BLOWER DOOR TEST FORM
House infiltration Test Certification
Prescriptive and Performance Method
RFCF1v�"D
APR 16 ?019
Pe F itti c e C
4� ; loerj. '
( g Permit #: 13 D 1 - 0 6 K -7
I: 1_ v Ivew construction — Complete (. ) Existing —After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM (') _ ) 0 1 o Test Date: "f rfT�j
volum = I S 6 Q
ACH (5 ) = CFM (50) x 60 / Volume = 2-- Mechanical Ventilation required less than 3 ACH
Passi4 results must be & ACH (50) or less jPass ( ) Fail
FBC, EnI''trgy
The bull ying or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in !mate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower oor at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 53.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approve third party. A written report of the results of the test shall be signed by the party conducting the test and
provided'�to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal nvelope.
FBC, R sWantial
Where t 'fie air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure f 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwell Ong unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testina Company
Company�'Name: Pro -Duct Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
'.I
I hereby ertify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirem 'lnts in accordance with Section R402.4.1.2 Climate Zone 2.