HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R j 5-2017 SCANNED
FLOR FDA ENERGY EFFICI�- VtLq, ,F FOR BUILDING CONSTRUCTION
Floral
a Department of Business and Professional Regulation - Residential Performance Method
Project Na
8401 Salemo Rd
Builder Name: Brain Markey
Street:
8401 Salemo Rd
Permit Office: St Lucie
City, State,lit,
p: Fort Pierce , FL , 34951
Permit Number: 1807-0740
Owner:Brain
Markey
Jurisdiction: 611000
Design Locn:
FL, ST_LUCIE_CO_INTL
County:: St. Lucie (Florida Climate Zone 2 )
1. New cons 111 ction or existing Existing (Projecte
9. Wall Types (1440.0 sqft.)
Insulation Area
2. Single fa ly or multiple family Single-family
a. Frame - Wood, Exterior
R=13.0 1208.00 if
b. Frame - Wood, Adjacent
R=13.0 232.00 ft2
3. Number o units, if multiple family 1
c. N/A
R= ft2
4. Number o Bedrooms 2
d. N/A
R= ft2
No
10. Ceiling Types (1545.0 sqft.)
Insulation Area
5. Is this a rst case?
a. Under Attic (Vented)
R=30.0 1545.00 ft2
6. Condition d floor area above grade (ftz) 1545
b. N/A
R= ft2
Condition d floor area below grade (ftz) 0
c. NIA
11 Ducts
R
R ft2
7. Windows 18.8 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 200
a. U-Fac ' r: Dbl, U=0.30 118.75 ft2
SHG SHGC=0.25
b. U-Fa I N/A ft2
12. Cooling systems
kBtu/hr Efficiency
r:
a. Central Unit
29.0 SEER:16.00
SHG
c. U-Fac or: N/A ft2
SHG
13. Heating systems
kBtu/hr Efficiency
d. U-Fa or: N/A ft2
a. Electric Strip Heat
26.0 COP:1.00
SHG
Area WI hted Average Overhang Depth: 2.000 ft.
Area W ghted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor T es (1545.0 sqft.) Insulation Area
EF: 0.950
a. Slab- n-Grade Edge Insulation R=0.0 1545.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF, Pstat
Area: 0.077 Total Proposed Modified Loads: 43.91
PASS
Glass/FI, or
Total Baseline Loads: 44.69
I hereby rtify that the plans and specifications covered by
Review of the plans and
OI-VEiE SxAr�
this calcu ation are in compliance the FlorifEgy
specifications covered by this
ti+ _ g ; 0��
Code.
calculation indicates compliance
y a,,. �'' ,=,•�;,o�a���
with the Florida Energy Code.
rrrrrr."?�''•:".•;:•� ,� O
PREPA ED BY:
DATE. 5 6
Before construction is completed
this building will be inspected for
compliance with Section 553.908
'� . f'""
* °
I hereby
rtify that this is incompliance
Florida Statutes.with
GOD
the
A,asded,
lorida Energy
WE
OWNE
AGENT'
BUILDING OFFICIAL:
DATE:
DATE:
- Comp lance requires Artification by the air handier unit manufacturer that the air handier enclosure qualifies as
certifi dfectory-sealed in accordance with R403.3.2.1.
- Compl ance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
I J ra 5 C Alftb
8/31/2 , 18 9:43 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Complian LSof P'Y.1 of 4
i
r:r)m PAn+o;119n17
II
PROJECT
Title:
Building T
Owner Na
# of Units.
Builder Na
Permit Offi
Jurisdictionj�
Family Typ
NewlExisti
Comment:
II
e:
II
8401 Salemo Rd
User
Brain Markey
1
Brain Markey
St Lucie
611000
Single-family
Existing (Projected)
Bedrooms: 2
Conditioned Area: 1545
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 8401 Salemo Rd
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
II'I
CLIMATE
V
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL,
T_LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90
70
75 299 58 Medium
BLOCKS
Number'I
Name
Area Volume
1
Blockl
1545 12360
II
SPACES
Numbed,11
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1545 12360 Yes 1
2
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 180 ft 0
1545 ft2
---- 0 0 1
ROOF
V
#
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Gable or shed Composition shingles 1628 ft2 256 ft2 Medium
0.85
No 0.9 No 0 18.4
ATTIC
V
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1545 ft2
N N
III
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1545 ft2 0.16 Wood
8l3112 18 9:43 AM
I
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 2 of 4
Gr)14hA PA a,_7n17
WALLS
V.
Adjacent
Space
Cavity Width Height Sheathing Framing Solar
R--Vaille Et In Ft In Area R--Vahle Fraction Absnr
Below
rradp0l.
_ 1
2
_ 3
4
5
6
N
N
E
S
W
E
Exterior Frame - Wood
Garage Frame - Wood
Exterior Frame - Wood
Exterior Frame - Wood
Exterior Frame - Wood
Garage Frame - Wood
Main
Main
Main
Main
Main
Main
13 39 8
13 14 8
13 22 8
13 53 8
13 37 8
13 15 8
312.0 ftz 0 0.75
112.01t2 0 0.75
176.0 ft2 0.16 0.75
424.0 ftz 0.16 0.75
296.0 ftz 0.16 0.75
120.0 ftz 0.16 0.75
0
0
0
0
0
0
DOORS
#
Omt Door Type
Space
Storms
U-Value Width Height
Ft In Ft In
Area
1
2
N Insulated
E Insulated
Main
Main
None
None
.21 3 6 8 20 ftz
.21 2 8 6 8 17.8 ftz
WINDOWS
Orientation shown is the entered, Proposed orientation.
�/
Wall
Omt ID Frame Panes
NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation Int Shade
Screening
1
N 1 Vinyl Low-E Double Yes
S 4 Vinyl Low-E Double Yes
S 4 Vinyl Low-E Double Yes
0.3 0.25 Y
0.3 0.25 Y
0.3 0.25 Y
47.3 ftz 2 ft 0 in 1 ft 0 in None
31.5 ftz 2 ft 0 in 1 ft0 in None
40.0 ftz 2 ft 0 in 1 ft 0 in None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1
266 ftz
266 ftz
33 ft
8 It 1
INFILTRATION
# S'lope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholl
house Proposed ACH(50)
.000254
1030 56.55 106.34 .1906 5
HEATING SYSTEM
-77
#
System Type
Subtype
Efficiency
Capacity Block
Ducts
1
Electric Strip Heat/
None
COP:1
26 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/
None
SEER: 16
29 kBtu/hr 870 cfm 0.75 1
sys#1
8/31/20� 8 9:43 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
FORM R
5-2017
r
i
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Main
0.95 40 gal 50 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftZ
DUCTS
— Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 200 ft"
Attic
77:25 ft Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Progra
able Thermostat: Y
Ceiling Fans:
coolingJan
Heatin
�]] Feb
Jan [X] Feb
Mar
Mar
Apr
p
[ May rl Jun IXI Jul
[ May ]Jun Jul
Au
ri Au
SeP
rl Se
Oct
WOct
Nov
Nov
HX
Dec
Dec
H
Ventin
Jan �j ]] Feb
X Mar
r
[ Ma [) Jun Jul
L
Aug
Se
Oct
Nov
Dec
Thermost
I t Schedule: HERS 2006 Reference
Hours
Schedule
Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling
D) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling
EH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating 0
JD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating
EH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
8/31 /2 8 9:43 AM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 4 of 4
Lb5-2017
i�
FORM
ENERGY
PERFORMANCE LEVEL
EPL
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX` = 98
The lower the EnergyPerformance Index, the more efficient the home.
8401 Salerno Rd, Fort Pierce, FL, 34951
1. New c
struction or existing
Existing (Projecte 9. Wall Types
Insulation
Area
2. Single
mily or multiple family
Single-family a. Frame - Wood, Exterior
R=13.0
1208.00 ft2
b. Frame - Wood, Adjacent
R=13.0
232.00 ft2
3. Numb
of units, if multiple family
1 c. N/A
R=
ft2
4. Numb
of Bedrooms
2 d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this
worst case?
No a. Under Attic (Vented)
R=30.0
1545.00 ft2
6. Condit
ned floor area (ft2)
1545 b. N/A
R=
ft2
c. N/A
R=
ft2
7. Windo
s" Description
:
U=0.30
Area
118.75 ft2 11. Ducts
R ft2
a. U-F
! ctor: Dbl,
a. Sup: Attic, Ret: Attic, AH: Attic
6 200
SH
C: SHGC=0.25
b. U-F
l ctor: N/A
ft2
SH
G C:
12. Cooling systems
kBtu/hr
Efficiency
c. U-F'
ctor: N/A
ft2 a. Central Unit
29.0 SEER:16.00
SH
C:
d. U- ;ctor: N/A
ft2 13. Heating systems
kBtu/hr
Efficiency
SH
Area V
C:
eighted Average Overhang Depth:
a. Electric Strip Heat
2.000 ft.
26.0
COP:1.00
Area V
eighted Average SHGC:
0.250
8. Floor
es Insulation Area 14. Hot water systems
Cap:
40 gallons
a. SlatOn-Grade
a. Electric
Edge Insulation R=0.0 1545.00 ft2EF:
0.95
b. N/A
R=
ft2
c. N/A
R=
ft2 b. Conservation features
None
15. Credits
CF, Pstat
I certify t lat this home has complied with the Florida Energy Efficiency Code for Building �TKE Sr-
21
Constru ion through the above energy saving features which will be installed (or exceeded) o = Fo
in this h e before final inspection. Otherwise, a new EPL Display Card will be completed r
based or installed Code c nt features. r,,,, „ xw';,aw�, o
o a
c
Builder gnature: ate: ya(,��v
Address f New Hom . i Vol � �j / City/FL Zip: WIE
J� g�
This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
e (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
port@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
sion's support staff.
el required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
12018 9:44 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
FORM 1405-2017 Envelope Leakage, -,t Report Performance
Project
Street:
City, St
Design
Cond. F
E
C:
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Performance Method
ne:
8401 Salemo Rd
8401 Salerno Rd
Zip:
Fort Pierce, FL , 34951
ation:
FL, ST LUCIE_CO_INTL
Area::
1545 sq.ft.
ope Leakage Test Results
-ion Data:
F11
Single r Multi Point Test Data
a
Builder Name:
Brain Markey
Permit Office:
St Lucie
Permit Number:1807-0740
Jurisdiction:
611000
Cond. Volume:
12360 cu ft.
HOUSE PRESSURE
FLOW:
1
Pa
cfm
2
Pa
cfm
3
Pa
cfm
4
Pa
cfm
5
Pa
cfm
6
Pa
cfm
Leakage Characteristics
Required ACH(50) from
FORM R405-2017 :
Tested ACH(50) * :
*Tested leakage must be less than or equal to the
required ACH(50) shown on Form R405-2017 for
this building. If the tested ACH(50) is less than 3
the building must have a mechanical ventilation
system.
R402. '� 1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in
Climate kones 1 and 2 ... Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either
individu I s as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved
third pa V. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be
perform' d at any time after creation of all penetrations of the building thermal envelope.
D ring testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other
infiltration control measures;
2. Dampers including exhaust, intake, makeup air, backdraft and Flue dampers shall be closed, but not sealed beyond intended infiltration
control measures;
3. Interior doors, if installed at the time of the test, shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and
6. Supply and return registers, if installed at the time of the test, shall be fully open.
I here y certify that the above envelope leakage
perfo - ance results demonstrate compliance
with F`lorida Energy Code requirements in
accon lance with Section R402.4.1.2.
DA
,TURE:
NAME:
Testing shall be conducted by either
individuals as defined in Section
553.993(5) or (7), Florida Statutes or
individuals licensed as set forth in
Section 489.105(3)(0(g), or (i) or an
approved third party. A written report of
the results of the test shall be signed
by the third party conducting the test
and provided to the code official.
BUILDING OFFICIAL:
DATE:
oITUE SrATF
D ��
8 9:44 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1