Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEI "FORM R405-2017 SCANNED FLORIDA ENE.Rt.PQUAf�CIENCY CODE FOR BUILDING CONSTRUCTION Y' IFlorida Department fBusiness and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Stre -z'skcI N�kL-+-es Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Own �r: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Desi In Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) I 1. Nevi construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Sin I� le family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 1 b. Frame -Wood, Adjacent R=11.0 192.00 ft2 3. Nu ber of units, if multiple family 1 c. N/A R= ft2 11 4. Nur ber of Bedrooms 2 d. N/A R= ft2 11 10. Ceiling Types (1446.0 sqft.) Insulation Area 5. Is tt ,�s a worst case? Yes a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Co 'ditioned floor area above grade (ft2) 1446 b. N/A R= ft2 Co (ditioned floor area below grade (ft2) 0 R 11 Ducts R ft2 7. Wirldows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. uL Factor: Sgl, U=0.36 101.25 ft2 HGC: SHGC=0.25 b.li Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency C: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 C.. ctor: N/A ft2 EC: 13. Heating systems kBtu/hr Efficiency d. L Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 GC: Area Weighted Average Overhang Depth: 3.832 ft. AreE Weighted Average SHGC: 0.239 14. Hot water systems a. Electric Cap: 40gallons 8. Floor Types (1445.5 sqft.) Insulation Area a. Slab Edge Insulation R=0.0 1445.50 ft2 -On -Grade b. Conservation features b. Ny, - R= ft2 None c. NIA R= ft2 15. Credits Pstat Total Proposed Modified Loads: 47.17 Glassil Area: 0.098 PASS ;(Floor Total Baseline Loads: 48.08 ; i T$E ST,q?, I hereby certify that the plans and specifications covered by Review of the plans and this ca dulation are in compliance with the Florida Energy _ specifications covered by this Code. � -0�, calculation indicates compliance y ri;, '=.=�,�� o. with the Florida Energy Code. ti mn,"�; .°; �;°•� . ���� O PREP R D BY. Before construction is completed r 4 0 ^' DATE this building will be inspected for { compliance with Section 553.908 * I hereby the certify that this building, as designed, is in compliance Florida Energy Code. Florida Statutes. y� COD with WE'i¢� UVVNIH3 BUILDING OFFICIAL: DATE' d DATE: 11 - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certi led factory -sealed in accordance with R403.3.2.1. - Com IHance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelo; a leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/17/ 018 3:41 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 I FORM �� - R405-2017 PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Buildi g Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subd!vision: # of l nits: 1 Worst Case: Yes PlatBook: Build r Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Perm i Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Juris action: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, FamiW Type: Single-family FL, New/ New (From Plans) Com i ent: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 I 90 70 75 299 62 Low BLOCKS Nu 6er Name Area Volume 1 I Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 I BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio I BEDROOM 52 ft 0 301 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ---- 0 1 0 4Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0 �i 6 Slab Edge Insulatio BEDROOM 2 32.2 -On -Grade ft 0 203.5 ft2 ---- 0 1 0 I 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 ---- 0 1 0 4/17/1" 018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FnFAA idnr,-7n17 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft I 0 42 ft2 --__ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 -_-- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 �j 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation i Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood i 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Ext InsiHEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext Ins1HEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InsfflEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 _ 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 _ 6 NE=>SW Exterior Concrete Block - Ext InQEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext ImEEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext In!flEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext Ind3ffDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 1 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 1, SW=>NE Exterior Concrete Block - Ext InsillAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 1 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 1 NW=>SE Exterior Concrete Block - Ext In--GREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 1 I N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 I I i 4/17/ 018 3:41 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FnRM 4(l5-gf117 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. I Wall # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 0.36 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in 0.36 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in 0.36 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in 0.36 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 i GARAGE I # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315ft2 315ft2 24ft 8ft 11 INFILTRATION # Scope Method Iiolehouse SLA CFM 50 ELA EgIA ACH ACH 50 1 W Proposed ACH(50) .000356 1349.6 74.09 139.34 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ I Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 j HOT WATER SYSTEM I # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 4/17/�,018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 I'Ln.r-,-qn17 Pori 1A DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ftZ Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 j TEMPERATURES Progi mable Thermostat: Y Ceiling Fans: Co oli Heati 'I [ Jan p f X� Jan Feb Feb Mar Mar A r Apr May May Jun Jun rl Jul Jul rl Aug Aug rl Se Sep Oct Oct Nov Dec Dec [[ Jan Feb X Mar Jun Jul Aug Sep X Nov DecVenti Therm stat Schedule: HERS 2006 Reference Hours Sched e Type 1 2 3 4 5 6 7 8 9 10 11 12 Coolin (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Coolin (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heatin (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heatin I (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/1 N018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 .201 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA P oject Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. S reet: Permit Office: ST. LUCIE COUNTY C y, State, Zip: FT. PIERCE, FL, Permit Number: O ner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY D IISign Location: FL, Fort Pierce COMPONENT I AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA Gen gal A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requi ements Breaks or joints in the air barrier shall be sealed. Ceilii!i� The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit g/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Wall The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Wind �ws, skylights The space between window/doorjambs and framing, and and oors skylights and framing shall be sealed. Rim j�l ists Rim joists shall include the air barrier. Rim joists shall be insulated. FloAl The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (incl 'ding insulation. maintain permanent contact with"the underside of abov °i garage subfloor decking, or floor framing cavity insulation and ntilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Craw, space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shaft penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Rece lsed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plum ding and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind popung and wiring, Show r/tub 'erior The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall one wall tubs shall separate them from the showers and tubs. be insulated. Elect gcal/phone box or The air barrier shall be installed behind electrical or communication exten �r walls boxes or air -sealed boxes shall be installed. HVA4 register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Conc lI led When required to be sealed, concealed fire sprinklers shall only be sprin hers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates ancl walls or ceelonas- a. m a unwn, mspecuon or log walls snail De in accoraance wan the provisions of IGG-4UU. 4/17/2 8 3:41 PM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 i i y FOR 1 R405-2017 1. New 2. Sing 3. Nurr 4. Nurr 5. Is th 6. Coni 7. Win( a. U b. U S c. U S d. U S Area Area 8. Floo a. SI; b. N/ c. N/ ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. FT. PIERCE, FL, -onstruction or existing family or multiple family )er of units, if multiple family )er of Bedrooms s a worst case? itioned floor area (ft2) Dws** Description Factor: Sgl, U=0.36 IGC: SHGC=0.25 Factor: Sgl, U=0.65 IGC: SHGC=0.21 Factor: N/A :actor: N/A IGC: Neighted Average Overhang Depth: Neighted Average SHGC: Types b-On-Grade Edge Insulation New (From Plans) 9. Wall Types Insulation Area a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 Single-family b. Frame - Wood, Adjacent R=11.0 192.00 ft 1 c. N/A R= ft2 2 d. N/A R= ft2 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1446.00 ft2 1446 b. N/A R= ft2 c. N/A R= ft2 Area 11. Ducts R ft2 101.25 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 250 40.00 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 34.8 SEER:15.00 ft2 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 3.832 ft. 0.239 Insulation Area 14. Hot water systems Cap: 40 gallons R=0.0 1445.50 ft2EF: a. Electric 0.97 R= ft2 R= ft2 b. Conservation features None 15. Credits Pstat I certify hat this home has complied with the Florida Energy Efficiency Code for Building Constru'' tion through the above energy saving features which will be installed (or exceeded) in this home �i before final inspection. Otherwise, a new EPL Display Card will be completed based o installed Code compliant features. Builder gnature: Date: Addres of New Home: City/FL Zip: J o� oiE SpgT�o 14. �oD WE °y *N te. This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mo'! gage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at tec support@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of ce ified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Co mission's support staff. I required by Section R30S1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/2018 3:41 PM EnergyGauge@ USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 wrightsoft Project Summary Enure House • QUICK CALCS, INC. 311/1ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALcs(4?40L.00M For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: Weather. Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration Job: Date: By: Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data Ratelswing multiplier n 0.95 Equipmenf sensible load 24753 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh Area Heat' . Cool' (none). (ft2) 1446 1446 Equipment latent load 5521 Btuh Volume (ft3) 12511 12511 Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh Equiv. AVF (cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25H BC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Airflow factor Static pressure Space thermostat Capacity balance point = 32 OF Backup: 8.5 HSPF 34600 Btuh @ 47OF 27 OF 1160, cfm 0.049 cfm/Btuh 0.50 in H2O Input = 7 kW; Output = 23009 Btuh, 100 AFUE Calculations Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling . 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 byACCA to meet all requirements of Manual J 8th Ed. + wrightsoft` Right -Suite® Universal 2017 17.0.14 RSU08101 ...uick Calcs%Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N 2017-Apr-11 09:29:38 Page 1 I i� i wrightsoft Right-JO Worksheet Job: Entire House Byte: QUICK CALCS, INC. I 317 SST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/10L.COM Room name Entire House BEDROOM Exposed will . 156.2 ft 49.0 ft Room height 8.7 ft d 8.0 ft heat/cool Room dimensions 1.0 x 297.0 ft Room area 1445.5 ft2 297.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Stuh/ft2-°F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat cool 13A 4ac§; >0143 n .: 4 C6 2:55 503 465 . 1862 1184 72 72 i286 983 4A5 tom' 0.770 n ". 21:56 1931 : -38 0 . 815 ; 730 ` 0 0 . . l 13A-0ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 I-G 1A-c1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 �D 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W- ' : ` '13AAocs 0:143 se 4.00 2.55 34 34 136 86 0 0 0 : ' ' 0 13A-4ocs 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 _ 550 �G 1Ao1om 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 v��/---G 0143• w 4.00 .55 310 237 603 104 72 288 18313A-4ocs 1Ac1om 1.270 w 35.56 .55.21 - 32 2 1140. 1770 32 2 1140 1770. r0.Tf0 : w 21.56 19.31 i ,: 41 . 4.1 : 880 786 >- p p I: 0 ... D P 12C-0sw 0.091, - 2.55 1.26 192 192 489 246 0 0 0_ 0 C ', 16A 30md " .-: - '0.032 `= 0.90 . 232 ` 1446 ,. 1946 -, 1295 _ ` 3354 r ..:. 297 . 297: - , 266 689 F 22A-tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 T. 0 6 c)AED mursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 p Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less wdemal load 0 0 0 0 Lessaransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 6053 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 Total room load 23503. 26056 6653 7325 Air required (cfm) 1160 1160 ' 328 326 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -- wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38Page ..uick CaIcs1Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N 1 i I l i wrightsoft' Right-M Worksheet Job: Entire House ay. QUICK CALCS, INC. 317 i�ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@/\OL.COM Room name WIC KITCHEN Exp6sed wall 0 ft 0 ft Room height 8.0 ft heat/cool 8.0 ft heat/cool Room dimensions 6.0 x 9.0 It 1.0 x 172.0 ft Room area 54.0 ft' 172.0 ft2 Ty Construction U-value Or HTM (ft) Area ' Load Area (ftj Load number Btuh/ft2-°F ( ) 2 (Btuh/ft) or perimeter (ft) (Btuh) or perimeter' (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool V�/ 13A�ocs.; 0143 n 400 2;55 0 0 : 0:. 0.: 0 0 0 <-0: G. i4A5 tom O T/0 fi' 21 J56 1931 0 0 .., ;' ; 0 " - 0 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 a 35.56 87.29 0 0 .0 0 0 0 0 0 1! 11DO ' 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 °13A4ocs .. 0.143 , se . 4.00 2.55 0 0 . 0 . 0 0 0 U :0 t13A4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 -G 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 V 13A-0oc"s 0.143 w' . ` 4.60 '2.55: 0 0 0 .0 0' 0 0 0 �' r, Ez 1A�1om - 1.270 w 35.56 55:21 0 0 0. 0.: 0 . 0 0 0 -.4A5 tom . .0.770 w 21.56 1931 0 . 0 0 .0 0 0 Of 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82 C 16A 30md .. 0.032 ,; ' _ .0 90 239 : ..54 , • 54 - 48 ; : , '125 - , .172 .: ; 172 :- 154 F I I, 22A tpl 0.989 - 27.69 0.00 54 0 0 0 172 - 0 0 0 T. 6 c)AED excursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 p Appliances/other 0 20M Subtotal (lines 6 to 13) 48 117 .317 . 2311 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 Subtotal 48 117 317 .0 2311 15 Duct loads 32% 49"/6 15 57 32% 49% 100 1126 Total room load 64 174 418 3437 Air required (cfm) 3 8 21 153 Calculations approved by ACCA to meet all requirements of Manual J-8th Ed. wrightsoft- 2017-Apr-11 09:29:38 RightSuite® Universal 2017 17.0.14 RSU08101 .4a Page 2 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup . Calc = MJ8 Front Door faces: N I . wrightsoft Right-M Worksheet Job: j Entire House By`e7 QUICK CALCS, INC. 31 1ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fa)c 772-466-6796 Email: QUICKCALCS@A0L:COM Room name BATH BEDROOM 2 Exposed wall 5.0 ft 34.2 ft Room height 8.0 ft heat/cool 8.0 ft heat/cool Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 ft Room area 45.0 ft2 203.5 ft2 Ty Construction U-value. Or HTM Area (ft-) Load Area (ft-) Load i number (Btuh/ft2-"F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Coal 13A-4ocs .. 0143 , n;' 4.00 2.55 40 :. 40 160 - 102 : 128 ,- 928 513 326 0.770 , nr 21 56 19.11. 0 . ` 0 : ' 0 0 0 0 .. 0 : 0 13A4ocs 0.143 a 4.00 2.55 0 .'' 0 . 0 0 86 56 225 143 �G 1A-c1om 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 1 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W ,:13A4ocs 01143 se 4.00 2.55 0 0 0 0 34 -34 136 86 W 13A�4ocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81 -G IA-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-4ocs ' .0143 w 4.00 2.55 0 0 0 0 0 0 0 0 9Ac1om . 1.270 w 35.56 55.21 0 0, 0. 0. 0, 0 0 0 .0.770, , ;w 21:56 1931 _ 0 : 0 0 "0 0 .. ' 0 0 U- P 12C-0sw 0.091 -- 2.55 1.28 0 0 0 0 0 0 0 0 C 16A 30md ':.. 0.032 .. - ._ .:0.90 232 .. 45 : 45 :.. 40 _::: 104 ;.:. . ' 204 .: <204 .1.82 472 F i I, 22A,tpl. 0.989 27.69 0.00 45 5 138 0 204 34 946 0 I - I , F c)AED excursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration 87 24 593 162 b) Room ventilation 0 0 01 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal pines 6 to 13) 425 214 3571 3498 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 151 Duct loads 32% 49% 135 104 32% 49% 1131 1704 Total room load 560 318 4702 5203 Air required (cfm) 128 14 232. 232 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -- wrightsoft' 2017-Apr-11 09:29:38 A Right -Suite® UniversaL2017 17.0.14 RSU06101 Page 3 ! ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJB Front Door faces: N i I •i' I wrightsofir Right-M Worksheet Job: Entire House bate: By: QUICK CALCS, INC. 3171 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466 6796 Email: QUICKCALCS(}10L.COM Room name LAUNDRY GREAT/DINING Eosed wall 6.0 ft 47.0 ft Room height 8.0 ft heat/cool 9.8 ft heat/cool Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft 41. Room area 42.0 ft2 526.0 ft2. Ty . Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2--°F) (Btuh/ft2) or perimeter (ft) (Btuh). or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Coot Gross N/P/S Heat Cool I V�1 p p ` y 255 , 217, 869 552 I--G :4A5 toms 0.77.0 n 21;56 19:31 p p 36 ' ' 0 815 730 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 TL13A-4ocs _3D 1Ao1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W A3A1Aocs 0.143 se 4:00 2.55 0 0 0 0 0 0 0 0 t-G 13A4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 ` 206 165 . 661 420 1Ac1om' - 1 270 ` w 35.5Ei. 55.21 0 0 0. : 0 0 . .p' ,0 0 4A5-2om: ` 0 770 ,.-w : 21:56 19:31 0 p ; 0 p " 41' ' . 41 , 880 '788' P 12C_0sw 0.091 2.55 1.28 56 56 143 72 0 0 0 0 C _ 16A 30m1i, : 0 032 ::. _ 0;90 2:32 `. _ 42 .: 42 ... " 38 :' .: 97 - : 526 :: °' 526 . 471 >1220, F, I 22A tpl :.. 0.989 - 27.69 0.00 42 6 166 0 526 47 1302 ., . . 0 6 c)AED excursion -jl 668 Envelope loss/gain 539 276 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal Qines 6 to 13) 643 298 5994 5112 Less extemal-load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 32% 49% 204 145 32% 49% 5994 1899 5112 2490 Total room load 846 7892 7602 Air required (cfm) 0 390 338 Calculations approved b ACCA to meet all re uirements of Manual J 8th Ed. wri htsoft• �9 Right -Suite® Universal 2017 17.0.14 RSU08101 � 2017-Apr-11 09:29:38 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 4 T I I Job: wrightsoft, Right-J.® Worksheet Entire House Bate` y QUICK CALLS, INC. 31 ;,ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM Room name FOYER M. BATH Exposed wall 7.0 ft 8.0 ft Room height 8.0 ft heaticool 8.0 ft heat1cool Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft Room area 50.0 ftz 56.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool I i 13A-0ocsr: 0143 n: 4:00 255 8 8 32 20:; 0.. 0 0 '0 0.TI0 n 21 56 19.81 0 0 0 0 ' 0, 0 13A-4ocs 0.143 a 4'00 2.55 48 27 108 69 0 0 0 0 71 1A-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 1 --DDD 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W• ` .13A-46cs 0.143 se .4.00 2.55 0 0 0. 0 0 0 0 :. 0 V�/ 13AAocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 a 1Aclom 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 13A-46cs 0143 w 4.00 2;55 0 0 0 .0 0 0 10 0' 1A c1om 1270 w 35.56 55:21 0 0 0 0 0 0 0 0 4A5,2om :. 0 770 :w:. 21 56 . 19 31. , 0 ,: 0 ; 0 :. 0 - . 0 ' 0 : 0 < 0. P_ 12C-0sw 0.091 - 2.55 1.28 , 72 72 183 92 0 0 0 0 Cz , ' :.16A-30md ,' - 0.'032 : - :. 0 90, 2.32 . - : 50 .: 50 ` - 45 116 .. .56 .. 56 :;50 13U F I I I 22Prtol 0.989 - 27.69 0.06 50 7 194 _' 0 56 : 8 222 0 6 c)AED erxursion -39 �8 Envelope loss/gain 792 4961 747 478 12 a) Infiltration 121 88 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 913 529 885 516 Less wdemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 32% 49% 289 258 32% 490/6 280 251 Total room.load 1202 787 1166 768 Air required (cfm) 59 35 58 34 I I Calculations approved b ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2017-Apr-11 09:29:38 r GA Right -Suite@ Universal 2017 17.0.14 RSUD8101 Page 5 i ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJB Front Door faces: N Duct System Summary Job: wrightsoft y Date: Entire House By: QUICK CALCS,INC. ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL nal static pressure lure losses able static pressure y / return available pressure st friction rate il air flow effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O *0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk �Tt+ h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 st1 EDROOM 2 h 4702 232 232 0.360 7.0 OxO VIFx 23.9 115.0 st1 EDROOM-A h 3327 164 163 0.300 6.0 Ox 0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 IfOYER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0 GIREAVDINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 REAVDINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 136.0 st2 ITCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 st1 UNDRY h 846 42 20 0.361 4.0 Ox 0 VIFx 23.3 115.0 st1 BATH -A h 768 58 34 0 0 OxO VIFx 0 0 lllc c 174 3 8 0.309 4.0 Ox 0 VIFx 27.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 1✓inlFlx rFr wri htsofta 2017-Apr-1109:29:38 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct tame Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) _ Opening (in) Mad Trunk 1 fb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft¢ 2017-Apr-1109:29:38 �� 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ..uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N