Loading...
HomeMy WebLinkAbout1404-0377-REVISION 9-5-14OFFICE US ONLY: OCQNNE DATE FILE �: / 7t/ v�� PERMIT # ��` D REVISION E: S�� RECEIPT # 3 i 1. PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 FAX (772) 462-1578 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1234 Nettles Blvd., Jensen Beach, Florida 34957 2. ]DETAILED DESCRIPTION OF PROJECT 3. 4. front patio to den of FL REG./CERT. #: CRc'a2 `— ST. LUCIE COUNTY CERT. #: :SS NAME•Construction, Inc. Fi RS NAME: James W. Newman SS: 1701 SE Carvalho Street Port St. Lucie (DAYTIME): 772-201-8947 2/BUILDER INFORMATION: STATE: FL ZIP: 34983 FAX: 772-871-9500 Louis and Gloria R1zk 633 Nettles Blvd. Jensen Beach STATE: FL ZIP: 34983 609-7095048 FAX: [ITECT/ENGINEER INFORMATION: E: Quantum Engineering Associates LESS•• •- 300 Avenue of Champions Palm Beach Gardens I STATE: FL [E (DAYTIME): 561-202-6994 07/22/2014 ZIP: 33418 FAX: 561-296-2494 FORM 405 10� I FLORI I A ENERGY EFFICIENCY 3 ?7 CODE FOR BUILDING CONSTRUCTION Florid Department of Business ad Professional Regulation - Residential Performance Method Project Name Rizk Residence Builder Name: Street: Lot 1234 Nettles Blvd. Permit Office: St. Lucie County City, State, Zi, : Ft. Pierce, FL, Permit Number. Owner. I Jurisdiction: Design Locatii n: FL, Fort Pierce 1. New constr tion or existing New (Flom Plans) 9. Wall Types (1928.0 sqft.) Insulation Area 2. Single famit or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1720.00 ft2 b. Frame - Wood, Exterior R=19.0 208.00 ft2 3. Number of its, if multiple family 1 c. NIA R= ft2 4. Number of drooms 2 d. N/A R= ft2 5. Is this a t case? No 10. Ceiling Types (823.0 sqft.) Insulation Area wo a. Under Attic (Vented) R=30.0 823.00 ft2 6. Conditioned area above grade (ft2) 1717 b. N/A R= ft2 (floor Cor c. R= ft2 Conditioned area below grade (ft2) 0 IIcts I 11. DuctR ft2 7. Windows(2 I .5 sqft.) Description Area a. Sup: RoomslnBlockl, Ret: RoomslnBlock1, AH: 6 164.E a. U-Facto Sgl, U=0.29 268.50 ft2 SHGC: b. U-Factor SHGC=0.30 Gbl, default 4.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: Clear, default a. Central Unit 42.0 SEER:16.00 c. U-Factor N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Facto N/A ft2 a. Electric Strip Heat 42.0 COPA.00 SHGC: Area Weigh ed Average Overhang Depth: 1.000 ft. Area Weighed Average SHGC: 0.304 14. Hot water systems 8. Floor Type (993.0 sqft.) Insulation Area a. Electric Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 993.00 ft2 EF: 0.990 b. Conservation features b. N/A R= ft2 None c. N/A . R= ft2 15. Credits CF, Pstat Glass/Floor rea: 0.159 Total Proposed Modified Loads: 27.34 PASS Total Standard Reference Loads: 38.76 I hereby cert,ly that the plans and ecifi Ions I ered by Review of the plans and Os�'S S�Ap� this calculate n are in compliance with the Flo da Energy specifications covered by this �+ _ - O ��' Code. I calculation indicates compliance I with the Florida Energy Code. PREPARE BY: 1Cs'DC/r7d%a_ Before construction is completed < 41I DATE: this building will be inspected for 0. compliance with Section 553.908 I hereby ce 'fy that .this buil g, as desig d, is in compliance Florida Statutes. COD with the Flor ida Energy C WE OWNER/AGENT: �"�� BUILDING OFFICIAL: DATE: DATE: Complia ce requires completion of a Florida Air Barrier and Insulation Inspection Checklist I 9/1/20141 40 PM EnergyGau e® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 1. New constru' 2. Single famil� 3. Number of 4. Number of 5. Is this a wor 6. Conditioned'I 7. Windows - a. U-Factor: SHGC: b. U-Factor' SHGC: c. u-ractor SHGC: d. U-Factor SHGC: Area Weigh Area Weigh 8. Floor Types a. Slab-On-1 b. N/A c. N/A ENERGY PERFORMANCE LEVEL EPL PISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 71 The lower the EnergyPerformance Index, the more efficient the home. Sion or existing or multiple family As, if multiple family case? )or area (ft2) Description Sgl, U=0.29 SHGC=0.30 Gbl, default Clear, default N/A N/A Average Overhang Depth: Average SHGC: Edge Insulation Lot 1234 Nettles Blvd., Ft. Pierce, FL, New (Fm Plans) Single-family 1 2 No 1717 Area 268.50 ft2 4.00 ft2 ft2 ft2 Insulation R=0.0 R= R= 1.000 ft. 0.304 Area 993.00 ft2 ft2 ft2 9. Wall Types Insulation Area a. Concrete Block - Int Insul, Exterior R=5.0 1720.00 ft2 b. Frame - Wood, Exterior R=19.0 208.00 ft2 c. N/A R= ft2 d. N/A R= ft2 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 823.00 ft2 b. N/A R= ft2 c. N/A R= ft2 11. Ducts R ft2 a. Sup: RoomslnBlockl, Ret: RoomslnBlockl, AH: 6 164.6 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction lhrough the above energy saving features which will be installed (or exceeded) in this home Before final insp ction. Otherwise, a new EPL Display Card will be completed based on ins lied Code c pliant feat es. Builder Sign ure: Date: �-3 -� E Address of N w Ho �j3 City/FL Zip: *Note: 638-1 inforn staff. **Label kBtu/hr Efficiency 42.0 SEER:16.00 kBtu/hr Efficiency 42.0 COP:1.00 Cap: 1 gallons EF: 0.91 CF. Pstat 'F k a C its is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient (EEM) incentives if you obtain Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For n about the Florida Building Cole, Energy Conservation, contact the Florida Building Commission's support ired by Section 303.1.3 of thg Florida Building Code, Energy Conservation, if not DEFAULT. USA - FlaRes2010 Section 405.4.1 Compliant Software PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Rizk Residence FLProp2010 1 St. Lucie County Single-family New (From Plans) Bedrooms: 2 Conditioned Area: 1717 I Total Stories: 2 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address Lot 1234 Nettles Blvd. St. Lucie Ft. Pierce , FL, CLIMATE V De pn Location TMY Site IECC Design Temp Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL! Fort Pierce FL_ST_LUCIE_CO I I WTL 2 39 90 70 75 722 62 Low 7- BLOCKS Number Name Area Volume 1 Blockl 1717 13736 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 RoomslnBlock1 1717 13736 Yes 2 2 1 Yes Yes Yes FLOORS # 11 Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 SI -On-Grade Edge Insulatio RoomslnBlockl 100 ft 0 993 ft2 ____ 0 0 1 ROOF V # Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Composition shingle 1076 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC VV # # I Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented, 300 993 ft2 N N CEILING # Ceiling Type (Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) RootnslnBlock1 30 823 ft2 0.11 Wood it i 9/1/2014 11:40 M EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 i WALLS Adjacent SpaceEt Cavity Width Height Sheathing Framing Solar Below Etn Area R--Valilelle ,or1 S Exterior Concrete Block - Int Ins8o, omSlnBloc 5 32 16 512 ft2 0 0.75 0 2 N Exterior Concrete Block - Int InsBloomslnBloc 5 20 16 320 ft2 0 0.75 0 3 W Exterior Concrete Block - Int InSBloomsinBloc 5 21 16 336 ft2 0 0.75 0 ft2 0 0.75 0 4 E 5 NW Exterior Exterior Concrete Block - Int Ins6foomSlnBloc Frame - Wood RoomslnBloc 5 29 19 15 16 8 464 120 ft2 0.23 0.75 0 6 SE Exterior Frame - Wood Rq1 omsinBloc 19 11 8 88 ft2 0.23 0.75 0 7 SE Exterior Concrete Block - Int Ins:omslnBloc i 5 11 8 88 ft2 0 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood RoomslnBloc None 0.460000 3 7 21 ft2 2 I NW Wood Roo�nslnBloc None 0.460000' 3 7 21 ft2 WINDOWS Orientation shown is the entered; Proposed orientation. Wall Overhang # mt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 .IS 1 Metal Single (Tinted) I Yes 0.29 0.3 N 40 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 2 S 1 Metal Single (Tinted) Yes 0.29 0.3 N 24 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 3 S 1 Metal Single (Tinted) Yes 0.29 0.3 N 54 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None. 4 N 2 Metal Single (Tinted) Yes 0.29 0.3 N 12 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 5 VV 3 Metal Single (Tinted) Yes 0.29 0.3 N 18 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 6 IN 3 Metal Single (Tinted) Yes 0.29 0.3 N 22.5 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 7 fV 3 Metal Single (Tinted) Yes 0.29 0.3 N 6 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 8 4 None Glazed Block No 0.6 0.6 N 4 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 9 4 Metal Single (Tinted) Yes 0.29 0.3 N 9 ft2 1 ft 0 in Oft 0 in HERS 2006 None 10 4 Metal Single (Tinted) Yes 0.29 0.3 N 6 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 11 S E 6 Metal Single (Tinted) Yes 0.29 0.3 N 42 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 12 E 7 Metal Single (Tinted) Yes 0.29 0.3 N 35 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 BySpaces Proposed SLA 0.00036d 1621.3 89.009 167.39 0.3235 7.0821 9/11201411:40 JPM EnergyGauge® PSA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP: 1 42 kBtu/hr 1 sys#1 I COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None i SEER: 16 42 kBtu/hr 1260 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garige 0.9108 1 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSE Collector Storage Cert Company Name System Model # Collector Model # Area Volume FEF Non �I None ftz DUCTS --- Supply ---- Return -- Air Percent HVAC # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool 1 RoomslnBloc 6 164.6 ft RoorrislnBloc 41.15 ft DSE=0.88 RoomslnBl 0.0 cfm 0.00 % 0.00 0.60 1 1 TEMPERATURES Programable TIC ermostat: Y Ceiling Fans: Cooling Ian [X Feb Mar X Apr May Jun X Jul [X Aug [X] Sep ] Oct Nov Dec Heating an [XFeb � Mar rx XApr [X] May Jun XJul [X� Au[X] Sep R1 JXX ] Oct [X1 Nov EX� Dec Ventin [x an [X Feb Mar [X Apr [X] May [X Jun [x] Jul [X Aug [X] Se Xj Oct [X Nov [X Dec Thermostat Sche ule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78' 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 '68 68 68 68 68 PM 68 68 68 68 68 68 68 166 68 68 66 66 Heating (WEH) AM 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/1/2014 11:40 ISM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 I FORM 405l+�, 0 Florida Florida Departm :ode Compliance Checklist it of Business and Professional Regulations Whole Building Performance Method I ADDRE4 Lot 1234 Nettles Blvd. I PERMIT #: I III Ft. Pierce, FL, MANDATORY REQUIREMENTS SU - See individual code sections for full details. COMPON I�T SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessled lighting IC -rated as meeting ASTM E 283. Windows and doors 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: asketed e doors & outdoor combustion air. Must complete envelope P P leakage' report or visually verify Table 402.4.2. Thermostats& 403.1 A least t o s� n thermostat shall be provided for each separate heating and one t ost p p g controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can. meet the load. Ducts 403.2.2 All duct, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing be ducts. cavities shall not used as supply Water heat rs 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 463.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 j+ accessible manual OFF switch. Mechanical 403.5 Homes (designed to operate at positive pressure or with mechanical ventilation systems shall not exceed the minimum ASHRAE 62 level. ventilati No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming 0 13ols 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and helIled pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/hea ing 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 603.2.3. Equipment efficiency verification required. Special equipmei t occasiori cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/kne i walls 405.2.1 R-19 sbace permitting. i i 9/1/201411:40 1 M EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software I Page 5 of 5 10 Rhvac Res cJent�al'8� Light Commercial HVAC Ldads Ehte'Software Development, Inc " tes�dentlal ergy Calc s „' Rizk Residence„' Port Sairit Lugie, FL` 34983 Rage . Pro ect�A a ort :.. General T Rizk Residence IdProject Designed: QEA Associates Project D Wednesday, April 16, 2014 Client Na • Rizk Client Addass: Lot 1234 Nettl as Blvd. Client City: Ft. Pierce, Flo ida Company ame: Residential Energy Calc's Diasn Da a`��rY �5 11,41 N .. ��. Reference' ity: Fort Pierce, Florida Building O'entation: Front door faces East Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Fa tor: 0.999 Outdoor Outdoo Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.1 n/a n/a 70 n/a Summer: 90 78 59% 50% 75 61 Total Build g Supply CFM: 1,466 CFM Per Square ft.: 0.854 Square ft. f Room Area: 1,717 Square ft. Per Ton: 505 Volume ( of Cond. Space: 13,736 Buildin ., ..... Total Heating Required Including Ventilation ir: 32,693 Btuh 32.693 MBH Total Sens le Gain: 32,625 Btuh 80 % Total Later t Gain: 8,173 Btuh 20 % Total Cooli g Required Including Ventilation Air: 40,798 Btuh 3.40 Tons (Based On Sensible + Latent) Rhvac is a j ACCA approved Manual J and Manual D computer program. Calculatior are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All comput d results are estimates as buildi g use and weather may vary. Be sure to elect a unit that meets both sensible and latent loads according to the manufacturer's performance data at desig conditions. \your C:\ ...\Rizk f esidence.rh9 Tuesday, September 02, 2014, 8:40 AM Rhvac - es,ldential , &119ht'Commercial HVAC Lgg4s Elite Software Development, Inc: i .. Riik Residence ; Port Samtt L cie�FLC34983 Page 3 Mscell"neous Report System 1 Rh_eem OrEquivalent TrfF `<Duttlogr Outdoor ° Outtloo fi Indoor jlndVON =a1 AGrains' �:'` U"'�.w $r'�3' "s fik'�w't�`b Rel�Hum InpADatar RelxHum;� ou_I.. DifFerence,: Winter: 1 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61.09 Duct Sizirig, In puts Main Trunk Runouts Calculate: Yes Yes Use Sche le: Yes Yes Roughnes Factor: 0.00300 0.01000 Pressure op: 0.1000 in.wg. `100 ft. 0.1000 in.wg./l00 ft. Minimum elocity: 650 ft./mi 450 ft./min Maximum elocity: 900 ft./mid 750 ft./min Minimum F Bight: 0 in. 0 in. Maximum II eight: 0 in. 0 in. Outside Air"Data Winter Summer Infiltration pecified: 0.380 AC/hr 0.200 AC/hr 87 CFM 46 CFM Infiltration ctual: 0.364 AC/hr 0.168 AC/hr Above Gra Je Volume: X 13,736 Cu.ft. X 13,736 Cu.ft. 5,090 Cu.ft./hr 2,302 Cu.ft./hr X 0.0167 X 0.0167 Total Build ng Infiltration: 83 CFM 38 CFM Total Build g Ventilation: 25 CFM 25 CFM ---Syste 1--- Infiltration Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infil ration Specified: 0.380 AC/h� (87 CFM), Construction: Average Summer I 11tiltration Specified: 0.200 AC/h (46 CFM), Construction: Average Duct Load; Factory Scenarios forXS.. stem � F 3 a h� rt' �,� µ � > ;tAtt►c �t a� ADuct � ��:, Duch Surfacek ` � x Prom: ?� i �� 7 U 'a t' f., "�? [)esenption;;-;F. f.4,. e, Insu�Iatori Area, TjMDD> a MLocation �, ,Ceilin!Leaka „O 1 Supply Attic 16B 0.12 6 397 No 1 Retu!n Attic i 16B 0.12 6 220 No III C:1... 1Rizk Iesidence.rh9 Tuesday, September 02, 2014, 8:40 AM Rhvac - Residential Aes,identiiil En66y,.Cal GQmff1,e,r,c1aI HVAU'Loaus" -i R1zk Resideri6 Port Sa nt L66ie, FL U983� Page Pa L Duct Sig`e Preview Room orSource niFnu ml im Maximum Rough. 'a, Design i Agn Duct Name Velocity Velocity y 0� Factor U100 L System 1 --------- - -- - 7 ...... . .. . .... - ----- supplyRun is --- ---- --- - -- .. . ..... ... ...... - --- -- ---- -- ---------- Zone 1 -­--M 1-Kitchen - ---- - - ---- Built-In 450; 750 0.01, - ---------- 0.1. 549.6, 432 4-6 2-Dining E Ln - n tiio -- -- - ------ ----7-5-0. 0.01 0.1 152.7 10� MI ____13___ ...... .. - --1-4 3-Living Built-in 450 750 0.01 0.1 590.- --- --- 61 161 2-5 4-S tairwa Built-In 1460 760 0.01. 0.1 139.1 10 12: 1-4 5-Foyer Built -In __1450______ 750. 0.01 0.1 - 215.2. - ----- 1 19' 1-4 Zone 2 6-Bath2 Built In 450 750, 0.01, 0.1 633.8; 19= 55 1-4 7-Master ath Built-in 450, 750 0.01 0.1, 500.2! - --- - ------ 20 44 1-4 ....... ... I . ..... ..... 8-Master E 9-Walk In - 1-1-1 ......... .... .... ...... edroorn 'Ioset . .. . .. .. ..................... . . . Built In 450, Breit In i 450 750; 750 0.01 0.1 . .... ..... 0.01: 0.1 538.6 120.61 62; 6 220 11: 3-5 1-4 10 -BedrDd n 2 ----- ------ ----- -- Built -In -------------- 450 0.01 0.1 531.7: 35 145- 2-5 1 1-Laund Built in 450 -750y 750 0.01 0.1 54.4 ---------- 5 1-4 12-Stairw Built-in 450T.; 750, 0.01 0.1 526.3, 2M 310; 3-6 13-Den j 'Built -In 450 750 0.01 0.1 529.9 53,= 312, 34 Other Ducts In System I Supply ME - ------- - --- In Trunk - ----- Built-in 650' 900 0.0031 0.1 886.7' 1,466 11417 Summary System 1 --- -- ----- Heating FkAv: 415 Cooling F1 liw 1466 C:\ ... \Rizk Plesidence.rh9 I Tuesday, September 02, 2014, 8:40 AM Rhvac - Residential &Light Commercial HVAC Loads Elite Software_ Development, Inc. . ,Residenttai Energy dales.' ; 1, Rizk Residence PortSaint,l-ucie, FL 34983 Pa a 6; ilding Sumrna Loads Area Sen Lat Sen "total_ H1A--cb-o: ` .IN �.. Quan loss . Gain.. Gain Gaim zing -Single pane, operable windowclear, 200.8 6,069 0 8,122 8,122 , me with break,"u-value 1.08, SHGC 0.75-Single pane, operable window, clear, 117.5 4,179 0 8,606 8,606 metal fri me no break, u-value 1.27, SHGC 0.75 7A-1: Glazi �g-Glass or plastic block, smooth or wide ribs 4 68 0 286 286 or flute no screen, no coating, u-value C.6, SHGC 0.65 10A-m: Gla ing-French door, single pane clear glass, 24 1,122 0 1,470 1,470 metal fr me no break, u-value 1.67, SHGb 0.53 11 D: Door- ood - Solid Core j 42 352 0 336 336 13A-5ocs: all -Block, board insulation only, R-5 board 1306.3 4,574 0 2,501 2,501 insulatid n, open core, siding finish 12E-Osw: P rt-Frame, R-19 insulation in 2 x q stud cavity, 91 93 0 93 93 no boa I'J insulation, siding finish, wood stp ds 12E-Osw: V i all -Frame, R-19 insulation in 2 x 6 stud 88 168 0 104 104 cavity, o board insulation, siding finish, good studs 16C-30: Ro f/Ceiling-Under Attic with Insulation on Attic 1717 1,539 0 2,200 2,200 Floor ( so use for Knee Walls and Partition Ceiling , Vented Attic, No Radiant Barrier, White or Light C' for Shingles, Any Wood Shake, Light Metal, Tar an Gravel or Membrane, R-30 insulation 22A-ph: Flo' r-Slab on grade, No edge insulation, no 88 3,346 0 0 0 insulati n below floor, any floor cover, passive, heavy moist s 6 it 20P-30: Floor -Over open crawl space or garage, Passive, 993 973 0 349 349 R-30 bl nket insulation, any cover Subtotals f r structure: 22,483 0 24,067 24,067 People: 4 800 920 1,720 Equipment 3,300 600 3,900 Lighting: 0 0 0 Ductwork: 6,875 1,440 5,993 7,433 Infiltration:' inter CFM: 83, Summer CFM: �8 2,566 1,595 633 2,228 Ventilation Winter CFM: 26, Summer CFM: 25 769 1,038 412 1,450 Total Build g Load Totals: 32,693 8,173 32,625 40,798 Total Build g Supply CFM: 1,466 CFM Per Square ft.: 0.854 Square ft. f Room Area: 1,717 Square ft. Per Ton: 505 Volume ( of Cond. Space: 13,736 BtuildinLoatl`s Total Heatihg Required Including Ventilation Air: 32,693 Btuh 32.693 MBH Total Sen9ble Gain: 32,625 Btuh 80 % Total Lateit Gain: 8,173 Btuh 20 % Total Cooli g Required Including VentilationAir: 40,798 Btuh 3.40 Tons (Based On Sensible + Latent) Notes,. _ . ° ,, . • i ACCA approved Manual J and Manual D computer program. 11 Rhvac is a Calcu atior s are performed per ACCA Manusl J 8th Edition, Version 2, and ACCA Manual D. All co put d results are estimates as buildi g use and weather may vary. Be sure to elect a unit that meets both sen ible and latent loads according to the manufacturer's performance data at your desig6 conditions. I C:\ ...\Rizk esidence.rh9 Tuesday, September 02, 2014, 8:40 AM Rhvac Residential S Light Commercial i"C Loads Ehte=Software Development, lne. Ftesidenbal Energy Calc's t Riik'Residence ,,Port Saint' Lucie, FL "34983 "1 _ pa" e 8 DetaiieN,I' Room Loads - Room '1- Kitchen (Peak Fenestration Gain Procedure) General Room is in I one 1, which peaks at 2 pm Calculatio Mode: Htg. & clg, Occurrences: 1 Room Len the 20.0 ft. System Number: 1 Room Wid 16.0 ft. Zone Number: 1 Area: :ht: 320.0 sq.ft. Supply Air: 432 CFM Ceiling He 8.0 ft. Supply Air Changes: 10.1 AC/hr Volume: 2,560.0 cu.ft. Req. Vent. Clg: 0 CFM Number of egisters: 4 Actual Winter Vent.: 6 CFM Runout Ai 108 CFM Percent of Supply.: 1 % Runout Du t Size: 6 in. Actual Summer Vent.: 6 CFM Runout Air' elocity: 556 ft./min. Percent of Supply: 1 % Runout Ai elocity: 550 ft./min. Actual Winter Infil.: 14 CFM Actual Los : 0,193 in.wg./100 ft. Actual Summer Infil.: 7 CFM Item {` Area =1i1- Wtg Sen Clg I_at Sen ®escriptio;, Quantity \/alue HTM Loss HTM Gain Gain E -Wall-1 3 ''-5ocs 18 X 8 131 0.125 3.5 459 1.9 0 251 SE-Wall-1 3 -5ocs 11 X 8 53 0.125 3.5 186 1.9 0 101 S -Wall-I3 -5ocs 11.5 X 8 50 0.125 3.5 175 1.9 0 96 E -GIs-1A -o shgc-0.75 0%S 9 1.080 30.2 272 76.7 0 690 SE-GIs-1A ' m-o shgc-0.75 0%S 35 1.270 35.6 1,245 80.2 0 2,806 E -GIs-7A- shgc-0.65 0%S (2) 4 0.600 16.8 68 61.5 0 246 S -GIs-1A- -o shgc-0.75 0%S (2) 24 1.080 30.2 726 64.1 0 1,538 S -GIs-1A- -o shgc-0.75 0%S 18 1.080 30.2 544 64.1 0 1,153 UP-Ceil-16 1 -30 20 X 16 320 0.032 0.9 287 1.3 0 410 Floor-22A- h 41 ft..Per. 41 1.358 38.0 1,559 -----""-------- 0.0 0 ------ 0 - - -- - -- - -- Subtotals for - -- ---- -- Structure: - -- --------- 5,521 0 7,291 Infil.: Win.: 1 4.4, Sum.: 6.6 324 1.367 443 0.336 275 109 Ductwork: 1,637 1,488 Equipment:', 600 ' 600 Room Tota s : 7,601 875 9,488 C:\ ...\Rizk esidence.rh9 Tuesday, September 02, 2014, 8:40 AM Rheae R9 � entia1`& Light Commercial HVACIdads; Ehte.Software Development, nc:• Residential Erie„FL 9Y Galc s " _' ;v Rizk Residence Pa 9 Port.Saint,Luner 34983 �: ,.; . .:, e Detaiie' Room ;LoadS -Room 2 - Dining (Peak Fenestration Gain Procedure) _ f��§ ;.�. _� ,..., Room is in'' one 1, which peaks at 2 pm Calculation Mode: Htg. & clg Occurrences: 1 Room Len the 13.� ft. System Number: 1 Room Wid 7. ft. Zone Number: 1 Area: '94.5 sq.ft. Supply Air: 13 CFM Ceiling Hei ht: 8.6 ft. Supply Air Changes: 1.1 AC/hr Volume: 756.5 cu.ft. Req. Vent. Clg: 0 CFM Number of egisters: 1 Actual Winter Vent.: 1 CFM Runout Air 1 13 CFM Percent of Supply.: 5 % Runout Du i t Size: in. Actual Summer Vent.: 0 CFM Runout Air elocity: 151 ft./min. Percent of Supply: 1 % Runout Air � elocity: 153 ft./min. Actual Winter Infil.: 2 CFM Actual Los' : 0.028 in.wg./100 ft. Actual Summer Infil.: 1 CFM Vlt mom;NJ Area yU .. Htg SenW -C Lta`t` Send Descri tlo., Quantit 3 Vial_ a 56 0.125 ,. _HTM LossTM 3.5 196 1.9 Gain 0 Gain 107 S -Wall-13.A, 5ocs 7 X 8 UP-Ceil-16 '. -30 13.5 X 7 �4.5 0.032 0.9 85 1.3 0 121 Floor-22A- 7 ft..Per. 7 1.358 38.0 266 0.0 0 0 Subtotals fc Structure:' 547 0 228 Infil.: Win.: 1.5, Sum.: 1.1 56 1.375 77 0.339 48 19 Ductwork: 171 46 Equipment: 300 0 Room Total : I 795 348 293 C:\ ...\Rizk f esidence.rh9 Tuesday, September 02, 2014, 8:40 AM Rhvac Resllential &,Light.Commerc�al HVAC Lo4 ds', Ehte Software Development.lnc. R�zk Residence Residential Energy � I Pa a,10 Port Saint�L`ucie, FL 94983 Detaile" Room Loads - Room 13,- Livin `(Peak Fenestration Gain Procedure) General l'._ one 1, which peaks at 2 pm I Room is in Calculatio Mode: Htg. & clg� Occurrences: 1 Room Len the 13.5 ft. System Number: 1 Room Wid 13.0 ft. Zone Number: 1 Area: 175.E sq.ft. Supply Air: 161 CFM Ceiling Heil ht: 8.6 ft. Supply Air Changes: 6.9 AC/hr Volume: 1,404.0 cu.ft. Req. Vent. Clg: 0 CFM Number of egisters: 2 Actual Winter Vent.: 4 CFM Runout Air 80 CFM Percent of Supply.: 2 % Runout Du t Size: 6 in. Actual Summer Vent.: 2 CFM Runout Air:' elocity: 590 ft./min. Percent of Supply: 1 % Runout Ai j lelocity: 590 ft./min. Actual Winter Infil,: 9 CFM Actual Loss: 0.286 in.wg./l00 ft. Actual Summer Infil.: 4 CFM m "' � Area -U- Htg Sen gLatjjj ffi7en'escriptioi DER'- -5ocs 13 X 8 Quantit 50 Value 0.125 HTM Loss 3.5 175 HTM 1.9 Gain . 0 96 S -Wall-13 W -Wall-13 -5ocs 13.5 X 8 108 0.125 3.5 378 1.9 0 207 S -GIs-lA-4 -o shgc-0.75 94%S (3) 54 1.080 30.2 1,632 44.1 0 2,382 UP-Ceil-16 -30 13.5 X 13 1 5.5 0.032 0.9 157 1.3 0 225 Floor-22A-F h 27 ft.. Per. 27 1.358 38.0 1,027 0.0 0 0 Subtotals f r Structure: 3,369 0 2,910 Infil.: Win.: A Sum.: 4.3 212 1.368 290 0.340 180 72 Ductwork: 1,004 555 Equipment _ _ 300 0 Room Tota s: 4,663 480 3,537 i CA ...\Rizk Residence.rh9 Tuesday, September 02, 2014, 8:40 AM Rhvac -Res ential &Light C_ommercial.HVAC LoSads El1w oftware Development, Inc: Rizk Residence Residential Energy Calc's . „ i , Page 11, :PortSam>`Luie FL 34983. (` =bet6fle',Room Loads -Room 4.- Stairwa (Peak Fenestration Gain Procedure) . ` Room is in one 1, which peaks at 2 pm Calculatio Mode: Htg. & c1gi. Occurrences: 1 Room Len the 11.0 ft. System Number: 1 Room Wid : 7.0 ft. Zone Number: 1 Area: 77.0 sq.ft. Supply Air: 12 CFM Ceiling He ht: 8.6 ft. Supply Air Changes: 1.2 AC/hr Volume: 616.6 cu.ft. Req. Vent. Clg: 0 CFM Number of Runout Air Registers: 1 1 CFM Actual Winter Vent.: Percent of Supply.: 1 5 CFM % Runout Dt pt Size: 4 in. Actual Summer Vent.: 0 CFM Runout Ai Velocity: 11 ft./min. Percent of Supply: 1 % Runout Ai 'Velocity: 130 ft./min. Actual Winter Infil.: 2 CFM Actual Los : 0.023 in.wg./100 ft. Actual Summer Infil.: 1 CFM Item Area -U- Htg Sen Clg Lat Sen Description -5ocs 7 X 8 Qpanfii 56 Value 0.125 HTM Loss 3.5 196 HTM Gain 1.9 0 Gain 107 W -Wall-13' UP-Ceil-16 -30 11 X 7 77 0.032 0.9 69 1.3 0 99 Floor-22A- h 7 ft..Per. 7 1.358 38.0 266 0.0 0 0 Subtotals f r Structure: 531 0 206 Infil.: Win.: 2.5, Sum.: 1.1 56 1.375 77 0.339 48 19 Ductwork: ! 167 42 Room Tot s: 775 48 267 C:\ ...\Riz Residence.rh9 Tuesday, September 02, 2014, 8:40 AM i Rhvac Residential $ Light Commercial HVAC Loads Ehte':Software Development, Inc.- Resio A141 E iergy Calcs i = Rizk Risidence= Port Saint Lu ie, Ft. '34983. C Pa..e �w Detaile' Room Loads - Room 4 - Stairwa`, (Peak Fenestration Gain Procedure General '' Room is in one 1, which peaks at 2 pm Calculatio Mode: Htg. & clg. Occurrences:. 1 Room Len the 11.6 ft. System Number: 1 Room Wid 7.6 ft. Zone Number: 1 Area: 77.9 sq.ft. Supply Air: 12 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.2 AC/hr Volume: 616.6 cu.ft. Req. Vent. Clg: 0 CFM Number ofRegisters: Actual Winter Vent.: 1 CFM Runout Air 12 CFM Percent of Supply.: 5 % Runout Du t Size: 4 in. Actual Summer Vent.: 0 CFM Runout Airy elocity: 139 ft./min. Percent of Supply: 1 % Runout Air i elocity: 139 ft./min. Actual Winter Infil.: 2 CFM Actual Los : 0.02� in.wg./100 ft. Actual Summer Infil.: 1 CFM Item i Area -U- Htg Sen Clg Lat Sen Descri tion Quantity Value HTM Loss HTM Gain Gain W -Wall-13 f -5ocs 7 X 8 56 0.125 3.5 196 1.9 0 107 UP-Ceil-16 1 -30 11 X 7 77 0.032 0.9 69 1.3 0 99 Floor-22A- 7 ft..Per. 7 1.358 38.0 266 0.0 0 0. Subtotals fc it Structure: 531 0 206 Infil.: Win.: .5, Sum.: 1.1 56 1.375 77 0.339 48 19 Ductwork: 1 167 42 Room Tota : I 775 48 267 C:\ ...\Rizk �residence.rh9 Tuesday, September 02, 2014, 8:52 AM Rhvac Residential &Light Commercial HVAC Loads Ehte Software Development, Inc. Residential Energy Calc's Rizk Residence ,= , Port Saint Lu le, FL 34983 1. Detaile - Room loads.- Room $ - Foyer (Peak Fenestration Gain Procedure) General �; �n Room is in one 1, which peaks at 2 pm Calculatio Mode: Htg. & clgl Occurrences: 1 Room Len'' 10.9 ft. System Number: 1 Room Wid 5.7 ft. Zone Number: 1 Area: 57.0 sq.ft. Supply Air: 19 CFM Ceiling Heil ht: 8.0 ft. Supply Air Changes: 2.5 AC/hr Volume: 456.0 cu.ft. Req. Vent. Clg: 0 CFM Number of egisters: 1 Actual Winter Vent.: 1 CFM Runout Ai 19 CFM Percent of Supply.: 3 % Runout D Size: 4 in. Actual Summer Vent.: 0 CFM Runout Ai (Velocity: 215 ft./min. Percent of Supply: 1 % .. Runout Ai Velocity: 216 ft./min. Actual Winter Infil.: 2 CFM Actual Lo 0.054 in.wg./l00 ft. Actual Summer Infil.: 1 CFM Item Area -lJ- Htg Sen C*Ig Lat Sen ©escriptio WE uanti IMPEL alue HTM Loss HTM Gain Gain E -Wall-1 3 -50cs 5.7 X 8 24.6 0.125 3.5 86 1.9 0 47 E-Door-11 P 3 X 7 21 0.390 10.9 229 10.1 0 213 UP-Ceil-16 -30 10 X 5.7 57 0.032 0.9 51 1.3 0 73 Floor-22A- h 6 ft..Per. 6 1.358 38.0 228 0.0 0 0 Subtotals f��------------------.._...-----------------_------ r Structure: --..._..-----------------._...----------------.—..___..__._...---------------------------------------- 594 0 333 Infil.: Win.: .0, Sum.: 0.9 46 1.360 62 0.329 39 15 Ductwork: 180 65 Equi ment 300 0 Room Tot I I s: 836 339 413 C:\ ...\R11 Residence.rh9 Tuesday, September 02, 2014, 8:52 AM Rh4ac - Residential 8<?LightCoinmercial HVAC Loads 'Elite Software Development, Inc.' Residential Port. Saint Lu''ie, 6` ergy Calc's FL 34983 '. ! eRizk Residence Pa a 13 Detailill Room Loads - Room 6 - Bath2 (Peak Fenestration Gain Procedure) Room is in one 2, which peaks at 5 pm Calculatio Mode: Htg. & c1d. Occurrences: 1 Room Len the 11.6 ft. System Number: 1 Room Wid h: 7.6 ft. Zone Number: 2 Area: 77.0 sq.ft. Supply Air: 55 CFM Ceiling He ht: 8.6 ft. Supply Air Changes: 5.4 AC/hr Volume: 616.0 cu.ft. Req. Vent. Clg: 0 CFM l Number 0, Registers: 11 Actual Winter Vent.: 1 CFM Runout Air 55 CFM Percent of Supply.: 2 % Runout Dt t Size: 4 in. Actual Summer Vent.: 1 CFM Runout Al Velocity: 634 ft./min. Percent of Supply: 1 % Runout Ai Velocity: 634 ft./min. Actual Winter Ill 7 CFM Actual Lo 0.45�1 in.wg./100 ft. Actual Summer Ill 3 CFM ItemSen ♦:, Clg Lat Seri ®escn do Quanti � Ualue HTM Loss HTM Gain Gain N -Wall-13 -5ocs 7 X 8 2.2 0.125 3.5 148 1.9 0 81 SW-Part-1 °/15°-12E-Osw 14 X 8 91 0.068 1.0 93 1.0 0 93 SW -Door- 1 D 3 X 7 21 0.390 5.9 123 5.9 0 123 N -GIs-IA- b-o shgc-0.75 7%S 13.8 1.080 30.2 417 39.5 0 545 UP-Ceil-1 -30 11 X 7 77 0.032 0.9 69 1.3 0 99 Floor-20P- 10 7 X 11 77 0.035 1.0 75 0.4 0 27 Subtotals 11 r Structure: 925 0 968 Infil.: Win.:j7.5, Sum.: 3.4 168 1.369 230 0.339 143 57 Ductwork: 317 191 Equipmen ------------- — ----- ------------ -- --- 300-----0. Room To I I I Is: 1,472 443 1,216 C:\ ...\Riz Residence.rh9 Tuesday, September 02, 2014, 8:52 AM Rhvac Residentia14light Commercial HVAC Loads Elitesoftware Develop nent,I= Residence �tesidentRal E�ergy,Catc's Port`SamtU"He, FL 34983: i Rizk . Pa a 14 -Detaile Rooin Loads- Room 7 - Master Bath (Peak Fenestration Gain Procedure) ,General Room is in one 2, which peaks at 5 pm Calculation (Mode: Htg. & clg� Occurrences: 1 Room LenIth: 14.9 ft. System Number: 1 Room Wid 9.0 ft. Zone Number: 2 Area: 126.6 sq.ft. Supply Air: 44 CFM Ceiling Hei ht: 8.0 ft. Supply Air Changes: 2.6 AC/hr Volume: j 1,008.9 cu.ft. Req. Vent. Clg: 0 CFM Number of egisters: Actual Winter Vent.: 1 CFM Runout Air 4 CFM Percent of Supply.: 3 % Runout Du t Size: i in. Actual Summer Vent.: 1 CFM Runout Ai Velocity: 500 ft./min. Percent of Supply: 1 % Runout Ai Velocity: 500 ft./min. Actual Winter Infil.: 7 CFM Actual Los' : 0.283 in.wg./100 ft. Actual Summer Infil.: 3 CFM Item Area -W- Htg Sen Clg LatWSen ©scri do _ Quantit Value HTM Loss HTM GainGain N-Wall-13 1-5ocs 6 X 8 42 0.125 3.5 147 1.9 0 80 E -Wall-13 I -5ocs 15 X 8 120 0.125 3.5 420 1.9 0 230 N -GIs-1A-, b-o shgc-0.75 15%S 6 1.080 30.2 181 39.5 0 237 UP-Ceil-16 -30 14 X 9 126 0.032 0.9 113 1.3 0 161 Floor-20P- 0 9 X 14 126 0.035 1.0 123 0.4 0 44 Subtotals f 1 r Structure: 984 0 752 Infil.: Win.: 17.5, Sum.: 3.4 . 168 1.369 230 0.339 143 57 Ductwork: 333 150 Equipment 300 0 Room Tot s: I 1,547 443 959 I I j C:\ ... \Rizl1 Residence.rh9 Tuesday, September 02, 2014, 8:40 AM Ahvac - Residential,,&; Ught`CommercIal HVA_C Loads 9lite Pgftware Development, Inc.' Residential EAe-r y:Calc's .. i �� Rizk Residence Port�Saint Lu' ie, FL 34983 - N e 15 Detaile'; Room Loads = Room B -Master Bedroom (Peak Fenestration Gain Pr. oced ',' re) General , Room is in ione 2; which peaks at 5 pm Calculatio Mode: Htg. & cigl Occurrences: 1 Room Len the 17.6 ft. System Number: 1 Room Wid 16.6 ft. Zone Number: 2 Area: 272.6 sq.ft. Supply Air: 220 CFM Ceiling Hei ht: '8.6 ft. Supply Air Changes: 6.1 AC/hr Volume: 2;176.0 cu.ft. Req. Vent. Clg: 0 CFM Number of egisters: 3 Actual Winter Vent.: 4 CFM Runout Ai 7� CFM Percent of Supply.: 2 % Runout Du t Size: 5 in. Actual Summer Vent.: 3 CFM Runout Ai Velocity: 539 ft./min. Percent of Supply: 1 % Runout Ai Velocity: 536 ft./min. Actual Winter Infil.: 13 CFM Actual Los : 0.239 in.wg./l00 ft. Actual Summer Infil.: 6 CFM Item Area -lJ- Htg Sen Clg Lat n ®escri tone„ Quantit Value HTM Loss HTM Gain _Se Gain NE-Wall-1 -5ocs 14 X 8 70 0.125 3.5 245 1.9 0 134 S -Wall-13 -5ocs 12.5 X 8 80 0.125 3.5 280 1.9 0 153 SE-Wall-1 i-Osw 11 X 8 88 0.068 1.9 168 1.2 0 104 NE-GIs-1A'6m-o shgc-0.75 0%S 42 1.270 35.6 1,494 47.2 0 1,984 S -GIs-lA- l'b-o shgc-0.75 0%S (2) 20 1.080 30.2 604 46.7 0 934 UP-Ceil-16�� -30 17 X 16 272 0.032 0.9 244 1.3 0 348 Floor-20P- 0 16 X 17 272 0.035 1.0 267 0.4 0 95 Subtotals f r Structure: 3,302 0 3,752 Infil.: Win.A3.3, Sum.: 6.1 300 1.370 411 0.337 255 101 Ductwork: 1 1, 1,019 759, People: 20 lat/per, 230 sen/per: 1 200 230 Equipment; 300 0' Room Tot li I i s: 4,732 755 4,842 C:\ ...\Ril Residence.rh9 Tuesday, September 02, 2014, 8:40 AM Rhvac Residential:& Light Commercial HVAC Loads: Ehtek5oftware Development,' Ine." Residential Erergy,Calc's `"" i ! Rizk Residence;. Pa Port"S'amE Lucie, FL ,34983 �I► � Room Loads - Room ' Walk In Closet (Peak Fenestration Gain .Detaile Proced �, re) General Room is in zone 2, which peaks at 5 pm Calculation' Mode: Htg. & c1g, Occurrences: 1 Room Len the 7.Q ft. System Number: 1 Room Wid 6. ft. Zone Number: 2 Area: 42.6 sq.ft. Supply Air: 11 CFM Ceiling Hei ht: 8.6 ft. Supply Air Changes: 1.9 AC/hr Volume: 336.6 cu.ft. Req. Vent. Clg: 0 CFM Number of��Registers: 1 Actual Winter Vent.: 0 CFM Runout Air 11 CFM Percent of Supply.: 3 % Runout Dul t Size: 4 in. Actual Summer Vent.: 0 CFM Runout Ai Velocity: 121 ft./min. Percent of Supply: 1 % Runout Ai Velocity: 121 ft./min. Actual Winter Infil.: 2 CFM Actual Los' : 0.01P in.wg./100 ft. Actual Summer Infil.: 1 CFM Item Area -U- Htg Sen Clg Lat Sen ®escriptio Quanti alue HTM Loss HTM Gain Gain S -Wall-13 -5ocs 7 X 8 56 0.125 3.5 196 1.9 0 107 UP-Ceil-16 1 -30 7 X 6 42 0.032 0.9 38 1.3 0 54 Floor-20P- 0 6 X 7 42 0.035 1.0 41 0.4 0 15 Subtotals f r structure: 275 0 176 Infil.: Win.: .5, Sum.: 1.1 56 1.375 77 0.339 48 19 Ductwork: 97 36 Room Tot I I I I s: 449 48 231 Q\ ...\Riz li Residence.rh9 Tuesday, September 02, 2014, 8:40 AM Rhvac,. Residential & Light Commercial HVAC Loads Elite -Software Development, Inc. Residential E{�ergy Calc's �; Rik Reside_ nce' .' Fort"Saint•Lu:'ie, FL 34983. .• 1 "Paw 17 DetaileO Room Loads - Room 10 -"Bedroom 2 (Peak Fenestration Gain Procedure) xGeneral�� '�3'L . Room is in one 2, which peaks at 5 pm CalculationiMode: Htg. &clgl Occurrences: 1 Room Len the 14.0 ft. System Number: 1 Room Wid 13.0 ft. Zone Number: 2 Area: j 182.9 sq.ft. Supply Air:, 145 CFM Ceiling Hei ht: 8.0 ft. Supply Air Changes: 6.0 AC/hr Volume: 1,456.6 cu.ft. 'Req. Vent. Clg: 0 CFM Number of egisters: 2 Actual Winter Vent.: 2 CFM Runout Air 7? CFM Percent of Supply.: 1 % Runout Du t Size: 5 in. Actual Summer Vent.: 2 CFM Runout Ai elocity: 532 ft./min. Percent of Supply: 1 % Runout Ai Velocity: 532 ft./min. Actual Winter Infil.: 10 CFM Actual Los : 0.233 in.wg./100 ft. Actual Summer Infil.: 4 CFM Item Area n Cti VaI_0M;-eHtg Loss HTM Gain G__ ain S -Wall-13 -5ocs 13 X 8 84 0.125 3.5 294 1.9 0 161 W -Wall-13 5ocs 14 X 8 106 0.125 3.5 371 1.9 0 203 S -GIs-1A- ib-o shgc-0.75 O%S (2) 20 1.080 30.2 604 46.7 0 934 W -GIs-1A b-o shgc-0.75 5%S 6 1.080 30.2 181 131.5 0 789 UP-Ceil-16 -30 14 X 13 182 0.032 0.9 163 1.3 0 233 Floor-20P- 0 13 X 14 182 0.035 1.0 178 0.4 0 64 Subtotals f r Structure: 1,791 0 2,384 Infil.: Win.: .6, Sum.: 4.4 216 1.370 296 0.338 184 73 Ductwork: 573 500 People: 20 lat/per, 230 sen/per: 1 200 230 Equipment) 300 0 Room Tot I I I I s: i 2,660 • 684 3,187 C:\ ...\Riz{ Residence.rh9 I Tuesday, September 02, 2014, 8:40 AM Rhvac Resiential,8'Ught Commercial HVAC Loads �iesident�al EI�"ergy Calc's El�teSoftware Development; Rizk Resid"ence Port Saint Lucie, FL 34983`', i ., , Pa 'e 18f Detaile .. Room Loads- Room 11- Laund (Peak Fenestration Gain Procedure)". General Room is in one 2, which peaks at 5 pm Calculations Mode: Htg. & clgL Occurrences: 1 Room Len the 9.6 ft. System Number: 1 Room Wid 6.6 ft. Zone Number: 2 Area: 54.6 sq.ft. Supply Air: 5 CFM Ceiling Heil ht: 8.6 ft. Supply Air Changes: 0.7 AC/hr Volume: 432.0 cu.ft. Req. Vent. Clg: 0 CFM Number of egisters:1 Actual Winter Vent.: 0 CFM Runout Ai 1 5 CFM Percent of Supply.: 2 % Runout D t Size: 4 in. Actual Summer Vent.: 0 CFM Runout Ai Velocity: 54 ft./min. Percent of Supply: 1 % Runout Ai Velocity: 5j ft./min. Actual Winter Infil.: 0 CFM Actual Los : 0.00 in.wg./l00 ft. Actual Summer Infil.: 0 CFM Item Area -@J- Htg Sen Clg Lat Sen Descri • do � Quanti alus HTM Loss HTM Gain Gain UP-Ceil-16 , -30 9 X 6 54 0.032 0.9 48 1.3 0 69 Floor-20P- 0 6 X 9 54 0.035 1.0 53 0.4 0 19 Subtotals f r Structure: 101 0 88 Infil.: Win.: 0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 28 16 Equipment 600 0 Room Tot I I I I I s: I � 129 600 104 C:\ ...\Riz Residence.rh9 Tuesday, September 02, 2014, 8:40 AM Rhvac Residential & Light Commercial HVAC Loads Residential"Energy Cal c's Elite Software Development, Inc: Rizk Residence FortiSaint.t i ie, FL 34983. �� page 19: Detaile' I'Room Loads - Room'12 - Stairway (Peak Fenestration -Gain Procedure) -. I,General Room is injzone Room 2, which peaks at 5 pm Calculatio"Mode: Htg. & clgg. Occurrences: 1 Room Len" the 10.b ft. System Number: 1 Room Wi h: 7.0 ft. Zone Number: 2 Area: 70.0 sq.ft. Supply Air: 310 CFM Ceiling He 9 ght: 8.0 ft. Supply Air Changes: 33.2 AC/hr Volume: . Number Registers: 560.�0 CU.ft. 13 Req. Vent. Clg: Actual Winter Vent.: 0 CFM 2 CFM o Runout Ai : 103 CFM Percent of Supply.: 1 % Runout D Ict Size: 6 in. Actual Summer Vent.: 4 CFM Runout Ail Velocity: 5 6 ft./min. Percent of Supply: 1 % Runout Ail Velocity: 516 ft./min. Actual Winter Infil.: 2 CFM Actual Lo is: 0.177 in.wg./100 ft. Actual Summer Infil.: 1 CFM item Area -U- Htg Sen Clg Lat Sen ®ascription Quantity Value HTM Loss HTM Gain Gain W-Wall-1 A-5ocs 7 X 8 15.5 0.125 3.5 54 1.9 0 30 W -GIs-1 lcm-o shgc-0.75 1%S 40.5 1.270 35.6 1,440 137.8 0 5,581 UP-Cei �C-30 10 X 7 70 0.032 0.9 63 1.3 0 90 Floor-20P 0 7-X 10 -- ------ -- ------- 70 -- — 0.035 1.0 69 --- ------ - - - - — — -- 0.4 --- -- -- 0 25 .._..---- -- ..._. ........... Subtotals -.. -- r structure: 1,626 0 5,726 Infil.: Win. 2.5, Sum.: 1.1 56 1.375 77 0.339 48 19 Ductwork:111 467 1,069 Room Tot I I I I I Is: 2,170 48 6,814 Q\ ...\Ri k Residence.rh9 Tuesday, September 02, 2014, 8:40 AM .'MI : Residential '6idsnti;l E & Light CommerciiiHVAC IS , ergy Galc"s Elite Software Development, lnc.'' LL RI iik Residence ;Rt aon Port SaintLu"ie,'FL 348 , Pa Detaile '; Room Loads -Room 13. -,Den" (Peak, Fenestration -Gain Procedure)- Room is in one 2, which peaks at 5 pm Calculation Mode: Htg. & clgi Occurrences: 1 Room Len h: 17.0 ft. System Number: 1 Room Wid : 10.0 ft. Zone Number: 2 Area: 170.0 sq.ft. Supply Air: 312 CFM Ceiling Hei ht: 8.0 ft. Supply Air Changes: 13.8 AC/hr Volume: 1,360.0 cu.ft. Req. Vent. Clg: 0 CFM Number of egisters: 0 Actual Winter Vent.: 3 CFM Runout Air: 101 CFM Percent of Supply.: 1 % Runout. Duct Size: 6 in. Actual Summer Vent.: 4 CFM Runout Air i elocity: 539 ft./min. Percent of Supply: 1 % Runout Air elocity: 531i ft./min. Actual Winter Infil.: 10 CFM Actual Ws : 0.186 in.wg./100 ft. Actual Summer Infil.: 4 CFM Item �fi Area* 11 lot rSen,sk CIS° Latr �rSen hfg Descri too . .r ,` '=' b_...:Quantl, :Value�HTM� r �LossF M4 HTM ,,Gain ;h , . - Ga .. E -Wall-13 ' 5ocs 10 X 8 65 0.125 3.5 228 1.9 0 124 SW-Wall-1 X -5ocs 17 X 8 97 0.125 3.5 340 1.9 0 186 E -GIs-lA-c -o shgc-0.75 0%S 15 1.080 30.2 454 56.5 0 848 SW-GIs-1A b-o shgc-0.75 4%S 15 1.080 30.2 454 108.5 0 1,628 SW-GIs-10 -m shgc-0.534%S (2) 24 1.670 46.8 1,122 91.2 0 2,188 UP-Ceil-16 -30 17 X 10 1170 0.032 0.9 152 1.3 0 218 Floor-20P-3�� 10 X 17 170 0.035 1.0 167 0.4 0 60 Subtotals fo1r Structure: 2,917 0 5,252 Infil.: Win.: .6, Sum.: 4.4 216 1.370 296 0.338 184 73 Ductwork: j 882 1,076 People: 200 lat/per, 230 sen/per: 2 400 460 Room Total : I 4,095 584 6,861 C:\ ...\Rizk f�esidence.rh9 Tuesday, September 02, 2014, 8:40 AM Rhvac' Res ential 8� Light Commercial HVAC Loeds Elte:Software Development, Inc E? 'sitlential E iergyCalc s i Rizk Residence; PortSaint'Lu` ie; FL 3 4983 Pa" a 21 $' stern 4Room. Load :Summary `.� ��` '" :a�; ��`�.`,�' � � �SF�` •'B� 3 ` �g ��,�Vel� '13tuh,r� Btuh, CFIUf ,�� �CFNIk ---Zone 1--' 1 Kitch n 320 7,601 99 4-6 550 9,488 875 432 432 2 Dinin 1 95 7§5 10 1-4 153 293 348 13 13 3 Livin 176 4,603 61 2-5 590 3,537 480 161 161 4 Stain ay 77 775 10 1-4 139 267 48 12 12 5 Foye � 57 66 11 1-4 215 413 339 19 19 Zon 1 subtotal 724 14,670 191 13,997 2,090 637 637 ---Zone 2- 6 Bath 77 1,472 19 1-4 634 1,216 443 55 55 7 Mast r Bath 126 1,547 20 14 500 959 443 44 44 8 Mast kr Bedroom 272 4,732 62 3-5 539 4,842 755 220 220 9 Walk In Closet 42 449 6 1-4 121 231 48 11 11 10 Bedr om 2 182 2,6�0 35 2-5 532 3,187 684 145 145 11 Laun ry 54 129 2 1-4 54 104 600 5 5 12 Sta1 ay 70 2,170 28 3-6 526 6,814 48 310 310 13 Den.1 170 4,065 53 3-6 530 6,861 584 312 312 Zon ,2 subtotal 993 17,2 4 224 24,215 3,605 _ 1,102 1,102 Vend ation 769 412 1,038 Duct Latent 1 1,440 Syst m 1 total_ 1,717 32,6 3 415 - 32,625 8J73 1,466 1,466 System 1 h _ ain Trunk Size: 14x17 in. Velocity: 88 ft./min Loss per 11; 0 ft.: 0.101 in.wg Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the roo and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal th, totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass s'� nsible gain for the zone is at its peak. Sensible gains at the system level are based on the "Average Load Procedure Excursion" method. Conlin S" __ tem Summa , :' _ - ?'. Coolm"z�:Sensible/Latent` 56 �Sensible' 'y;.. Latent �_��* w� '� "Tons r .�.-..,..2....... � � S 11t � � � �s. a.-6tuh..;.Btuh..:. , . t " Btuh:. Net Requir' d: 3.40 80% / 20% 32,625 8,173 40,798 Actual: 3.54 78% / 22% 33,000 9,500 42,500 j,,,E Uipment POta Heating System Cooling System Type: Electric Resistance Standard Air Conditioner Model: RAH24A10J OR EQUIVALENT RAPLO42JEZ OR EQUIVALENT Indoor Mod I: RHLLHM4821JA OR EQUIVALENT Brand: P ESTIGE SERIES PRESTIGE SERIES Description SPP IT SYSTEM SPLIT SYSTEM 16 SEER Efficiency:' 0°/ 16 SEER Sound: 0 0 Capacity: 42,500 Btuh 42,500 Btuh Sensible C, pacity: n/a� 33,000 Btuh Latent Cap city: n/a� 9,500 Btuh AHRI Refe ence No.: n/a 1283265 C:\ ...\Rizk I esidence.rh9 Tuesday, September 02, 2014, 8:40 AM