HomeMy WebLinkAboutNOASCANNED 9Y 3t. Lucie County ARTMENT OF REGLTLATORY AND ECONOMIC RESOURCES (RER) ,RD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA !11Polyglass USA Inc. 11�11 W. Newport Center Drive Deerfield Beach, FL 33442 MIAMI-DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.Qov/economv Th's NOA is being issued under the applicable rules and regulations governing the use of construction materials. The do umentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be use ld in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). Ths NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section pr�l Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this duct ormaterial tested for quality assurance purposes. If this product or material fails to perform in the accepted m�tmer, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or su pen d the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the reuirements of the applicable building code. T 'is product is approved as described herein, and has been designed to comply with the Florida Building Code in lulling the High Velocity Hurricane Zone of the Florida Building Code. : Polyglass Polystick Underlayments FILE COPY TG: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following "Miami -Dade County Product Control Approved", unless otherwise noted herein. K)ENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in'�ihe applicable building code negatively affecting the performance of this product. RAT[NATION of this NOA will occur after the expiration date or if there has been a revision or change in the serials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section his NOA shall be cause for termination and removal of NOA_ VERTISEWNT: The NOA number preceded by the words Miami -Dade County, Florida, and followed b I the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it hall be done in its entirety. 'ECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and be available for inspection at the job site at the request of the Building Official_ NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 9. submitted documentation was reviewed by Freddy Sernino.. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 �l COMPONENT APPROVAL Roofing -v• Underlayment SBS , APP Self -Adhering Modified Bitumen )UCTS DESCRIPTION: Test Product Product Dimensions Specification Description ick IR-Xe 65' x 313 3/s" ASTM D 1970 A fine granular/sand top surface self -adhering, APP ' Ctw ng Or 65' x 3' polymer modified, fiberglass reinforced, bituminous )n #1 & #2 60 mils thick sheet material for use as an underlayment in sloped roof assemblies_ Designed as an ice & rain shield. fck Dual Pro 61' x 3'3-3/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester zcturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a )n #2 metal roofing and roof tile underlayment. ck Tile Pro 61' x 3'3-3/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester icturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal ,n #2 roofing and roof tile underlayment. ck TU Max 65'8" x 33-3/8" TAS 103 and A rubberized asphalt self -adhering, polyester reinforced tcturing 60 mils thick ASTM D 1970 waterproofing membrane_ Designed as a a roof tile ,n #1 & #2 underlayment. ck TU P 32' 10" x 3'3-3/s" TAS 103 and A rubberized asphalt waterproofing membrane, glass- rctwing 130 mils thick ASTM D 1970 fiber/polyester reinforced, with a granular surface ,n #2 designed for use as a tile roof underlayment. ck TU Plus 65' x 3'3 3/s" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester e Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal ,cturing roofing and roof tile underlayment. n#1 &#2 ck MTS 65'8" x 3'3 3/s" TAS 103 A homogeneous, rubberized asphalt waterproofing cturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film n #2 on the upper surface for use as an underlayment for metal roofing, roof the slate tiles and shingle underlayment. Plus 65'8" x 3'3 3/7 TAS 103 A homogen ous�ru ,,. en e • Iasp alt watemro a x S6 G 32'l0" x T 3- 8 T 1 - an Polyester remfo ced, 'B di ie i umen emmane 'wring ASTM D 6164 with a sanded back face and a granule top surface. For #2 use in roof tile underlayment systems. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 1. 2. I. 1. 2. JUFACTURING PLANTS: azelton, PA inter Haven, FL EVIDENCE SUBMITTED Test Agencv Test Identifier Test Name/Report Date y ( ERD P10870.09.08-R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798 & G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798 & G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798 & D1970 10/19/11 P40390.08.12-2 ASTM D 1623 08/07/12 P37590.07.13-1 ASTM D6164 07/02/13 P45270.05.14 TAS 103, TAS 110 & ASTM D1623 05/12/14 P46520.10.14 ASTM D1623 10/03/14 P44360.10.14 TAS 103 & TAS 110 10/07/14 P43290.10.14 ASTM D 1970 & TAS 110 10/17/14 PLYG-SC10130.06.16-3 TAS 103 & TAS 110 06/27/16 PLYG-10130.06.16-1 ASTM D1970 & TAS 110 06/27/16 sphalt Technologies PUSA-035-02-01 TAS 103 09/29/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-089-02-01 TAS 103/ASTM D4798 & G155 07/06/09 Technologies, Inc. JX20H7A TAS 103/ASTM D4798 & G155 04/01 /08 RX14E8A TAS 103/ASTM D4798 & G155 11/09/09 DX23D8B TAS 103/ASTM D4798 & G155 02/18/10 DX23D8A TAS 103/ASTM D4798 & G155 02/18/10 All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. PERMIT REQUIREMENTS: for building permit shall be accompanied by copies of the following: Notice of Acceptance. other documents required by the Building Official or applicable building code in order to properly evaluate the lation of this materials. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 3 of 8 'ALLATION PROCEDURES: Type 1: Wood, non -insulated Description: Min. 19/32" plywood or wood plank m Type E(I): Anchor sheet mechanically fastened to deck, membrane adhered or/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. ning: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap_ (for base sheet only) brane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered. cine: See General Limitations Below. Type 1: Wood, non -insulated Description: Min. 19/32" plywood or wood plank m Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered or/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. ning: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c_ at a minimum 4" head lap. (for base sheet only) brane: Elastoflex S6 G, hot asphalt applied cine: See General Limitations Below. k Type 1: Wood, non -insulated k Description: Min. 19/32" plywood or wood plank .em Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. hor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. tening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. nbrane: Polystick TU Plus, self -adhered_ racin6: See General Limitations Below. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 4. S. 6. 'ALLATION REQUIREMENTS: All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior -to application_ Place the underlayment over metal drip edge in accordance with RAS 111. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention j to lap areas. 7. j Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. S. ; All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. 2. LMTATIONS Fire classification is not part of this acceptance. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. J] Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick 1:R-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6, Polystick IR-Xe, Polystick ]Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (Days) MTS 1R-Xe Elastoflex S6 G ' TU Plus TU P I Tile Pro Dual Pro TU Max NITS Plus �, inter Haven, FL 180 90 180 180 180 186 180 180 180 azelton, PA N/A 90 N/A 180 N/A I N/A N/A 180 N/A 7�, All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and NOA No.: 17-0614.22 rtwM�raaneCoutl7�r Expiration Date: 09/13/21 I Approval Date: 07/06/17 8.1 Rule 61 G20-3 of the Florida Administrative Code. In roof the application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof file applications_ Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope shall be as follows: (See Table Below) Tile Polystick Elastoflex Polystick TU Plus, Polystick Polystick System (E3) Profile MTS S6 G TU P, Tile Pro, TU Max MTS Plus MTS Plus with Dual Pro TU Plus lat Tile Prohibited 412 6:12 6:12 5:12 6:12 without battens rofiled Prohibited 4:12 6:12 6:12 4:12 6:12 ile without battens I The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall be utilized during loading and installation of tiles. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for all underlayments except Polystick MTS which shall be loaded onto battens. N N©A No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANTS j PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1JI Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to, refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2.All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %11 metal disk as required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on j the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3.1 All seal lap seams (selvage laps) must be rolled with a hand roller to ensure fall contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. J Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6 ''/a"/12% precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7.1 Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. , Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. All approved substrates should be dry-, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 8944563_ Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK wITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17