HomeMy WebLinkAbout1404-0377-REVISION ENERGY EFFICIENCY CODE,
D3 72
FORM0.10
IFt IDA ENERGY EFFICIENCY C
Irida Department of Business and Professi
UV:
Method
T
`ject Name: Rizk Residence Builder Name:
eat: Lot 1234 Nettles Blvd. Permit Office: St. Lucie County
City, State, Zip: Ft. Pierce , F ., , Permit Number: .
Owner: .. • Jurisdiction: A/�/��
Design Location: FL, Fort Pier ~�,I� . 1 !' pp"
po.
1. New construction or existing
New (From Plans)
',!e ''�► lation
9. Wall Types a. Concrete (B Block - Int nsul, Exterior1928.0 sqft.),o�lf?�p50
Area
1720.00 ft-
2. Single family or multiple family
Single-family
b. Frame - Wood, Exterior
R=40
208.00 ft'
3. Number of units, if multiple family
1
c. N/A
R=
ft2
dN/A
R=
ft2
4. Number of Bedrooms
2
.
10. Ceiling Types (823.0 sqft.)
Insulation
Area
'
5. Is this a worst case?
No
a. Under Attic (Vented)
R=19.0
823.00 ft2
6. Conditioned floor area above grade (ft2)
1717
b. N/A
R
ft
c. N/A
Conditioned floor area below grade (ft2)
0
11. Ducts
R ft2
7. Windows(272.5 sqft.) Description
Area
a. Sup: RoomsInBlockl, Rat: RoomslnBloCk1, AH:
6 164.E
a. U Factor: Sgl, U=0.29
268.50 ft2
SHGC: SHGC=0.30
Cooling systems
kBtu/tir
Efficiency
b. U-Factor: Gbl, default
4.00 ft2
a.
a. Central Unit
42.0 SEER:16.00
SHGC: Clear, default
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr
Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
42.0
COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC:
0.304
14. Hot water systems
a. Electric Tankless
Cap: 1 gallons
8. Floor Types (993.0 sqft.)
Insulation Area
EF: 0.990
a. Slab -On -Grade Edge Insulation
R=0.0 993.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.159
Total Proposed Modified Loads: 28.31
PASS
Total Standard Reference Loads: 38.76
I hereby certify that the plans and spkc°ficati6-ns co d by
this calculation are in compliance with the Florid nergy
Code.
PREPARED BY: &ANI PL &y 4109
DATE: /hy'I -
I hereby certify that this bull 'ng, as designed, is in compliance
with the Florida Energy C
OWNER/AGENT:
�M�L-
DATE: -
- Compliance requires completion of a
1/24/2015 11:13 AM
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is.completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
it B�� ier and Insulation Inspection Checklist
ST, LUCIE COUNTY
BUILDING DIVISION
Pon C® ,o c
REVIEWED BY /
DATE
PLANS AND PERMIT
MUST BE KEPT ON JOB OR
NO INSPEn rinki XAM ,
.V ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 73
Tne lower the EnergyPerformance Index, the more efficient the home.
1. New cons ruction or existing
2. Single fa �ii ly or multiple family
3. Number olil units, if multiple family
4, Number ofl Bedrooms
5. Is this a orst case?
6. Condition d floor area (ft2)
Description
7, Windows I Sgl, U=0.29
a. U-Fact' r:
SHGC II SHGC=0.30
b, U-Fact, r:
Gbl, default
SHGC II Clear, default
c. U-Fact NIA
SHGC II NIA
d. U-Fact r.
Area vu
Area N
8. Floor I
a. Slat
b. NIA
c. NIA
I certify thatl
Constructiol
in this home
based on in
Builder Sigi
Address of
Average Overhang Depth:
Average SHGC:
Edge Insulation
Lot 1234 Nettles Blvd., Ft. Pierce, FL,
Insulation
Area
New (From Plans)
g. Wall Types
a. Concrete Block - Int Insul, Exterior
R=5.0
R=19.0
1720.00 ft2
208.00 ft2
Single-family
b. Frame - Wood, Exterior
R=
ft2
c. NIA
R=
ft2
1
d. NIA
insulation
Area
2
10. Ceiling Types
R=19.0
823.00 ft2
a. Under Attic (vented)
R_
ft2
No
b. NIA
R=
ft2
W17
c. NIA
R ft2
Area
11. Ducts Ret: RoomslnBlock1,
AH:
6 164.
268.50 ft2
a. Sup: RoomsinBlock1,
4.00 ft2
12. Cooling systems
kStulhr
42.0
Efficiency
SEER MOG
a. Central Unit
ftz
kBtulhr
Efficiency
ft2
13. Heating systems
42.0
COPA -00
a. Electric Strip Heat
1.000 ft.
0.304
14. Hot water systems
1 gallons
Cap: 9
Insulation Area
a. Electric
EF: 0.91
R=0.0 993.00 ft2
ft2
R=
b. Conservation features
R= ft2
None
CF, Pstat
15. Credits
this home has complied with the Florida Energy Efficiency Code for Building
'through the above energy saving features which will be l(completed
)
1Ibefore final in ection.f ath Otherwise, a new EPL Display
talled Code mpliant _ G
Date: l
I ture:
II L City/FL Zip: �i S
qualify for energy efficient
If our Index is below 70, your home may q Gauge Hotline at (321)
*Note: This is not a Building Energy Rating. Y Gauge Rating. Contact the Energy
Gauge
ge (EEM) incentives if you obtain a Florida Energy
au euge for information and a list of certified Raters. or
638-1 2 or see the EnergyGauge web site at energyg 9
�11 Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
;nfnrm tion about the
staff. ll
Conservation, if not DEFAULT.
**Labe ,� required by Section 303.1.3 of the Florida Building Code, Energy
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
1; l - -
-ayccOr 0- - - 1�
---- -- -
i.
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
-
-
1
$
Exterior
Concrete Block - Int InsGIoomslnBloc
5 32
16
512 ft2
0 0.75
0
2
:I
N
Exterior
Concrete Block - Int Ins8IoomslnBIoc
5 20
16
320 ft2
0 0.75
0
3
I
Exterior
Concrete Block - Int Ins5loomsInBloc
5 21
16
336 ft2
0 0.75
0
4
E
Exterior
Concrete Block - Int InsGIoomsInBloc
5 29
16
464 ft2
0 0.75
0
5 P,
W
Exterior
Frame - Wood RoomslnBloc
19 15
8
120 ft2
0.23 0.75
0
6
E
Exterior
Frame - Wood RoomslnBloc
19 11
8
88 ft2
0.23 0.75
0
7 1
JE
Exterior
Concrete Block - Int InsBloomslnBloc
5 11
8
88 ft2
0 0.75
0
DOORS
Omt
Door Type Space
Storms U-Value
Width
Height
Area
J
Ft
In
Ft In
E
Wood RoomslnBloc
None
0.460000 3
7
21 ft2
NW
Wood RoomslnBloc
None
0.460000 3
7
21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
v #
Omt ID
Frame Panes NFRC U-Factor SHGC
Storms Area
Depth
Separation
Int Shade
Screening
1
S 1
Metal Single (Tinted) Yes
0.29 0.3
N
40 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
2
!
S 1
Metal Single (Tinted) Yes
0.29 0.3
N
24 ft2
1 ft 0 in
0 it 0 in
HERS 2006
None
3
S 1
Metal Single (Tinted) Yes
0.29 0.3
N
54 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
4
i
fV 2
Metal Single (Tinted) Yes
0.29 0.3
N
12 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
5
W 3
Metal Single (Tinted) Yes
0.29 0.3
N
18 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
6
W 3
Metal Single (Tinted) Yes .
0.29 0.3
N
22.5 ft2
1 ft 0 in
0 ft0 in
HERS 2006
None
7
W 3
Metal Single (Tinted) Yes
0.29 0.3
N
6 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
8
E 4
None Glazed Block No
0.6 0.6
N
4 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
9
i
E 4
Metal Single (Tinted) Yes
0.29 0.3
N
9 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
10
'
E 4
Metal Single (Tinted) Yes
0.29 0.3
N
6 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
11
SE 6
Metal Single (Tinted) Yes
0.29 0.3
N
42 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
12
SE 7
Metal Single (Tinted) Yes
0.29 0.3
N
35 ft2
1 ft 0 in
0 ft 0 in
HERS 2006
None
GARAGE
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
382.8 ft2 382.8 ft2
64 ft
8 ft
1
INFILTRATION
# Scop
Method SIA CFM 50 ELA
EgLA
ACH
ACH 50
1 BySpa
;I s
Proposed SLA 0.000360 . 1621.3 89.009
167.39
0.3235
7.0821
1/24/2015 1:13 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
it I
11i ,
�I
HEATING SYSTEM
ill System Type
Subtype
Efficiency
Capacity
Block
Ducts
1 ! Electric Strip Heat
None
COP: 1
42 kBtuthr
1
sys#1
COOLING SYSTEM
System Type
Subtype
Efficiency
Capacity
. Air Flow
SHR
Block
Ducts
1 Central Unit
I
None
SEER: 16
42 kBtu/hr
1260 cfm
0.75
1
sys#1
II
HOT WATER SYSTEM
#'III System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 I Electric Tankless
Garage
0.9108 1 gal 50 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FS C
Collector Storage
Ce # Company Name
System Model # Collector
Model
# Area
Volume
FEF
No I'e None
�I
ft2
�I
DUCTS
— Supply —
— Return —
Air
Percent
HVAC #
# 'i Location R-Value Area
Location
Area Leakage Type
Handler
CFM 25
Leakage QN
RLF
Heat Cool
1 ! RoomslnBloc 6 164.6 ft RoomslnBioc 41.15 ft DSE=0.88
RoomslnBl 0.0 cfm
0.00 % 0.00
0.60
1 1
I
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Co in VenFebX� MarXj
t
Apr
AprX�
May Jun f Xj Jul
AugRj
Rj
Sep
Oct0
Nov
NovX
Dec
Dec
ngX� Janan Xj
Jun (X Jul
Aug
Sep
X
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type I 1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
II
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78
78
78
78
78
PM 78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) I AM 66
66 66
66 66 68
68
68
68
68
68
68
I, PM 68
68 68
68 68 68
68
68
68
68
66
66
1/24/2015 11:13 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 4
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRE S: Lot 1234 Nettles -Blvd. PERMIT #: I
Ft. Pierce. FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
coMPo ENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leaka 'e
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermost
&
403.1
At least one thermostat shall be provided for each separate heating and
it
-contro
cooling system. Where forced -air furnace is primary system,
`
programmable thermostat is required. Heat pumps with supplemental
11
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
jl
primary air containment passageways for air distribution systems shall
I�
be considered ducts or plenum chambers, shall be constructed and
t
sealed in accordance with Section 503.2.7.2 of this code.
l403.3.3
Building framing cavities shall not be used as supply ducts.
Water hea
ers
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
i
+ accessible manual OFF switch.
Mechanica
II
403.5
Homes designed to operate at positive pressure or with mechanical
ventilati
n
ventilation systems shall not exceed the minimum ASHRAE 62 level.
II
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming
,cools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
I
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
j
minimum COP= 4.0.
Cooling/hea
ing
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipme
t
occasion cooling or heating capacity requires separate system or
j
variable capacity system. Electric heat >10kW must be divided into two
I
or more stages.
Ceilings/kne'i
walls
405.2.1
R-19 space permitting.
1 /24/2015 11:13 M
�I
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Page 5 of 5