Loading...
HomeMy WebLinkAbout1404-0377-KSM PILE INSTALLATION INSPECTION&0--- H661-6)3 aML_Jiva KELL R, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1 377 SEBASTIAN (772) 589-0712 PALM B CH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-90933 C.A.: 5693 FAX (772) 589-6469 j June 30, 2014 James Newman JWN Construction 1701 S.E. Carvalho Street Port St. Lucie, Florida 34983 Re: Pile Installation Inspection 1234 Nettle Boulevard Jensen Beach, Florida Permit #: 1404-0377 KSM Project #: 141149-pile Dear Mr. Newman: SCANNED By St, Lucie Cl lift, As requested, we were present during the installation of the twenty three (23) auger -cast -piles for the proposed structure at the referenced site. Pile layout by others. The pile installation inspection was generally performed in accordance to the "Inspector Guide to the Auger Cast -In -Place Piles", published by the Auger Cast -In -Place Pile Committee of The Deep Foundation Institute. Based on this inspection, it is our professional opinion, that the piles constructed for the referenced project were installed as specified on the construction drawings. The pile documentation and Location Plan are attached. to be of assistance to you on this phase of your project. If you ,ns, please feel free to call. 00 =•. No. 6836te, OF A1. E-mail to: jwnconstruction@comcast.net Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 KELL R, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 PO. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM B CH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5603 FAX (772) 589-6469 Pile Installation Inspection 1234 Nettle Boulevard Jensen Beach, Florida KSM Project #: 141149 Date Installed: June 27, 2014 Pile Location (See Location Plan) Pile Diameter Pile Depth Pump Strokes Truck No. Time Installed 1 14" 33' 44 22607 9:40 2 " " 48 119:52 3 50 of10:12 4 IT 49 25318 10:30 5 of54 1110:45 6 if42 If10:58 7 50 25318 & 26433 11:15 8 46 26433 11:32 9 47 11:45 10 45 12:02 11 52 22607 12:20 12 47 12:35 13 50 12:48 14 52 22607 & 23483 1:07 15 48 23483 1:19 16 49 If1:37 17 52 if1:50 18 46 25361 2:07 19 47 112:20 20 47 It2:39 21 45 25361 & 22607 2:57 22 44 22607 3:12 23 43 It3:25 1. Pile Reinforcing — 6 - #5 Vertical cont. with #4 Ties @ 12" o.c. 2. Pile Compressive Strength = 5,000 p.s.i. 3. 1 Pump Stroke = 1.07 cu. ft. grout Ronald G. Keller, P.E.: 37293 / SI Lie. No.: 860 / Julie E. Keller, P.E.: 68366 _I Z K P ESI Pf ffC E T LEGEND, - LOCATION OF 14" DIA. AUGER CAST -IN PLACE PILE. LOCATION PLAN