BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
m
{u
MAR 2 2 2019
Permitting Department
St. Lucie County, FL
k i Permit #: t g O "1 - 0-1 ItLf_
Job Add ess: 165 I %3 C_& v fir, A ^s F f - Ole -cam, F C 3 `� `f�.
Construll :tion: (XN ew Construction — Complete ( ) Existing —After Addition
House Ifiltration Test Results SLC Climate Zone 2
CFM (50 = I g-X-"j Test Date: '7 f z l
Volume �7 �( Ok
ACH (50, = CFM (50) x 60 / Volume = , 33 3 Mechanical Ventilation required less than 3 ACH
Passing esuits must be & ACH (50) or less ass ( ) Fail
FBC, Enen'
The build g or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Cl ate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower d ! r at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 5 3.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an
approved) tthird party. A written report of the results of the test shall be signed by the party conducting the test and
provided the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal a velope.
FBC, Resi 'ential
Where th air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure c 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelli �1'g unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testine Com Dan
Company I ame: Pro -Duct Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby c rtify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirem is in accordance with Section 02.4.1.2 Climate Zone 2.
Signature: ! ' `
Printed N ! e: Martin Klein
#: 5061633