Loading...
HomeMy WebLinkAboutNOAN BY 9 . Lude countv FMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) AND CODE ADMINISTRATION DIVISION ITICE OF ACCEPTANCE I crap, Inc. Mission Way ,n, BC, Canada V2V-6E4 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidade.2ov/economv NOA is being issued under the applicable rules and regulations governing the use of construction materials. The mentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). Th p NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Se tion (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in thee, accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately reN ke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to re ke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or me i,erial fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code m eluding the High Velocity Hurricane Zone of the Florida Building Code. 'TION: Titanium° UDL-25 PLUS, Titanium" UDL-30, Titanium" UDL-50, UDL TT, UDL TF, UDL TTMC-300, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments TG: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following "Miami -Dade County Product Control Approved", unless otherwise noted herein. R NEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in, �he applicable building code negatively affecting the performance of this product. TI RMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the m' 'terials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, foji sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of��this NOA shall be cause for termination and removal of NOA. A!bVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the e , iration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done i� is entirety. 'ECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and be available for inspection at the job site at the request of the Building Official. is NOA renews and revises NOA No. 13-0610.01 and consists of pages 1 through 5. e submitted documentation was reviewed by Alex Tigera. NOA No.: 14-0603.18 Expiration Date: 08/08/18 Approval Date: 06/11/15 Page 1 of 5 -1— ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: Polypropylene SCOPE: This acceptance is for Titanium' UDL-25 PLUS, Titanium' UDL-30, Titanium' UDL-50, UDL TT, UDL TF, UDL TTMC-300, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSAi Synthetic Underlayments as described in this Notice of Acceptance, for use with approved prepared roof assemblies where ASTM D226 Type underlayment is specified and installed with prescribed approved fasteners and fastener li densities. Designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code PRODUCT DESCRIPTION: Test Product Product Dimensions Specification Description Titanium' UDL-25 PLUS 48" x 250' rolls ASTM D226 Woven synthetic polymer underlayment with Manufacturing Type I & lI side coated with UV protected and slip resist, Location #1 & #3 polymer stabilized polypropylene on both sid Titanium'UDL-30 Manufacturing Location #1& #3 48" x 250' rolls ASTM D226 Type I & lI Woven synthetic polymer underlayment with two sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. Titanium' UDL-50 Manufacturing Location #1& #3 48" x 250' rolls ASTM D226 Type I & 11 I Woven synthetic polymer underlayment with two sides coated with UV protected and slip resistant li polymer stabilized polypropylene on both sides UDL TT 48" x 250' rolls ASTM D226 Woven synthetic polymer underlayment with one Manufacturing Location #1 Type I & 11 side coated with UV protected and'slip resistant,, polymer stabilized polypropylene on both sides'. UDL TF Manufacturing Location #1 48" x 250' rolls ASTM D226 Type I & 11 Woven synthetic polymer underlayment with ttvo sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. UDL TTMC-300 Manufacturing Location #2 48" x 250' rolls ASTM D226 Type I & 11 Woven synthetic polymer underlayment with two sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sided i RhinoRoof U10 42" x 286' rolls ASTM D226 Woven synthetic polymer underlayment with two Manufacturing Location #3 Type I & 11 sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. NOA No.: 14-0603�18 Expiration Date: 08/08718 Approval Date: 06/1 %15 Page 2 If 5 ioRoof U15 42" x 286' rolls ASTM D226 Woven synthetic polymer underlayment with two ufacturing Type I and II sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. Von #3 ioRoof U20 42" x 286' rolls ASTM D226 Woven synthetic polymer underlayment with two ufacturing Location #3 Type I and II sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. UDL25 48" x 250' rolls ASTM D226 Woven synthetic polymer underlayment with two acing Location 93 Type I and II sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. if RSA 36" x 67' rolls ASTM D1970 Unreinforced polymer modified bitumen material. acing Location #4 adhered to the underside of a polymer -coated, synthetic woven sheet. The underside is backed with a release film. +ACTURING LOCATIONS: ML 1 ML2 ML3 ML4 E" IDENCE SUBMITTED: Test Agency nt, rtek Testing Services pity I ERD Test Identifier Test Name/Report Date #3031783 TAS 104 02/19/03 3119607COQ-00313 ICC-ES AC48 02/20/08. 3124826-01 ASTM E108 02/19/08 3124826MID-007 ASTM E108 02/25/08 311801OCOQ-003 ASTM D226 02/20/08 3130639COQ-002A ASTM D226 02/20/08 3146738COQ-003A ASTM D226 06/20/11 3146738COQ-003B ASTM D 1876/ TAS 117 03/28/08 101465036COQ-001 ASTM D1970 06/27/14 100539395COQ-006 ASTM D226 06/02/14 101863861COQ-OOIA ASTM D226 10/28/14 101823107COQ-0I 1 ASTM D226 12/09/14 I15010.05.10 ASTM D4798 / D226 05/14/10 138010.08.11 ASTM D226 08/11/11 I35520.08.11 ASTM D2523 / D1781 08/17/11 NOA No.: 14-0603.18 Expiration Date: 08/08/18 Approval Date: 06/11/15 Page 3 of 5 INSTALLATION SPECIFICATIONS: Titanium® UDL-25 PLUS, Titanium® UDL-30, Titanium° UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments 1. Titanium® UDL-25 PLUS, Titanium® UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF,, RhinoRoof U10, RhinoRoof Ul 5, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments shall be installed in strict compliance with applicable Building Code. 2. , Titanium® UDL-25 PLUS, Titanium® UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF', RhinoRoof U 10, RhinoRoof U 15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments shall be installed with a minimum 4-inch head lap in a shingle layer fashion. 3. Titanium® UDL-25 PLUS, Titanium® UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF!, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, and Titanium UDL25 Synthetic Underlayments shall >je fastened with Miami -Dade approved corrosion resistant tin -caps and 12 gauge 1 '/4" annular ring -shank nails, spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. in the field of the roll. 4. Titanium® UDL-25 PLUS, Titanium® UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TFI; RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments may be used with Asphaltic shingles, Wood shakes and shingles, Non-structural metal roofrig, and quarry slate. Titanium® UDL-30, Titanium® UDL-50, UDLTTMC-300, UDL TT, UDL TF, RhinoRoof U 10, RhinoRoof U 15, RhinoRoof U20, Titanium UDL25 and RhinoRoof RSA Synthetic Underlayments hall not be used as roof tile underlayments. i � 5. For Roof Tile applications; Titanium® UDL-25 PLUS may be used as an anchor sheet in roof tile applications when used in combination with a top membrane layer, consisting of a Miami -Dade approved TAS 103 self adhering underlayment. (See current NOA listing of approved TAS 103 self -adhering underlayment for installation guidelines and limitations of use). 6. For fire classification of specific roof assemblies using Titanium® UDL-25 PLUS, Titanium® UDL;30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments_ refer to a current Approved Roofing Materials Directory for fire ratings of this product. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. P � �I I NOA NO.: 14-060�118 Expiration Date: 08/08/18 Approval Date: 06/1/15 Page 4 I01 f 5 it L MITATIONS: 3. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. , Titanium® UDL-25 PLUS, Titanium® UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments shall be applied to a smooth, clean and dry surface with deck free of irregularities. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. Titanium® UDL-25 PLUS, Titanium® UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments shall not be hot mopped, refer to manufacturer's published literature for product compatibility. Titanium® UDL-25 PLUS, Titanium® UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments shall not be applied over an existing roof membrane as a recover system. Titanium® UDL-25 PLUS, Titanium® UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments shall not be left exposed as a temporary roof for longer than 30 days of application. UDL_TTMC-300 Synthetic Underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. Titanium® UDL-25 PLUS, Titanium® UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments are components used in roof system assemblies. Roof system assemblies are approved under a specific Notice of Acceptance. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Titanium® UDL-25 PLUS, Titanium® UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments may be used with any approved roof covering Notice of Acceptance listing Titanium® UDL-25 PLUS, Titanium® UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments as a component part of an assembly in the Notice of Acceptance. If Titanium® UDL-25 PLUS, Titanium® UDL- 30, Titanium® UDL-50, UDL TTMC 300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 14-0603.18 Expiration Date: 08/08/18 Approval Date: 06/11/15 Page 5 of 5