HomeMy WebLinkAbout20070442 ENERGY EFFICIENCY CODE• �' Gam'/�'`/ Y L Whole Building Performance Method for Commercial Buildings Form 40OA-97 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs FLA/COM-97 Version 2.2 PROJECT NAME_WETZEL CONSTRUCTION ADDRESS: FT. PIERCE OWNER: _WETZEL CONSTRUCTION AGENT: SCANNED BY PERMITTING OFFICE: _Fort Pierce CLIMATE ZONE: 6 PERMIT NO: JURISDICTION NO: 661100 BUILDING TYPE: _Business (Office) CONSTRUCTION CONDITION: New construction DESIGN COMPLETION: _Finished Building CONDITIONED FLOOR AREA: _2250 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 5 COMPLIANCE CALCULATION: NUMBER OF ZONES: 1 METHOD A DESIGN CRITERIA RESULT ----------------- -------------- ------ A. WHOLE BUILDING 77.53 100.00 PASSES PRESCRIPTIVE REQUIREMENTS: LIGHTING LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. SEER 10.00 10.00 PASSES HEATING EQUIPMENT 1. Et 10.00 N/A AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS 1. Ventilated 6.00 6.00 PASSES REHEAT SYSTEM TYPES USED NO REHEAT SYSTEM is USED WATER HEATING EQUIPMENT 1. EF 0.92 -51.90 PASSES PIPING INSULATION REQUIREMENTS 1. Circulating 1.00 1.00 PASSES ---------------------------------------------------------------------------- COMPLIANCE CERTIFICATION: I hereby certify that the plans nd specifications cc v r d by this c cu- lation are in c ian wi Florida Ener ic' cy e PREPARED BY: DATE: I hereby certify that this building is in compliance with the Florid E ergy Efficiency e. OWNER/AGENT: o DATE:— 0010 let Review of the plans and specifica- tions covered by this calculation indicates compliance with the Florida Energy Efficiency Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, Florida Statutes. BUILDING OFFICIAL: DATE: I•hereby certify(*) that the system design -is in compliance with the Florida Energy Efficiency Code. SYSTEM DESIGNER REGISTRATION/STATE ARCHITECT : MECHANICAL: PLUMBING ELECTRICAL: LIGHTING (*) Signature is required where Florida law requires design to be performed by registered design professionals. Typed names and registration numbers may be used adhere all relevant information is contained on signed/sealed plans. OFA OFF 0 1 W OD �1 1 • I I tij I • I I • I I 1 N I I 1 rot/] I I I I (D ';I I 10 1 (D 1 F•I• I (D I n l 1 (•1• I I rt I I I I F'i I I I 1 F-I 1 Fl- ca oa H(D I H(D I Hm I �m 1 z l zFJ- I-I• H ct 1 (n 1 (n 1 O a I k I kW I 1 0 I 1 1-3 (n y �r i I I (n I (n I I 1 I I I � 1 I t I I 1 (D I I I I I I (D 1 I 1 I 1 I I I I I 1 I Ijj I I I 1 I 1 (D 1 I I I I K I 1 1 I 1 f'h I I I I 1 I 0 I 1 I 1 1 z l I I I N I 0 I I 1 1 1 (D 1 t I 1 I tij I I 1 I z I 1 hit 1 1 I N I 0 1 I I F-I• I tP I I I 10 1 0 1 I 1 I F-I• I J 1 I I I (D I I I I 1 tj I N I I I tij 1 I F•h 1 O I I•�j I � 1 1 I hit 1 I I I I I-+• 1 I H I �•' I I f m 1 1 b l I I I I0 1 I r l 1 I F� I (� I WOO 10 1 IC 1 I I I I 1 I I I 1 1 1 1 1 I 1 I I 1 I I 1 I I I I I 1 I I 1 I 1 1 t I I 1 I 1 I 1 I I I I I I I I I I I 1 1 I 1 bd l I I I W I I 1 1 1 n 1 to I 1 In I y l I x I O I\ I • 1 0 1 1 tij 1 0 0 1 O 1 1 n 1 O I K I O I m I I x 9 l� n H r rn k (n y x O H F'h F.I. F� rt K a rt n K rt (D K a to 0 ON FJ n� C7 (D tr (D (D m rt x L�] n 75' I I I I I I I I I 1 I I I 1 I 1 rt N w F-' CL LQ O O I-n I N ko w a rt rt y I O 1 rt I a I F� 1 O 3 I O 0 I n rh a I O O Ili I K I 1 rt (D ►a -I a 1 O (n I t-h 0 ~ K O I � (D 1 m I••I I F-J 1 1 1 I I 1 1 I tzj to I H O 1 (D w 1 1 a 1 I rt I I N• I I 0 1 I � 1 r d W m z z 1 w& m0Km I•m I rt 1 I F-I • 1 1 0 1 I � 1 I O W W W W I I O \ \ \ \ I 1 PC to A. to to I r (D ca ' = = I (D (n I 1 cn co Cl) (A I I I I rt rt rt rt I I O O O O O I O I trJ NNNN I 1 Fi I (D la I I I M I ('r O O O 1 FJ QC�C�Oe I t F-'NNF•' 1 I C1C1C1C1 1 0 0 0 0 1 I 0 0 0 0 1 I � rhd rhd rhd I OPH F~-I FA w w 1 a SI)w a 1 p rt rt rt rt I 1 y rT rt rt rt I I O z \\\\ I 1 rt a ;�K �K ;�K I I I--IF�OCIiOO I IOm I m a 0000 1 I m I m m m m 1 Z o 1 I a O o o o 1C', 1 F••' N 1 F'0 0 I K I m I (D I t a F•�I I F•� 1 FJFAfJFA I I II II P H I_I F-I I 'riJ FA FA IP Io FJ tP to to N N-t 00(n K O m m I-h rt zwwzvm I w& Km0Kmm 1 FJ (D rt rt rt rt rt rt I •1 ��' ,'3' �' I QI I ,rt 1 � I F•I• 1 I 0 I 1 NN(D(DN(D I.tC.�,7! m m m m m m I N N• Fes. Fi. P. P. Fj. I (D H macaDmmm rt rt rt rt rt rt I I F'• W F-' F' I-' F'• 1 N NNNwNN tz=j I yNI-tF-'NF�F•' 1 O M0)MMMM I Ct rt NI I (,� 1 (n N N 1 n a m m 1 H I r N 1-I H N H H H i y a m(D ((DD (D c(DD m i a mO I tb m I (D 1 I II II 1 I I K 1 m I a I � I W W I Fit H H W W O H W W W N I— n 3 to x nn x tij (CHECK Ventilation Criteria in 409.1.ABCD have been met. 410.-----AIR DISTRIBUTION SYSTEM---------------------------------------- --- CHECK ------------------------------------------------------------ ---- --- Duct'sizing and design have been performed. (410.1.ABCD) .AHU Type Duct Location R-value ---------------------------------------------------------------- 1. Air Conditioners Ventilated 6 CHECK ------------------------------------------------------ ---- --- Testing and balancing will be performed. (410.1.ABCD) 411.-----PUMPS AND PIPING -ZONE ----------------------------------------- --- • Basic prescriptive requirements in 411.1.ABCD have been met. PLUMBING SYSTEMS 411------ PUMPS AND PIPING -ZONE 1--------------------------------------- --- Type R-value/in ---------- Diameter -------- Thickness --------- 1. ------------------------ Circulating 4 .75 1 412------ WATER HEATING SYSTEMS -ZONE 1---------------------------------- --- Type Efficiency StandbyLoss InputRate Gallons 1. Electric(<=12 KW) .92 1 40000 40000 ELECTRICAL SYSTEMS CHECK 413------ ELECTRICAL POWER DISTRIBUTION---------------------------- ----- --- Metering criteria in 413.1.ABCD have been met. 414------ MOTORS --------------------------------------------------- ----- --- Motor efficiencies in 414.1.ABCD have been met. 415------ LIGHTING SYSTEMS -ZONE 1--------------------------------------- --- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- ----------------- --- ------ ---------- Reading, T 1 On/Off 5 4050 2250 Total Watts for Zone 1 = 4050 Total Area for Zone 1 = 2250 Total Watts = 4050 Total Area = 2250 CHECK Lighting criteria in 415.1.ABCD have been met. 16. Operation/maintenance manual will be provided to owner.(102.1) ---------------------------------------------------------------------------- SIN RNW21393 RIGHT-N ZONE SUNIIVIARY Units: U.S. customary (I—P) For: WOLF AIR CONDITIONING By Job #: WOLF AIR CONDITIONING Jul 20, 2000 Zone: OFFICE COOLING LOAD 1. DESIGN CONDITIONS at 3 PM Peak load at 3 PM Inside: 75 OF Outside: 90 OF TD: 15 OF RH: 50 % Moisture: 61 gr/lb Mule: 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 11606 - 3. TRANSMISSION GAINS Sensible 20109 - Walls: 1078 - - Glass: 1920 - - Doors: 1080 - - Partitions: 0 - - Floors: 0 - - Roofs/Ceilings: 8831 - - Retum Air Ceiling: 7200 - - 4. INTERNAL HEAT GAIN Sensible Latent 8035 2000 Occupants: 2500 2000 - - Lights: 5535 0 - - Motors: 0 0 - - Appliances & Other: 0 0 - - 5. INFILTRATION: Outside air cfm: 40 660 1670 6. SUBTOTAL: Space load 40410 3670 7. SUPPLY DUCT 2020 - 8. SUBTOTAL: Bldg comp's and supply duct 42430 - Actual cfm: 1929 at Supply TD: 20 - - 9. VENTILATION: Make—up air cfm: 200 3300 8352 10. RETURN AIR LOAD: Lighting & roof (net) 4871 - 11. RETURN DUCT 1212 - 12. TOTAL LOADS ON EQUIPMENT 51814 12022 HEATING LOAD 13. DESIGN CONDITIONS Muk: 1.0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 18256 Walls: 2596 - Glass: 3584 - Doors: 2016 - Partitions: 0 - Floors: 3760 - Roofs/Ceilings: 3150 - Retum Air Roof 3150 - 15. INFILTRATION: Outside air cfm: 181 5583 16. SUBTOTAL: Building components 23839 17. SUPPLY DUCT: 2384 18. VENTILATION: Make—up air cfm: 200 6160 19. HUMIDIFICATION 4 613 20. RETURN DUCT 715 21. TOTAL HEATING LOAD ON EQUIPMENT 37711 Manual N: 4th Edition Right-N: Ver.3.0.04 Certified by ACCA to meet all requirements of Manual Form N Job #: Page: 3 15. INFILTRATION Loss 181 cfm x db Temp Diff 28.0 x 1.1 5583 . 16. SUBTOTAL HEATING LOAD FOR SPACE 23839 17. SUPPLY DUCT HEAT LOSS Loss factor 0.10 x Line 16 Loss 2384 18. VENTILATION 200 cfm x db Temp Diff 28.0 x 1.1 6160 19. 8UMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 2.0 (Max = 5 2.0 for 2 pane ) 381 cfm x 3.20 g/100cfm/d = 12.2 gpd 4613 20. RETURN DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 715 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 37711 Manual N: 4th Edition Right-N: Ver.3.0.04 Certified by ACCA to meet all requirements of Manual Form N ' Job #: Page: 2 Appl. Nmbr Type Sens Latent Usage 1 1 0 0 1.00 0 0 2 1 0 0 1.00 0 0 3 1 0 0 1.00 0 0 4 1 0 0 1.00 0 0 5 1 0 0 1.00 0 0 ' Other 1 0 0 1.00 0 0 5. INFILTRATION Sens Latent 40 c fm > x db Temp Diff 15.0 x 1.1 660 > x Moist. Diff I 61.4 x 0.68 1670 ' 6. SUBTOTAL COOLING LOAD FOR SPACE 40 410 3670 7. SUPPLY DUCT HEAT GAIN Gain factor 0.05 x Line 6 Sensible Gain 2020 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawdu u Fan = 42430 (L 8 Sens ) / (1.1 x Supply TD ) = cfm Est Cooling cfm = ( 42430) / ( 1.1 x 20.0 ) = 1929 Actual Cooling Fan > = 1929 9. VENTILATION 200 cfm > x db Temp Diff 15.0 x 1.1 3300 > x Moist. Diff 61.4 x 0.68 8352 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Incandescent Lights 0 Watts x 3.4 x 40% 0 Fluorescent Lights 2250 x 4.1 x 40% 3690 RA Roof Load from Line 3 M 8381 RA Ceiling Load Credit from Line 3 (-) 7200 11. RETURN DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 1212 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 51814 12022 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 4 2) = 28 [ Mult = 1.0 ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ 1 s 80 80 0.500 28.0 1120 GLAZ 1 N 80 80 0.500 28.0 1120 GLAZ 1 W 64 64 0.500 28.0 896 GLAZ 1 E 32 32 0.500 28.0 448 VU1LL 1 s 450 370 0.079 28.0 818 VU,LL 1 N 450 350 0.079 28.0 774 WALL 1 W 405 341 0.079 28.0 754 VUUL 1 E 185 113 0.079 28.0 249 DOOR 1 E 40 40 1.200 28.0 1344 DOOR 1 N 20 20 1.200 28.0 672 FLOR 1 - 166 166 0.810 28.0 3760 ROOF 1 - 2250 2250 0.050 28.0 3150 Manual N: 4th Edition Right-N: Ver.3.0.04 Certified by ACCA to meet all requirements of Manual Form N SIN RNW213 93 RIGHT-N COMMERCIAL / INDUSTRIAL LOAD CALCULATION Jul 20, 2000 For: WOLF AIR CONDITIONING Zone: OFFICE Job #: City: Fort Pierce, FL, US By. WOLF AIR CONDITIONING LWH: 50.0 x 45.0 x 9.0 Units: U.S. customary (I-P) 1. DESIGN CONDITIONS - COOLING Outdoor Conditions Indoor Conditions • TOD Correction Difference 2. GLAZING SOLAR BEAT GAIN Type Dir Shad Tilt GLAZ 1 s N 90 GLAZ 1 N N 90 GLAZ 1 W N 90 GLAZ 1 E N 90 ( 3 PM , August ) Dry Bib RH Moisture Range Wet Bib 90 59 15 78 75 50 63 0 Page: 1 15 61 [ Mult = 1.0 ] - ( Lat = 27.00 ° N , Const Wt = M ) %ovr Area Sfact Shgf Shad Sens 0.0 80 0.89 38 1.0 2706 0.0 80 0.89 29 1.0 2065 0.0 64 0.89 88 1.0 5012 0.0 32 0.89 64 1.0 1823 3. TRANSMISSION GAINS Type Dir GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ 1 s 80 80 0.500 15.0 N - 600 GLAZ 1 N 80 80 0.500 15.0 N - 600 GLAZ 1 W 64 64 0.500 15.0 N - 480 GLAZ 1 E 32 32 0.500 15.0 N - 240 VU LL 1 s 450 370 0.079 D 13.5 N L 395 WALL 1 N 450 350 0.079 D 8.3 N L 229 GALL 1 W 405 341 0.079 D 9.6 N L 259 WALL 1 E 185 113 0.079 D 22.0 N L 195 DOOR 1 E 40 40 1.200 15.0 - - 720 DOOR 1 N 20 20 1.200 15.0 - - 360 FLOR 1 - 166 166 0.810 0.0 - - 0 ROOF 1 - 2250 2250 0.050 RC-1 78.5 - D 8831 RARF 1 - 2250 2250 0.050 RC-1 74.5 - - 8381 RACL 1 - 2250 2250 0.800 4.0 - - 7200 4. INTERNAL HEAT GAIN Sens Latent People 10 x Per person: sensible 250 latent 200 2500 2000 0 x Per person: sensible 300 latent 300 0 0 Lights Incandescents in RA Ceiling 0 x 3.4 x 60% 0 Fluorescents in RA Ceiling 2250 x 4.1 x 60% 5535 Incandescents other 0 x 3.4 x 100% 0 Fluorescents other 0 x 4.1 x 100% 0 Motors Nmbr Power Gain Load Fact Usage 1 1 0.00 0 1.00 1.00 0 2 1 0.00 0 1.00 1.00 0 3 1 0.00 0 1.00 1.00 0 Manual N: 4th Edition Right-N: Ver.3.0.04 Certified by ACCA to meet all requirements of Manual Form N S/N: RNW21393 Units: U.S. customary (I-P) For. WOLF AIR CONDITIONING By: WOLF AIR CONDITIONING •Jobe#: LOAD BREAKDOWNS Component Btuh/ ft2 Btuh % of Btuh Walls 2.2 2596 6.9 Windows 14.0 3584 9.5 Doors 33.6 2016 5.3 Ceilings 1.4 6300 16.7 Floors 0.8 3760 10.0 Partitions 0.0 0 0.0 Infiltration 1.2* 5583 14.8 Ducts 0.7* 3099 8.2 Humidification 1.0* 4613 12.2 Ventilation 1.4* 6160 16.3 Totals 8.4 * 37711 100 * Calculated per ft2 of floor area Component Btuh/ ft2 Sens. Btuh % of Btuh Walls 0.9 1078 2.1 Windows 52.8 13526 26.1 Doors 18.0 1080 2.1 Ceilings 4.6 20903 40.3 Floors 0.0 0 0.0 Partitions 0.0 0 0.0 Infiltration 0.1 * 660 1.3 Ducts 0.7* 3233 6.2 Internal Gains 1.8* 8035 15.5 Ventilation 0.7* 3300 6.4 Totals 11.5 * 51814 100 * Calculated per ft2 of floor area c Jul 20, 2000 OFFICE Heating Cooling Manual N: 4th Edition Right-N: Ver.3.0.04 Certified by ACCA to meet all requirements of Manual Form N re