BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
119 Permit #: ( 1 - 0 6 Y-
ILf4-gt �j,Fi-,,,,f Avt,
New Construction - Complete
3LF
RECEIVED
APR - 0 51 2019
Permitting Depaitm
St. Lucie Count
( ) Existing —After Addition
Housf Infiltration Test Results SLC Climate Zone 2 r
CFM (0) = l o 3 0 Test Date: Y-I ( It I
Volun ifie = I I S 6 A -
ACH ( 0) = CFM (50) x 60 / Volume =
Passing results must be & ACH (50) or less
Mechanical Ventilation required less than 3 ACH
('Pass ( ) Fail
FBC, Enrgy
The bui ding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower oor at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third parry. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressur of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dw `ling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Comaanv
Comparl�r Name: Pro -Duct Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereb�iIIcertify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirerihents in accordance with Section R402.4.1.2 Climate Zone 2.
i
Signatu i
�I
Printed Oame: Martin Klein
#: 5061633
o' Cl\
rs of South Florida
illation Certificate
Date: March 13, 2019
Lot/Block:
Project:
stalled in the above described nronerty as follows:
1. Exterior CBS walls have been insulated with:
Spray -on Cellulose
Thickness in inches:
Fiberglass Blankets
Manufacturer:
Fi Foil
Rock Wool Blankets
Density:
X
Aluminum Foil
R Value:
R 4.1
Rigid Board
Polystyrene
Other
2. Ceilings (level) have been insulated with:
Spray -on Cellulose
Thickness in inches:
11.1"
X
Fiberglass Blown
Manufacturer:
Climatepro
Rock Wool Blankets
Density:
Aluminum Foil
i R-Value:
R-30
Polyurethane
Open Cell SPF
Ceilings (Inaccessible) insulated with:
Spray -on Cellulose
Thickness in inches:
9.5"
X
Fiberglass Blankets
j Manufacturer:
Johns Manville
Ignition Barrier
Density:
Fiberglass Blown
R-Value:
R-30
Cellulose Loose Fill
Open Cell SPF
3. Interior kneewalls have been insulated with:
Fiberglass Blankets
Thickness in inches:
Fiberglass Loose Fill
Manufacturer:
Rock Wool
Density:
Fiberglass Blown
R Value:
Cellulose Loose Fill
Open Cell SPF
4. Garage partition walls of A/C living area have X Fiberglass Blankets
been insulated with:
lRock
Wool
Thickness in inches:
3.5"
Polyurethane
Manufacturer:
Johns Manville
Spray -on Cellulose
Density:
Open Cell SPF
R-Value:
R-11
5. The following have been insulated:
� s
�+s� ' �j iA1�T� %�•�i
Ste• a
w SE
y- : 2003 '.°•
�. ss
''�'•.o�p'• OT��•• °'
, Is1 O1Rf s'°
�
VVYNNU BUILDING CORP.
General Contract/Builder
CBC1254041
Competency #
Professional Insulators of South Florida, Inc.
Insulation Contractor
By: By: