Loading...
HomeMy WebLinkAbout20070442-DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCEST. LUCIE COUNTY SCAN& DEPARTMENT OF COMMUNITY DEVELOPMENT 2300 VIRGINIA AVENUE BY ..,s— FT. PIERCE, FL. 34982-5652 • "+�i�l561-462-1553 DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for building permit involving the construction of new residence (single or multi -family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no structural walls, columns or other similar component is being effected) and certain other minor building permits. For further assistance, please contact the Building Inspection Office at 462-1553 or 462-2172. PROJECT NAME OFFICE: USEONLY �I STREET ADDRESS PR NUMBER PERMIT NUMBER OCCP. TYPE I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. 1. STANDARD BUILDING CODE 1997 EDITION Y ASCE 7-95 OTHER (SPECIFY) 2. BUILDING DESIGN IS (CHECK ONE) ENCLOSED PARTIALLY ENCLOSED OPEN BUILDING 3. 1311IILDING HEIGHT: pAI �etrtt I�1"6 u fa�z FT 4. WIND SPEED USED IN BUILDING DESIGN: H O MPH S. WIND EXPOSURE CLASSIFICATION (REFER TO EXPOSURE TABLES IN BUILDING CODE IDENTIFIED IN LINE f1): Z'o ' fV 8. AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: PSF 0�d % 7. PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: PSF 1.0 8. IMPORTANCE/USE FACTOR (OBTAIN FROM BUILDING CODE): 9. LOADS: FLOOR jA PSF ROOF/DEAD: 5/ PSF' / ROOFAJVE: -54 PSF 10. WERE SHEAR WALLS CONSIDERED FOR STRUCTURE (CHECK ONE) YES +� NO If NO, why? (attach explaination) / V 11. IS A CONTINUOUS LOAD PATH PROVIDED (CHECK ONE) YES NO If NO, why? (attach wpfaination) 12 ARE COMPONENT AND CLADDING DETAILS PROVIDED (CHECK ONE) YES NO If NO, why? (attach eaplaination) 13. MINIMUM SOIL BEARING PRESSURE PSF AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION INCLUDED WITH THI ERTIFICATTON IS TRUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF. D NAME: r t� E�' T`�' CEO K CERTIFICATION NO: AP—q 4-, 5 I tftii �� 5. n k- ABC 46T�ET 7 I I HERE] DESIGN FIRM: ATE:JCL CDv FOP -'A NO.020.00 i aw ST LUCIE COUNTY FIRE DISTRICT BUREAU OF FIRE PREVENTION PLAN REVIEW 2400 Rhode Island Avenue Telephone: 561-462-2312 Ft Pierce, FL 34950 FAX: 561-462-2323 TYPE OF PERMIT (. )New Construction ( )Tenant Improvement ( j)(didition Jurisdiction: Occupancy: Address: Contractor Contractor's Address: Architect/Engineer: Building Owner: Occupancy Type: Gross sq ft: Occupant Load: Construction Type: St. Lucie County Charlie's Dodge 4815 S. Federal Hwy Wetzel Construction 131 N. 2nd St, Ste. 204 Peter Blake Cook Charlie's Dodge & Isuzu of Florida, Inc Industrial 4,800 ( )Renovation/alterations ( )Shell Only F. P. B.: B-00-219 Building Dept: 20070442 Number of stories: 1 Phone # 561-464-1977 City: Ft. Pierce Phone # 561-229-9197 Review Date: 8/1/00 Automatic sprinklers: Net sq ft: Based On: SBCCI Type: IV 1. All revisions must be in compliance before the final inspection. 2. The Fire Marshal requires 24 hour notice on all inspections. 3. Th respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 4. Pelrmit fees are required to be paid in full prior to any inspections. 5. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. A copy of the required revisions/s have been transmitted to the Architect ( ) Contractor ( ). REVISIONS REQUIRED KNOX BOX IS REQUIRED ( ) 1. Portable fire protection is shown. Provide 3A4013C extinguishers every 75 feet of travel distance 2. Installation of a fire protection system is required and under a separate permit. 3. Installation of the fixed fire protection system and the booth shall be in accordance with NFPA 33. 4. Two eixts are required. Provide a second exit door remote from the door shown. Overhead roll up door are not counted as exit doors. 5. Provide emergency and exit light fixtures accordingly. Reviewed by: / Date: 8/1 /00