HomeMy WebLinkAboutFLOOR PLAN12
311
1
I
I
I \\
L-
C_!
ve CLG. DRYWALL
DOUBLE 2 x 4 PLATE
w/ SIMPSON 5114
4a EACH STUD
SEE HEADER DETAIL
ENGINEERED WOOD TRUSSES • 2411 O.C.
INSULATION (MIN R-30)
SIMPSON STRONG TIE MTSI& AT EACH RAFTER
SHINGLES OVER
ROOFING MEMBRANE
OVER IS/3211 CDX PLYWOOD NAILED
w/ 8D RING SHANK NAILS 6" IN FIELD
4 4" O.C, 4V EDGES
SEE ELEVATIONS FOR WALL HEIGHTS
l TOP OF BEAM )
�- METAL DRIP EDGE
IX2P.T.
2 X 6 FASCIA
NOTE: CONT. VENTED
OVERHANG VARIES ALUM SOFFIT
(SEE ELEVATIONS)
2 x 4 SPF STUDS
_
0 16" O.C. FRAME WALL
=;
MATCH EXISTING T-Ill SIDING
(DBL STUDS is WALL ENDS)
CC)
�
OVER VAPOR BARRIER
it?" WEDGE ANCHORS w/ 311x 311
x 411
WASHERS is 32" O.C. MAX,
1/2" DRYWALL
( MAX. &I FROM CORNERS )
R-13 INSULATION
( OR BETTER )
2 x4 PT SILL PLATE w/
SIMPSON SP4 • EACH STUD,
BASE
FRAME WALL STUDS A 16 O.C.
MAX.
_ADDITION FINISH FLOOR ELEV.
CAP (3000 PSI CONC. w/ FIBERMESH)
TOP OF SLAB
GRADE
CUT EXISTING PORCH SLAB 1811
6 MIL. VAPOR O O
MIN. (2) 054
BARRIER
REBAR
12
TYPICAL FRAME WALL is
REAR PORCH FRAME -IN SECTION
NOT TO SCALE
BASIC WIND SPEED 160 MPH 3.6EC. GUST
RISK FACTOR - II
BUILDING CATEGORY ENCLOSED
EXPOSURE CATEGORY _ B
INTERNAL PRESSURE COEFF, 0,18
WIND DESIGN PRESSURES -
GARAGE DOOR -34.1 / +38 PSF
ALL OTHER OPENINGS +36 / -41 PSF
FOUNDATION 4 SLAB NOTES FOR REAR PORCH FRAME -IN
CUT EXISTING SLAB FOR NEW 12" x IS" FTG... OVERPOUR
EXISTING SLAB TO MATCH F.F.E. WITH 3000 PSI CONCRETE
w/ FIBER -MESH, OVER CLEAN COMPACTED, NON ORGANIC FILL OR
UNDISTURBED VIRGIN SOIL. OVER 6 MIL VAPOR BARRIER
SOIL BELOW NEW CONCRETE FOOTING TO BE TERMITE TREATED
(USE A BONDING AGENT FOR OVERPOUR OF CLEAN EXISTING SLAB)
O PROVIDE (2) s5 DOWELS DRILLED 6" MIN. INTO EXISTING FOUNDATION,
SET IN EPDXY, TIE TO (2) 05 RODS IN NEW FOUNDATION (SEE PLAN)
12" x 18" FTG. w/ (2) 05 BARS CONT,
4, FOUNDATIONS ARE DESIGNED ON THE ASSUMPTION OF A MIN.
SOIL $ERRING OF 2000 POUNDS PER SQUARE FOOT
5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS
PRIOR TO COMMENCING WORK.
SHEATHING
SEE WALL DETAIL
2 x 4 - 4' O.C. NAILED
FOR ROOF DETAIL
TO BOTTOM OF
OVERHANG
I I I I
TOP CHORD OF TRUSSES
SEE ELEV,
I I I I
w/ (3) 16D NAILS EACH
II I II
I u u
PLY OF EACH TRUSS
SIDING OVER
(1) ROW 2 x 4 CROSS
VAPOR BARRIER OVER
1tCOX SHEATHING NAILED
BRACING IN CENTER
® 6"O.G, w/ Sol NAILS
I
OF TRUSS NAILED
w/ (2) 160 NAILS
NAIL G.E. TRUSS BOTTOM
CHORD TO LEDGER
I
• 6 O.G. w/ 16d NAILS
I I I I
2 x 4 6 O.G. NAILED
TO TOP OF BOTTOM
CHORD OF TRUSSES
SIMPSON FLAT STRAP s
w/ (3) 16D NAILS EACH
STUD TO TRUSS UPRIGHTS";
PLY OF EACH TRU88
MAX 24" O.C. w/ MIN (4) ]OD
ENGINEERED WOOD
TO STUD 4 TRUSS
MIN 2 x 4 LEDGER TRUSSES a 24" O.C.
ATTACHED TO TOP PLATE
UPRIGHTS UNDER 3' -
TYPICAL
w/ 16d NAILS • 16" O.C.
NO STIFFBAGKS REQUIRED
FRAME WALL
TYPICAL GABLE END DETAIL / FRAME WALL
N.T.S.
DEFACED / DELAMINATED CONCRETE REPAIR
1. REMOVE DELAMINATED OR OTHERWISE UNSOUND CONCRETE, FROM AREA
TO BE PATCHED, SAW CUT AS NECESSARY TO PREPARE AFFECTED AREA.
2, DO NOT CUT REINFORCING STEEL, IF REINFORCING STEEL IS REVEALED
REMOVAL SHALL CONTINUE UNTIL 4" OF REINFORCING STEEL IS REVEALED.
3, REMOVE CONCRETE AROUND REINFORCING STEEL APPROX. I" AROUND
TO ALLOW NEW CONCRETE TO SURROUND REINFORCING STEEL.
4, COAT REINFORCING STEEL WITH SIKA ARMATEC 110 OR EQUAL,
5, EXISTING CONCRETE SHOULD BE PREPARED W/ A BONDING AGENT FOR PATCH.
6. POUR BACK REPAIR AREA WITH A CONCRETE MIX WITH A MIN F-C a 4000 PSI.
MIX SHOULD INCLUDE A CORROSION INHIBITOR ADMIXTURE.
1. A FORM MAY BE UAED TO ALLOW FOR A PROPER EDGE 4 PROPER DRYING
IN PLACE OF PATOH-
PORCH BEAM
----
I ----- I
•12 NAILS •
1 II
12" O.C. MAX. ;
4 foil FROM EA. END
AI
11
I1
I II
2 x 4 SPF STUDS
•` Ifo" O.G.
FRAME WALL
1 II
II
1 I
1 II
1 ,I
1, 14
I II'
I iI
II
I I1
I 11
1 II
EXISTING
FRAME WALL
� l
I
� II
I ,I
SLAB - FOOTING
NEW FRAME WALL TO OLD FRAME WALL
ATTACHMENT DETAIL
NTS
5IMP50N SP (X)
• EACH STUD
• 16" O.G. MAX\
SIMPSON
SP (X)
0 EACH
STUD
I
I
I
y�l
I
1
DOUBLE 2 x 10 HF
OR BETTER HEADER
w 1,!z" CDX PLYWOOD
FLITCH NAILED w/ I&D
12" O,C. 2 ROWS
META 18 FLATSTRAP w/
- (14) IOD NAILS IN EACH
STUD TO HEADER
2X JACKS FOR HEADER
(1) JACK FOR SPANS 5011 OR LESS
(2) JACKS FOR SPANS 5-011 TO 8' 0"
(3) JACK FOR SPANS WO11 TO 12' 0"
2X PT BOTTOM PLATE
u1/ SIMPSON SP (X)
STUD 4 JACK TOP 4 BOTTOM
TYPICAL BRCS WALL HEADER
NOT To SCALE
GENERAL NOTES
I. CONSTRUCTION SHALL FOLLOW "FBC 2011 6TH EDITION"
AS ADOPTED BY THE AREA IN WHICH THE BUILDING 18 TO BE
CONSTRUCTED WITH ALL APPLICABLE AMENDMENTS.
2• TWE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ETC. SHALL VERIFY
ALL DIMENSIONS, CONDITIONS AT JOBSITE, PLANS, SPECIFICATIONS, ETC.
3. ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE
PRECEDENCE OVER SCALED DIMENSIONS.
4. STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE
ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES.
STRUCTURAL NOTES
I. DESIGN LOADS IN ACCORDANCE WITH FBC
2, SOIL BEARING CAPACITY: 25W PSF
3, ALL STRUCTURAL CONCRETE SHALL HAVE A MINIMUM
COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS.
4. SLAB/FOOTINGS TO BE CONCRETE WITH A MINIMUM 3000
PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLANS
FOR SIZE AND STEEL REQUIREMENTS.
5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTINGS: 3" BEAMS: 1 16" SUSPENDED SLABS: I"
6, ALL LUMBER IN CONTACT. WITH CONCRETE - OR
MASONRY WILL BE PRESSURE TREATED.
7. ALL STANDARD LUMBER SHALL BE SPF 03, HEM FUR 03 OF
STUD GRADE WITH A MINIMUM FB - 1200 PSI OR BETTER
S. SPLITTING OR CRACKING OF STRUCTURAL COMPONENTS
DUE TO INSTALLATION OF HARDWARE IS NOT PERMITTED.
9. UNLESS OTHERWISE NOTED, THE INSTALLATION OF
SPECIFIED HARDWARE SHALL CONFORM TO THE
MANUFACTURERS INSTRUCTIONS AND STANDARD PRACTICE.
10. BEARING POINTS OF RAFTERS SHALL HAVE EQUIVALENT
VERTICAL STUDS IN A NUMBER EQUAL TO THE NUMBER OF
PLIES OF THE BEARING MEMBER WHEN THE BEARING
MEMBER IS 2 OR MORE PLIES UNLESS NOTED.
11. ROOF SHEATHING TO BE NAILED WITH 8D RING SHANK
GALV. NAILS OR EQUAL 4" O.C. EDGES AND 6" O.C. ON FIELD
12. UNLESS OTHERWISE NOTED FOR EXTERIOR -WALLS,
EXTERIOR PLYWOOD SHEATHING AND INTERIOR DRYWALL
18 TO BE NAILED WITH 6D RING SHANK OR BETTER NAILS 6" O.C.
EDGES AND 811 O.C. ON FIELD, OR SCREWED WITH DRYWALL
SCREWS 119 INCHES LONG AND 0.131 INCHES DIAMETER
13. EXTERIOR CEILINGS - HIGH RIB LATHE 4 CEMENTATIOUS FINISH OR
EXTERIOR DRYWALL OR VINYL/ALUM SOFFIT
011114. THE FLAME SPREAD AND SMOKE INDEX OF THE WALL AND
CEILING FINISHES ARE IN ACCORDANCE WITH 302.9.1 AND 302.9.2
OF THE FBC 201-1 6TH EDITION:
THE FLAME SPREAD - 200 AND THE SMOKE INDEX - 450
15. THE INSULATION FLAME SPREAD AND SMOKE INDEX ARE IN
ACCORDANCE WITH 302.10.1 AND 302.10.2 OF THE FBC 2011 6TH ED:
THE FLAME SPREAD - 25 AND THE SMOKE INDEX - 450
16, THE WEATHERING, TERMITE AREA AND DECAY AREA IN ACCORDANCE
WITH TABLE 301.2(U OF THE FBC 2011 6TH EDITION:
THE WEATHERING - NEGLIGIBLE AND THE TERMITE AREA - VERY HEAVY
1 I• THE BACKER BOARD BEING USED BEHIND TILE IN SHOWER 4 TUB AREAS
IS IN ACCORDANCE WITH 102,4 OF THE FBC 2011 6TH EDITION:
14'-0"
RAIM MIOTM PO C1 SLAB
TO ME T F I .E.
WE F.UVC=TIN NOTE WALL OEGPION
ALL PLU` M NG TO FOLLOW
REQUIREMENTS OF THE FBC 201-7
6TH ED
311 211 311
VTR VTR vTR
1
-1
r 211
r- r r
TUB
3" 2
its"
KITCHEN
211
LAv
W.G. VENT
L. TUB
Ut4DER
211
CAB.
SHOWER
LAV
211
311
WASHER
311
2�
w,c.
311
211
311
11
4
PLUMBING
C.O.
4
RISER
DIAGRAM
TO SEPTIC
OR SEWER
SCOPE OF PROJECT
THIS PROJECT IS TO REPLACE ! OR
REFA/R THE DAMAGE ASSOCIATED
531-0:1
25
FLOOR FLAN
SCALE: 1/4" - 1'-0"
F�a"IE UJ=:L
GENERAL ELECTRICAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE
2014 NATIONAL ELECTRIC CODE & SHALL CONFORM WITH THE
FLORIDA BUILDING CODE & ALL LOCAL CODES.
2. FAMILY ROOMS, BEDROOMS, LIVING ROOMS, SUNROOMS,
DENS, HALLWAYS, CLOSETS, OR SIMILAR ROOMS OR AREAS
TO HAVE ARC FAULT PROTECTION PER 2014 NEC SECTION 210.12 (B)
3. ALL 15 & 20 AMP RECEPTACLES IN KITCHENS, FAMILY ROOMS,
BEDROOMS, LIVING ROOMS, SUNROOMS, HALLWAYS, CLOSETS,
OR SIMILAR ROOMS OR AREAS TO BE OF THE TAMPER RESISTANT
TYPE PROTECTION PER 2014 NEC SECTION 406.11
4. GFI OUTLETS ARE TO BE INSTALLED IN THE KITCHEN, BATHROOM,
GARAGE, & OUTSIDE LOCATIONS AS NOTED (GFI) ON PLANS.
5. FINAL PLACEMENT OF ALL ELECTRICAL COMPONENTS TO BE
DETERMINED BY THE ELECTRICIAN OF RECORD IN ACCORDANCE
WITH THE 2014 NATIONAL ELECTRIC CODE & SHALL CONFORM
WITH THE FLORIDA BUILDING CODE & ALL LOCAL CODES.
6. ENGINEER OF RECORD NOT RESPONSIBLE FOR ELECTRICAL PLANS
EGRESS
SH 25
ELECTRICAL LEGEND
ELECTRICAL
SYMBOL
CARBON MONOXIDE -
SMOKE DETECTOR COMBO
cgA
DOOR CHIME
EXHAUST FAN LIGHT
FAN LIGHT COMBO
�l
-C
L
FLUORESCENT 4' LIGHT
GARAGE DOOR OPENER
GFI OUTLET
GFI OUTLET • 42
�{
GFI 42"
GFI WATER PROOF
&P1-GFI
LIGHT
(1
YYY�
OUTLET
PANEL 200 AMP
PANEL
200 AMP
PULL CORD LIGHT
PULL
CORD
PUSH BUTTON
0
SWITCH
W1714 RECENT FIRE DAMAGE,
PRODUCT APPROVAL SUBMITTAL AFFIDAVIT
THE ROOF /S BEING REPLACED WITH
A NEW TRUM SYSTEM $ 5V METAL ROOF.
ALL DOORS t WIACOU16 ARE BEING REPLACED.
SOME INTERIOR / EXTERIOR MODIFICATIONS/FIL
R FIRE RESTORATION
SALERAT ION FOR
THE FOLLOWING PRODUCTS WILL BE 8401 ESTOROAD
INSTALLED IN THE STRUCTURE LOCATED AT: FT, PIERCE, O 34951
PRODUCT
PROD. DESIGN
MANUF.
MODEL 0
PRODUCT
RENOVATIONS ARE BEING DONE AT THE SAME
TIME AS NEEDED... ( ELECTRICAL, PLUMBING,
NEW WAL _ FRAMING, INSULATION, ETC ETC.)
PRESSURES
APPROVAL
ALL WORK /S TO BE DONE PER THE
FBC 2017 6T,4 EDITION PER THESE PLANS.
EXTERIOR
SWING DOOR
+/-61 PSF
THERMA TRU
SMOOTH STAR
IMPACT
FL 5891.2
AREA SQUARE FEET
MAIN LIVING 1486
ADDITIONAL LIVING SPACE Be
TOTAL LIVING SPACE 1545
ENTRY PORCH 158
GARAGE 261
TOTAL SQUARE
19'10
SLIDING DOOR
+/-50 PSF
CUSTOM WINDOW
8800 PVC
FL 20838.1
SYSTEMS
IMPACT
LEVEL II
SH WINDOW
+6T.5 / --15 PSF
CUSTOM WINDOW
8100 PVC
FL 5823,1
SYSTEMS
SINGLE HUNG IMPACT
ALTERATION
GARAGE DOOR
+41.1 / -46.4 PSF
HAGS DOOR
PAN SERIES
FL 16660.11
COMPANY
GARAGE DOOR
ROOFING
86 PSF
EXTREME METAL
FABRICATORS LLC
5V CRIMP
26 GA. METAL
FL 11022.1
A/C BY OTHERS
I HAVE REVIEWED THE ABOVE 18v7 -o-7qD
COMPONENTS AND CLADDING, BU�LDINQ COUNTY t ONCPALlD FAsTlNEAS
AND HAVE APPROVED THEIR OR ATTACHM
NOTICE:
It Is Important that the Client and Contractor examine the
drawings and documentation In detall. It shall be the final
responsibility of the Contractor to review and double check
the plans for accuracy and compliance with regulatory
agencies. It Is customary and ordinary not to include details
well within this knowledge of licensed Contractor. If
necessary, further clarification of these plans should be
achieved berore signing the construction contract and
obtaining a building permit, otherwise the Contractor assumes
responsibility for the construction In questton. Methods of
construction shalt be determined by the Contractor.
•• RELOCATION OF ANY UTILITIES ARE NOT NOTED ON THESE PLANS
REVIEWFOR COMPLBI O C ARE THE RESPONSIBILR OF THE USE IN THE STRUCTURE TO REVIEWSqq BY
PROVIDE ADEQUATE RESISTANCE DATE R12 ( CONTRACTOR OF RECORD
TO THE WIND LOADS AND FORCES PLANS AND PER T
MUST BE KEPT ON J B OR _
SPECIFIED BY THE CURRENT CODE NO INSPECTION WILL E MADE
PROVISIONS, a�Y
AS SIGNED, SEALED 4 DATED HERE. THESE PLANS AND ALL PROP SED wv,,. fit. W >1syrRi ARE SUBJECT TO ANY CORRECTIONS
REQUIRED WY FILD ItAraCTORS 71 TAT "-
PERM IT w180�-0�40 UAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICAME CODES,
RECEIVED
SEP 0 4 2018
ST. Lucie County, Permitting
O
�
� �
W
00
A00
ON
00
O M
O
A4 Q cp
M N
w¢ oo
C7 U00
° '3a�
OoEro
�
WaF'p"
wH a
IA
0 Copyright2018
ROBERSON
DESIGN GROUP
All rights reserved.
REVISION DATI
8/21/18
JOB » 18100
DATE : I/S/18
DRAWN BY SR
SHEET
1of2
4 tip, T
Top 3
of
Plate
REAR ELEVATION
SCALE: 1/4" - P�4"
5V METAL ROOFING
� -ice � � � L' k"I
I __ Lt ----------
FRONT ELEVATION
LEFT ELEVATION
SCALE: 1/4" - I'-0"
R302.5 DWELLING -GARAGE OPENING AND PENETRATION PROTECTION.
Openings And Penetrations Through The Walls Or Callings Separating The Dwelling From
The Garage Shall Be In Accordance With Sections R302.5.1 Through R302.5.3,
R302.5.1 OPENING PROTECTION.
Openings From A Private Garage Directly Into A Room Used For Sleeping Purposes Shall Not
Be Permitted. Other Openings Betwsen The Garage And Residence Shall Be Equipped With
Solid Wood Doors Not Less Than 13/8 Inches (35 Mm) In Thickness,
Solid Or Honeycomb-Cors Steel Doors Not Less Than 13/8 Inches (35 Mm) Thick, Or 20-Minute Fire -Rated Doors.
RBOZ5.2 DUCT PENETRATION.
Ducts In The Garage And Ducts Penetrating The Walls Or Ceilings Separating The Dwelling From The Garage
Shall Be Constructed Of A Minimum No. 26 Gage (0.48 Mm) Sheet Steel, 1 Inch (25.4 Mm) Minimum Rigid Nonmetallic
Class O Or Class I Duct Board, Or Other Approved Material And Shall Not Have Openings Into The Garage.
R302.5.3 OTHER PENETRATIONS.
Penetrations Through The Separation Required In Section R302.6 Shall Be Protected As Required By Section R302.11, Item 4.
R302.6 DWELLING -GARAGE FiRE SEPARATION.
The Garage Shall Be Separated As Required By Table R302.6. Openings In Garage Walls Shall Comply With Section R302.5.
Attachment Of Gypsum Board Shall Comply With Table R102.3.5, The Wall Separation Provisions Of Table R302.6
Shall Not Apply To Garage Walls That Are Perpendicular To The Adjacent Dwelling Unitwall.
TABLE R302.6 DWELLING -GARAGE SEPARATION
SEPARATION
MATERIAL
From The Residence And Attics
Not Less Than 1/2-inch Gypsum Board Or Equivalent
Iled To The Garage Side
From Habitable Rooms Above The Garage
Not Less Than 5/8-Inch Type X Gypsum Board Or Equivalent
Structure(S) Supporting Floor/Gelling Assemblies
Used For Separation Required By This Section
Not Less Than 1/2-Inch Gypsum Board Or Equivalent
Garages Located Lose Than 3 Feet
From A Dwelling Unit On The Same Lot
Not Lees Than 1/2-Inch Gypsum Board Or Equivalent Applied
To The Interior Side Of Exterior Walls That Are Within This Area
Q
O
ON
a,
M M
M �
,
y0
C.7
W �
U O�0
o03a�
v'O�rF,)a
F
® Copyright 2018
ROBERSON
DESIGN GROUP
All rights reserved.
REVISION DATE
8/21/18
JOB 8 18100
DATE : i/S/18
DRAWN BY SR
SHEET
2 of 2