HomeMy WebLinkAbout20070442-DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCEST. LUCIE COUNTY
SCAN& DEPARTMENT OF COMMUNITY DEVELOPMENT
2300 VIRGINIA AVENUE
BY ..,s— FT. PIERCE, FL. 34982-5652
• "+�i�l561-462-1553
DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE
This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications
for building permit involving the construction of new residence (single or multi -family), residential addition, any accessory structure requiring
a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no structural
walls, columns or other similar component is being effected) and certain other minor building permits. For further assistance, please contact
the Building Inspection Office at 462-1553 or 462-2172.
PROJECT NAME OFFICE: USEONLY �I
STREET ADDRESS
PR NUMBER
PERMIT NUMBER
OCCP. TYPE
I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE
BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES
CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS
DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED
BY CURRENT CODE PROVISIONS.
1. STANDARD BUILDING CODE 1997 EDITION Y ASCE 7-95 OTHER (SPECIFY)
2.
BUILDING DESIGN IS (CHECK ONE) ENCLOSED PARTIALLY ENCLOSED
OPEN BUILDING
3.
1311IILDING
HEIGHT: pAI �etrtt I�1"6 u fa�z FT 4. WIND SPEED USED IN BUILDING
DESIGN: H O MPH
S.
WIND EXPOSURE CLASSIFICATION (REFER TO EXPOSURE TABLES IN BUILDING CODE IDENTIFIED IN LINE f1):
Z'o ' fV
8.
AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE:
PSF
0�d %
7.
PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE:
PSF
1.0
8.
IMPORTANCE/USE FACTOR (OBTAIN FROM BUILDING CODE):
9.
LOADS: FLOOR jA PSF ROOF/DEAD: 5/ PSF' /
ROOFAJVE: -54 PSF
10.
WERE SHEAR WALLS CONSIDERED FOR STRUCTURE (CHECK ONE) YES +�
NO If NO, why? (attach
explaination)
/
V
11.
IS A CONTINUOUS LOAD PATH PROVIDED (CHECK ONE) YES NO
If NO, why? (attach wpfaination)
12
ARE COMPONENT AND CLADDING DETAILS PROVIDED (CHECK ONE) YES
NO If NO, why? (attach
eaplaination)
13.
MINIMUM SOIL BEARING PRESSURE PSF
AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION INCLUDED WITH THI ERTIFICATTON
IS TRUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF.
D
NAME: r t� E�' T`�' CEO K CERTIFICATION NO: AP—q 4-, 5 I
tftii �� 5. n k- ABC 46T�ET 7 I I HERE]
DESIGN FIRM: ATE:JCL
CDv FOP -'A NO.020.00
i
aw
ST LUCIE COUNTY FIRE DISTRICT
BUREAU OF FIRE PREVENTION
PLAN REVIEW
2400 Rhode Island Avenue Telephone: 561-462-2312
Ft Pierce, FL 34950 FAX: 561-462-2323
TYPE OF PERMIT
(. )New Construction ( )Tenant Improvement ( j)(didition
Jurisdiction:
Occupancy:
Address:
Contractor
Contractor's Address:
Architect/Engineer:
Building Owner:
Occupancy Type:
Gross sq ft:
Occupant Load:
Construction Type:
St. Lucie County
Charlie's Dodge
4815 S. Federal Hwy
Wetzel Construction
131 N. 2nd St, Ste. 204
Peter Blake Cook
Charlie's Dodge & Isuzu of Florida, Inc
Industrial
4,800
( )Renovation/alterations ( )Shell Only
F. P. B.:
B-00-219
Building Dept:
20070442
Number of stories:
1
Phone #
561-464-1977
City:
Ft. Pierce
Phone #
561-229-9197
Review Date:
8/1/00
Automatic sprinklers:
Net sq ft:
Based On:
SBCCI Type:
IV
1. All revisions must be in compliance before the final inspection.
2. The Fire Marshal requires 24 hour notice on all inspections.
3. Th respective Building Department shall schedule all final inspections through the Fire Marshal's Office.
4. Pelrmit fees are required to be paid in full prior to any inspections.
5. Failed inspections require payment of fee prior to rescheduling of further inspections.
6. A copy of the required revisions/s have been transmitted to the Architect ( ) Contractor ( ).
REVISIONS REQUIRED
KNOX BOX IS REQUIRED ( )
1. Portable fire protection is shown. Provide 3A4013C extinguishers every 75 feet of travel distance
2. Installation of a fire protection system is required and under a separate permit.
3. Installation of the fixed fire protection system and the booth shall be in accordance with NFPA 33.
4. Two eixts are required. Provide a second exit door remote from the door shown. Overhead roll up door
are not counted as exit doors.
5. Provide emergency and exit light fixtures accordingly.
Reviewed by: /
Date:
8/1 /00