celcore or ISO 95+GL, H-Shield, H-Shield CG, Multi -Max CR-20 Gypsum -Fiber Roof Board CR-20 APP-TA more BP -AA or APP- TA, APP-TA -222.5 Mearlcrete FA3 or min. 2.0 pcf Insulfoam TA rPUl"M rF eF FM-.: e Frc C A P FF t xFS'YF PiG mtaaa&. -.F sc v'TABLE 4B 11GHTWEIGHTCONCRET�DF..CKS F P P k£ �NEIN CONSTRUCTiON'OR )iEROOF.(TFOFF) -: a ,; •F Et .. .,�n.s.... ...�,...,� .�.F..a4� ry SYSTEMTYP�A2 MECHANICALLY 46 A'[jACHEDAPPCHORSHEEf BONDED:INSULATIOfd�,BONDECI.ROOFCOVER v ' a.�, ,Q,,,� ,,; :IN a �,; Lightweight Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP System No. Deck (Note 1) Concrete (Pstif) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (Note 14) Min. 1.5-inch 7-inch o.c. at (Optional) Min. Thermaroof Composite, (Optional if Min. 22 ga., Type B, Min. 300 psi 4-inch lap and 1.5-inch Polytherm Composite or (Optional if using AA Base) LWC-14 vented steel Approved GAFGLAS OMG CR 7-inch o.c. in ACFoam II, H- HA min. 0.5-inch Structodek HA using AA Ply) One or more 585-AA, SBS- -45.0 at max. 5 ft cellular LWC 475 BSF two, equally Shield, Multi- High Density Fiberboard BP -AA BP -AA or APP- TA, APP-TA spaced center Max FA3 or Roof Insulation or min. TA spans rows Polytherm 0.75-inch FescoBoard (homogeneous) Min. 22 ga., 7-inch o.c. at Min. 1.5-inch Type B, Min. 300 psi 4-inch lap and ACFoam II, H- (Optional) One SBS-SA, APP- LWC-15 vented steel Approved GAFGLAS OMG CR 7-inch o.c. in Shield, Multi- HA None N/A SBS-SA or more SBS-SA SA, SBS-TA -45.0 at max.5 ft cellular LWC g75 BSF two, equally Max FA3 or or APP-TA or APP-TA spans spaced center rows Polytherm Exterior Research and Design, LLC. d/b/a Trinity ) ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization k9503 a EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 16 of 26 �,j TRINITY l ERD r ` tr re g TABLE4C"L)GHTWE(GHTCONGRETEDECK5. NEW CONSTROGTION bit RER270F(TeAR-0FF). ...........r"ex . a s r rr F¢4e3 '£ee F. ea r4 4 � ¢ R$ XY Y Pt.!' AR Er> rrr±:a F .• r >� rear arras eaeamzxv ::mTea rrrreaps e�pevt�aaSYS,TEII{frTY,PEiE..,MkCHANICALLnATT(iCHEDBASESHEEPBONDEDROOF.,fOVER,Fg)Q, Base Sheet (Note A below) Roof Cover (Note 15) System Deck Lightweight Concrete (Note 14) MDP Type No. (Note 1) Fasteners Attach Base Ply Cap Ply (Psf) (Note A) r GENERItti'.CELLULAR _,.. �_. ,., GHt1,NEIG INSUTATINGLbNCRETE L(, tft _. .._ ... _. r_,..._..__... 64-.::,;,,. �nr.msnr .eam....-,:<r, rr-.«.-..,.: r.-: - -.. a £ar¢ .tsar r P- r e vararcce ,era -e ryr..r rro�: rr. rrs• >«r..d.r a>...�m�.. e�Mm,..>„ ,.,,...>.rr• .....r .-x.e..am.....r ta,ceo-maere.aa Min. 300 psi, min. 2-inch thick cellular Min. 22 ga., type B steel LWC. Note: To qualify the LWIC under this 7-inch o.c. in a 3-inch lap and 7-inch o.c. in (Optional) LWC-16 at max 5 ft spans or assembly, an OMG CR BPF shall achieve B3 OMG CR BPF two, equally spaced, staggered rows in the One or more SBS-AA, APP- -45.0 structural concrete an average withdrawal of S3lbf when field of the sheet BP -AA TA tested per TAS 105 orANSI/SPRI FX-1 rCFLCORE CELLULAR L/GFIfWE1GtIffNSUtATIFaG CANCREfE,r e ra. arre¢ -' _. __ .+rrxrr m .erarerrrr�v raa+rr r r r. r ¢ r = ¢r xa m ece =sraaer¢£:e i:pa¢rr rFsaarrr r«¢.>'.ie¢.ear.rr.:g rye=za aim. r•raa¢rrr r,.r .r .: a *r* rrrv. sr ., e Min. 0.0179-inch Tensilform S-75 or min. Trufast FM-90 or 8-inch o.c. in a 3-inch lap and 16-inch o.c. in One or more LWC-17 0.0205-inch Tensilform Min. 200 psi, min. 2-inch thick Celcore BS, B2, B3 or B7 two, equally spaced, staggered rows in the SBS-AA -37.5 75 at max. 5 ft spans or OMG CR BPF field of the sheet BP AA structural concrete Min. 22 ga., type B steel 7-inch o.c. in a 3-inch lap and 7-inch o.c. in LWC-18 at max 5 ft spans or Min.200 psi, min. 2-inch thick Celcore Bl through 332 Trufast FM-90 or two, equally spaced, staggered rows in the One or more SBS-AA -45.0 structural concrete OMG CR BPF field of the sheet BP � Min. 26 ga., type HF 31, B2, B3, 34, 9-inch o.c. in a 3-inch lap and 9-inch o.c. in One or more LWC-19 steel at max 5 ft spans Min. 225 psi, min. 2-inch thick Celcore MF B7, B8, B10, B11 OMG CR BPF two, equally spaced, staggered rows in the SBS-AA -45.0 or structural concrete or B12 field of the sheet BP AA Min. 22 ga., type B steel B3, B2, B3, B4, 7-inch o.c. in a 3-inch lap and 14-inch o.c. in LWC-20 at max 6 it spans or Min. 225 psi, min. 2-inch thick Celcore MF B7, B8, B10, B11 OMG CR BPF two, equally spaced, staggered rows In the One or more SBS-AA -45.0 structural concrete or B12 field of the sheet BP AA Min. 22 ga., type B steel B1, B2, B3, B4, 9-inch o.c. in a 3-inch lap and 9-inch o.c. in LWC-21 at max 6 ft spans or Min. 225 psi, min. 2-inch thick Celcore MF B7, B8, B10, B11 OMG CR BPF two, equally spaced, staggered rows in the One or more SBS-AA -45.0 structural concrete or B12 field of the sheet BP AA Min. 22 ga., type B steel 9-inch o.c. in a 4-inch lap and 18-inch o.c. in One or more LWC-22 at max 5 ft spans or Min. 225 psi, min. 2-inch thick Celcore MF BS or B2 Trufast Twin Loc- two, equally spaced, staggered rows in the BP -AA or APP- SBS-r; SBS-PP-TA -45.0 structural concrete Nail field of the sheet TA TA or Min. 22 ga., type B steel 9-inch o.c. in a 4-inch lap and 18-inch o.c. in One or more SBS-SA, APP- LWC-23 a[ max 5 ft spans or Min. 225 psi, min. 2-inch thick Celcore MF B2 (with poly- Trufast Twin Loc- two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -45.0 structural concrete film top surface) Nail field of the sheet APP-TA or APP-TA Min. 22 ga., type B steel 8-inch o.c. in a 4-inch lap and 8-inch o.c. in BP -AA cr APP- SBS-AA, SBS- LWC-24 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Celcore MF B2 Trufast FM-90 three equally spaced, staggered center rows TA TA or APP-TA -60.0 structural concrete Min. 22 ga., type B steel B2 (with poly- 8-inch o.c. in a flinch lap and B•inch o.c. in One c r more -SA, APP- LWC-25 at max 5 ftspans or Min. 300 psi, min. 2-inch thick Celcore MF film top surface) Trufast FM-90 three equally spaced, staggered center rows SBS-SA or SA, SBS-TA -60.0 structural concrete APP-TA or APP-TA Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report A42970.30.12-R2 for FL16027-R2 Certificate of Authorization #9503 0 EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 526-1485 Appendix 1, Page 17 of 26 � 1 TRINITY I ERD C# b 4 YYY4 P tF tY A# AFF #t ra rrr sFes r c TAHM4cll3GHTWEIGHTiCONCRM-DECKS_ NEWCONSTRUCrIONURREROO "Y F ' . zr t _" Fj(TEAR Off)...xF .F anAt a. r. Fr Yes;'.aa rFs#t .,- 3F•2F?' ASR Tc.9CCi M rEtrC R n¢Fti - n. A�nFrP __ _-._� F# 1FCAPF®. <s t4It�FG a•c+A#s A.r sas.. esc-#e.t Ao#s srsx SYSTENITYPE;E�.MEC)-IAIV)CALI X[ATTACHED,pBA5E5HEET BON,DED�ROOFCOVERps .'�:�t RF hvv'Acr�mr a�TreA#g_* LEa rr +'■ fiFwo#-- ----- Base Sheet (Note A below) Roof Laver (Note 15) System Deck Lightweight Concrete (Note 14) MDP (Psn Type No. (Note 1) (Note A) Fasteners Attach Base Ply Cap Ply Min. 22 ga., type B steel Trufast FM-90 or 7-inch o.c. in a 3-inch lap and 7-inch o.c. in One more LWC-26 at max 5 ft spans or Min. 300 psi, min. 2-Inch thick Celcore 31 through B12 OMG CR BPF two, equally spaced, staggered rows in the A BP AA SBS-AA -75.0 structural concrete field of the sheet Min. 22 ga., type B steel Polyglass 10-inch o.c. in a 4-inch lap and 10-inch o.c. in (Optional) BP- SBS-AA, SBS- LWC-27 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Celcore MF Elastobase Poly Trufast FM-260 three equally spaced, staggered center rows AA or APP-TA TA, APP-TA -9D.0 structural concrete EUlSi1ZElLCEl1SlAR`l1GHiWDGRfJNSUTATWG CONU1Eh ecr e.e. rsr s•ras try �tFr .P. . �a eAt••.p=Fc er. ¢c€!=c a i� 't. RF��_ aRr Cst r.F#.FAr.*�.fiWIM1xgR-�. S6fiCpA • N. t.6'l v:Y 4 #x pCpw £ kAsn n£ r P,e 9FCFFRk Min. 0.0179-inch Tensilform S-75 or min. Min. 200 psi, min. 2-inch thick Elastizell Trufast FM-90 or 7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. One or more SBS-AA, SBS- LWC-28 0.0205-inch Tensilform Range II Bl through B12 OMG CR BPF in two, equally spaced, staggered rows in the BP -AA or APP- TA or APP-TA -30.0 75 at max. 5 ft spans or field of the sheet TA structural concrete Min. 0.0179-inch Tensilform S-75 or min. Min. psi, min. 2-inch thick Elastizell B2 (with poly- Trufast FM-90 or 7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. One or more SBS-SA, APP- LWC-29 0.0205-inch Tensilform in two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -30.0 75 at max. 5 ft spans or Range II a ll film top surface) OMG CR BPF field of the sheet APP-TA or APP-TA structural concrete Min. 22 ga., type B steel Min. 200 psi, min. 2-inch thick Elastizell Trufast FM-90 or 7-inch o.c. in a 3-inch lap and 7-inch o.c. in One or more A, SBS- LWC-30 at max 5 ft spans or Range II Bl through B12 OMG CR BPF two, equally spaced, staggered rows in the BP -AA orAPP- TA or APP-TA TA or -45.0 structural concrete field of the sheet TA Min. 22 ga., type B steel 7-inch o.c. in a 3-inch lap and 7-inch o.c. in One or more SBS-SA, APP- LWC-31 at max 5 ft spans or Min. 200 psi, min. 2-inch thick Elastizell B2 (with poly- Trufast FM-90 or two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -45.0 structural concrete Range II film top surface) OMG CR BPF field of the sheet APP-TA or APP-TA Min. 22 ga., type B steel Min. 350 psi, min. 2-inch thick Elastizell Trufast Twin Loc- 6-inch o.c. in a 4-inch lap and 6-inch o.c. in SBS-AA, SBS- LWC-32 at max 5 ft spans or with Zell -Crete Fibers, supple -mentally B2 Nails (min. 1.8- three, equally spaced, staggered rows in the One or more TA, SBS-SA, -60.0 structural concrete attached with Roofgrip #21 and 3-inch inch) field of the sheet BP -AA APP-TA or plates at 1 per 8 ft2 APP-SA Min. 22 ga., type B steel Min. 350 psi, min. 2-inch thick Elastizell Trufast Twin Loc- 6-inch o.c. in a 4-inch lap and 6-inch o.c. in SBS-SA, APP- LWC-33 at max 5 ft spans or with Zell -Crete Fibers, supple -mentally B2 (with poly- Nails (min. 1.8- three, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -60.0 structural concrete attached with Roofgrip #21 and 3-inch film top surface) inch) field of the sheet APP TA or APP-TA plates at 1 per 8 ft2 aME'ARLUtEfE CFtIL[dRIIGHiWDGt1TIN5UTF1T1}JG�CONCRETEd - err -�Prr �. qx.NIM,*-atYets —MI P Min. 24 ga., type B steel Trufast FM-90 or ruf 7.5-inch o.c. in a 3-inch lap and 10-inch o.c { One more LWC-34 at max 5 ft spans or Min. 200 psi, min. 2-inch thick Mearlcrete 31 through B12 OMG CR BPF in two, equally spaced, staggered rows in the A BP AA SBS-AA -30.0 structural concrete field of the sheet Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.10.12-112 for FL16027-RZ Certificate of Authorization N9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) S16-1485. Appendix 1, Page 18 of 26 �YJITRINITYJERD D m n ar°n nv£s€aa z wno rr"£are r°a s n®" ° rTABLE4C LIGHTWEfGHT"CONCRETE DECKS NEW CONSTRUCT! bRRERO&,ftAROFF) e r oa'€ :g . �. r9 r€ rr -F- T .....,vnt•s�_ n=:R.e.rer' .usr.na€r`:°snF-SZ'SfEM7YPEE'MECHANIW Y'AT7ACHEDBASESHEET;BONDEDROOF.COVER,F.,n F! Se erfe3 4 cn Si ee01[- FaS•n&i6 .. Base Sheet (Note A below) Roof Cover (Note 25) System Deck MDP Type Fasteners Attach Base Ply Cap Ply No. (Note 1) Lightweight Concrete (Note 14) (Psf) (Note A) Min. 22 ga., type B steel 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more LWC-35 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Mearlcrete Bl, B2 or B12 Trufast FM-90 or two, equally spaced, staggered rows in the BP -AA cr APP- SBS-AA, SBS- -45.0 structural concrete OMG CR BPF field of the sheet TA TA or APP-TA Min. 22 ga., type B steel B2 (with poly- Trufast FM-90 or 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more SBS-SA, APP- LWC-36 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Mearlcrete two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -45.0 structural concrete film top surface) OMG CR BPF field of the sheet APP-TA or APP-TA Min. 22 ga., type B steel 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more LWC-37 at max 5 it spans or Min. 300 psi, min. 2-inch thick Mearlcrete B1, 62, B3, 87 or T FM-90 or two, equally spaced, staggered rows in the BP -AA or APP- SBS-A, SBS- -52.5 structural concrete gll OMGMG C CR BPF field of the sheet TA TA or APP-TA Min. 22 ga., type B steel (with po ly- Trufast FM-90 or 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more SBS-SA, APP- LWC-38 ItB2 at max 5 spans or Min. 300 psi, min. 2-inch thick Mearlcrete two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -52.5 structural concrete film top surface) I OMG CR BPF I field of the sheet APP-TA or APP-TA A. Base Sheets options are coded as follows: ➢ Bl: Polyglass G2 Base; B2: Polygloss Elastobase or Polygloss Elastobase Poly; B3: GAFGLAS #75; B4: GAFGLAS Stmtavent Nallable Venting Base Sheet, B5: GAFGLAS Ply 4; B6: GAFGLAS FlexPly 6; B7: JM Perma Ply No. 28; B8: JM Vensulation; 89: JM GlasPly IV; 1310: JM GlosPly Premier, B11: Tamko Glass -Base; B32: Tamko Vapor -Chan Exterior Research and Design, LUG d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6'x EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 19 of 26 ERD TRINITY ! rfar r enca vrcx ca.�"sm ire:ce�a's r �>ci�ar mrsai!DE... d zxm wp sr - s aan F'RRYp. I` R r rare wren xrc e r p p p'C r"rM pRP amx rxe. en��aapxnr-r �p�px rcnxrp rpaTABLESA �CENIENTATICIU5W000 FIBERCKS` NEW C0N57RUCT 0NoR ERO'Oh{ eARaOFF)rcrcp �. er .> y -r�xr znmFae'.rsrp art srr �rcr,:-. ergo w geex art r ffiaetc�s x.pp- «K««a« xis"s:w«a zsr=r'n, .m rzpea`re:sn»°�repem m�an�. is it^�va« .FFSYS E, wR- Eli f3O1VD1E0 LA OF gRxas, pa'aa`x'. m as°wm ss w"=a �cpwxast ;ecr a_sx xpr nxx �x as ppa n«Kmnea.-rtdr T M System Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 1.5-inch ACFoam II, Min. 0.25-inch Dens Deck, Dens Deck Prime, (Optional) One or CWF-1 Min. 2.5-inch Tectum ISO 95+GL, H-Shield, D-IS or SECUROCK Gypsum -Fiber Roof Board or min. 0.5- D-IS or BP -AA more BP -AA or APP- 585-AA, 585-TA, -45.0 plank or Tectum LS Plank Polytherm, ENRGY-3 OB500 inch Structodek High Density Fiberboard Roof OB500 TA APP TA Insulation Min. 2.5-inch Tectum Min. 1.5-inch ACFoam 11, D-IS or Min. 0.25-inch Dens Deck, Dens Deck Prime, D-IS or SBS-SA or (Optional) One or SBS-TA, 5B5-SA, CWF2 Plank or Tectum LS Plank ISO 95+GL, H-Shield, OB500 SECUROCK Gypsum -Fiber Roof Board OBSod APP-TA more SBS-SA or APP-TA, APP-SA -45.0 Polytherm, ENRGY-3 IAPP-TA Min. 1.5-inch ACFoam II Min. 0.25-inch Dens Deck, Dens Deck Prime, (Optional) One or CWF-3 Min. 2-5-inch Tectum, um ISO 95+GL, H-Shield, CR-20 SECUROCK Gypsum -Fiber Roof Board or min. 0.5- CR-20 BP -AA more BP -AA or APP- 58S-AA, SBS-TA, -52.5 Plank or Tectum IS Plank Polytherm, ENRGY-3 inch Structodek High Density Fiberboard Roof TA APP TA Insulation Min. 2.5-inch Tectum Min. 1-5-inch ACFoam 11, Min. 0.25-inch Dens Deck, Dens Deck Prime, 565-SA or (Optional) One or SBS-TA, SBS-SA, CWF 4 Plank or Tectum LS Plank ISO 95+GL, H-Shield, CR-20 SECUROCK Gypsum -Fiber Roof Board CR-20 APP TA more SBS-SA or APP-TA, APP-SA -52.5 Polytherm, ENRGY-3 APP-TA 0 Exterior Research and Design, U.C. d/b/a Trinity ERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization 99503 6ia EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 20 of 26 TRINITY I ERD a rnr"r TABLESB iCEMENTITIOUSWOOE FIBER DECKS NEWCONSfRUCf10N0RREROOF(TEna-0FF) rrs v: nx irvg r. ass 6w "" Fe ,CTE aresfi6l s re case ¢ craasr u . e r as ai srnr aoe;i sm=+ur=o"ee *w�snn GaSYSTEIV). PEQ,2 1)MECHANICALLYATTACHEDQNCNORS"UT BONDED INSULATION;BONDEDRQOFCOVER Frr g Ae�._r _e r Fc. r a . n , .. - - - - -___ --____...----___-- System Deck Anchor Sheet Base Insulation Top Insulation I Roof Cover (Note SS) MDP No. (Note 1) Type Fastener Attach Type Attach Type Attach I Base Ply Ply Cap Ply (Psf) Min. 1.5-inch Min. 0.25-inch Dens Deck, Dens Min. 2.5-inch Polyglass 9-inch o.c. in 4-inch ACFoam II, ACFoam Deck Prime, SECUROCK Gypsum - (Optional) Elastobase, Trufast lap and 12-inch o.c. Fiber Roof Board, Min. 0.75-inch SBS-AA, CWF-5 Tectum Plank Polyglass Inuldek in two, equally III, 15095+GL, H- HA FescoBoard (homogeneous) or HA BP -AA One or more SBS TA, -30.0• or Tectum LS Elastobase Poly, Loc-Nail spaced, staggered Shield, ENRGY 3, min. 0.5-inch Structodek High BP -AA or APP TA Plank Polyglass G2 Base center rows polytherm or Muni- herFA3 Density Fiberboard Roof APP-TA Max Insulation Polyglass 9-inch o.c. in 4-inch Min. 1.5-inch Min. 2.5-inch Elastobase, Trufast lap and 12-inch o.c. ACFoam 11, ACFoam Min. 0.25-inch Dens Deck, Dens S85-SA (Optional) 565-TA, CWF-6 Tectum Plank Polyglass Inuldek in two, equally 111, IS095+GL, H- HA Deck Prime, SECUROCK Gypsum- HA or APP- One or more SBS-SA, -30.0• or Tectum LS Shield, ENRGY 3, SBS-SA or APP-TA, Plank Elastobase Poly, Loc-Nail spaced, staggered poly[ herm or Multi- herFA3 Fiber Roof Board TA APP-TA APP-SA Polyglass G2 Base center rows Max Min. 0.25-inch Dens Deck, Dens Polyglass 9-inch o.c. in 4-inch Min. 1.5-inch Deck Prime, SECUROCK Gypsum- Min.2.5-inch Elastobase, Trufast lap and 18-inch o.c. ACFoam 11, ACFoam Fiber Roof Board, Min. 0.75-inch (Optional) SBS-AA, CWF 7 Tectum Plank Polyglass Twin in two, equally III, ISO95+GL, H-HA FescoBoard (homogeneous) or HA BP -AA One or more SBS-TA, -45.0a or Tectum LS Elastobase Poly, Loc-Nail spaced, staggered Shield, ENRGY 3, min. 0.5-inch Structodek High BP -AA or APP TA Plank Polyglass G2 Base center rows Polytherm or Multi- Density Fiberboard Roof APP TA Max FA3 Insulation Min. 1.5-inch Min. 2.5-inch Polyglass 9-inch o.c in 4-inch ACFoam 11, ACFoam (Optional) SBS-TA, Elastobase, Trufast lap and 18-inch o.c Min. 0.25-inch Dens Deck, Dens SBS-SA CWF 8 Tectum Plank Polyglass Twin In two, equally III, ISO95+GL, H- HA Deck Prime, SECUROCK Gypsum- HA or APP- One or more SBS-SA, -45.0a or Tectum LS Elastobase Poly, Loc-Nail spaced, staggered Shield, ENRGY 3, Fiber Roof Board TA SBS-SA or APP-TA, Plank poly[herm or Multi- her APP-TA APP-SA Polyglass G2 Base center rows Max Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report A42970.10.12-112 for FL16027-RZ Certificate of Authorization N9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 516-148S Appendix 1, Page 21 of 26 �.i TRINITY ! ERD _._,.. .. ....ate.. ...._.,,,_ *' ... .._.0 .-,.. ... ..... ...... } .... p, :R V°# P °C Y F4'C R (°7ABLESC rCEMENTITIOL51fU00DFIBER-DECIfS NEWLONSTRCIGTlON;RERDDF(T&ui:OFF) oit'RECOVEIV,4 "sir s;r"r..gTr*sYrr 'ace:tom°m X.. RYY'F PP r P CYaRc 4 RF!'Cf RBCp:�a*=: rYR°crsae RrcwrnuY 8'4pR Q4Yti!+ wt.P A:Pffi CPR Pa'4AR° Rek .. K.w a!'csNNnte pR'9s 9s mm rnRi rnrs,?f RCIXS9knMYti#!riPX4°@aPp..fl:R4"mga $ _ °aSYCR rnn RwsA%6i PRWW P6° * 3 r€am Y1tY�R MTypE,BPRfft`.TY$rC$r MECHQVICAA„._. HEDRBA.SEIVSUiIATON............... 80)pED) _. 00F8CQVERg°4rfi6ke RR YRRR System Base Insulation Layer Top Insulation layer Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasteners Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 2.5-inch Min. 2-inch H- OMG Polymer GypTec Plate Min. 0.5-inch Structodek (Optional if using AA SBS-AA, CWF-9 Tectum Plank or Shield or with Polymer GypTec or TruFast 1 per 4 ft' High Density Fiberboard HA (Optional if using Base) One or more BP -AA SBS-TA, -45.0* Tectum LS Plank Polytherm TL 3 in. Plate with TL Fastener Roof Insulation Ply) BP or APP-TA APP-TA t rc-e Rrn�° ". r; " °°°, r$r° ,, r �.KTABLESD CEMENT1770USWOOD FIBER:DE,CKS `NEy1f CONSiRUG7ION"RERODF(TeaR:OFF)oaRECOVERx " ° e r e i s a reRSY c r r v ar °r " ' HR * " —A .fd)ECHANI-ALLYATTACHEUI{QSU 1T10N,f10N1]EDjt00FC VE rn` Yk°fR s»..ter.. _,-�rn�. ernrnsffie w,. rns"n�. me <� System Top Insulation Layer Roof Cover (Note 15) MDP Deck (Note 1) Base Insulation Layer Type I Fasteners Attach Base Ply Ply y No. (Psf) Min. 2.5-inch (Optional) One or Min. 0.25-inch Dens Deck, Dens Deck Prime (Optional if using AA F-SO Tectum Plank or more layers, any or SECUROCK Gypsum -Fiber Roof Board or Trufast Twin Loc-Nails 1 per 2 ft' (Optional if using Base) One or more BP -AA rS -45.0* Tectum LS Plank combination, loose min. 0.5-inch Structodek High Density (min. 1-inch embedment) AA Ply) BP AA or APP-TA laid Fiberboard Roof Insulation FF rY°�aa R:RYSR TABLESE CENIENTIT(O(lSfl wo.F(BERDECkS."9NEUUCONSTitI`WIIIdORRER'OOF T¢AW04 "rn ° r ° EC=Ym@rPR 81fe"CPaY4 �r44PR6*YY=°rxm.P.,4S..*P-:6.P..:RF.CFS?C#e.R£s£>4sP,Pfi.FHNrW#'mKr4•R'frRF'�RE �6rsYB`R aR'A xaRNT RR.I".Yu'PrvRP'Ylrrff Ya CR'&REYE"CSsa54 epemp<.@'4 4R*°�$ ra8*a4sf'tWTYE"R rt9ae ttcmP._P FP`r.PFP;ZINN W14— x reffi. SYSTEI�IT'l1rEENON IN5UtATEDMECHgN(CALLATIAGEI�D9ASESFIEET R07QDEDRODCOU Base Sheet Roof Cover (Note 15) Mpp Deck (Note 1) Base Fasteners Attach Base Ply CaP Ply (Psf) E Min. 2.5-inch Tectum Plank Polyglass Elastobase, Polyglass Eiastobase Trufast Inuldek 9-inch o.c. in 4-inch lap and 12-inch o.c. in two, (Optional) One or SBS-AA,SBS-TA, or Tectum LS Plank Poly, Polyglass G2 Base Loc-Nail equally spaced, staggered center rows more BP -AA or APP-TA APP-TA -30.0* Min. 2.5-inch Tectum Plank Polyglass Elastobase, Polyglass Elastobase Trufast Twin Loc- 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, (Optional) One or SBS-AA, SBS-TA,or Tectum LS Plank Poly, Polyglass G2 Base Nails equally spaced, staggered center rows more BP -AA or APP-TA APP-TA -45.0* Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization o9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 22 of 26 -,, TRINI Y I ERD CxRPN pk v rroare e� afiR# @a�Nn Pe N{Y^ F Ya£= W ARP 4FSk B Fe'F'F4'•f ir3•••...n. 6A _X.r1,r.R_tt.rO0 TA"GYP rrc rr Fcr r.LErr %ra'._aa. Frn(TseEA�ar-rt Orx0e aaagscrerceasr re eWr�flreResFs•9a?f�F:StiiKrertksr@.!=.sreEaPSsr rRs� QP rse<Jrofimfl we `" k�'vo„ ewxxcer war rvcsor usece raeAm RPkN#"cUSe;f\xmFwen*�gEraawsea. Eac«nrr.aan rr rrmgwe'm�ra,s€�xR'ca rnme.r:m:,.r6.art e£4:Aa'.aA'(R" rara,s cia £r Fs �eCaeRr .a6GsffCe$�.Q,',fi.t=- RQCOVP9RP5?TEPAI8QNDE,O (NUTIOp;,8Q�DEDFEP�MfrFuiePNffPSR£t Pga�&#RPFPF;1Pt'FW£RF'A �NIPfS`A 9IIDM ffih CE'B WFW:Bifl System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Notes 1 & 12) (PsR Type Attach Type Attach Base Ply Ply Cap Ply Existing, sound poured gypsum (Optional) additional layers(s) of base (Optional) One G-1 or gypsum plank deck Min. 2.0 pcf, Insulfoam OB500 insulation OB500 SBS-SA or more SBS-SA SBS-SA, APP-SA -112.5 (Optional) One Existing, sound poured gypsum Min. 1.5-inch ACFoam II, ENRGY 3 or (Optional) additional layers(s) of base SBS-SA, APP-SA, G-2 or gypsum plank deck H-Shield OB500 insulation 09500 SBS-SA or more SBS-SA SBS-TA or APP-TA -112.5 or APP-TA (Optional) One G-3 Existing, sound poured gypsum Min. 1.5-inch ACFoam II, ENRGY 3 or OB500 Min. 0.25-inch SECUROCK Gypsum- OB500 SBS-SA or more SBS-SA 565-SA, APP-SA, -112.5 or gypsum plank deck H-Shield or min. pcf, Insulfoam fiber Roof Board SBS-TA orAPP-TA or APP-TA (Optional) additional layers(s) of base (Optional) One G-4 Existing, sound poured p gypsum Min. 1.5-inch ACFoam Il, ENRGY 3, M-OSFA insulation and/or min. 0.25-inch M-OSFA SB5-SA or more SBS-SA SBS-SA, APP-SA, -202.5 or gypsum plank deck H-Shield or Multi -Max FA3 SB5-TA or APP-TA SECUROCK Gypsum -Fiber Roof Board or APP-TA Existing, sound poured gypsum (Optional) additional layers of base (Optional) One G-5 or gypsum plank deck Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 insulation CR-20 SBS-SA or more SBS-SA SBS-SA, APP-SA -240.0 (Optional) One Existin& sound poured p gypsum Min. 0.25-inch SECUROCK Gypsum- SBS-SA, APP-SA, G-6 or gypsum plank deck Min. 1.5-inch, min. 2.0 p[f Insulfoam CR-20 Fiber Roof Board CR-20 SBS-SA or more SB5-SA SBS-TA or APP-TA -240.0 or APP-TA (Optional (Optional if using Existing, sound poured gypsum Min. 0.25-inch Dens Deck, Dens if using AA Base) One or SBS-AA, SBS-TA, G 7 or gypsum plank deck Deck Prime or SECUROCK Gypsum- CR-20 None N/A AA Ply) more BP -AA or APP-TA -245.0 Fiber Roof Board BP -AA APP-TA Existing, sound poured gypsum Min. 1.5-inch ACFoam II, ACFoam III, (Optional) additional layers(s) of base (Optional) One SBS-SA, APP-SA, G-8 or gypsum plank deck ENRGY 3, H-Shield, H-Shield CG or CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA or more SBS-SA SBS-TA or APP-TA -257.5 Multi -Max FA3 SECUROCK Gypsum -Fiber Roof Board or APP-TA Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-112 for FL16027-R2 Certificate of Authorization #9503 d EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Mod -flied Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 23 of 26 1 TRINITY j ERD se£ PTABLE6B GYPSUM DECKS REROOF(TF-0FF)nn r . o a a r sn 'r a r n lf.n rPrc. rr+.£ '� nr.-e R r.�x .*..o� •. . +ar.P _ ePrr re IIF C aFrnRR 4r%Fit A F ....e 4.WrrP5�Y5TEMkYPEA2 MECHANICAC�YATTACEav "K EPDI NS ULATr ION''EDO NDEYD4RRO#OiEFfl COVE R EDANCHTR-_sa: r . cnxa€£. h FFnr• fu rcesP -�PW£�. __ _ .c Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP System No. Deck (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) (Note 11) Min. 0.25-inch Dens Deck, Dens Polyglass 9-inch o.c. in 4- Min. 1.5-inch Deck Prime, SECUROCK Gypsum Existing, sound Elastobase, Trufast FM- inch lap and 18- ACFoam II, ACFoam Fiber Roof Board, Min. 0.75-inch (Optional) SBS-AA, G-9 poured gypsum Polyglass 75 or FM- inch o.c. in two, III, 15095+GL, H- HA FescoBoard (homogeneous) or HA BP -AA One or more SBS-TA, -45.0• or gypsum Elastobase Poly, 90 or Twin equally spaced, Shield, ENRGY 3, min. 0.5-inch Structodek High BP -AA or APP-TA plank deck Loc-Nails staggered center Polytherm or Multi- APP TA Polyglass 62 Base rows Max FA3, Density Fiberboard Roof Insulation TABLE 6G GYPSUM DECKStEROOF (TFaa OFF) oR RECOVER a xP £F -. ar r a .... v ■ r SYS' N'#A MECHI�NICAky"'AT[AGI{EDINSULAT)ON BQI�DED�i00FCOVER „m„n ePa! ! s r s ffrlta •�Mpp�� - .�av System Base Insulation Top Insulation Layer Roof Cover (Note 15) - No. Deck (Note 1) Layer (Psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply (Optional) One or Min. 0.25-inch Dens Deck, Dens Deck Existing sound more layers, any Prime or SECUROCK Gypsum -Fiber Trufast Twin Loc- x (Optional if (Optional if using AA Base) One SBS-AA, SBS- G-SO poured gypsum or combination, loose Roof Board or min. 0.5-inch Nails (min. 1 per 2 ft using AA Ply) or more BP -AA or APP-TA TA, APP-TA -45.0• gypsum plank deck laid Structodek High Density Fiberboard embedment) BP -AA Roof Insulation r ews s ! rF:rnq r F r a.` ! - r fa TABLE 6D GYPSUM DECKS REROOF (TEAR OFF) r a !!st^P. s F:a yr '~we r F FrFr a rr c` FF 4 4 r k P£ FN Fri _! ! 4 ff P Ir R BPDl4 R �' rtSystem <F :.r tn'remapsvFn P �,.PSx57E_M,TYPE£,.IVON,INSHLAT,ED .MECHANICALLY,ATiACtiED BASESH..EET,B4OND,ED ROUF�GOVEj�w£,.�ga,;<�,c£,.p„lF�vrrxF=s,s. =`.Ra==war:«:a:lcnn°� Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Base Fasteners (Note 11) Attach Base Ply I cap Ply (Psf) Existing sound poured Polyglass Elastobase, Polyglass Elastobase Trufast FM-75 or FM-90 or 9-inch o.c. in 4-inch lap and 18-inch o.c. in (Optional) One or more SBS-AA, SBS-TA, G-11 gypsum or gypsum Poly, Polyglass G2 Base Twin Loc-Nails two, equally spaced, staggered center rows BP -AA or APP-TA APP-TA -45.0• plank deck Exterior Research and Design, LLC. d/b/a Trinity ( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization 69503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 526.1485 Appendix 1, Page 24 of 26 {_1\ k\j TRINITY { ERD awr .. °xrsr ":ai" a-r'xnwrr re :n .�nee•«.a�ra :4 o wxe�a va_ttr °rr "sr en m°s i''cf Maa'saawa a °�kr�< �a xa aresnxr r;�.`m"s as n.cTABLE;7A ,RECOVERAPPLICAITIONS;r eesAe..s w=Ra sn x r, . . gxa. ss aaer.eR n =.e,a+ x...r.-ua rya rcnr mrraa...asr.,.=..erteass�+e..ssnrarmaweasrrrrw�savnsr a arr ar+e ametaxa a. , r raer•rr x s .e_xsaI os"•esm�."ac=xee�reera�aa`�e�n �,�� a"e� s(SYSTEMjIYPE J}.-1,xBOND,EDINSULATIO,N,°•,80NDED ROQF COVER"." r"a�a�"'""" .r txnwwewaeraexx �aoseegms xea aw�xe_c�� -xex n xxes xx teen System Base Insulation layer Top Insulation layer Roof Cover (Note 15) MDP No. Substrate Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Existing (Optional) additional layers(s) of base (Optional) One or more SBS-SA, APP-SA, R-1 asphaltic roof Min.1.5-inch Multi -Max FA3 D-IS insulation and/or min. inch D-IS SBS-SA SBS-SA orAPP-TA SBS-TA or APP-TA -67.5 er Roof Board SECUROCK Gypsum -Fiber R 2 Existing Min. 2.0 pcf Insulfoam DAS (Optional) additional layers(s) of base D-IS SBS-SA (Optional) One or more SBS-SA, APP-SA -90.0 asphaltic roof insulation SBS-SA Existing Min.1.5-inch ACFoam II or ENRGY 3 or min. Min. 0.25-inch SECUROCK Gypsum -Fiber (Optional) One or more SBS-SA, APP-SA, R 3 asphaltic roof 2.0 pcf Insulfoam D IS Roof Board D-IS SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -90.0 (Optional) additional layers(s) of base R 4 Existing Min. 1.5-inch ACFoam II or ENRGY 3 0.I5 insulation and/or min. 0.25-inch D-IS SBS-SA (Optional) One more SBS-SA, APP-SA, -90.0 asphaltic roof SECUROCK Gypsum -Fiber Roof Board SBS-SA or APP-TA SBS TA or APP-TA R-5 Existing Min.1.5-inch, min. 2.0 pcf Insulfoam OB500 (Optional) additional layers of base OB500 SBS-SA (Optional) One or more SBS-SA, APP-SA -120.0 asphaltic roof insulation SBS-SA R-6 Existing Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum -Fiber 08500 SBS-SA (Optional) One or more SBS-SA, APP-SA, -120.0 asphaltic roof Roof Board SBS-SA or APP-TA SBS-TA or APP-TA Existing Min. 1.5-inch ACFoam II, ENRGY3 or H- (Optional) additional layers(s) of base (Optional) One or more SBS-SA, APP-SA, R 7 asphaltic roof Shield OB500 insulation and/or min. 0.25-inch OB500 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -127.5 SECUROCK Gypsum -Fiber Roof Board Existing Min. 1.5-inch ACFoam II, ENRGY 3, H- M- (Optional) additional layers(s) of base M- (Optional) One or more SBS-SA, APP-SA, R-8 asphaltic roof Shield or Multi -Max FA3 OSFA insulation and/or min. 0.25-inch OSFA SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -157.5 SECUROCK Gypsum -Fiber Roof Board R 9 Existing Min. 2.0 pcf Insulfoam CR-20 (Optional) additional layers(s) of base CR-20 SBS-SA (Optional) One or more SBS-SA, APP-SA -240.0 asphaltic roof insulation SBS-SA R-10 Existing Min.2.0pcflnsulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum -Fiber CR-20 SBS-SA (Optional) One or more SBS-SA, APP-SA, -240.0 asphaltic roof Roof Board SBS-SA or APP-TA SBS-TA or APP-TA Min. 1.54nch Ultra -Max or Multi -Max FA-3, (Optional) additional layers(s) of base Existing min.1.3-inch ACFoam III or min. 1.0-inch (Optional) One or more SBS-SA, APP-SA, R-11 asphaltic roof ISO95+GL, H-Shield, H-Shield CG or ENRGY CR-20 insulation and/or min.0.25-inch CR-20 SBS-SA SBS-SAorAPP-TA SBS-TA or APP-TA 240.0 3 SECUROCK Gypsum -Fiber Roof Board Existing (Optional) additional layers(s) of base (Optional) One more SBS-SA, APP-SA, R-12 asphaltic roof Min. 2-inch ACFoam II, ENRGY-3 or H-Shield CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -247.5 SECUROCK Gypsum -Fiber Roof Board Existing Min. 0.25-inch Dens Deck, Dens Deck SBS- (Optional) One or more SBS-AA, SBS-TA or R-13 asphaltic roof Min. 1.5-inch Multi -Max FA3 D-IS Prime or SECUROCK Gypsum -Fiber Roof D-IS SA APAA SA , APP-TA BP -AA or APP-TA APP-TA -67.5 Board Existing ACFoam II or ENRGY 3 or min. Min. 0.25-inch Dens Deck, Dens Deck BP -AA SBS- (Optional) One or more SBS-AA, SBS-TA or R-14 asphaltic roof 2.0 pcf Insult 2.0 pcf Insulfoam D-IS Prime or SECUROCK Gypsum -Fiber Roof D-IS SA, APP-TA BP -AA or APP-TA APP-TA -90.0 Board Exterior Research and Design, I.I.C. d/b/a Trinity IERD Evaluation Report A42970.30.12-112 for FL16027-R2 Certificate of Authorization #9503 6rx EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 25 of 26 r' �TRINITY!ERD IN" i___ q.y. �r E WRWP PF a'wrK aK tffK@fi. (RECOVERAPPI.ICATIDNSa c'n ax Ate•.. a wa rzrm car W w ..sea rc raw. wras r ear wa raxamr am ssKms Ww rs#a r mar -#aew W tser rrxa ert.a., Y pa^k#*N Y K* Rse rWNPW ..mFF eTABLE*7A ai*4Y «.;#'. Kma RYTflE:w ra ae#eeffiNR&Pmfi 'a Cff^ rsa #S�t�pEa ARMe 4 S#LR1'+'Wta Na P # ° #' 4 9Wffi{R¢ffk#P rcrKK.r#we baF#a'Rkfrfr ERP.43€.! as#sys`# srKssss aa ccYSTrPMryPE/C3 aQA[-'fr9PfiWpoW PksPKiFt&KRFxtl.; WBkFa Fffa,m.K a*a*.. a,9}aiF€,#Q'q PP.rP ra £Fa"B4`�_ 'd14'.#. a BONDEDINS�L{1TlON'BONDED,RCIOFGOVER,g " "H r* ate" 6,., ..-,. . A..FCP85 sI6P@�Y€�P P,*�4�4 E1F 'eERmE'$!6%R15 y6LL9-RGff P•�Kf�i'69 @ 2A. NY System Base Insulation Layer Top Insulation layer Roof Cover (Note 15) MOP No Substrate Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Existing Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield Min. 0.25-inch Dens Deck, Dens Deck BP -AA SBS- (Optional) One or more SBS-AA, SBS-TA or R-15 asphaltic roof or ISO 95+GL OB500 Prime or SECUROCK Gypsum -Fiber Roof OB500 SA, APP-TA BP -AA or APP-TA APP-TA -127.5 Board Existing Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield M- Min. 0.25-inch SECUROCK Gypsum -Fiber M- BP -AA SBS- (Optional) One or more SBS-AA, SBS-TA or -157.5 R-16 asphaltic roof or Multi -Max FA3 OSFA Roof Board OSFA SA, APP-TA BP -AA or APP-TA APP-TA Min.1.5-inch Ultra -Max or Multi -Max FA-3, R-17 Existing min. 1.3-inch ACFoam III or min. 1.0-inch CR-20 Min. 0.25-inch SECUROCK Gypsum -Fiber CR-20 BP -AA (Optional) One or more SBS-AA -225.0 asphaltic roof ISO 95+GL, H-Shield, H-Shield CG or ENRGY Roof Board BP AA 3 or min. 2.0 pcf Insulfoam Min. 1.5-inch Ultra -Max or Multi -Max FA-3, R-18 Existing min. 1.3-inch ACFoam III or min. 1.0-inch CR-20 Min. 0.25-inch SECUROCK Gypsum -Fiber CR-20 APP-TA (Optional) One or more APP-TA -232.5 asphaltic roof ISO 95+GL, H-Shield, H-Shield CG or ENRGY Roof Board APP-TA 3 or min. 2.0 pcf Insulfoam a :: ce rr r r a iABL£7B TtECOVERAPPUCAT10N5 c a ,: a sx *.. n"* `� e (. #a;Ada.a,Sy5T61NTl{PfF.NU�V,ItiSULAT,ED.BONDEDg$,QSESt1EET D;itOOBCOVEfj': KKSK# * B0kw System Roof Cover (Note 15) MDP No. Deck Primer Base Ply Ply Cap Ply (Psf) R-19 Existing ASTM D41 BP -AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base) BP -AA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0 asphaltic roof N' Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.30.12-R2 for FL16027-R2 Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 26 of 26