HomeMy WebLinkAboutBUILDING PLANS PAGE 16-23TOP PLATE
Il:O.C. MAX.
6EGURE 2X4 W/ 2-1/4+
TAPCONS OR DRIVE PIN
(MIN. SHANK SIZE .145 MIN.
HEAD SIZE 300 MIN.
EMBEDMENT 1 Ya' �pl @
EA. END NOT t0 E
#NOTE: NAIL 514=AT4NCx TO ALL. 2X AS FER EXT. 5�41=-ATI4INCx NAILINCz, 86 4" O.G. MAX a EDrZES 4 6"-8" O.G. MAX IN THE 1=1ELD
ST.
ID ING
SECURE THEATHING Jq ��
WITH MIN. 2d PER BLK
Ea. END EXTERIOR ARCHWAY
WITH WINDOW
1- 9GAl F. 1/211w1'-PJ'
VALLEY FLASHING DETAIL
132' O.G.
4 BOTTC
1/2, C . BC
1/2' CLG. ARD
1/2, D
OOD
7/2X4
•16'
.0x
ONT.
2X4 WOOD -
SS
STUDS s16,
BLOCKING
OC UAN
MID -WALL
SECURE BT.
PLATE TO
1/2' DRYWALL
1/2'k9'
32, OG.
W/ 10d IMAk
EMBE
NAIL s 32 O
X
6E
i CONC. SLAB
DET I
0
N ATION
r ILS SP 32' .G. MAk
1ST FLOOR 1ST FLOOR
INT. BEARING WAL INT. BEARIP
(NO UPLIFT) (W/ UPLIFT
SECURE t0
WOOD W/2-12d s 6 "
O.G. STAGGERE
SECURE 2X4 W/ 2-3{r
TAPCONS OR DRIVE PIN
(MIN. SHANK SITE .145 MIN.
HEAD SIZE 300 MIN.
EMBEDMENT I Y4 W/IN 8'
EA. END NOT TO EXCEED
Is, O.C. MAI
2X4 SOLID BL
SECURE TO SHEA
WITH MIN. 2-12d PER
EXTERIOR ARCHWAY
2X4 SECURED TO
GABLE ENG W/(2)I
6"-8" O.C. i
L-30 s
BLOCKII
—2x4 BLOCKING
• EA RAFTER
EA
P2ia EA. \
RAFTER
Vx4
RAFTE4'O.G.
FRAMING
(TYP)
FRAMED OVERHANG
V N.TS.
2X4 TOP PLAT GLG. I
1/2' GLG.
/
2X4 CONT.
1/2' DRYWALL
STRESS
BLOCKING
MID -WALL
SECURE ST.PLAT
TO SLAB W/ 10d
MASONRY NAIL s
32' O.G. MAX
2X4 PT.
PLATE
GONC.SLAB
PRE-FAB
TRUSS
GONT. TAL—'
TRACKS, OP t
BOTTOM
1/2' DRYWAL
2X4 WOOD CHANNEL S14A
STUDS o24" STUDS 24' ON
W
Off, LAYER OF 1/2'
TYPE GYPSUM
WALLFOA
ATTACHE EA
SIDE s 12
UPRIGHT
C. SLAB
jN70N-BRG.)
1ST FLOOR ALL
W L TYP. INT. WALL UDS
NON- BRG.
SCLE1I'-0'
TRLLSS TO WOOD FRAMING
SIMPSON MTS-12
PRE-ENG TRUSS
PRE-ENG.TRUSS
DO TOP LATE
2 T STRESS
DEL. 2X TOP PLATE i
SP4032' O. MAX /ID
WALL
i/Ib' O.SB. a
2 S S 16, O.G. MAX,
OR 1/16' ZIP SHEATHING aN
SYSTEM (INSTALLED PER
MANUF. SPECS.)
4 SUSFLOOR GLUED
2X BLOCKING s
CREWED AS PER
TOP OF
ER SCHEDULE
1/2' CDX ?
I FLOOR STUDS TO
FLOOR STUDS
2X STUDS 16' O.G. MAX. w
81MPSON META-36 s 32'
2X BTM. PLATE
O.C. MAX
3/4' FLOOR DECKING
MStA-36 32' O.G.
MAX
PRE-ENGINEERED
FLOOR GIRDER
PRE-ENG FLOOR TRUSS
DOUBLE TOP PLATE
PRE- ENGINEERED
FLOOR TRUSS
2x CONTINOUS STF4' 66
LOCKING MID WALL
UI
CONTINUOUS SHEATHING TO BEGIN AT TOP OF ELK
2 STUDS s 16' O.C. MAX,
W/ I/4' GAP FROM BLK. TO O.S.B.
U.O
I/2' WL. BD.
O
HORIZONTAL 2X S.PF. STRUCTURAL FLOCKING AT
SEGU Bt. PLATE TO
PERIMETER OF O.S.R. TO PROVIDE CONT. NAIL PATTERN
SP4s32' OC. AX
SLAB 'x9' ANCHOR
Q
REMAINING AREA TO BE SHEATHED FROM DEL. TOP
BOLT W/ WASHER SET N
PLATE TO HORIZONTAL BLOCKING.
SIMPSON H STRENGTH
�
EPDXY T' E ED. MIN.
4Y
SHEATHING s TOP OF WOOD FRAMED WALL TO BE
'
STAGGERED MIN. OF 16' FROM SHEET BELOW
•
.. w : SIMPSON S104
32' O.G. MAX
Q
INSTALL ALL SHEETS W/PACE GRAIN PARALLEL
TO STUDS
g INT. 2-STORY L.B.
EXT. WALL SHEATHING
SCALE:I/1'=I'-0'
4 SGALE:I/2'=1'-®'
SIZE PER
DOOR/\
WINDOW
OPENING
II /
o -Y o
SECURE 2x4 ON
FLAT TO BLK
W/ CUT NAILS.
SIDES:
2X6 GARAGE DOOR BUCK W/ (5)
17 ii'XS' A -BOLTS 4" EMBEDMENT MIN. 0
W/ 29X2'X16 WASHER AND NUT
SPACED EVENLY FROM FLOOR TO
GARAGE DOOR HDR IN JOINTS
PRIOR TO FILLING.
I-2X6 PT BLOCK s CENTER O°
DOOR HEADER W/(U1j'XS" J-BOLTS
0 4" EMBEDMENT W/ 2'X2'XYe' WASHER 0
AND NUT.
� �NorEs:
ALL ANCHORS SHALL BE IN ACCORDANCE TO
MANUFACTURER'S INSTALLATION INSTRUCTIONS WHERE
SUCH INSTRUCTIONS ARE MORE STRINGENT
GARAGE DOOR
3 BUCK ATTACHMENT
SCALE: 1/2' -1' -0'
" CDX PLYWOOD
6'-o" OPENIN(
G d
e
d °
PRECAST LINTEL Q
Q
INiA I I J
• —
.. ".
T\OX
OCK W/ (2)
"x3" C7R DRIVE PINdN ANK 14i3)
MdIN 8' OF EACND1 0'. MAX SPA {
1a6°
d
d. 4
° de a
., ° 4
a a
a
cat A � d O
a� 9 a
4.
47
ARCH WINDOW FRAj7E7
TYP. EXTERIOR WINDOW
4 DOOR OPENING WD FRA
SCALE:
5CAL.E: 3/4" = I'-0"
PRE-ENG TRUSSES W/ TRUSS
CONNECTOR VERIFY W/
FRAMING PLAN
DOUBLE TOP PLATE
r
JACK
G
2x SIWS s 16' O.C. MAX W/
SH THING. SHEATHING TO BE
PIN J' OF WINDOW/ DOOR
ENING AND SECURE PER
NAILING SCHEDULE
KING STUDS (SEE HEADER
SPAN CHART FOR DETAILS
AND SPECIFICATION)
JACKS (SEE HEADER SPAN
CHART FOR DETAILS AND
SPECIFICATION)
JACK STUD ASSEMBLY TO BE
SECURED ONE PLY s A TIME.
SE 12d NAILS, TWO WITHIN 6"
EACH END t NO MORE 19
TN 12' O.G. STAGGERED
SP4 H5 s TOP AND
BOTT LATES s EA. FULL
LENGTH S BOTH SIDES
OF OPENI
SHEATHING T AP To
BOTTOM O= V
TRUSS BELOW_ THING
MUST NOT BREAK I'- ° MIN.
FROM 2ND FLR LINE.
-ENG TRUSSES OR
FRAMED RAFTERS
2x RIDGE ONE slz�NAIL8311=
THAN R
MIN. (W 12d
MIN. (4) 10d GUN NAILS
2x4 COLLAR TIE AT EVERY OTHER
RAFTER W/
MIN. (3) 12d NAILS OR
MIK (4) 10d GUN NAILS
Ix8 NAILER SECURE TO TRU68ES
BELOW W/
(2) 12d NAILS OR
(3) 10d GUN NAILS s EA. TRUSS
RAFTER TO TRLLSS MTS-12
CREATE VOID FOR STRAP
PENETRATION
ROOF DECKING OVER
PRE-ENG TRUSSES
HEADER SIZE PER
SPAN CHART.
o�
TYP. INTERIOR
i1
DOOR OPENING WD
Or —ALE: 1/2' =1' -O'
00 REBAR VERT_ IN
SOLID GROUTED CELL
5/8' THICK, 3 COAT
CEMENT PLASTER
APPLIED
DIRECTLY TO
MASONRY
OCONV. FRAMED ROOF
SCALE: 1/2'=I'-C'
PRE-ENG TRUSSES W/ TRUSS
CONNECTOR VERIFY W/
FRAMING PLAN
DOUBLE TOP PLATE
CRIPPLE STUDS s 16' O.C.
MAX
SIMPSON LSTA-12 A JACK
BOTH SI OF
PE NG.
2 s 16' O.G. MAX W/
PING. SHEATHING TO BE
IN }' O= WINDOW/ DOOR
OPENING AND SECURE PER
NAILING SCHEDULE
KING STUDS (SEE HEADER
SPAN CHART FOR DETAILS
AND SPECIFICATION)
JACKS (SEE HEADER SPAN
CHART FOR DETAILS AND _
SPECIFICATION)
CK STUD ASSEMBLY TO BE
S RED ONE PLY s A TIME_
USE NAILS, TWO WITHIN 6'
FROM E END t NO MORE
THAN =O. TAAG=RED
1/2'x9' A.B. MIN. i'
EMBEDMENMT 8" F GH
END E 32' O.C. MAX.
SP4 OR H5 s TOP AND
" I115 UPLIFT
SIMPSOM HTSM20
W/10 10d TO TRUSS
AND (4) 1/4' x 2 1/4'
TAPCONS TO GONT
POURED LINTEL
• I900 UPLIFT
(2) SIMPSoM HTSM20
INSTALLED ON OPPOSITE
FACES OF BLOCK WALL
W/10 10d TO TRUSS
AND (4) 1/4' x 2 1/4'
TAPCONS TO GONT
-POURED LINTEL
PRE-ENG TRUSS
CONTINUOUS
BOND BEAM
BOTTOM PLATES s EA FULL TRUSS ANCHOR
LENGTH STUD, BOTH SIDES
or OpEN1 RETROFIT
N.TS.
LINE OF SLAB
CORNER BEAD
SEALANT E
BACKER ROD
8' CMU SEE
STRUCTURAL FOR
REINFORCEMENT
-2x6 P.T_ WD
ATTACHED TO FILL
CELL AS PER
PI�DUGT
SPPROVAL WO.
FROM MIAMI-DADS
COUNTY
WEATHER STRIP
MOULDINGS ALL
AROUND (SY
DOOR MANUF )
CaALV. STEEL
'
TRACK BRACKETS
FA6TENED TO
WOOD JAMB W/
3/16'xl 1/4' LAG
GALv. STEEL
OVERHEAD DOOR
SCREWS
VERiIGAL TRACK
1' MIN,
BY OTHERS
BY MAI,F.
SLIDE
FASTENED TO
ROOM
W1 1 4 -2BR /2'
GARAGE DOOR JAMBS
CARRIACA=- SOLtS
13 SCALE: I/2'=l'-0"
AND LOCK NUTS.
PRE -EN,3)
MTS-12
1/16" 055.
GDX PLYWOOD. T D
\\
PER FASTENER CHE
NIT 2
MTS-12
OR1/16'ZI SHE
SYSTEM l R
MANUF. S
2x4 DER
STU $CURE
BETWEEN BAYS W/
PRi=-El
(3) 12d' ACH END
2x DOUB TOP PLATE
06 s 16' O.G.
MT -12 s EVER STUD
2X4 BT. PLATE
DORMER
16ZATTACHMENT
15 SCALE-. 1/2"0'-0'
W
2x4 DBL.
TOP PLATE
IX4 STUDS 16'
116" OS.B.
TEXT. FINISH
META-16
�CMU WALL
CONTROL DATE: 07/01/15
1441 N. RONALD REAGAN BLVD.
LONGWOOD, FL 32750
PH: 407-774-6078
FAX: 407-774-4078
www.abdesigngroup.com
AA #: 0003325 J
F
W
w
U
N
0
0.
q
F
A
ti
evsarv. as LOT:
CREEKSIDE
LOT 51
PROJECT*
04321.000 051R1
MOaEri
4EAB
"1672- ARIA"
G'APAG'E 8WDfG.-
LEFT
PAGE:
MISC.
DETAILS
t60 MPH EXP. C
ARCHITECT:
STATE OF FLORIDA
DATE: DATE: 06/06/18
SCA'L.E: 1/4"=1'-0"
SriEET
1L)4
0UY1U1115 rm 1111L n
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Owners Name
Applicant
Product
Opening Design
Product Rated
Manufacturer
Model #
Product Approval
Glass Type
Method of Attachment
Pressure
Design Pressure
Number
1/4" concrete screw 6" edge distance @ head, 4" edge
Swing door
(+36) / (47)
(+67) / {-67}
Therma-Tru
Smooth Star
FL20461.17
N/A
distance @ jamb, 4" each side of transom centerline to
bucking. Fastener spacing @ 15" o/c max. @ head and
jamb. Min, embedment of all anchors to be 1 1/4"
Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from
corners, 11 3/4" o/c at jamb, 16" @ head. 1 1/4"
embedment. Type II: 3/16" or 1/4" ITW concrete tapcon
SH Window
(+38) / (48)
(+50) / (-50)
Ply Gem
Ply Gem 1500
FL16103.1-R9
Non Impact
anchor. 6" max• from corners, 7 1/4" o/c at jamb, 10 1/4"@
head. 1 1/4" embedment. Two additional tapcons
midspan and one at lower frame required vertically each
side. Install per manufacturers recommended
requirements.
Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from
corners, 14" o/c at jamb, 10" @ head. 1 1/4" embedment.
Type II: 3/16" or 1/4" ITW concrete tapcon anchor. 6" max.
SH Window (Integral
(+38) / (-48)
(+50) / (-55)
Ply Gem
Ply Gem 1500
FL16100.1-R6
Non Impact
from corners, 8 1/2" o/c atjamb, 6" @ head. 1 1/4"
Mulled)
embedment. Eight additional tapcons top and bottom
required horitontally, one midspan vertically each side.
Install per manufacturers recommended requirements.
1/4" concrete tapcon anchor. 2 1/2" minimum edge
Sliding Glass Door
(+33) / (41)
(+50) / (-50)
Ply Gem
Builders Series
FL14634.2-R3
Non Impact
distance. 6" max o/c from corners and 20 3/4" max o/c
4780
elsewhere top, vertically and bottom. 2 1/2" min
embedment.
1/4" concrete tapcon anchor. 6" max o/c for comers.
Tapcon required 3" each side of center of opening top and
Opaque single door
(+36) / (47)
(+47) / (47)
Therma-Tru
Smooth Star
FL14985.1-R2
N/A
bottom. Top and bottom centerline of each door slab get
with transom
tapcon. Rest of vertical o/c spacing is 14" max. 1 1/4"
embedment.
x 2-3/4" Hilti sleeve anchors 6" from ends 22" O/C
Double Garage Door8"
( ) +29 / (- 35 )
(+46) (-42)
/
ClClopay
16.2x7 73 W6
FL16546.6-R9
N/A
Use galvanized (zinc coated) roofing nails, 11 or 12 gauge,
with at least 3/8" dia. heads, long enough to penetrate
through plywood or 3/4" into boards. Use 4 nails per
Roof
IKO Cambridge
FL7006.1-R10
shingle placed 6-1/8" above the butt edge, approx. 1" and
13" from each end and 1/2" above each cutout. Drive nails
straight so that nail head is flush with, but not cutting into
shingle surface.
Miami -Dade approved corrosion resistant tin -caps and 12
Underlayment
Interwrap
RhinoRoof U20
FL15216.1-R3
gauge 1'/<" annular ring -shank nails,
spaced 6" o.c. at all laps and three staggered rows
fastened 12" o.c. in the field of the roll
Soffit
+31.6, -38.8
(+157) / (-46.1)
PlyGem
Variform Soffits
FL24161.1
1/4" x 20 stainless steel or ELCO Panelmate with minimum
Hurricane Panels
Hurricane Storm
embedment @ 1 3/4" in concrete / masonry, 2 1/2" min.
Less than 6' span
(+47) / (-53)
panel MFG.
24 GAGE
FL16293 R2
g spacing. edge distance 12" o/c max. s acin Can be headed screw
orall thread butwith wing nuts.
1/4" x 20 stainless steel or ELCO Panelmate with minimum
Hurricane Panels 6'
Hurricane Storm
embedment @ 1 3/4" in concrete / masonry, 2 1/2" min.
span or more
(+45) / (-50)
panel MFG.
24 GAGE
FL16293-R2
edge distance, 12" o/c max. spacing. Can be headed screw
orall thread butwith wing nuts.
Zip System
Install per manufacturers recommended requirements.
Sheathing
Huber
Wall Sheathing
17147-112
i1 N. RONALD REAGAN BLVD.
LONGWOOD, FL 32750
PH: 407-774-6078
FAX: 407-774-4078
www.abdesigngroup.com
AA #: 0003325 I
F
W
w
W
0
h
0.
v
w
A
F
A
F;
stiHaiV. de LOT:
CREEKSIDE
LOT 51
PROJECT�J:
04321.000 051R1
MODEL:
4EAB
"1672-ARIA"
GARAGE I®VMG:
LEFT
PAGE:
PRODUCT
APPRO T VALSX
160 MPH EXP. C
ARCHITECT -
STATE OF FLORIDA
PiLINr
DATE: 06/06/18
BCALE: 1/4"=1' - 0"
diva T
D 5
NOTE: NO.I.E• NOTE:
IF ZIP 814EATI-4ING SYSTEM 15 APPROVED BUIL >ING WRAP IF ZIP 51-4EATI-4INCs SYSTEM IS 6
INSTALLED, PLEASE SEE SHALL BE LAPPED A MINIMUM OP INSTALLED, PLEASE SEE 4'x4" SELF -ADHERING MEMBRANE
6" ® VERTICAL LAPS (ROLL FLASHING; (COMPATIBLE W/ HOUSE
MANUFACTURERS ENDS) 4 Co' ® HORIZONTAL LAPS. MANUFACTURERS WRAP MATERIAL) OVER
INSTALLATION PROCEDURES ALL SEAMS NEED TO BE TAPED LATH VERTICAL LAP TO BE I' INSTALLATION PROCEDURES APPROVED HOUSE WRAP.
WITH PORTIBER SHEATHING TAPE FLASHING TO EXTEND ONTO PIPE \�
/ I" OR LESS PIPE 7 �'x_ , 6'x6' SELF -ADHERING; MEMBRANE
PREFORMED CONTROL JOINT �" THICK, 3 GDAt CEMENT PENETRATION FLASHING (COMPATIBLE I HOUSE
WRAP MATERIAL) OVER 4'x4'
*, I FLASHING OVER APPROVED
FLANGE OP CONTROL JOINTS t \ PLASTER SELF -ADHERING MEMBRANE
BE WIRED TIED ). LATH D 9' WRB LAYER P PORTIPIBER HOUSE WRAP.
O.G. MAX (N CON NOTE: PO BUILDINGS PAPER N. LAP ®METAL LATH / / \ FLASHING TO EXTEND ONTO PIPE
NOTWALL
FASTEN CONTROL JOINT TO / \
WALL EVEN IF SCUD EXISTS L• � � �I
BEYOND EXCEPT STAPLES W/ APPROVED METAL LATH lx X X X 1
W LEG MAY BE USED TO TEMP. FASTENED 41' (VERT.) O.G. MAX '"
SECURE CONTROL JOINT At SUPPORTS X— FX —
DURING INSTALLATION WRB LAYER M �— GUT AdJp OVERLAP ONE SIDE OF /
FASTENER8 TO BE SPACED STUCCO WRAP METAL LATH �LASPING ING MEMBRANE CUT AND OVERLAP ONE
• T' O.C. MAX VERTICALLY SELF -ADHERING; MEMBRANEE
WOOD SHEATHING I STEP MEP PLASHING
OR 1/16' YIP SHEATHING / WRB LAYER M, �' THICK, 3 COAT CEMENT I LAYER M,
I SYSTEM q NSTALLED PER STUCCO WRAP I PLASTER STUCCO WRAP
MANJF. S. Co.) METAL LATH
6" MIN PAPER LAP BELOW ONLY /
111RB LAYER I"1, PORTIFIBER I WRB LAYER 02, FORTIFIBER \ WBUILDII RB LAYER 2, FORTIFIBER
BUILDING PAPER BUILDING; PAPER METAL LATH
PAPER
\ / STUCCO WRAP
6'x6' SELF -ADHERING MEMBRANE
i . � FLASHING OVER 4'x4'
SELF -ADHERING MEMBRANE
INSTALL FASTENED (CLIPS, rLASHI OVER APPROVED
AP MIN. WOOD SHEATHING STRAPS, STAPLES) AS
LATH SHALL NOT OR IA6' ZIP SHEATHING FLASHING TO EMEND ONTO PIPE
6° To a° 6 ro e° % J' REQUIRED TO SECURE
T CONTINUOUSROUCsH CONTROL MIN. MIN. PS'IYSTFMSPEGSALLED PER 4'x4' SELF -ADHERING MEMBRANE
PIPE/ WIRE TO FRAMING
JOINTS BUT 54ALL " '+ ',: "* . 'o- " , mx s r ^>v FLASHING OVER APPROVED
BE STOPPED AND HOUSE WRAP.
LIED AT EACH SIDE. PROVIDE 2X4 BLOCKING I' MIN LATH FLASHING TO ExTK
PER A5TM C1063 PLACED FLAT MAX. 6' TO 6' LAALI- LAP R ND ONTO PIPE
7•10.1'4 / PROM CONTROL JOINT WHEN APER LAP \�
NOTE: ~ \ STRUCCONTTURAL (STUD NT LS ON 2 SCALE: 1 1/2'=1'-0' INSTALLAPPROVEDSEALANT
AIR
1. PASTENED FOR LATH TO BE NAILS OR INFILTRATION BARRIER OVER
STAPLES IN COMPLIANCE W/ ASTM C1063
2. WIRE LIES TO BE (NO. IS) 024-15' WIRE / SHEATHING
3. BLOCKING SHOWN MAY BE IN ADDIT1 \ ELASTOMERIC COATING; OVER STUCCO/
70 WALL STUDS REQUIRED PER PLAN / C.V. FINISH (SEE TYP WALL SECTION)
Aukt( VERTICAL LATH
& PAPER DETAIL
WOOD STUDS -SECTION PER SECTION R703.7
�+ Exterior lathing and plastering
NOTE. SHEATHING Exterior use of Portland cement plaster
SIDE LAPS OF METAL OR 7/16' ZIP SHEATHING SYSTEM : shall comply with the application
PLASTER BASES SHALL (INSTALLED PER MANUF. SPECS.) I requirements of ASTM C 926-12A.
BE SECURED TO BUILDING NOTE:
6° MIN. Installation of exterior lathing and framing
„ „ FRAMING MEMBERS. PAPER ,I LAP IF ZIP SHEATHING SYSTEM IS shall comply with ASTM C 1063-12A.
O M TYPE CONTROL JOINT THEY SHALL BE LIED INSTALLED, PLEASE SEE
BETWEEN SUPPORTS MANUFACTURERS
WITH 0.0415-IN. (I.21-MM) STUCCO 4" LAP a LATH
WIRE AT INTERVALS NOT <i 3" LAP PAPER INSTALLATION PROCEDURESMORE THAN S' (22S-MM).
AS PER A5TM C1063
O1 I FOLv INWARD • Pr. a I FOLD INWARD • Pr. A 7.8.1. f F F= N i R A T I O>� IDT f L I F R Y 1�
O 7. CREASE + Pi. B
�-� v
/� -{��T lCKOT NOTE
(FOLD ® "I- 1 FOR REPAIR OF TEARS HORIZONTAL LATH 1�.�.�.
DETAIL WRB LAYERS, 1 EARS
MAY BE PATCHED
& PAPER DETAIL
W/HOUSE WRAP TAPE
PER MANUF. SPEC. OR
FOLD PEEL 4 STICK
. a6• g,
® 1/16" ZIP 51-4EATI41NG
SYSTEM (INSTALLED PER
MANUF. SPECS.) OR
I. FOLD INWARD a LFOLD INWARD • PT.A 'WOOD 5HEATHING OR CMU
. A ® 2. CREASE • FT. 15WR5 LAYER "I,
a. CREASE • Pr. B
3. CREa6E . PT. C `. STUCCO WRAP (FRAME ONLY)
3. CREASE • PT. C
4. FOLD PT. C OVER PT.
B TILL PT. C TOUC44E6 {t
ISI FLANGE -y -1
® f 15"TRICK, 3 COAT CEMENT
PLASTER (FRAME), 1/2" 2 COAT
CEMENT PLASTER (CMU) LEGEND
METAL LATH (FRAME ONLY)
®' LAP WRR E TAPE OVER D R I N C-� fi L )�>�1 (I�JR5
�� WATERTIGHT R001=/WALL SCREED LA`r R #I STIXCCO WRA4 =)
. Tt• BOTTOM
FLANGE
NOTE: SEAL. POLP• 2
NQr CUT. IF ZIP 51-4EAT4NG SYSTEM IS
INSTALLED, PLEASE SEE P ASTIEE 3 GOAT cEMEO GAL "L" TYPE CONTINUOUS I.URB L)L�, r R *2 (1=ORT IF 15ER — — — — — —
PLASTER RiQAME), II s Coar � -, ` CxAL V. METAL FLAS1-41NCx
MANUFACTURERS Ce-q- "-ASTER (CMU) Z
INSTALLATION PROCEDURES u� LAYER n, FORTIFIBER (NAIL TO ROOF DECK, NOT �U I L D I MCC P>4i� R�
BUILDING PAPER(FRAI ONLY) WALL SPEATI-41NCs)
WRBLAYER M. CAP SHINGLE - DO NOT NAIL, �IETAL LATT 4 X X X X
STUCCO I(FRAME ONLY) INSTALL WITH ROOF CEMENT
w w LAP LAYERS OF BUILDING WRAP
6HM AWNONL.Y)T�
ASTUCCO 4
)!� BOVE ° a-
FRAhfE OR Gt'Al III �-^�
-tom SCROD �� �.f ROOF CEMENT W00 Ji� ATi�Il�l
Sx8 LLU1LL FLASHING ROOF PER ELEVATIONS �/
OR 111(o" ZIP 6I-4EATNING SYSTEM
1 n KICK-OUTPLA04M(SEE (INSTALLED PER MANIJ=. SPECS.)
DETAIL) ��.
NOTE: 5ELF-)4I��E511 E FLA5HING — — — —
�
IF ZIP 514EATI-41NCs SYSTEM 15 NOT
INSTALLED, PLEASE SEE
MANUFACTURERS t" IETAL LAT�4: LATT 4 TO 8E DER 5ECTION
FELT UNDERLAYMENT INSTALLATION PROCEDURES
\ � y --- WATER R, DO SEAL (BEND OR
/y INSTALL �^��T) i��Q�3..1 / )451"� G - 87 - 09, 1"I ll�l, 2.� LBS.
8HMCd.E 111 ING 0, FLEAS- NG AT BOTTI OEM OF ROOF 4 DRIP EDGE: OVR3, WALL INTERSECTIONS i p 5I � A RD ( fiT I L It O R N Q �
IA L
EXTEND In' BELOW
SI-IEATFNNG, I"ECHAKIOALLY FASC'.IA WRAP POES NOT 1"I E E T 5 PE G 1 I G A T I ON e)
FASTEN 4' OL. MAX " L" F L A S r1 I N G-
5 N.T.S.
•1 N. RONALD REAGAN BLVD.
LONGWOOD, FL 32750
PH: 407-774-6078
FAX: 407-774-4078
www.abdesigngroup.com
AA #: 0003325
W
1U
W
0
0.
U
A
F
A
atmnzv. & LOT:
CREEKSIDE
LOT 51
PROJMT#
04321.000 051R1
)dODEL:
4EAB
"1672-ARIA"
GAP.AGIC 8111NCi':
LEFT
PAGE:
WALL
ASSEMBLY
DETAILS
160 MPH EXP. C
ARCHITECT:
STATE OF FLORIDA
K
wr
DART' 06/06/18
ECAL= 1/4$$=1'-0"
81MET
WAS.
NOTE:
IF ZIP SH THINGS SYSTEM IS INSTALL 6" SELF-ADH
LEASE SEE MEMBRANE FLASHING
INSTALLED, TOP, SIDE(S) AND BO
S OF NON -MO
INSTALLATION RS OCEAURE:S FRAME FLANGEOF THE EXH/tL
X
VENT IS BE SET IN BED
X,
OF AL T T TOP AND
SI SEALANT IS TO BE
t L AS TO DEFLECT
AY FROM JOINTS.
i
'I
E- AD ALL AROUND
N APPLY SEALANT ALL
X
TS AND INTERSECTIONS
' I
PLY SEALANT AT PERIMETER OF
BACKER ROD y
ON -MOVABLE FRAME AND STUCCO
'
ON ALL SIDES, 4" CAULKING; s JOINT
ALL AROUND
PER SECTION R703.7
Exterior lathing and plastering
BACKER ROD
Exterior use of portland cement plaster
shall comply with the application
X,
requirements of ASTM C 926-12A.
1
In Ilation of exterior lathing and framing
'
x
shall omply with ASTM C 1063-12A.
WRP LAYER 01,
STUCCO WRAP
DRYER VENT
all CMU
HOODED VE T
4' THICK, 3 COA EI
PLASTER
METAL LATH
Ul LAYER 02, FORT
giJ(LDINGS PAPER
WOOD SHEATHINGS
(FRAME)
(IN5TALLED PER MANUF. 5 C5J OR
WOOD SHEATHINGS
WRB LAYER "I,
STUCCO WRAP
WRB LAYER , FORTIFIBER
BUI INGS P R
LATH
V YL CASINs BEAD
6' RAISED HAND
16' TO XI MID -WALL
WEEP SEIE a
6" WIDE STRIP SELF
ADHESIVE FLASHING;, CLEAN
MASONRY BEFORE APPLYINGs
Z FLASHING;
OVER 6CARATCH COAT
H IZONTAL WEEP SC ED
W./STONE VENEER
( FRAME TO BLOCK)
INMN'i
DRAINAGE PLANE (WRB
LAYER 11, STUCCO WRAP)
WRS LAYER *2 0=01RTII=IBER — — — — —
BUILDING PAPER)
METAL LATH x—x—x—x
5TUCGO
WOOD SHEATHING
OR 1/16" ,ZIP SHEATHING SYSTEM
(INSTALLED PER MANUF. SPECS.)
SEL1=-ADHE5IVE FLASHING — — — — —
NOTE:
MET,4L LATH: LATH TO 5E PER SECTION
R703.rt.1 / ASTM C-84-1-0e, 1" Illa. 2.5 LBS.
PER 5Q. YARD (UTILITY OR NOMINAL
LATH DOES NOT MEET 5PECIffICATION5)
ELEC. t-1
VERIFY LO
STUCCO
FINISH
6" SELF ADIlll
OVER TOP E SIDES
SELF
FLAW-41NCz
UNIT
PREMANUI=. DRYER
VENT GAP (SET IN
CONT. SEALANT)
SEALANT
TOP k SIDES
DRYER VENT
BUILDING; PAPER
OVER 'QUICK
FLASH"
PIPE THROUGH
WALL
I
6' SELF ADHESIVE —
FLASHING (INSTALL
PER MANUF. SPECS.)
BUILDING PAPER —
UNDER 'QUICK FLASH'
NOTE:
IF ZIP SHEATHING SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
A VENT PENETRATION
SCALE: N.T.S.
STUCCO SCRATCH COAT
4 1 COAT OF PAINT WleACK-
ROLL PRIOR TO
ELEC. METER IN5TALLATION
A HO
:C. METER FIELD
:IFY LOCATION
WOOD CON5TRUCTI
1/16' ZIP SHEATHINGS SY EM 7/16' ZIP SHEATHING SYSTEM
(INSTALLED PER M ics.) OR (INSTALLED PER MANUF. SPECS.) OR
WOOD SI-IEATI-II Cs WOOD SHEAT+�INGz
WR13 LAYER M,
06
WR5 I R STUCCO WRAP
STUCC:�W P WRB LAYER 02, FORTIFIBER
BUILDINGS PAPER
Wfplo ER 02, FORTIFIBER METAL LATH
Gx PAPER WOOD 1/6" TEXTURED
CONSTRUCTION i!�; �FINISH a WOOD
{ FASTEN TO WOOD STRUCTURAL
MEMBER o i" O.G. MAX
I'
" THICK, 3 COAT CEMENT e crlu y® TO JSID M-WALL
LASTER ;
,.- WEEP SCREED
�d
TO Ys" MIp-WALL —a
W P 62REED
6' WIDE STRIP SELF
ADHESIVE FLASHING;, CLEAN
AM
MASONRY BEFORE APPLYING%
I:o" 51=L DHE51VE 4
TEXTUREDFLA5�41NC� FINISH MASONRY
WOOD FRA D
WALLS HORIZONTAL WEEP SCREED
(FRAME TO BLOCK)
ZONTAL WEEP SCR D
RAMS TO FRAME
NOTE:
IF ZIP SHEATHING SYSTEM 15 INSTALLED,
PLEASE SEE MANUFACTURERS
INSTALLATION PROCEDURES
APPLY STUCCO SCRATCH COAT
AND ONE (1) LAYER OF PAINT
PRIOR TO INSTALLING ELEC.
METER
CAVITY TO BE FILLED
WITH RIGID POLYMERIC
ISOCYANOTE-POLY5LEND FOAM
-1 SIMILAR)
APPLY A SILICON
5A5E SEALANT AT POINT
THAT ELEC. WIRE PENETRATES
:;O SCRATCH
COAT LARGER THAN THE ELEC.
METER CAN OR METER CAN
COMBO OR METER CAN AND
DISCONNECT
O ELECTRICAL CONDUIT
PENETRATION
CUT OPENINGS IN
APPROVED HOUSEWRAP
FOR BOX INSTALLATION
WRB LAYER 41,
STUCCO WRAP
WOOD SHEATHING
APPROVED
HOUSEWRAP
BELOW
GUT SUCH THA
NO MEMBRANE
ENTERS BOX,
APPLY TO FAc
EDGE
APPLY E-Z BEAT
OVER 60 MIN
GRADE "D"
FELT-PROvIDE
SEALANT AT ALL
JOINTS AND
INTERSECTIONS
NOTE:
IF ZIP SHEATHINGS SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
WRB LAYER *I,
STUCCO WRAP
CUT "X" INTO
SELF -ADHERING
MEMBRANE FLASHING
APPLY SELF -ADHERING
MEMBRANE FLASHING
OVER BOX AND OvER
APPROVED WRB LAYER
•I
ST '*1
APPLY 60 MIN -
GRADE "D' FELT
OVER
SELF -ADHERING
FLASHING OVER
APROVED
HOUSEWRAP
�T 3
5T
0
WRB LAYER *I,
STUCCO WRAP
SELF -ADHERING
MEMBRANE FLASHING
WRB LAYER 02, FORTIFIBER
BUILDING PAPER
5T1 #4
ELASTOMERIC
COATING OVER
STUCCO/ G.V. FINISH
(SEE TYPICAL WALL
SECTION)
METAL LATH
STEP *E5 STEP #(o
OELECTRICAL RECEPTACLE
1 N. RONALD REAGAN BLVD.
LONGWOOD, FL 32750
PH: 407-774-6078
FAX: 407-774-4078
www.abdesigngroup.com
AA #: 0003325
r
W
0
F
8
A
F
q
64
stmnrv.
CREEKSIDE
LOT 51
PROJ]CCT#
04321.000 051R1
MODICU
4EAB
"1672- ARIA"
G A RAGIC 8'RMG:
LEFT
PAC&:
WALL
LASSEMBLY
DETAILS
160 MPH EXP. C
ARCHITECT:
STATE OF FLORIDA
06
PRINT
DATN. 06/06/18
SCAM 1/4"=1'-0"
BIi��T
WOOD SHEATHINGS
WOOD
CONSTRUCTION
3Y4" HAT CHANNE
W/s/e" TYPE IIX'
WOOD SHEATHING:
WR5 LAYER MI,
STUCCO WRAP
' THICK, 3 COAT CEMENT
PLASTER
WRB LAYER MI,
STUCCO WRAP
WRB LAYER M2, FORtIF ER
BUILDINGS PAPER
J' THICK, 3 COAT MENT
PLASTER
6' SAP. TOP WEEP SCREED
t0 S�NCs EHIND WEEP SCREED
All a tl♦ OAIAI
WR5 LAYER MI, `t
STUCCO WRAP `
AMIGO AM(p6-WFWC--I80
CUSTOM CASINGS BEAD
---`
(SHOWN FO CLARIFICATION OF
SEPARAT ACCESSORIES ONLY)
ASING BEAD
10A DTL. ® CANT.
SCALE: 1 1/2"=1'-0"
6' SELF-ADHEREINGS
FLASHING: WRAPPED
• TOP OF WEEP SCREED
TO SHEATHINGS BELOW
_ WR5 LAYER 01,
STUCCO WRAP
I
�— WR5 LAYER 02, FORTIFIB
BUILDINGS PAPER
i
i
r
6' SELF-ADHEREINGs
FLASHING: WRAPPED
a CORNER OF CANTILEVER
NOTE:
IF Z110 SHEATHIN SYSTEM IS
INSTALLED, PLEA SEE
MANI.4FACTURERS
INSTALLATION PROC URES
NOTE-,
1 IETAL LATH: LATH TO 5E PER 5Z
R103.7.1 / A5Tt'*l C-04 1-0S, 1„IIN. 2.
i=R 5Q. '1(,4RD (UTILIT'r OR NOl"I
L H POE5 NOT 1 IrE-' S r7CI I ,4TION5)
NOTE: OD CONSTRUCTION
IF ZIP SHEAT INGS SY IS
INSTALLED, EASE E
MANUFACTURERS WEATHER RESISTIVE
INSTALLATION PROCEDURE BARRIER MI
3/4 RESILI t —WEATHER RESISTIVE
HAT CHANNEL BARRIER M2
VINYL GAS EA
;,''� J' THICK, 3 COAT CEMENT
- PLASTER
R
5/8' TY WALL .l METAL LATH
W/TEXTU AINTED \ WOOD SHAtHINCs
FIN(;ino' YIP ATHWc, 8T81EM
COAT CEMENT
VINYL CORNER BEAD
VINYL CASINGS BEAD
11D DRIP EDGE
INSTALLATION
NOTE:
IF ZIP -SHEATHING SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
5/8" TYPE 'X" DRYWALL
W/TEXTUREP 4 PAINTED
FINISH
8" THICK, 3 COAT CEMENT
PLASTER
11
AV -
VINYL CA51NGz BEAD
EDG
(SHOWN FOR CLARIFICATIONOF
SEPARATE ACCESSORIES Y)
WOOD CONSTRUCITON
WEATHER RESISTIVE
DARRIER MI
WEATHER RESISTIVE
OARRIER 02
}' THICK, 3 COAT CEMENT
PLASTER
�MEETTApL LATH � {����
��NRs*? ' ��..4rtTN1F�fCs SYSTEM
INS7�14.FfANLR &IOSCSJ
VNYL CORP. 4'
T25ITIVE DRAIN
AEP SCREED
ae
NO GsAP ti FIELD
(SHOWN FOR CLARIFICATION OF
SEPARATE ACCESSORIES ONLY)
::�TALLXTION
EXT. NOD FRAMED
WALL
SUB-FLOO ECKING
PRE-ENGS'D SS
WEATHER RESIST(
BARRIER
WEATHER RESISTIVE
/ X—*7V�
BARRIER M2
P THICK, 3 GOAT CEMENT RIES
PLASTER
METAL LATH
WOOD SHEATHINGS
4" POSITIVE DRAIN WEEP SCREED
N P&IL*P
(SHOWN FORA9CAIM1.0ATION Or -
SEPARATE ACCEMaIRIES ONLY)
EXTERIOR GRADE
DRY WALL
THICK, 3 COAT CEME
PLASTER
VINYL CORNER BEAD
1�►�7�T'�`7i►Cc'
10 CANTILEVER DR
EDGE
LEGEN
DRAINAGE F'LANE (WR5
LA,I ER #1, STUCCO WRAP)
UJRS LAYER 1*2 (1=01RT11=(B5R — — — — —
BU f LD INCH PAP1=R�
1 IETAL LATH x x x x
5TUCC0
WOOD SHEAT4NC4
OR 1116" ZIP SHEATHING SYSTEM
(INSTALLED PER MANUF. SPECS.)
SELr--ADHESIVE 1=LASHING
0
FINISH LAYER (2 LAYER
EL 4
STI A DRIP
EGO
DECK
D
)�
1,�"Xl V4" P.T. SIMULATED
WOOD (TREX) LER,
CONTINUOUS
t
3' X 3' 26 GSA. GSA
METAL DRIP ED
SEt IN FULL B OF
SEALANT, V
SPACE F DRIP
FACE TO t X
4" FOR BACKER
ROID 4SEALANT
WATER PROOFINGI
I
WEATHER RESISTIVE
LAYER (2 LAYER L 4
BARRIER *1
StICK) WRAPPED r-
I
L
WEATHER RESISTIVE
BALCONY DECK TO
BARRIER 02
CANTILEVER
1
6 PEEL 4 STICK a
DECK MEM5RANE,
DRIP EDGE TO DECK
EXTEND OVER DRIP
SUB FLOOR
EDGSE
®�
3" X 3' 26 GSA. GSALV.
METAL DRIP EDGE
SEt IN FULL BED OF
I Y"XI I%` P.T. OR I At
SEALANT, )�" MIN.
WOOp (TREX) FI E
SPACE FROM DRIP
CONTINUOUS
FACE TO TRE?C
)14" GAP FO
`—�
INYL CASING BEAD
ROD 4 SEAL
W TER PROOFINCS let
FINISH LAYER AVER
LA R (2 LAYER PEEL 4
PEEL 4 STICK)
StIC WRAPPED FROM
3/4 RESILIEN
c
BALC Y DECK TO
HAT CHANNI
GANtIL R
VINYL CASIN A
THICK, COAT CEMENT
PLASTER
METAL LAta {
_
9/S" TYPE " DRYWALL
WOOD AT
WlCEXTURE 4 PAINTED
WEATHER RESIS vE
FINISH
BARRIER MI
WEATHER RESISTI
THIC 3 COAT CEMENT
DARRIER 02
PLAS R
4' POSITIVE DRAIN
vINY CORN BEAD
WEEP SCREED
V1.106L CASING: 5EAP NO GAP
IN FIELD
(SHOWN FOR CLARIFICATION
OF
SEPARATE ACCESSORIES ONLY)
BALCONY
DRIP
11A EDGE INSTALLATION
2x 1=RAMING MEMBER
$" THICK, 3 COAT CEfi
PLASTER �''
2 1 /2 " �-��
FA SHEAT( IINCs
AX,
.=X � _
�'
B LAYER 01,
STUCCO WRAP
OOD SHEATHING
MET LATH
WRB LAVE 1=ORTIP BER
Y4" GAP FOR BACKER
ROD 4 SEALANT —
VINYL CASINGS BEAD
WATER PROOFING Ist-
LAYER (2 LAYER PEE
4 STICK)
WOOD SHEATHINGS
WR5 LAYER Mi, —
STUCCO WRAP
WR5 LAYER '"2,N�ORTIFISER
BUILDING, PAPE —�
SHEATHINGS
R RESISTIVE
� MI
WEATHER RESISTIVE
BARRIER "1
WEATHER RESISTIVE
BARRIER 02
EXTERIOR COLUMN
-COLUMN SHEATHINGS
,6' S.A.F.
•1 K2'x3' 'L' FLASHING
'FULLY EMBEDDED IN
ROOF CEMENT
I X' X 3' 26 GSA. GSALV.
METAL DRIP EDGE
SET IN FULL BED OF
SEALANT,)4' MIN.
SPACE FROM DRIP
"FACE TO TREX
VINYL CASINGS BEAD
WATER PROOFING: let
LAYER (2 LAYER PEEL 4
STICK) WRAPPED FROM
BALCONY DECK to
�IANTILEVER
ICK, 3 COAT CEMENT
VINTL COLTER BEAc7 (SHOWN FOR CLARIF16,4,TION OF
VINYL CASINGS BEAD SEPARATE ACCr=S5ORrtS ONLY
BALCONY DRIP
11C EDGE INSTALLATION ® COLUMN
(wz" L" FLASHING)
SCALE: NTS
NOTE:
IF ZIP SHEATHINGS SYSTEM IS
INSTALLED, PLEASE SEE
i MANUFACTURERS
INSTALLATION PROCEDURES
i
WOOD 5HEATHING
METAL LATH A��Mrz
J" THICK, 3 COA
PLASTER
6 "SELF-ADI-4ERING
1=LASHING:
DRIP GAP
BUILDING PAP
WINDOW FLANGE
)C O RNER BEAD C FR E
2 1/2"
CORNER BEAD
(FASTENER 4 SPACING 0 -1" O.G.)
CMIU
V THICK, 3 COAT CEMENT
PLASTER APPLIED
DIRECTLY TO MASONRY
WR5 LAVER *I,
STUCCO WRA
WRB LAY *2, FORTIFIBER
BUILDIN PAPER
META ATI-4
$" T ICK, 3 COAT CEMENT
ASTER
WRB' LAYER MI,
STUCC� WRAP
it q
WR5 LAY 02, TIP1 5ER
BUILDI
METAL LA
J' TOCEET HICK CAT MN '
PLAST t ;
(o"S LF-ADHERINCs '
F SHING i
i
DRIP GAP
WINDOW FLANGE
15 B CA ING BEAD WINDOW
( FRAME, NO BAND)
1441 N. RONALD REAGAN BLVD.
LONGWOOD, FL 32750
PH: 407-774-6078
FAX: 407-774-4078
www.a bdesigngrou p.com
AA #: 0003325
h
W
U
W
0
F
0.'
A
ti
2
�vea=v a� zoT:
CREEKSIDE
LOT 51
PROJECT#
04321.000 051R1
MODELrt
4EAB
"1672- ARIA"
GARAGE O'11MG:
LEFT
PAGE:
WALL
ASSEMBLY
DETAILS
160 MPH EXP. C
ARCHITECT
STATE OF FLORIDA
0
DATE:
iAw.- 06/06/18
SCAM 1/4"=1'-0"
WOON SHEATHING
WRB LAYE 01,
STUCCO WR
WRB LAYER "2, F TIFIBE
BUILDING PAPER
METAL LATH
9" THICK, 3 COAT CEMENT
PLASTER
6 "SELF -ADHERING —
FLASHING
VINYL /
CASING BEAD
DRIP CAP
WINDOW FLANGE
vl
01,
NOTE:
IF ZIP SHEATHING SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
WOOD 5NEAT4
WRB LAVER
P
STUCCO W
WRB L ER 1*2, F-ORT11=15ER
5UIL G PAPER
�E AL LATI-4
✓s✓" TI-4ICK, 3 COAT CEMENT
PLASTER
'CURB LAYER "2, FORTIFE
BUILDING PAPER
METAL LATH
" THICK, 3 COAT CEMENT
PLASTER
6 "SELF - ADHIERING `\
FLASHING \\
DRIP CAP
WINDOW FLANGE
CASING BEAD C� WINDOW
1 Fr (FRAME, W/BAND)
5I-IEATI4ING
METAL LAT
WRB LATER *11,
STUCCO WRAP
WRB LAYER 02, FORTH=15E
BUILDING PAPER
" THICK, 3 GOAT CEMENT
PLASTER
VINYL ANGLED
CASING BEAD
VINYL CASING BEAD
NOTE:
IF ZIP SHEATHING SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
u�
(EXPLODED
vIEW POR
CLARITY)
W00D 5I4EAT
)',' GAP TYP
CASING BEAD
TO TRIM
IX TRIM MBER
a STUCCO
SIDING TRAN ION
SIDING
WRS LAYER "I,
STUCCO WRAP ^
" THICK, 3 COAT C NT
PLASTER
METAL LATH
L ER I'2, FORtIFIBE R i
I ING PAPER
OD SHEATHING
WR8 LAYER "I,
STUCCO WRAP
� 6" SEL DH4EREING
FLASHING PEEL B STICK
SIDING TO S TUC O
CASING BEAD
(CROSS SECTION)
WOOD CONSTRUCTION
BEYOND
WOOD SHEATHING —
WEATHER RESISTIVE
BARRIER m
THEIR RESISTIVE —
BA IER 02
§46x I ' LAP SIDING
l6' RE
SELF -AD ING —
FLASI ING
STARTER STRIP
DO NOT CAULK OR
—
SEAL OPENING.
GALV'D METAL
"Z' FLASHING
IWC�OD6tRIM � ER
SIDING TO STUCCO
0 BLOCK TO FRAME
TRANSITION
6' SELF -ADHERING
FLASHING
WEATHER RESISTIVE
BARRIER M
WEATHER RESISTIVE
BARRIER ►2
LASSHING DI 4ERING
GALVP METAL
"Z' FLASHING
DO NOT CAULK OR
SEAL OPENING
I } X 6" SIMULATED
W�OD TRIM MEMBER
.SEAL GAP W/CAULKING
OR APPROVED SEALANT
NOTE:
METAL LATH4: LATH TO BE PER SECTION
R-703.7.1 / ASTM C-547-09, MIN. 2.5 LBS.
PER SQ. YARD (UTILITY OR NOMINAL
LATI4 DOES NOT MEET SPECIFICATIONS)
SEALANT
WINDOW
I
2X FRAMING
` MEMBER
6' SELF- 4mNG
III WOOD S THING - I FLASHI
WR GO AP WEATHER sTIvE
SEALANT
WINDOW FRAME
FLANGE
2X FRAMING
MEMBER
BUILDING
WRAP
" THICK, 3 COAT CEMENT \
PLASTER
METAL LATH i
i
i
--------------------------------------- WRB LAY 02, PORTIFIBER
/ BUILDIN PAPER
i
j E-z BEAD VINYL CASING
(W/%' FLEXIBLE PVC B <ER ROD)
WRB LAYER *I, UCCO WRAP,
WRAPPED AR ND FRAMING
MEMBER
6L A HIESIVE FLASHIING
EATNINCx
T�I�_JZELOW EXPLODED
� 170R CLARITY
___----i--�
T1 P
C BEAD
LINpOW
dFld.SlddkL yL{�.Sp.:d.Af.P.H T�4.RP
BARRIER "1 1HER RESISTIVE
BRIER N IN LAP
III $ p bEATHER ER RESIST[ / / / 6' MIN. ABOVE TOP5ARRI
WRB LASER FOI\T If I f5fR web RE AL P SIDING Or z FLASHING(16
/#
/ I 4 WEATHE
RESIST[
R
BACKER ROD) \ / " SELF -ADHERING
6' SELP-ADHERING I ± i I ING
PLASHING \
Ys' THICK, 3 COAT \, I ' SEAL AP W/CAULKING
CEMENT PLASTER \ OR A VIED SEALANT
WEATHER RESISTIVE WEATHER SISTIVE
C A I N B E A D C R A I s E JD BARRIER "I BARRIER "I
WEATHER RESIST A vIN CASING
BARRIER 02 (WIV FLEXIBLE NC
5ACKEBA D (FRAME) SIDING TO STUCCO WEATHER RIE615TIVIE
17 C� FRAME TO FRAME BARRIER #z
SCALE: 1 /2"=1'-�" TRANSITION
--
° THICK, 3 COAT CEMENT
PLASTER
METAL LATH
WRB LAYER 1*2, FORTIFIBER
vING PAPER
SHEATHING
WRB LAYER *I,
STUCCO WRAP
6" WIDE PEEL E STI
OVER FLANGE
E-Z BEAD VINYL CASING
(W/W FLEXIBLE PVC BAC ROD)
APPLY FULL BED OF SEALANT BETWEE
FLANGE d BUILDING WRAP
]LEGEND
DRAINAGE PLANE (WRB
LAYER #I, STUCCO WRAP)
WRB LAYER *2 (FORTIF15ER — — — —
BUILDING PAPER)
METAL LATH x—x—x—x
STUCCO
WOOD SI-4EATI-41NG
OR 7/16' ZIP SHEATHING SYSTEM
(INSTALLED PER MANUP. SPECS.)
SELF-ADHESIVE FLASHING — — — —
1441 N. RONALD REAGAN BLVD.
LONGWOOD, FL 32750
PH: 407-7746078
FAX: 407-774-4078
www.abdesigngroup.com
kka
AA #: 0003325
F
w
U
w
0
a
v
w
A
F
A
BUBDM as LOT:
CREEKSIDE
LOT 51
PROJECT#
04321.000 051R1
WODEL:
4EAB
"16`72-ARIA"
GARAGE S� WMG:
LEFT
PAGE:
WALL
ASSEMBLY
DETAILS
160 MPH EXP. C
ARCHITECT -
STATE OF FLORIDA
l�f 0 6 2l As
DAT ., 06/06/18
BCALM 1/4"=1'-0"
BEZEET
CUT HOUSEWR+
AT 4W ANGLE
MOpIFIEp "I' CUT
IN HOUSEWRAP
LNE OF l
OPENING
APPROVED HOUSEWRAP
OVER SHEATHNG OVER
WD STUD WALL
STEP I
INSTALL 6'
SELF -ADHERING
FLASHING OVER
NAILING FLANGE AT
JAMS$
EXTEND FLASHING MIN
I' BELCW SILL
FLEXIBLE FLASHNG
DO NOT SEAL BOTTOM
FIN
STEP
TEMPORARILY —
FOLD -UP 4 SECURE
HOUSEWRAP(OR
TUCK FLAP UNDER)
at HEAD
FOLD HOUSE
N AT JAMBS
SLOPE SILL R.O. TO EXTERIOR
STEP
INSTALL 6'
SELF-ADHERINGs
FLASHING OVER
vINYL HEAD
FLASHNG (WITH END
DAMS) NAILING
FLANGE
EMEND
* SELF -ADHERING
*S FLASHING 1' MIN
BEYOND JAMB
FLASHING
INSTALL VINYL DRIP
CAP
2
ALIGN FLASHING
W/ INT. EDGE OF
SILL RO.
MECHANICALLY
FASTEN FANNED
EDGES.(CAP
NAILS, STAPLES)
INSTALL DUPONT
FLEXWRAP AS TE
FLASHING AT THE
4
IPPLY 4b' NOM.—
:ONTNUOUS BEAD
SEALANT AT
AMBS AND HEAD a
IPPLY TO BACK OF
IINDOW NAILING
LANGE IN LINE W/
mw-PUNCHED
IDLES OR SLOTS.
INSTALL &' WIDE ADHESIVE -
BACKED FLEXIBLE FLASHING
MATERIAL OVER DRIP CAP
JOINT(PROTECTO-WRAP
5T-20XL or EC7UIV)
STEP 4
INSTALL WINDC
PLUMB, LEVEL
AND SQUARE I
MNAPAC TUREI
WRItreK
—APPLY
MEMBRANE
FLASHING
OVER JOINT
STEP 5
t IS THE CONTACTORS R.ESPONSIBILTY TO VERIFY
THE COMPATIBILITY OF ALL PRODUCTS INCLUDING
HCUSEWRAP, SEALANTS t SELF -ADHERING
FLASHING MATERIALS USED DURING CONSTRUCTION.
INSTALL ALL MATERIALS PER MANUFACTURERS
WRITTEN SPECIFICATIONS
ANING: SEALANTS MAY REACT ADVERSELY P NOT
NOTE:
CLEAN AND SEAL JAMB TO SILL JOINTS WITH
DOW 1199 FOLLOWINGS COMPLETION OF
EXTERIOR RETROFIT WORK
NOTE:
REPAIR SGF-IEME SHOW! SHALL BE
6 �J f ►�+ I'� J JL P STEP
+ ti7 T E P IMPLEMENTED AT ALL WINDOWS WITH
VIDENGE OF INTRUSION BELOW THE
�j
WI OW OPENINGS
WINDOW FLASHING
INSTALLATION DETAILS
(FULL WFZAP )
5GALE: NT5
C T :
IF Z (' 3�4ATE INS 5�ST 15 f N5TAL L ,
f=fROCED�fRE5
SEAL INTERIOR PE ETER OF WINDOW WITH
SEALANT
1 N. RONALD REAGAN BLVD.
LONGWOOD, FL 32750
PH: 407-774-6078
FAX: 407-774-4078
www.abdesigngroup.com
AA #: 0003325
F
W
W
v
W
i
h
0.
r7
A
F
A
ti
simo v. a LOT:
CREEKSIDE
LO T 51
PROJECT#
04321.000 051R1
MODEL:
4EAB
"1672- ARIA"
GARAGE B'11MC;:
LEFT
PAGE:
WALL
ASSEMBLY
DETAILS:
WINDOW FLASHING
160 MPH EXP. C
ARCHTECT-
STATE OF FLORIDA
DATE: 06/06/18
OSCALM 1/4"=1'-0"
3SHEET
2x(o 5U5-BAND
W/1 "x4" NOTCH a
END, WRAPPED
PEEL 0 5TICK
DRIP EDGE
7/8" TEXTURED
FINISH a WOOD
1/2" TEXTURED
FINISH a CMU
IN
METAL FASCIA
WRAP YS" FROM
STUCCO, I" FROM
WOOD WALL
EXTERIOR WALL
(FRAME OR CMU) i
NOTE. NOTCH FOR 2Xro
SUB BAND ONLY
( )ELEVA710��_
METAL FA
2X6 SUB I:
ROOF KICK OUT REMOVED
FOR CLARITY
ROOF DECK (BEYOND)
\� DRIP EDGE, I" OFF WALL
(NOT INTO STUCCO)
- 1-1/0" TEXTURED FINISH a
WOOD, 1/2" TEXTURED
�i FINISH a CMu
2x& SU5-5,4ND W/I"x4" NOTCI4 a
\ END, WRAPPED IN PEEL 4 STICK
METAL FASCIA WRAP 1" OFF
WOOD WALL- 5U5 BAND 2"
OFF WOOD WALL
/81 tEXtUREC)
FINISH 0 LIJOOD,
1/2" TEXTURED
FINISH A CMU
METAL LATH
LUOOID SHEATHINCz
OR CMU
LURES LAYER "I,
STUCCO LURAF` (FRAME ONLY)
LUR5 LAYER 02, FORTIEI5ER
5UILDINCz PAPER
(FRAME ONLY)
ROOFING CEMENT
DRIP EDCaE
METAL KICK OUT
NOTE: IF ZIP SHEATHING 5Y5TE1" 1 15 IN5TALLED,
PLEASE SEE 1" IANUFACTURERS INSTALLATION
PROCEDURES
TRUSS TO 5E CUT a
TO AVOID CONTACT
D FINISH
To TRU55
% 611-all
ND W/I2"x4"
ND
C 14 WRAP
WALL
cMu)
SUB BAND DETAIL C) WALL
SUI3 BAND DETAIL @ WALL
W/KICK— (JUT
FRAME OR CMU
FELT PAPER
DRIP EDGE
(REFERENCE POINT
ONLY, FOR WALL OFF
SET OF COMPONENTS)
METAL FLASHING, WRAPPED
MIN. /V4" ABOVE BOTTOM OF
DRIP EDGE
2x SUB -BAND
W/I211x4° NOTCH is
END, WRAPPED IN
PEEL 4 STICK
*ROOF CEMENT a
ROOF EDGE
OMITTED FOR
CLARITY
FRAME OR CMU
WALL KICK -OUT FLASHING
FELT PAPER
DRIP EDGE
(REFERENCE POINT
ONLY. FOR WALL OFF
5ET OF COMPONENTS)
METAL FLASHING, WRAPPED
MIN. Y4" A50VE BOTTOM OF
DRIP EDGE
2x SUB -BAND
W/U�"x4" NOTCH a
END, WRAPPED IN
PEEL E STICK
*ROOF CEMENT a
ROOF EDGE
OMITTED FOR
CLARITY
1 N. RONALD REAGAN BLVD.
LONGWOOD, FL 32750
PH: 407-774-6078
FAX: 407-774-4078
www.abdesigngroup.com
AA #: 0003325
ti
w
U
W
0
F
U
W
A
F
A
Btmnm de LOT:
CREEKSIDE
LO T 51
PROJECT#
04321.000 051R1
adODEL:
4EAB
"1672- ARIA"
GARAGE 93WMG:
LEFT
PAGE:
WALL
ASSEMBLY
DETAILS:
SUB —BAND
160 MPH EXP. C
ARCHITECT -
STATE OF FLORID/A'
ROLAI� A ACRA
AR NO 93723
DATE: 06/06/18
BCALE: 1/4"=V-0"