HomeMy WebLinkAbout1404-0377-HVAC LOAD CALCULATION 4-17-14NED
BY
ewow. W,
Rizk Residence
HVAC Load Calculations
for
, Rizk
Lot 1234 Nettles Blvd.
Ft. Pierce, Florida
RHVACHVAC LOADS
Prepared By:
Residential Energy Calc's
Thursday, April 17, 2014
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations Tare performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac R sideetial & Light Commercial HVAC Loads "` Elits Software Development, Inc.
-AL
Residential ;Energy CUds- Rizk Residence
Tort -Saint Lwcie; FL 34983
J,Proied,t Report
.General Pco'ei t 1pformation
Project Ti
e: Rizk Residence
Designed
y: QEA Associates
Project D
te: Wednesday, April 16, 2014
Client Na
e: Rizk
Client Ad
"press: Lot 1234 Nettles Blvd.
Client Ci
Ft. Pierce, Florida
Company
ame: Residential Energy Calc's
Referenc
'J City: Fort Pierce, Florida
Building Orientation:
Front door faces East
Daily Tem
erature Range: Medium
Latitude:
j 27 Degrees
Elevation:
25 ft.
Altitude F
' tor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb ReLHum Rel.Hum Dry Bulb Difference
Winter:
I 42 39.4 n/a n/a 70 n/a
Summer:
I 90 78 59% 50% 75 61
I
Check.Fi
Total Build,
g Supply CFM: 1,267 CFM Per Square ft.: 0.819
Square ft.
Of Room Area: 1,547 Square ft. Per Ton: 518
Volume
of Cond. Space: 12,376
x
Total Heati
g Required Including Ventilation Air: 26,790 Btuh 26.790 MBH
Total Sens
�le Gain: 28,251 Btuh 79 %
Total Late
Gain: 7,558 Btuh 21
Total Cooli
g Required Including Ventilation Air: 35,809 Btuh 2.98 Tons (Based On Sensible + Latent)
i
'Notes
R
Rhvac is a
ACCA approved Manual J and Manual D computer program.
Calculation
are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All comput
results are estimates as building use and weather may vary.
Be sure to
elect a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design'
conditions.
i
i
I
i
I
I
I
I
I
i
i
I
i
C:\ ...\Rizk R11i idence.rh9 Thursday, April 17, 2014, 8:58 AM
RnVaC R�SIgenUal 6 Lignt Gommerclal HVAG Loans Elite Software Development, Inc.
Residential Energy Calc's Rizk Residence
Port Saint Lucie. FL 34983 Pa4e'3
In ut Date
D `Bulb
Wet Bulb r
Rel Hum-ReLHum = Dry':Bulb. ;Difference
Winter:
42
39.4
80% n/a 70 n/a
Summer:
90
78
59% 50% 75 61.09
Duct Sizidd
Inputs
Main Trunk
Runouts
Calculate:
Yes
Yes
Use Sche
ule:
Yes
Yes
Roughnes`
Factor:
0.00300
0.01000
Pressure
rop:
' 0.1000
in.wg./100 ft.
0.1000
in.wg./100 ft.
Minimum
elocity:
650
ft./min
450
ft./min
Maximum
I elocity:
900
ft./min
750
ft./min
Minimum
eight:
0
in.
0
in.
Maximum
eight:
0
in.
0
in.
Outside Aifi
Data
Winter
Summer
Infiltration
pecined:
0.380 AC/hr
0.200 AC/hr
ilctual:
78 CFM
41 CFM
Infiltration
0.360 AC/hr
0.159 AC/hr
Above Grail
a Volume:
X 12,376 Cu.ft.
X 12,376 Cu.ft.
4,457 Cu.ft./hr
1,969 Cu.ft./hr
I,
X 0.0167
X 0.0167
Total Build
ng Infiltration:
74 CFM
33 CFM
Total Buildi l g Ventilation:
25 CFM
25 CFM
I
--Syste 1---
Infiltration Ventilation Sensible
Gain Multiplier: 16.49 =
(1.10 X 0.999 X 15.00 Summer Temp. Difference)
Infiltration Ventilation Latent Gain Multiplier: 41.50 =
(0.68 X 0.999 X 61.09 Grains Difference)
Infiltration Ventilation Sensible
Loss Multiplier: 30.77 =
(1.10 X 0.999 X 28.00 Winter Temp. Difference)
Winter Infil ation Specified:
0.380 AC/hr (78 CFM), Construction: Average
Summer In Itration Specified:
0.200 AC/hr (41 CFM), Construction: Average
Duct toad ,actor Scenarios for ,S stem 4. .
No. T pe
'
} Description`
Attic
Location '' Ceilin
Duct Ductij Surface From
Leaks e • Insulation Area ` MDD"
1 Suppl Attic 16B 0.12 6 397 No
1 Retur, Attic 16B 0.12 6 220 No
Q\ ...\Rizk Re'$idence.rh9 Thursday, April 17, 2014, 8:58 AM
Load Preview
Repolf
Net
ft.2
Sen
Lat
Net
Sen
Sys
Sys
S
ClCFM lg
Sys
Act
Duct
Scope
Ton
/Ton
Area
Gain
Gain
Gain
Loss
CFM1
CAM
Size
Building
2.98 5181
1,547.
28,251
7,568
35,8091
26,790
338' 1267
1267
System 1
-
-- --- -- -- - - --- ----- - - - -------- ----- ----
2.981 5181
---
1,547
. - --.-
28,251
4 -- - -
7,5581
35,809
�I 26,790
3382M 1,267,
—
1208
- - ------- -----
Ventilation I i
412,
- ---------
1,038!
.---j
1,4501
-------- - -----
769.
--- ----
--- .. .
Duct Latent
-- -- ------ ---
1,460;
1,460,
Zone 1 - Cl
-- ------- - ------
45OX, g': Ht 46%
0
--
724:
----- - ---------------
14,7501
--- -- ------------
2,069!
16,819.
----------
12,0271
.. .....
156
- ------ ------
671-;---1
-----
0x1 3.
320
9,929!
866;
10,795
6,396,
81,
4521
5-6
2-Dinin9
95'-----342.
346
688,
611,
-- 81
16-'— -1-4
3-Living
176,
3,722,
474
4,196.;_
3,800:
169
2-5
4-Stairway
77,
307
461
353.
565
_49:
14
1-4
5-Foyer I
-------- --- ---
1 57':
451
337,
788
6571 9
201 1-4
Zone 2 - Cig
--------- --
55%, Htg..- 54%
823
17,901
2,991
, 20,892
13,994-
1821
8141
1 Ox1 6
6-Bath2
77
1253'
438
1,691
1
20�
57
1-4
7-Master
h
126:
988
438:
1,426:
1,647:
21,
45,
1-4
8-Masteffr
room
272:
4,996
746
5,742,
5,032,
W
227:
3-5
9-Walk In C oset
.... ......... .
42
238
46i
284
i 477:
---- -- ---- -
6
11
1-4
10-Bedroo !2
182 3286.
677
3,963
.2,829 37i
150
2-5
11-Laundry
54�
108:
600
i 708.
1371
21
5
1-4
12-Stairway
M 7,033 46, 7,079, 2,306; 3011,
320. 3-6
Sum of room
irflows may be greater than system airflow because
.... ......
system has m
tiplezones.
C:X ... \Rizk R�,Oidence.rhEl Thursday, April 17, 2014, 8:58 AM
Duct Size
Preview
Room or
Minimum mum
Maximum
Rough.
Design
SP
Duct
Duct
Htg
Cig
Act.
Duct
Duct Name
Velocity
Velocity
Factor
L/100
Loss
Velocity
Length
Flow
Flow
Flow
Size
System
'u outs SUPP,Y '
-1- .
- -- ------
- --- - ---- ----
- --- -----
-- --- -------
--------- -
..... ------- --------- - -- ------------
---- - --- -
Zone,
--------
1-Kitchen
--
Built-in
--- - ----- -
450
750
0.01'
--------- ----- - -
0.1
--- ---
460.1
83j
452
5-6
2-Dining
Built -In
450
750
0.01;
- ----------- -
0.11
178.1:
81
------
16:
1-4
3-Livin
I Built-in
450
750,
0.01
0.1.
621
49
169'
2-5
4-Stairwa
Built-in
450
750,
0.01
0.1
160.2-
71
14-
1-4
5-Foyer I
Built -In
450
750:
0.01
0.1 234.91
9
20'
1_4
Zone 2
.... .... ... . ..
6-Bath2
Built-in
----------
450'
750
0.01
0.1,
653
20
57
1-4
7-Master ath
Built-in
460
760
0.01
0.1
515.1.
21
45'
1-4
..... . ... .. . ................
8-Master edroorn
Built -In
450,
. ... ..
750
0.01
.............
0.1
..... ......... .. .. . ..- -
555.6:
66
227
3-5
9-Walk In loset
Built-in
------------------- -
450
- -- -------- ------------
750
001
0.1
123.81
6!
ill
1-4
----------- --
1D-Bedro 2
Bdlt-In--'
450 750.
0.01,
0.1
548.3,
37M
150
2-5
1 I-Laund
Built -In
450
750
Ul
0.1,
56.2;
-- -- ------
2,
^
1-4
I 2-Stairw f
Built-in
450
750'; ODI'
0.1
543.2,
WE
320
3-6
Other, Ducts In System I
-
Supply Ma 9 Trunk
Built-in
650
900.
0.003
0.1
844.41
338
1.267t
1208
Summary
System
Heating_ FI
338
Cooling Flo
. 1267
C:\ ... \Rizk Reoidence.rhE) Thursday, April 17, 2014; 8:58 AM
i
Rhvac = R
`sidential;& Light Commercial HVAC Loads ,,
-,
Elite SoHware Development, Inc.
Risitlential(Energy
Calc's
Rizk Residence
PortSaint
L'ucie FL 34983`
Fa e 6
Total 430ding
Summaq Loads
mpon
��
`` x�Yk'}� '' +(x.. e� iU 5..,, e - ; t �, . <�. .. , WS6
nt ad�n� �1 ArealeLaf `` SWTOte&
fy,' e'ti �.,IN
,.
?..�. :z iQuanN.oss
Gainws �•
Gains.ain
1A-cb-o: ,lazing -Single 'pane, operable window, clear, 170.8
5,161 0
6,115 6,115
metal came with break, u-value 1.08, SHGC 0.75
1A-cm-o: lazing -Single pane, operable window, clear, 117.5
4,179 0
8,606 8,606
metal r ame no break, u-value 1.27, SHGC 0.75
7A-1: Glaz �g-Glass or plastic block, smooth or wide ribs 4
68 0
286 286
or flut no screen, no coating, u-value 0.6, SHGC
0.65
11 D: Door ood - Solid Core 42
352 0
336 336
13A-5ocs: all -Block, board insulation only, R-5 board 1144.3
4,006 0
2,191 2,191
insulat on, open core, siding finish
12E-Osw: part -Frame, R-19 insulation in 2 x 6 stud cavity, 91
93 0
93 93
no board insulation, siding finish, wood studs
12E-0sw: all -Frame, R-19 insulation in 2 x 6 stud 88
168 0
104 104
cavity, '� o board insulation, siding finish, wood studs
16C-30: R Qf/Ceiling-Under Attic with Insulation on Attic 1547
1,387 0
1,982 1,982
Floor ( Iso use for Knee Walls and Partition
Ceiling'), Vented Attic, No Radiant Barrier, White or
Light C for Shingles, Any Wood Shake, Light Metal,
Tar an Gravel or Membrane, R-30 insulation
20P-30: Floe r-Over open crawl space or garage, Passive, 1547
1,516 0
542 542
R-30 bl nket insulation, any cover
Subtotals f
r structure:
16,930 0
20,255 20,255
People: i
2
400
460 860
Equipment
3,300
600 3,900
Lighting:
0
0 0
Ductwork:
I
6,805 1,460
5,984 7,444
Infiltration:
inter CFM: 74, Summer CFM: 33
2,286 1,360
540 1,900
Ventilation:,Winter
CFM: 25, Summer CFM: 25
769 1,038
412 1,450
Total Buildi'i
g Load Totals:
26,790 7,558
28,251 35,809
Check.Ei ores
r$„,F,t . _;..� u,•s:�_'�� •,x„;F . ��4t
Total Buildi
g Supply CFM: 1,267 CFM Per Square ft.:
0.819
Square ft. 0'Room
Area: 1,547 Square ft.
Per Ton:
518
Volume (ft3)'iof
Cond. Space: 12,376
-
Bwldm Loads
r :.y is,l yC 'C3�fi r h� {-:iM1 .v z'` s\} _s.�k t \ �'y.� 3 }y,+i yr, !'tt
d ,. ,�. , , r ,.,..r, ..L dK ...: i � . �7`";u �tw d�•'�`r.. 1 .:.h` s ,:. :,. _3 `G:.,�� r a ., C,1;� td. _Fu��s•x :'�Y,,€,'�rt�-^n5".?h
Total Heating Required Including Ventilation Air: 26,790 Btuh
26.790 MBH
Total Sensi �le Gain: 28,251 Btuh
79 %
Total Latent ;Gain: 7,558 Btuh
21 %
Total CoolinRequired Including Ventilation Air: 35,809 Btuh
2.98 Tons (Based On
Sensible + Latent)
Notes: k��5 c 2 , �
• .. rt.."4M1.. .. .. ... .. r$5 4 ... ' .. : , ^<:JSf .. h. n . •Mi%'4�d ..'!1 e.. e ,k :A to
'• 9:1,•::., N "i:--::
Rhvac is an' CCA approved Manual J and Manual D computer program.
Calculations i re performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All compute results are estimates as building use and weather may vary.
Be sure to s lect a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design onditions.
i
i
i
i
I
I
i
i
i
i
C:\ ...\Rizk Reiidence.rh9 Thursday, April 17, 2014, 8:58 AM
Rhvac Residential
& Light Commercial,HVAC Loads
Elite Software Development, Inc:
Residential IlEnergy
Calc's
$izk Residence
Port Saint Lucie;
FL 34983
Page" 8,
-Detail 'd
Room Loads -Room 9 - Kitchen .(Peak Fenestration Gain Procedure)
General.
��fn�,�a�� �';�
s >a{ .- nr.�..
y*'��';�'����� '.�.::.
;N:�•
�..n���,`�.�����*a�
Room is i
zone 1, which peaks at 2 pm
Calculatio
Mode: Htg. & clg.
Occurrences:
1
Room Le ;gth:
20.0 ft.
System Number:
1
Room Wi the
16.0 ft.
Zone Number:
1
Area:
320.0 sq.ft.
Supply Air:
452 CFM
Ceiling He
ght:
8.0 ft.
Supply Air Changes:
10.6 AC/hr
Volume:
2,560.0 cu.ft.
Req. Vent. Clg:
0 CFM
Number o
Registers:
5
Actual Winter Vent.:
6 CFM
out RunAi l
90 CFM
Percent of Supply.:
1 %
Runout D
ct Size:
6 in.
Actual Summer Vent.:
8 CFM
Runout Ai ;IVelocity:
460 ft./min.
Percent of Supply:
2 %
Runout Ai ;
Velocity:
460 ft./min.
Actual Winter Infil.:
15 CFM
Actual Los
:
0.136 in.wg./100
ft.
Actual Summer Infil.:
6 CFM
�ItefDescnptlo,
.• K
.
Uk
• Htg` Sen
CIg
fflatn:
:-,rs
Quantira
ain p -
Gain:
E -Wall-13 '-5ocs
18 X 8
131
0.125
3.5 459
1.9
0
251
SE-Wall-13
4I-5ocs
-5ocs 11 X 8
53
0.125
3.5 186
1.9
0
101
S -Wall-13
11.5 X 8
50
0.125
3.5 175
1.9
0
96
E -GIs-1A-
-0 ShgC-0.75 0%S
9
1.080
30.2 272
76.7
0
690
SE-GIs-1A-��m-o
shgc-0.75 0%S
35
1.270
35.6 1,245
80.2
0
2,806
E -GIs-7A-1
shgc-0.65 0%S (2)
4
0.600
16.8 68
61.5
0
246
S -GIs-IA-c
-o shgc-0.75 0%S (2)
24
1.080
30.2 726
64.1
0
1,538
S -GIs-IA-q
-o shgc-0.75 0%S
18
1.080
30.2 544
64.1
0
1,153
UP-Ceil-16
-30 20 X 16
320
0.032
0.9 287
1.3
0
410
Floor-20P-3
' 16 X 20
320
0.035
1.0 314
0.4
0
112
Subtotals fo
Structure:
4,276
0
7,403
Infil.: Win.:
.5, Sum.: 6.4
324
1.380 447
0.327
266
106
Ductwork:
1,673
1,820
Equipment:
!
600
600
Room Total
:
I
I
i
I
I
I
i
I
i
I
I
I
I
6,396
866
9,929
C:\ ...\Rizk R�SiidencexhGl Thursday, April 17, 2014, 8:58 AM
Rhvac Residential & Light Commercial HVAC Loads
„'
Elite Software Development, Inc.
Residential Energy Calc's , ,
Rizk Residence'
Port Saint Ucie, FL 34983
?age 9
,Detail .';d Room Loads - Room 2 - Dining (Peak Fenestration Gain -Procedure)
Room is i zone 1, which peaks at
2 pm
Calculatio,, Mode:
Htg. & clg.
Occurrences:
1
Room Le the
13.5 ft.
System Number:
1
Room Width:
7.0 ft,
Zone Number:
1
Area: I�
94.5 sq.ft.
Supply Air:
16 CFM
Ceiling H ght:
8.0 ft.
Supply Air Changes:
1.2 AC/hr
Volume.
756.0 cu.ft.
Req. Vent. Clg:
0 CFM
Number o Registers:
l
1
Actual Winter Vent.:
1 CFM
Runout Ai f
16 CFM
Percent of Supply.:
4 %
Runout D ct Size:
4 in.
Actual Summer Vent.:
0 CFM
Runout Ai Velocity:
178 ft./min.
Percent of Supply:
2 %
Runout Aii< Velocity:
178 ft./min.
Actual Winter Infil.:
3 CFM
Actual Lo;.:
0.038 in.wg./100 ft. Actual Summer Infil.:
1 CFM
"Item; `'
Area
11" �: Fltg " Seri _
Clg
Ltat
Send
(Description: _ , ,
Quantity
S -Wall-13 -5ocs 7 X 8
56
0.125 3.5 196
1.9
0
107
UP-Ceil-16 ° -30 13.5 X 7
94.5
0.032 0.9 85
1.3
0
121
Floor-20P- 0 7 X 13.5
94.5
0.035 1.0 93
0.4
0
33
Subtotals f
Structure:
374
0
261
Infil.: Win.:
.5, Sum.: 1.1
56
1.375 77
0.321
46
18
Ductwork: I
160
63
Equipment:
300
0
Room Total!:
I
I
I
i
i
I
I
I
i
I
I
I
I
I
I
i
i
I
I
i
I
i
611
346
342
C:\ ...\Rizk Rlpidence.rh9 Thursday, April 17, 2014, 8:58 AM
13hvacr Residential & Light Commercial HVAC Loads " `
Elite Software Development, Inc.
Residential IEnergy Calds
Ri2k
Residence ;
Port,:Saint Lucie, FL, 34983
P.a a 10
Ntai! " d Room Loads - Room 3 - Living. (Peak Fenestration Gain Procedure)
,General
Room is izone 1, which peaks
at 2 pm
CalcuI ti Mode:
Htg. & clg.
Occurrences:
1
Room Le gth:
13.5 ft.
System Number:
1
Room Wi the
13.0 ft.
Zone Number:
1
Area:
175.5 sq.ft.
Supply Air:
169 CFM
Ceiling H 'ight:
8.0 ft.
Supply Air Changes:
7.2 AC/hr
Volume: I
1,404.0 cu.ft.
Req. Vent. Clg:
0 CFM
Number o Registers:
2
Actual Winter Vent.:
4 CFM
Runout Ai :
85 CFM
Percent of Supply.:
2 %
Runout D 'ct Size:
5 in.
Actual Summer Vent.:
3 CFM
Runout Ai Velocity:
621 ft./min.
Percent of Supply:
2 %
Runout Ak Velocity:
621 ft./min.
Actual Winter Infil.:
10 CFM
Actual Lo
0.317 in.wg./l00 ft.
Actual Summer Infil.:
4 CFM
r Area
, UW'Hjfg ' Sen..Wf
tom,Quantit
g
Lat
Value .,TM Loss
S -Wall-13 ;'-5ocs
13 X 8
50 0.125
3.5 175
1.9
0
96
W -Wall-13
1 -5ocs 13.5 X 8
108 0.125
3.5 378
1.9
0
207
S -GIs-1A-
�-o shgc-0.75 94%S
(3) 54 1.080
30.2 1,632
44.1
0
2,382
UP-Ceil-16
-30 13.5 X 13
175.5 0.032
0.9 157
1.3
0
225
Floor-20P-
,,0 13 X 13.5
_ 1_75.5 0.035
1.0 172
0
Subtotals f ,
Structure:
2,514
_0_.4
0
_61
2,971
Intl.: Win.:
A Sum.: 4.2
212
1.377 292
0.325
174
69
Ductwork:
994
682
Equipment:;
300
0_
Room Total
:
I�
I
I
I
I
I
I
4
i
i
I
i
I
I
I
i
i
I
i
I,
I
I
I
I
3,800
474
3,722
C:\ ...\Rizk R�isidence.rh9 Thursday, April 17, 2014, 8:58 AM
11
Rh4ac - Residential &Light Commercial HVAC Loads
Elite Software Development, Inc:
Resident+at�Energy Calds
Rizk Residence
Port Saint Lucie, FL 34983
"
Page 11
;Detail ''d Room Loads - Room 4 - Stairway (Peak Fenestration' Gain Procedure)
Room is i
zone 1, which
peaks at 2 pm
Calculatio"
Mode:
Htg. & clg.
Occurrences:
1
Room Le
"
the
11.0
ft.
System Number:
1
Room Wi
th:
7.0
ft.
Zone Number:
1
Area:
77.0
sq.ft.
Supply Air:
14 CFM
Ceiling H sight:
8.0
ft.
Supply Air Changes:
1.4 AC/hr
Volume: '
616.0
cu.ft.
Req. Vent. Clg:
0 CFM
Number o
Registers:
1
Actual Winter Vent.:
1 CFM
Runout Ai
14
CFM
Percent of Supply.:
4 %
Runout D
act Size:
4
in.
Actual Summer Vent.:
0 CFM
Runout Aid
Velocity:
160
ft./min.
Percent of Supply:
2 %
Runout Ai
Velocity:
160
ft./min.
Actual Winter Infil.:
3 CFM
Actual Lo
0.031
in.wg./100 ft. Actual Summer Infil.:
1 CFM
Item K H
y ; 5
Area
U Ht `'
Clg
Lat Send
y Azr
Desenption
, p .„,
Quantit y .
Val. 41-, , H itM Loss.
HTIM
Gain;
;Gain
W -Wall-13, -5ocs 7 X 8
56
0.125 3.5 196
1.9
0
107
UP-Ceil-16 -30 11 X 7
77
0.032 0.9 69
1.3
0
99
Floor-20P- 0 7 X 11
77
0.035 1.0 75
0.4
0
27
Subtotals f
Structure:
340
0
233
Infil.: Win.:
.5, Sum.: 1.1
56
1.375 77
0.321
46
18
Ductwork:
148
56
Room Total'
:
i,
i
i
I
i
i
i
i
I
i
I
i
I.
I
I
i
i
i
i
i
i
I
565
46
307
C:\ ...\Rizk R iidence.rhg Thursday, April 17, 2014, 8:58 AM
Rhvac - Residential
& Light Commercial HVAC Loads
Elite Software Development, Inc.
Residential
Energy Ca(c's
Riik Residence
Port`Saint'�ucie,
FL 34983'
Pa a 12
Detail'
d Room Loads.= Room 5 - Foyer
(Peak Fenestration Gain Procedure)
General
'XT
_ ��,, �i'f�����'��u'
AM
Room is i' zone 1, which peaks at 2 pm
Calculati �L Mode:
Htg. & clg.
Occurrences:
1
Room Leogth:
10.0 ft.
System Number:
1
Room Withe
5.7 ft.
Zone Number:
1
Area:
57.0 sq.ft.
Supply Air:
20 CFM
Ceiling H ight:
8.0 ft.
Supply Air Changes:
2.7 AC/hr
Volume:
456.0 cu.ft.
Req. Vent. Clg:
0 CFM
Number o Registers:
1
Actual Winter Vent.:
1 CFM
Runout A� :
20 CFM
Percent of Supply.:
3 %
Runout D' ct Size:
4 in.
Actual Summer Vent.:
0 CFM
Runout AilI Velocity:
235 ft./min.
Percent of Supply:
2 %
Runout Ai,l Velocity:
235 ft./min.
Actual Winter Infil.:
2 CFM
Actual Lo s:
0.064 in.wg./100 ft. Actual Summer Infil.:
1 CFM
Items ,-,
t „u "� . � .,
`Arelow
��nJ�RJR
*�.enj@%—lg�,�@—at�S,lue. , , TM .
IM
E -Wall-13
,� -5ocs 5.7 X 8
24.6
0.125 3.5 86
1.9
0
47
E -Door-11
3 X 7
21
0.390 10.9 229
10.1
0
213
UP-Ceil-161
-30 10 X 5.7
57
0.032 0.9 51
1.3
0
73
Floor-20P-
"0 5.7 X 10
57
0.035 1.0 56
0.4
0
20_
Subtotals f
r Structure:
_
422
_
0
353
Infil.: Win.:
, .0, Sum.: 0.9
46
1.382 63
0.329
37
15
Ductwork:
172
83
Equipment:!
300
0
Room Total
_
i
i
i
I i
I
I
i
i
i
i
i
I
i
i
i
i
I
i
I
i
i
I,
657
337
451
C:\ ...\Rizk R�I idence.rh9 Thursday, April 17, 2014, 8:58 AM
Rhvac R 'm sidential 4i Light Comerclal.HVAC Loads
Elite Software Development, Inc.
Residenti4jEnergy Calc's,,
Rizk Residence
Port Saint 'ucie, FL 34983
Fa a 13
Detail ";d Room Loads =Room 6 - Bath2 (Peak Fenestration Gain Procedure)
�..
General, �
-
4
j
Room is i'
zone 2, which peaks at 5 pm
Calculatiop
Mode:
Htg. & clg.
Occurrences:
1
Room Le ;gth:
11.0 ft.
System Number:
1
Room Wi
the
7.0 ft.
Zone Number:
2
Area:
77.0 sq.ft.
Supply Air:
57 CFM
Ceiling H light:
8.0 ft.
Supply Air Changes:
5.6 AC/hr
Volume:
616.0 cu.ft.
Req. Vent. Clg:
0 CFM
Number o
Registers:
1
Actual Winter Vent.:
2 CFM
Runout Ai
:
57 CFM
Percent of Supply.:
3 %
Runout D
Size:
4 in.
Actual Summer Vent.:
1 CFM
Runout Ail
Ict
Velocity:
653 ft./min.
Percent of Supply:
2 %
Runout Air
Velocity:
653 ft./min.
Actual Winter Infil.:
8 CFM
Actual Lo
P:
0.479 in.wg./100 ft.
Actual Summer Ill
3 CFM
Area
U="
HtgFAII' ' Sen
Clg
L�at
Sen
Descn tion,�,::
Quanfii
Value ;
HTMLoss
HTM
Gain
Gain
N -Wall-13 ,,-5ocs 7 X 8
42.2
0.125
3.5 148
1.9
0
81
SW-Part-1 i0/15°-12E-Osw 14 X 8
91
0.068
1.0 93
1.0
0
93
SW-Door-1 D 3 X 7
21
0.390
5.9 123
5.9
0
123
N -GIs-1A- -o shgc-0.75 7%S
13.8
1.080
30.2 417
39.5
0
545
UP-Ceil-I6E -30 11 X 7
77
0.032
0.9 69
1.3
0
99
Floor-20P- 3 7 X 1.1
77
0.035
1.0 75
0.4
0
27
Subtotals f4
Structure:
925
0
968 ,
Ill Win.:
.5, Sum.: 3.3
168
1.381 232
0.327
138
55
Ductwork:
410
230
Equipment:
360
0
Room Total
-
i
I
I
I
I
I
I,
i
i
I
I
i
,I
I
it
I
I
1,567
438
1,253
C:1... \Rizk RI ridence.rh9 Thursday, April 17, 2014, 8:58 AM
Rhvac R sidential& Light Commercial HVAC Loads
Elite Software Development, Inc.;
Resident�a Energy Calc's
Rizk Residence
Port.Samt - cie, FL 34983 - : ,
Pa a 14 ,
Detail ' d Room Loads'- Room 7 - Master Bath (Peak Fenestration Gain Procedure)
Room is i ,
zone 2, which peaks at
5 pm
Calculati
Mode:
Htg. & clg.
Occurrences:
1
Room Le ,gth:
14.0 ft.
System Number:
1
Room Wi
the
9.0 ft.
Zone Number:
2
Area:
126.0 sq.ft.
Supply Air:
45 CFM
Ceiling H ight:
8.0 ft.
Supply Air Changes:
2.7 AC/hr
Volume: 1,1,008.0
cu.ft.
Req. Vent. Clg:
0 CFM
Number o j
Registers:
1
Actual Winter Vent.:
2 CFM
Runout Ai
:
45 CFM
Percent of Supply.:
4 %
Runout D '
ct Size:
4 in.
Actual Summer Vent.:
1 CFM
Runout Ai
Velocity:
615 ft./min.
Percent of Supply:
2 %
Runout Ai'
Velocity:
515 ft./min.
Actual Winter Infil.:
8 CFM
Actual Lo
s:
0.300 in.wg./100 ft.
Actual Summer Infil.:
3 CFM
}Desch tlo-
�..•. �.:
Quantity Value :
HTM , Loss
HTM
Gai'n., � _Gam.,:
N -Wall-13 ,I -5ocs 6 X 8
42 0.125
3.5 147
1.9
0
80
E -Wall-1 -5ocs 15 X 8
120 0.125
3.5 420
1.9
0
230
N -GIs-1A- -o shgc-0.75 15%S
6 1.080
30.2 181
39.5
0
237
UP-Ceil-16 -30 14 X 9
126 0.032
0.9 113
1.3
0
161
Floor-20P- 0 9 X 14
126 0.035
1.0 123
0.4
0
44
Subtotals f ,F Structure:
_ _
_
984
_
0
752
Infil.: Win.: 5, Sum.: 3.3
168
1.381 232
0.327
138
55
Ductwork:
431
181
Equipment:
300
0
Room Total
:
I
i
i
I
I
i
i
i
I
I
i
i
i
i
i
i
i�
i
i
I
i
i
i
I
i
i
1,647
438
988
C:1... 1Rizk Re6idencexh9 Thursday, April 17, 2014, 8:58 AM
1111
Rhvac m Residential & Light Commercial HVAC Loads
Elite Software Development,' Inc.
Residential; Energy Calc's .. ; ;
_
"
Rizk Residence
'Port Saint Lucie FL 34983
_
Pa a 15
De#ai' "d
Room Loads - Room 8 - Master-. Bedroom (Peak Fenestration Gain
Proce
ure)
01
General
_ . y # _
,, f.,�ar : fElP,�xF
Room is i zone 2, which peaks at 5 pm
Calculati h Mode: Htg. & clg.
Occurrences:
1
Room Le gth:
17.0 ft.
System Number:
1
Room Wi the
16.0 ft.
Zone Number:
2
Area:
272.0 sq.ft.
Supply Air:
227 CFM
Ceiling H light:
8.0 ft.
Supply Air Changes:
6.3 AC/hr
Volume: 1
2,176.0 cu.ft.
Req. Vent. Clg:
0 CFM
Number of Registers:
3
Actual Winter Vent.:
5 CFM
Runout Al :
76 CFM
Percent of Supply.:
2
Runout D ct Size:
5 in.
Actual Summer Vent.:
4 CFM
Runout Ai Velocity:
556 ft./min.
Percent of Supply:
2 %
Runout Ai Velocity:
556 ft./min.
Actual Winter Infil.:
13 CFM
Actual Lo
0.254 in.wg./100 ft.
Actual Summer Infil.:
6 CFM
Itemai���
y Area .lJ= Htg Sen
,CO
Lat
Sen
De'scnptio , ;,` ,.. ,.
Quantity Value,
, .. HTM_ Loss. `
HT,M
GamF;_
x. Gain,..
NE-Wall-1 A-5ocs 14 X 8
70 0.125
3.5 245
1.9
0
134
S -Wall-13 12.5 X 8
80 0.125
3.5 280
1.9
0
163
,-5ocs
SE-Wall-1 E-Osw 11 X 8
88 0.068
1.9 168
1.2
0
104
NE-GIs-1A'�m-o shgc-0.75 0%S
42 1.270
35.6 1,494
47.2
0
1,984
S -GIs-1A -o shgc-0.75 O%S (2)
20 1.080
30.2 604
46.7
0
934
UP-Ceil-16 �� -30 17 X 16
272 0.032
0.9 244
1.3
0
348
Floor-20P- 16 X 17
272 0.035
1.0 267
0.4
0
95
Subtotals f4
Structure:
3,302
0
3,752
Infil.: Win.:
3.4, Sum.: 5.9
300
1.380 414
0.327
246
98
Ductwork:
1,316
916
People: 20
lat/per, 230 sen/per:
1
200
230
Equipment:1
300
0
Room Total'
:
i
i
I
i
i
I
i
i
I
I
I
i
i
i
i
I
i
I
i
I
i
5,032
746
4,996
C:\ ...\Rizk Re�!dence.rh9 Thursday, April 17, 2014, 8:58 AM
Rhvac Residential;& LightCommercial HVAC Loads
'
'Elite SoflwareDevelopment, Inc.,
Res idential`Energy Calds
Rizk Residence
Port.Saint, Lucie, FL 34983 ,
Page 16 .
Detail,, d.Room Loads - Room 9 - Walk In. Closet (Peak Fenestration Gain
,Proce ',, ure)
Bryn°� . �
,.
� " xxMINNIN
R
Room is I zone 2, which peaks at 5 pm
Calculati n Mode:
Htg. & clg.
Occurrences:
1
Room Legth:
7.0 ft.
System Number:
1
Room Wi'.th:
6.0 ft.
Zone Number:-
2
Area:
42.0 sq.ft.
Supply Air:
11
CFM
Ceiling H ight:
8.0 ft.
Supply Air Changes:
1.9
AC/hr
Volume: j
336.0 cu.ft.
Req. Vent. Clg:
0
CFM
Number o, Registers:
1
Actual Winter Vent.:
0
CFM
Runout Air:
11 CFM
Percent of Supply.:
4
%
Runout D' ct Size:
4 in.
Actual Summer Vent.:
0
CFM
Runout Ai Velocity:
124 ft./min.
Percent of Supply:
2
%
Runout Al, Velocity:
124 ft./min.
Actual Winter Infil.:
3
CFM
Actual Lo is:
0.019 in.wg./100 ft.
Actual Summer Infil.:
1
CFM
S -Wall-13'
-5ocs 7 X 8
56 0.125
3.5 196
1.9
0
107
UP-Ceil-16
-30 7 X 6
42 0.032
0.9 38
1.3
0
54
Floor-20P-
0 6 X 7
42 0.035
1.0 41
0.4
0
15
Subtotals f
r Structure:
275
0
176
Infil.: Win.:
.5, Sum.: 1.1
56
1.375 77
0.321
46
18
Ductwork: I
125
44
Room Tota
i
I
i
i
i
i
i
.I
i
I
i
i
I
i
I
I
I
I
i
i
i
i
i
i
i
I
i
i
1
477
46
238
C:\ ...\Rizk Re�idence.rh9 Thursday, April 17, 2014, 8:58 AM
Rhvac Residential & Light Commerclal HVA_ C Loads
Elite Software Development, Inc. '
Residential Energy Calds
Rizk Residence
-Port Saint. Eucie, FL 34983
Pa a 17.
Detail `' d Room Loads - Room 10 - Bedroom 2 (Peak Fenestration Gain Procedure)
Room is i zone 2, which peaks at
5 pm
Calculate Mode:
Htg. & clg.
Occurrences:
1
Room Le ' gth:
14.0 ft.
System Number:
1
Room Withe
13.0 ft.
Zone Number:
2
Area:
182.0 sq.ft.
Supply Air:
150 CFM
Ceiling H 'fight:
8.0 ft.
Supply Air Changes:
6.2 AC/hr
Volume: i
1,456.0 cu.ft.
Req. Vent. Clg:
0 CFM
Number o Registers:
2
Actual Winter Vent.:
3 CFM
Runout Al :
75 CFM
Percent of Supply.:
2 %
Runout D ct Size:
5 in.
Actual Summer Vent.:
3 CFM
Runout Ai Velocity:
548 ft./min.
Percent of Supply:
2 %
RunoutAi'Velocity:
548 ft./min.
Actual Winter Infil.:
10 CFM
Actual Lo s:
0.248 in.wg./100
ft.
Actual Summer Infil.:
4 CFM
Items
"
Descri twn.r.,
,
Quantity
value
HtTM Loss
HTM
Gain.;
Gain.
S -Wall-13 -5ocs 13 X 8
84
0.125
3.5 294
1.9
0
161
W -all-13' -5ocs W14 X 8
106
0.125
3.5 371
1.9
0
203
S -GIs-1A--o shgc-0.75 0%S (2)
20
1.080
30.2 604
46.7
0
934
W -GIs-1A-' b-o shgc-0.75 5%S
6
1.080
30.2 181
131.5
0
789
UP-Ceil-16 -30 14 X 13
182
0.032
0.9 163
1.3
0
233
Floor-20P-3,� 13 X 14
182
0.035
1.0 178
0.4
0
64
Subtotals f r Structure:
1,791
0
2,384
Infil.: Win.: 1.7, Sum.: 4.3
216
1.380 298
0.324
177
70
Ductwork: !
740
602
People: 200; lat/per, 230 sen/per:
1
200
230
Equipment: I
_ 300
0
Room Total :
i
I
i
i
i
I
I
i
i
i
i
I
I
i
'I
i
i
I
I
2,829
677
3,286
C:\ ...\Rizk Re�Ijdence.rh9 Thursday, April 17, 2014, 8:58 AM
i
Rhvac - , esidential,&'L,ight Commercial HVAC Loads ...
Elite Software Development, Inca,
Residential Energy,Calc's
Rizk Residence
Port Saint (Lucie, FL 34983
Pane 18
Detail;', d Room -Loads - Room 11 - Laund
(Peak Fenestration Gain Procedure)
Genera{,
_, .. �. ,
�
71
i'
Room is zone 2, which peaks at 5 pm
Calculati Mode:
Htg. & clg.
Occurrences:
1
in
Room Le gth:
9.0
ft.
System Number:
1
Room Wi', the
6.0
ft.
Zone Number:
2
Area: 1
54.0
sq.ft.
Supply Air:
5 CFM
Ceiling H l ight:
8.0
ft.
Supply Air Changes:
0.7 AC/hr
Volume: 1
432.0
cu.ft.
Req. Vent. Clg:
0 CFM
Number o, Registers:
1
Actual Winter Vent.:
0 CFM
Runout A":
Runout Diict Size:
5
4
CFM
in.
Percent of Supply.:
3 %
Actual Summer Vent.:
0 CFM
Runout Ai' Velocity:
56
ft./min.
Percent of Supply:
2 %
Runout Ai', Velocity:
56
ft./min.
Actual Winter Infil.:
0 CFM
Actual Lo s:
0.004
in.wg./100 ft.
Actual Summer Infil.:
0 CFM
. 5n
Item . ,.
I
>, Area
` `
x Htg Sen
Clg l.at
°Se
Desc6011 on `�
Quanti,_ .. Values, HITM Loss
HTM Gam,
UP-Ceil-16 -30 9 X 6
54 0.032
0.9 48
,,Gain
1.3 0
69
Floor-20P- PP 6 X 9
54 0.035
1.0 53
0.4 0
19
Subtotals f Structure:
101
0
88
Infil.: Win.: 1.0, Sum.: 0.0
0
0 0
0 0
0
Ductwork:
36
20
EquipTent:l,
600
0
Room Total :
i
i
I
I
I
i
i
i
I
I
i
i
I
i
i
i
i
i
I
i
I
i
i
i
I
137
600
108
C:\ ...\Rizk Res�l encexh9 Thursday, April 17, 2014, 8:58 AM
Rhvac " Residential j&L Light Commercial HVAC Loads _
Elite Software Development; Inc..
Residential Energy Calc's
Rizk Residence
Port;Samt!Lucie, FL 34983 -..v
:'
Pa a 19
Detail d Room Loads-- Room 12 - Stairway (Peak Fenestration .Gain Procedure)
General
Room is I
zone 2, which peaks at 5 pm
Calculati
n Mode:
Htg. & clg.
Occurrences:
1
Room Le'
gth:
10.0 ft.
System Number:
1
Room Wi
the
7.0 ft.
Zone Number:
2
Area:
70.0 sq.ft.
Supply Air:
320
CFM
Ceiling H
fight:
8.0 ft.
Supply Air Changes:
34.3
AC/hr
Volume:
560.0 cu.ft.
Req. Vent. Clg:
0
CFM
Number o
Registers:
3
Actual Winter Vent.:
2
CFM
Runout Ai'-
107 CFM
Percent of Supply.:
1
%
Runout D
ct Size:
6 in.
Actual Summer Vent.:
5
CFM
Runout Ai
Velocity:
543 ft./min.
Percent of Supply:
2
%
Runout Ai',j
Velocity:
543 ft./min.
Actual Winter Infil.:
3
CFM
Actual Lo
1 :
0.189 in.wg./100 ft.
Actual Summer Infil.:
1
CFM
Item'.
Areaa U-
Htg Sen
Clg
Lat
Sen
Descrip it on;-
Quanti_, , Value
H"(M Loss .
HTM
Gain
Gain,
W -Wall-13'I -5ocs 7 X 8
15.5 0.125
3.5 54
1.9
0
30
W -GIs-1A- m-o shgc-0:75 1%S
40.5 1.270
35.6 1,440
137.8
0
5,581
UP-Ceil-16 ��-30 10 X 7
70 0.032
0.9 63
1.3
0
90
Floor-20P- ,X 10 _
_ 70 0.035
_ 1.0 69
0.4
0
25
Id
Subtotals fo Structure:.
1,626
0
5,726
Infil.: Win.: - .5, Sum.: 1.1
56
1.375 77
0.321
46
18
Ductwork: i
603
1,289
Room Total':
i
,I
it
i
i
I
I
i
i
I
i
i
i
i
i
_
2,306
46
7,033
C:1... \Rizk Residence.rh9 Thursday, April 17, 2014, 8:58 AM
II
Rhvac Rgsident1a14 Light Commercial HYAC Loads, _., .
Elite Software Development, Inc.
Residential Energy Ca Ids
1Port,LM. ,ucie, FL 34983 : ,�
-
.. .` ,-Rizk Residence
Page 20
S ateip 1 Room Load Summary
T.x Btuh� Btuh�
---Zone 1 !
--
1 Kit
320
6,396 83 5-6
460 9,929 866 452 452 "
,hen
2 Din1
ng 95
611 8 1-4
178 342 346 16 16
3
g 176
3,800 49 2-5
621 3,722 474 169 169
i �
4
rway 77
565 7 1-4
160 307 46 14 14
5 Fo 'fir
57
657 9 1-4
235 451 337 20 20
Zoe
1 subtotal 724
12,027 156
14,750 2,069 671 671
---Zone 2 it
_
6 Bat i
2 77
1,567 20 1-4
653 1,253 438 57 57
7 Ma
ter Bath 126
1,647 21 1-4
515 988 438 45 45
8 Ma
ter Bedroom 272
5,032 65 3-5
556 4,996 746 227 227 -
9 Wa
�C In Closet 42
477 6 1-4
124 238 46 11 11.
10 Be
oom 2 182
2,829 37 2-5
548 3,286 677 150 150
11 Lau'
II dry 54
137 2 1-4
56 108 600 5 5
12 Staitway
70
2,306 30 3-6
543 7,033 46 320 320-
&4
2 subtotal 823
13,994 182
17,901 2,991 814 814
Ven
ilation
769
412 1,038
Duce
Latent
1,460
_
Sys
4m 1 total 1,547
26,790 338
28,251 7,558 1,267 1,267
System 1
ain Trunk Size:
12x18 in.
Velocity:
II
844 ft./min
Loss per 1�
0 ft.:
0.100 in.wg
Note: Sin
a the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains
at the roo
and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended
to equal t
totals at the system level.
Room and zone sensible gains and cooling CFM values are for the hour in which
the glass
nsible gain for the zone is
at its peak. Sensible gains at the
system level are based on the "Average Load
Procedures+
Excursion" method.
Pooling S"
stern*mma :_:
s} Coolmg Sensible/Latent Sensible ! F �LatentN Total
'F ,YYxl J4J .f f JTi
y
Tons
8.�
J=Split
,z
...:Btuh
Net Requi
d: 2.98
79% / 21 %
28,251 7,558 35,809
Actual:
3.00
79% / 21 %
28,500 7,500 36,000
E ui° merit
r k x'E
Data l r:.. .
Heating System
Cooling System
Type:
Electric Resistance
Standard Air Conditioner
Model:
FV4CNF002
24ACB736A
Indoor Mo
el:
FVCNF002
Brand:
PERFORMANCE SERIES
PERFORMANCE SERIES
Descriptio
STRAIGHT COOL
STRAIGHT COOL 16 SEER
Efficiency:
0%
16 SEER
Sound:
0
0
Capacity:
36,000 Btuh
36,000 Btuh
Sensible C
pacity:
n/a
28,500 Btuh
Latent Cap'
city:
n/a
7,500 Btuh
AHRI Refe
, nce No.:
i
i
I
i
I
I
n/a
5630621
C:\ ...\Rizk RBI sidence.rh9 Thursday, April 17, 2014, 8:58 AM