ST. Wele tqun%y,.pArmitWr
SF x 8VA Living Only I 0 D
(2) Small appliance ckts @ 1500VA each
RefTlgarator @ IS00 �S U �0----�.+
Refi'Igerator @SSOo �--
Freezer @ 1500
Washing Machine @ 1500
Dishwasher @ 1500 \ ti ��� O
Disposal @ 1500 ST•LUCIECOUN7Y l��__
Mini sewer @ 150o PEaly� W L d��
Clothes Dryer @ Soco a
Range @ 12000 BLDG: - D 5
Water heater @ 4S00 DATE :1"--<L..
Fixed microwave @ 1500
Vacuum @ 1500 ELE�! �Od
Trash Compactor @ 1500 DATE:
Pool Heater @ lname-plate' PLUMS. =
spa @ 'nameplate? DATE �� a
Motors 746VA per HP DECK:
Garage Door opener DATE
_
r
1) Total
2) First 10 KVA of general load (op 1D0°lo
3) Subtract iine-2 froln 1
4) Multiply line 5 @ 40%
s) Add lines 2 and 4
6) 60/50arnp breaker for heat (1000o)
7) 40/SOamp breaker for heat (5oo0)
B) Total heal Add lines 6 and 7
9) Multiply, line 8 @ 65%
10) Add lines 5 and 9
11) Divide line 10 by 240
summary;
Line 10 Is the total KW
Line 12. is the total Amps
- oa
U
� u _N.6
-..._._, 0 DOU
� � � � 0 {Qene�afiorSlze
(Breaker size