Loading...
HomeMy WebLinkAboutREVISION 12-4-18NNN OFFICE USE ONLYt ) sc Y eD {� oy DATE FILED: / 0 C' , cie c� "T PERMIT # a 7 / REVISION FEE: _ 0 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.585 �I (772)482.1553 APPLICATION FOR BUILDING PERMIT E Slolb� PROJECT INFORMATION LOCATION/SITEADDRESS: (/ l(� U l DETAILED DESCRIPTION OF PROJECT REVISIONS: tV411 � vvev� !"liswfi Oti �a,ro� el04 Dd rv/aC/07as'�< 0- CONTRACTOR INFORMATION: STATE of FL REG./Cl BUSINESS NAME: QUALIFIERS NAME: ADDRESS: a CITY: PHONE (DAYTIME): OWNER/BUILDER INFORMATION: NAME: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: CITY: _ STATE: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130117 .-fn,ik-P-/Z, ST. LUCIE CO CERT. #: FAX: FAX: raA: ZIP: ZIP: ZIP: DEC -4 2018 7 FILE COPY Permitting Department St. Lucie County, FL As BASIC WIND SPEED 160 MPH 3-SEC. GUST RISK FACTOR - II BUILDING CATEGORY ENCLOSED EXPOSURE CATEGORY B INTERNAL PRESSURE COEFF, 0,18 WIND DESIGN PRESSURES - GARAGE DOOR -34.1 / +30 PSF ALL OTHER OPENINGS +36 / -41 PSF FOUNDATION 4 SLAB NOTES FOR REAR PORCH FRAME -IN CUT EXISTING SLAB FOR NEW 12" x IS" FTG.,, OVERPOUR EXISTING SLAB TO MATCH F.F.E. WITH 3000 PSI CONCRETEI w/ FIBER -MESH, OVER CLEAN COMPACTED, NON ORGANIC FILL OR UNDISTURBED VIRGIN SOIL. OVER 6 MIL VAPOR BARRIER SOIL BELOW NEW CONCRETE FOOTING TO BE TERMITE TREATED (USE A BONDING AGENT FOR OVERPOUR OF GLEAN EXISTING SLAB) O PROVIDE (2) 05 DOWELS DRILLED 6" MIN. INTO EXISTING FOUNDATION, SET IN EPDXY, TIE TO (2) 05 RODS IN NEW FOUNDATION (SEE PLAN) (� 12" x 18" FTG. w/ (2) 1*5 BARS CONT. 4, FOUNDATIONS ARE DESIGNED ON THE ASSUMPTION OF A MIN, SOIL BEARING OF 2000 POUNDS PER SQUARE FOOT 5, CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO COMMENCING WORK_ SHEATHING SEE WALL DETAIL FOR ROOF DETAIL 2 x 4 - 4' O,C, NAILED ERHANG I I I I TO BOTTOM OF OVEE IN I I I I TOP CHORD OF TRUSSES S I I w/ (3) 16D NAILS EACH SIDING OVER I PLY OF EACH TRUSS VAPOR BARRIER OVER (U ROW 2 x 4 CROSS 15" COX SHEATHING NAILED BRACING IN CENTER • 6"O.C, w/ 8d NAILS - I OF TRUSS NAILED w/ (2) 160 NAILS NAIL G.E. TRUSS BOTTOM I I CHORD TO LEDGER I I I I I e 6" O.C. w/ 16d NAILS i t I I 2 x 4 6' D.G. NAILED \ _ I TO TOP OF BOTTOM CHORD OF TRUSSES SIMPSON FLAT STRAP e �' STUD TO TRUSS UPRIGHTS— w/ 16D NAILS EACH MAX 24" O.G, w/ MIN (4) 100 ENGINEERED WOOD PLYY OF EACH TRUSS TO STUD t TRUSS MIN 2 x 4 LEDGER TRUSSES a 24" O.C. ATTACHED TO TOP =LATE UPRIGHTS UNDER 3'. TYPICAL — w/ I6d NAILS s 16" C.G. NO STIFFBACKS REQUIRED FRAME WALL TYPICAL GABLE END DETAIL / FRAME WALL N.T.S. DEFACED / DELAMINATE:D CONCRETE REPAIR I, REMOVE DELAMINATED OR OTHERWISE WSOUND CONCRETE, FROM AREA TO BE PATCHED, SAW CUT AS NECESSARY TO PREPARE AFFECTED AREA. 2, DO NOT CUT REINFORCING STEEL, IF REINFORCING STEEL IS REVEALED REMOVAL SHALL CONTINUE UNTIL 4" of REINFORCING STEEL IS REVEALED. 3, REMOVE CONCRETE AROUND REINFORCING STEEL APPROX. I" AROUND TO ALLOW NEW CONCRETE TO SURROUND REINFORCING STEEL, 4, COAT REINFORCING STEEL WITH SIKA ARMATEC 110 OR EQUAL. 5, EXISTING CONCRETE SHOULD BE PREPARED W/ A BONDING AGENT FOR PATCH. 6, POUR BACK REPAIIQ AREA WITH A CONCRETE MIX WITH A MIN F-C = 4000 PSI. MIX SHOULD INCLUDE A CORROSION IN4131TOR ADMIXTURE. -1, A FORM MAY BE USIED TO ALLOW FOR A PROPER EDGE 4 PROPER DRYING IN PLACE OF PATCH, PORCH BEAM i. -- - -�---. - r •12 NAILS G 12" O.C, MAX, 4 6" FROM EA. END I rr I, I II 2 x 4 SPF STUDS I !I o I&" O.C. I Ir I iI FRAME WALL � Ir I Vr I I rl I 4: � I r I� r ,r II I A Ir I 11 � I r .rl EXISTING I FRAME WALL r I r I II I1\ \ I SLAB - FOOTING NEW FRAME WALL TO OLD FRAME WALL ATTACHMENT DETAIL NTS SIMPSON SP DO e EAC44 STUD s I6" O,G. MAX SIMPSON SP (X) e EACH STUD r I I I I I I I DOUBLE 2 x io HF OR BETTER HEADER 7`-- w 16" CDX PLYWOOD FLITCH NAILED w/ 16D 12" O,C, 2 ROWS META 18 FLATSTRAP w/ — (14) 100 NAILS IN EACH STUD TO HEADER 2X JACKS FOR HEADER (U JACK FOR SPANS 5'O" OR LESS (2) JACKS FOR SPANS 5'0" TO 8' O" (3) JACK FOR SPANS 8'O" TO 12'0" 2X PT BOTTOM PLATE w/ SIMPSON SP (X) A STUD 4 JACK TOP 4 BOTTOM TYPICAL BRCS WALL HEADER NOT TO SCALE GENERAL NOTES 1, CONSTRUCTION SHALL FOLLOW "FBC 2011 6TH EDITION" AS ADOPTED BY THE AREA IN WHICH THE BUILDING IS TO BE CONSTRUCTED WITH ALL APPLICABLE AMENDMENTS, 2, THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ETC. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOBSITE, PLANS, SPECIFICATIONS, ETC. 3, ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS, 4. STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES, STRUCTURAL NOTES I. DESIGN LOADS IN ACCORDANCE WITH FBC 2, SOIL BEARING CAPACITY: 2500 PSF 3. ALL STRUCTURAL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, 4, SLAB/FOOTINGS TO BE CONCRETE WITH A MINIMUM 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLANS FOR SIZE AND STEEL REQUIREMENTS. 5, MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" BEAMS: 1 It" SUSPENDED SLABS: 1" 6, ALL LUMBER IN CONTACT, WITH CONCRETE - OR MASONRY WILL BE PRESSURE TREATED. 1. ALL STANDARD LUMBER SHALL BE SPF 03, HEM FUR 03 OF STUD GRADE WITH A MINIMUM FB - 1200 PSI OR BETTER 6. SPLITTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALLATION OF HARDWARE IS NOT PERMITTED. 9, UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURERS INSTRUCTIONS AND STANDARD PRACTICE. 10. BEARING POINTS OF RAFTERS SHALL HAVE EQUIVALENT VERTICAL STUDS IN A NUMBER EQUAL TO THE NUMBER OF PLIES OF THE BEARING MEMBER WHEN THE BEARING MEMBER IS 2 OR MORE PLIES UNLESS NOTED. 11, ROOF SHEATHING TO BE NAILED WITH SD RING SHANK GALV. NAILS OR EQUAL 4" D.G. EDGES AND 6" O.G. ON FIELD 12. UNLESS OTHERWISE NOTED FOR EXTERIOR -WALLS, EXTERIOR PLYWOOD SHEATHING AND INTERIOR DRYWALL IS TO BE NAILED WITH 8D RING SHANK OR BETTER NAILS 6" O.C. EDGES AND 8" O,G. ON FIELD, OR SCREWED WITH DRYWALL SCREWS Ila INCHES LONG AND 0.131 INCHES DIAMETER 13. EXTERIOR CEILINGS - HIGH RIB LATHE 4 CEMENTATIOUS FINISH OR EXTERIOR DRYWALL OR VINYL/ALUM SOFFIT 14. THE FLAME SPREAD AND SMOKE INDEX OF THE WALL AND CEILING FINISHES ARE IN ACCORDANCE WITH 302.9.1 AND 302.9.2 OF THE FBC 2011 6TH EDITION: THE FLAME SPREAD - 200 AND THE SMOKE INDEX - 490 15. THE INSULATION FLAME SPREAD AND SMOKE INDEX ARE IN ACCORDANCE WITH 302.10.1 AND 302,10,2 OF THE FBC 2011 6TH ED: THE FLAME SPREAD - 25 AND THE SMOKE INDEX . 450 16. THE WEATHERING, TERMITE AREA AND DECAY AREA IN ACCORDANCE WITH TABLE 301.20U OF THE FBC 2011 6TH EDITION: THE WEATHERING - NEGLIGIBLE AND THE TERMITE AREA - VERY HEAVY Il. THE BACKER BOARD BEING USED BEHIND TILE IN SHOWER 4 TUB AREAS 18 IN ACCORDANCE WITH 102,4 OF THE FBC 2011 6TH EDITION: 53'-0" 111 �I I a'h al ICIOR 111 1 �S MASTER BEDROOM Q II�--- WIC r FJL \ k GC A \ SD SD - 11 GFI • 42" 9010 GARAGE DOOR 141-0" ALL PLUMBING TO FOLLOW REQUIREMENTS OF THE FBC 2011 6TH ED vTR VTR VTR 1 r 2„ 1 r rua 2" 3" 1it 11 ,L Al KITCHEN C. 2" LAv VENT L. TUB UNDER 2" ll,611 CAB SHOWER LAV � 2 3„ WASHER 311 2- W.G. 3" 211 31 411 PLUMBING 4" C.O. RISER DIAGRAM TO SEPTIC OR SEWER SCOPE OF PROJECT THIS PROAECT /S TO REPLACE t OR REPAIR THE DAMAGE ASSOCIATED SH 25 GREAT ROOM 251-011 1 \r F ENTRY / PORCH 25'-011 53'-011 FLOOR PLAN SCALE: 1/4" - 1'-0" CCq SD SW 25 EGRESS SH 25 13'-4" BEDROOM •2 5068 By WIC 4 �I-011 CLOSET Q -' 60" BIFOLD HALL 'n m 2860 c�a SD DEC - 4 2018 Permitting Department 1 r-minty. FL GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE & SHALL CONFORM WITH THE FLORIDA BUILDING CODE & ALL LOCAL CODES. 2. FAMILY ROOMS, BEDROOMS, LIVING ROOMS, SUNROOMS, DENS, HALLWAYS, CLOSETS, OR SIMILAR ROOMS OR AREAS TO HAVE ARC FAULT PROTECTION PER 2014 NEC SECTION 210.12 (B) 3. ALL 15 & 20 AMP RECEPTACLES IN KITCHENS, FAMILY ROOMS, BEDROOMS, LIVING ROOMS, SUNROOMS, HALLWAYS, CLOSETS, OR SIMILAR ROOMS OR AREAS TO BE OF THE TAMPER RESISTANT TYPE PROTECTION PER 2014 NEC SECTION 406.11 4. GFI OUTLETS ARE TO BE INSTALLED IN THE KITCHEN, BATHROOM, GARAGE, & OUTSIDE LOCATIONS AS NOTED (GFI) ON PLANS. 5. FINAL PLACEMENT OF ALL ELECTRICAL COMPONENTS TO BE DETERMINED BY THE ELECTRICIAN OF RECORD IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE & SHALL CONFORM WITH THE FLORIDA BUILDING CODE & ALL LOCAL CODES. 6. ENGINEER OF RECORD NOT RESPONSIBLE FOR ELECTRICAL PLANS 11 HOME OFFICE ram -e,-)4e ST. LUCIE CO BUILDING I REVI E FOR CO PL E REVIEWED P`/ DATE It I I PUNS AND P RMIT MUST BE KEPT O J03 6R NO INSPECT ION WI L BE MADE TH SE PLAIDS AM ALL PROPOSED WORKi AR SUILECTTO ANY CORRECTIONS RE OIREORYFIUUPECTORS THAT MA I 6E NECFJARY IN ORDER TO C PLYVITHALLAPPLIC CO0E3, N - CO CFALED FASTENER$ OR ATTACH, ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD 140W:M BATHDO Q 13'-4" SH 25 EGRESS 14'-0" ELEC-TRICAL LEGEND ELEC'IRIcA SYMBOL CARBON MONOXIDE - SMOKE DEFECTOR COMBO ce ab DOOR CHIME 20 EXHAUST FAN LIGHT FAN LIGHT COMBO{ } L FLUORESCENT 4' LIGHT GARAGE DOOR OPENER GFI OUTLET uu( GPI OUTLET • 42 GFr • 42" GPI WATER PROOF (flyVRGFI LIGHT { } OUTLET PANEL 200 AMP PANEL 2000 AMP PULL CORD LIGHT - }ftu- TCORD PUSH BUTTON Q SWITCH =14 RECENT FIREOAMAGE PRODUCT APPROVAL SUBMITTAL AFFIDAVIT THE ROOF /S BEING REPLACED W1774 A N4-W TRUSS SrSTEM r 5v METAL ROOF, FIRE RESTORATION FOR THE FOLLOWING PRODUCTS WILL BE IRE RESTSALEORATION ,ALL DOORS t /UINOOWSI ,ARE BEING REPLACED INSTALLED IN THE STRUCTURE LOCATED AT: O ROAD SOME INTER/OR / EXTERIOR MOD/F/C,4T/ON8/ FT, PIERCE, 34951 PROD, DESIGN PRODUCT RENOVATIONS .ARE BEING DONE AT T,4E SAME TIME AS NEEDED-., t FJ_ECTR/CAA_, PLUMBING, PRODUCT MANUF. MODEL " PRESSURES APPROVAL NEW/ WALL M4M/NCR INSULAT/ON, ETC ETC> ALL WORK /S TO BE DONE PER THE EXTERIOR SMOOTH STAR FBC 2017 6TH EDITION PER THESE PLANS, SWING DOOR +/-&I PSF THERMA TRU IMPACT FL 5891.2 AREA SQUARE FEET MAIN LIVING 1486 ADDITIONAL LIVING SPACE Be TOTAL LIVING SPACE 1545 ENTRY PORCH 150 GARAGE---_„�. 261 TOTAL SQUARE FEET 1910 SLIDING DOOR +/-50 P8F CUSTOM WINDOW SYSTEMS 8800 PVC IMPACT FL 20838.1 LEVEL II LEVEL SH WINDOW +61 5 / -15 PSp CUSTOM WINDOW SYSTEMS 8100 PVC SINGLE HUNG IMPACT FL ALTERATION GARAGE DOOR +41,1 / -46.4 PSF HASS DOOR COMPANY PAN SERIES GARAGE DOOR FL 16660.11 ROOFING -86 PSF EXTRE ME METAL LLC 5V CRIMPFABRICATORS 26 GA, METAL FL 11022,1 I HAVE REVIEWED THE ABOVE COMPONENTS AND CLADDING, SCANNED AND HAVE APPROVED THEIR " BY A/C BY OTHERS NOTICE: It is important that the Client and Contractor examine the drawings and documentation In detail, It shalt be the final responwbllity of the Contractor to review and double check the plane for acourecy and compliance with regulatory agencies. It Is COetomary and ordinary not to Include detatle well wtthin the knowledge of licensed Contractor. If necessary, furthef clarification of these plans should be achieved beForLa signing the conetructton contract and obtaining a buttaing permit, otherwise the Contractor assumes responetbtltty for the constructton in question, Methods of construction shall be determined by the Contractor. - RELOCATION OF ANY UTILITIES ARE NOT NOTED ON THESE PLANS USE IN THE STRUCTURE TO i i Lucie County PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES v SPECIFIED BY THE CURRENT CODE PROVISIONS. AS SIGNED, SEALED t DATED HERE... PERMIT •1801-0140 — - RELOCATED LAUNDRY AREA - REVISED MASTER BEDROOM 4 BATH •2 LAYOUTS Py x14 � �z a�' 00 a A 5 z ■z �N❑R ■1:1■ f� 00 o� O O M to m � 1 m a N M 1 yU00 w 0 in C) (~ (1y a a LL Ui Z O O U_ L Q U dJ 1 Uj O � L M LL W�J 0 Copyright 2015 ROBERSON DESIGN GROUP All rights reserved. REVISION DATE I1/26/18 JOB • 18100 DATE : 7/S/18 DRAWN BY SR SHEET of 2_