HomeMy WebLinkAboutTRUSS DRAWINGSL=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
,. TO DETERMINE IF MULTIPLE PLY. ,.
DONT LIFT TRUSSES
WITH SPANS LONGER THAN
39 BY THE PEAK.
CONSULT BCSI
30' SDAn or less
60 degrees
orless
411. 112 aPan
approx.
REFER TO BCSI
Truss must be set this way if core is used.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
Bar
_6 x213 b�.
Tag line V2 of SPan.
REFER TO BCSI
Toss must be set this way it cone is mad.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
n are installed.
w
AIR HANDLER NOTE
nless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
iirements. This may be in conflict with building code and A/C
sign requirements. Consult with Building Department and A/C
Contractor.
WARNING L
size of these trusses makes it necessary that they a sot by a profeesional builder
ar with and experienced in the problems and dangers of setting large span trusses.
builder and erector should consult with an engineer licensed in Florida specializing
od roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
EAT PLATES BY CHAMBERS TRUSS
CORNER DETAIL
Hatch Leqend
PLUMB CUT END
2X4 TOP CHORD
4 WALL HEIGHT 8'-0"
END DETAIL: VAULT
12
PLUMB CUT END
2X4 TOP CHORD
WALL HEIGHT 8'-0"
END DETAIL: TYPICAL
3-1
1�00 00
4r--
61
INDICATES
VOLUME
CEILING
LOAD
BEARING
AT 8'-0"
TRUSSES FOR THE FIRST MODEL SHOULD BE SHIPPED AND SUCCESSFULLY SET BEFORE ANY MORE TRUSSES ARE BUILT FOR THAT MODEL.
Q
Do not stand on
trusses
until they are braced
per BCSI &
properly nailed to straps
and
hangers !!
AARRANGE
WITH
CRANE
OPERATOR IN ADVANCE FOR A STRONG BACK OF 17' -
23'
IN LENGTH!!
SITTING ROOM RIGHT
SITTING ROOM LEFT
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED a RERMED
rhe undersigned acknowledges and agrees:
1. Trusses w7 be made in strict accordance with tits truss placement degran Wimet which is the sole authority for!
Wh8muning sucoesstul fabrication of the trusses,
2. At dimensions in this layout have been verified by the wndresgned.
3. Unless widen notice is provided by cerifiecl mad to Chambers Truss within fen (10) days of dePivery that
[4,
signed agrees that no badcdrages will be allowed. In the event such wrilleh voice is famished Chambers Tess ,
have twee (3) lnsiress days in which b begin repairs requited, of b substitute other trusses. at Chambers option, j
10 days d delivery remedy w7 be aka 6 g to Florida st�de 5511 i
The undersgned adkowledges receipt of'BCSP summary sheet by TPI d WtCllole athority determine the suitabrdy of5. Delivery is to job site. It is the buWs �slle oto rsaportion d trejo the job sle � jor� delivery. Chambes Tess Ivy t
sponsible fa dung deivery only. The buyer is tespo sbl t for additional - Chandialsf hambers Tess drusts has
deliver because job site s not prepared for delivery or buyer is not prepared br delivery of tnsses.TBuyer is
eSpOnSible b Chambers Tess for bnv costs due to site calhd6ols.
6. Price as sham in paragraph 7 below is subject to change I any changes are made in this layout A $50 per hour!
ae for revisions may be charged by Chambers Tess.
7. The is a PURCHASE ORDER to Chambers Tess Of the sum agreed b, or I no agreement a reasonable price.
voice will be made on delivery and paid within fems of net on delivery. Invoice miry be (made at scheduled dale of:
killivery I buyer cannot accept delivery of fabricaled trusses The undersigned agrees to pay Chambers Tess!
easonable atbmeys fee for collections in event of payment not timely made. 142 % per month service charge will be
idded for all suns not paid within terms.
8. Signature or niiak anywhere on this sheet constitutes; agreement to at toms herein
9. In consideration of Chambers Tess extending credl for this material the undersigned unconditionally giraaMees :
virment when due of arty and all indebtedness owed to Chambers Tess by any entity receiving material and the:
nMsigned agrees b pay such indebtedness inducting attorneys fees. I dated in palehent for maerial be made by the
ecipient
10. In the event of any litigation oahcerning this agreement, the 'dens hxnished hereunder or payments reki ed b
well. Me parties agree flat the sole veare for any such action will be Sant Lu9e County. Forda.
11. Design resporsbites are per ""National Standard And Recommended Gddeihes On Reepersbilifies For j
USIN Metal Plate Connected Wood Tosses ANSIRPtWTCA 4 - 2002"" i
12. Warranty is per Chambers Tess Warranty attached.
ATED
IGNED i
OR TITLE_
I
A spreader bar may be required per to prevent Injury & damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and permanent bracing are required and can save life and property
and is the responsibility of the truss erector. i
Study the contents of the information packet included on delivery before
setting trusses. 1
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set and square
®
®
Do not set bunks or stack of p yl wood, roofing material or any other
concentrated loads on trusses, this can Muse collapse.
DO NOT INSTALL TRUSSES USING 710S
USE PLAN DELIVERED WITH TRUSSES TO SEr TRUSSES
CHAMBERS TRUSS INC
31050
n venue i
Fort Pierce, Florida 34982-M
800-551-M
Fort Pierce M 465-2012 Fax 772.465.81"11 i
Vero Beach M-569-2012 Stuart Tr•288-3;i02 j
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COIII i
e
-' ' ..•cc s representati,
shop drawi,. proval is NOT a
"double cheer. :J the contractor.
The contractor shall remain responsible
for checking field measurements and
other construction criteria. Architect`s
approval covers general roof shape,
review of truss strapping, and loading on
structure from 9ra ity and uplift loads am
their re Live Iota {o
- .... Approve
Date: —
B Idero t: Sweden A.i.A. p.a.._ -__-
.e.t.
tl]Nk"AXSM CRITEM REOIICwtE
PER CCOE SUCH w4 Sec 1e0s w/
DESIGN CRITERIA
County ST. LUCIE
Building Department ST. LUCIE COUNTY
Wind Design Criteria ASCE 2010
Wind Design Method MWFRS(DirectonaW" hybrid wind ASCE 7-10
Roofing Material Shingle or Shake
Loading in PSF Roof R.D.L. Floor
Top Chord Live 20 0
Top Chord Dead 7 42 0
Bottom Chord Live •10-Non Conoauent 0
Bottom Chord Dead 10 3 0
Total Load 47 72 0 i
Duration Factor 125 0 i
Wind Speed 165mph i
Top Chord C.B. Sheathing by builder
Bottom Chord C.B. Sheathing by builder
Highest Mean Height 15'
Building Type Enclosed
Building Category It: Non Restrictive
Exposure Category C>Open Terrain with scattered obetrted ons
Miles from Ocean 5 +
Confomhs to Florida Building Code 2017 i
R.D.L. Restraining Dead Load C.B: Continuous Bracing
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer andlor Engineer of Record i
--------------------
Chambers Truss Inc. Drawing Name: M11422
SCALE: 1/4" = V-0"
84 total trusses, 16 unique designs j
Designer. RLC Reviewed by: RLC 7 5a al j
Date: 06/20/18
FOR 49 �G5 Ca5iIC45
WYNNE DEVELOPMENT
DESCRIPTION:
MAJESTIC/ 2 CAR/ ENCLOSED REAR
PORCH
Page 1 of 1 CUSTOMER INITIALS EACH PAGE
M11422