Loading...
HomeMy WebLinkAboutEVALUATION REPORTW ,,r\ cam, v w aNNED 1239 Jabara Ave. URNER BY North Port, FL 34288 ENGINEERING & as gn*/ G� Ph. 941-380-1574 07 CONSULTING, INC. ����,w(®—FBPE C.O.A. #29779 Evaluation Report 295E COPY September 7, 20175 Product Description: Series 8100 PVC Single Hung, Large Missile Impact, 52" x 96" unit size Oriel configuration at +/-70 PSF Manufacturer: Custom Window Systems, Inc. 1900 SW 44 h Ave, Ocala, FL 34474 1 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6`b Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) . This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 2) Approval drawing CWS-295E, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports NCTL-210-3946-05 and -5A, by National Certified Testing Laboratories, Orlando, FL, TAS testing signed and sealed by Gerard J. Ferrara, with testing performed: TAS 201/202/203-94, ASTM E 1886-05, ASTM E 1996-05/09, and AAMA/WDMA/CSA 101/I.S.2/A440-08 4) Supplemental Calculations to support CWS-295E, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-295E. Limitations of Use: This product: • May be used in O/X Oriel configuration in sizes up to 52" x 96" unit size at +/-70 PSF, with max. glass DLO heights as shown in CWS-295E • Is impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires 7/8" Insulating Glass. consisting of, in the Fixed Lite: 3/16 Ann. or Temp. outboard (Tempered required above 30 ft in HVHZ) — Air — 7/16 Laminated (3/16Ann-.09OSGP- 3/16Ann). In the Sash: 1/8 Ann. or Temp. outboard lite (Tempered required above 30 ft in HVHZ) — Air — 5/16 Laminated (1/8Ann-.090PVB-1/8Ann) • Requires in Sash Kuraray (Dupont) PVB Interlayer per Miami -Dade N.O.A. 16-1117.02t • Requires in Fixed Kuraray (Dupont) SentryGlas Interlayer per Miami -Dade N.O.A. 14-0916.1 It • Requires Quanex (Mikron) white rigid PVC framing per Miami -Dade N.O.A. 17-0206.1 Ot t I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find that they comply with the requirements of the 6th Ed. (2017) Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. Wk Lucas .�. too 58201% =��I� 9/07/2017 Turner - :* Lucas A. Turner, P.E. 2017-09-16 :13 ;. STATE OF : �� FL PE #58201 09:23+20:00 � `�' .�,0 t5 Ft 1 O P`"Qi�`��� SINGLE HUNG ORIEL - LARGE MISSILE IMPACT 97 1/4" MAX. OVERALL FLANGE MAX. B 30 3116" MAX SASH HEIGHT TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS.....1 GLAZING DETAIL.................................2 SECTION VIEWS.................................3 EXTRUSIONS & B.O.M........................4 ANCHOR SCHEDULE & NOTES INSTALLATION DETAILS....................6 53 14' — MAX OVERALL FLANGE WIDTH MAX. UNIT WIDTH 13/16" GLASS DLO A- ---t--- —I— I �13 I I O I I GLASS I B t I 6 X I O 26 7/8" 6 GLASS DLO 4 C C - A — 45 114" — GLASS DLO 48 9116" MAX. SASH WIDTH 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED y�NizWsi;Fs�kg� TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND 1900 SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA, FLORIDA 34474 IN ASTM E 1996 PER THE FBC. WWW.CWS.CC 2. GLAZING OPTIONS: (SEE SHEET 2) 8100 PVC 3. CONFIGURATIONS: "O/X". SINGLE HUNG 4. DESIGN PRESSURE RATING: IMPACT -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES Fa- o w o 0 ASTM E-1300-04e01/09. Z w w -io o ci� ZOZ}Oir�m 5. ANCHORAGE: THE 331/3%STRESS INCREASE HAS NOT BEEN USED LL a w z F- 3: 2 _ IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR Z Z = 2 ¢ 0: w O O DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD O U O F O Cj ¢ = I- K UNF'-ZD-P a)(L ANCHOR CALCULATIONS. p j- Z Co 6. PRODUCT APPROVED FOR IMPACT RESISTANCE. THE IMPACT O- j U r LL M zcnO O LL Z a:Z SWEEP LOCKS ARE INTENDED TO BE LEFT UNLATCHED DURING NORMAL OPERATION OF THIS PRODUCT, BUT MUST BE ENGAGED < ¢O w - ., w 4 � 0 WINDS AND FLYING DEBRIS. H Or Y O O o o PRIOR TO EXPOSURE TO HURRICANE w w (nit._ z"-'w O_jaDl= 22 a0 a a. = 7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT w O I, Co USED AT FIXED MEETING RAIL AND JAMB. m m a w � wa 8. IDES 9. THEGNAT10N XAND O STAND FOR THE FOLLOWING: .p'�. �``�,,S,P CE•ETIS••TG F /'fin' X = OPERABLE SASH, O = FIXED SASH ��J�?.'" •; No 582J1 10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR LOCATION. 11. EXTERNAL WEEP SLOT = 1/4" x 1-1/4" LOCATED 4" FROM BOTH ENDS. � STATE OF 4_ n..A. DESIGN PRESSURE MAX. UNIT SIZE IMPACT RATING RATING 52" x 96" +/- 70 PSF LARGE MISSILE IMPACT Lucas Turner 2017-09-25 15:08+20:00 9/25/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVF� NORTH PORT, FL 3g PH. 941-380-157(, GENERAL NOTES AND ELEVATIONS ADE 1 09/12/08 CWS-295 E ALE: SHEET 1:20 1 OF 6 ' 48 FIXED LITE 718" OVERALL 7/8" OVERALL 3116" ANNEALED OR TEMPERED 1/8" ANNEALED OR TEMPERED 1/4" AIRSPACE 7/16" AIRSPACE 7/16" LAMINATED 5/16" LAMINATED 3116" ANNEALED 1/8" ANNEALED ,090" SENTRY GLASS IONOPLAST INTERLAYER .090" DUPONT PVB INTERLAYER 3/16' ANNEALED 11W ANNEALED QUANEX DURASEAL IG SPACER QUANEX DURASEAL IG SPACER SIKAFLEX 552 OR I/e PURFECTGLAZE"H" SIKAFLEX 552 OR PURFECT GLAZE'H" 1/2" GLASS BITE • ^ Ilj� Rjl 1/2" GLASS BITE WINDOW SYSTEMS IS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.cws.cc 8100 PVC SINGLE HUNG IMPACT i 3 ¢Z� P- Dw0 WHO z wJ0 w ZOZ w—Zf- O ;z W3>-OO=3:m u. Fw ZFR:m= Z Z=S<ww00 O OH-O Q=Fw U UyFZa-F.cod Z ZOV,1 co —jU— zowz } Q-'WoxO W 0cl w(DO wU,I� E2 z�a 0 co =~w wi'iWo a qo � z Z SASH LITE 9/25/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE-, NORTH PORT, FL 34� PH. 941-380-1574? GLAZING DETAILS ADE 09/12/08 DWG 0: REV.: SETTING BLOCKS PER FBC 2411.3.3.1 CWS-295 E SCALE: SHEET 1:1 20176 INTERIOR WIN®ObV SYSTEP95 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWWCWS.Cc 45 3 7 53 12 38 13 35 32 4 45 0 8100 PVC ® SINGLE HUNG D D IMPACT 0 as o a - ¢z0 woo 1 nn n P Z w owo w J O W f- w zoz_ ��?�- 0� 14 O F--;Fcw�ZO3i�2 33 1 Z z2�¢D'woo 3 15 54 65 66 63 19 4 O O f- 0 6 U F- w SECTION B-B o z z` - Z �- 0 co o(D :) U_ NOTE: LEFT SIDE SHOWS FIXED SECTION VIEW, } ¢ 3 LL w p = LLo v w RIGHT SIDE SHOWS SASH SECTION VIEW. o i- F z 14 w_ O0ofCD0wcnfiy.. 40 D: a0 Zcow 0-ImF- dS 31 39 wF=-O >- (a X�'nw a 7 6 VIO,RuEVY "� 34 INTERIOR ,,,0 v .y.,6EIYs*-. L'� 9 '�.� 4J. cni �A 48 N. 58201 : 62 QS STATE OF J'41 4 0 A 10:0��`� 16 53 10 65 1 66 62 n Z� 34 q 9/25/2017 1a � 3 LUCAS A. TURNER, P.E. O 6 2 FL PE # 58201 2 JABARA AVE' 30 NORTHRTH PORT, 34 0 3 PH.941-380-1-1574 45 �o 0 SHEET DESCRIPTION: SECTION A -A SECTION C-C SECTION VIEWS ALTERNATE IMPACT HOOK DRAWN BY: DATE AIDE 09/12/08 DWG9: REV.: NOTE: ITEMS NOT SHOWN FOR CLARITY: CWS-295 E 20, 25-26, 31, 36-37, 44, 51-52, 55-56, 64, 67-68 SCALE: SHEET 1:2 30F6 Main Fr R Vendor 27 1 P-3783 ILock, Impact, PVC Interlock 28 134069 Keeper, Impact, PVC Interlock Zamac 30 P3215 Weep Coeerw/ Flap Gaer Plastic 31 S-6077 HD Fixed Meeting Rail Cover Mikron Vinyl 32 P3429 Wstp., 0.270 x .187 back FinSeal, Gray Ultrafab 33 P3429 Wstp., 0.270 x .187 back FinSeal, Gray Ultrafab 34 P3429 Wstp., 0.270 x .187 back FinSeal, Gray Ultrafab 35 P3429 Wstp., 0.270 x .187 back FinSeal, Gray Ultrafab 36 P3429 Wstp., 0.270 x .187 back FinSeal, Gray Ultrafab 37 P4638 #8 x 2-1/2 PH Mod. Truss, Type A, TEK 2 Fastenal Steel 38 P3768 #8 x 0.625 Ph PH SMS Hub City Steel 39 P-4051 W #8 x 1.250 Ph FH TEK, Wht. Hub City Steel 40 P4264W #8 x 314 FH PH w/#6 Head, TEK, Wht. Hub City Steel 44 P-3342 Seam Sealer, SM-5504 Schnee 45 P-3752 Cap Plug, 1/2" Hole M&M Nylon 47 P-3438 Sikaflex 552 or Purfect Glaze "H" Sika/Henkel 48 P3352 ISet. Blk., 85 Dur., 1/8" x 5/8" x 2" Lg. F. Lowe Rubber 51 P3881 Temporary Lbl. (NFRC/DP) 52 I P3613 I CWS Lbl. (loco) Pro Label 68 x x 21 PVC FRAME FLANGE H-6031 ilia" 5/16" 19 1J16" PVC SCREEN SUPPORT S-6014 1�j _II 9 IL�I 1/16" REINF. SASH MTG. RAIL H-1497 1 151, 6" I rF 10 1 518" �1I L 1116" PVC SASH BTM. RAIL H-6051 1 3/16" 12 1 iif� 1/16" PVC SASH SIDE RAIL H-6004 1 1/8" 1/z^ 18 1/18" PVC SCREEN CATCH S-6013 3/4" 13 REINF. SBR/SSR S-1498 r 2 3/16" I � 8 1 518" 1/16" PVC SASH MTG. RAIL H-6027 �4" 3 15J16" ,/16„ REINF. SBR H-1699 138, 130 11} 6" 1/16" PVC SASH STOP S-6029 1/4• r 14 7/a" 15 16 17 PVC GLAZING BEAD S-6064 CONSTRUCTION WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.0 WS.CC 8100 PVC CORNER WELD (ALL SIDES) SINGLE HUNG 1:8 IMPACT 37 1- z aZ� ❑WO ¢WFO❑W z WJ❑ ~z W ❑ zOZ--F Qto� }Ow3:a ILL Z HW ZH3:g= Z= n Q w W O O O 0 0U)r-zahrAD- FIXED MEETING RAIL SCREWED TOGETHER WITH Z O 0 U uj j 0- OUTERFRAME 1:8 < F z W 2 0 O u. — g3 0Q¢:C)ul=F0` of}0wO 31/8" ZmW�O-W-+U)F- a w 1/" 5 IL 0 _ I — �W =� W �' IL o t- tr a L1 7/8" 0 INN...... t No 58201 1.1A HD MTG RAIL H-1681 :9: STATE OF �23118• 13l4"--I We4'*%4OR1QF'���`� 31 '14 /ONAI-0jle 15/16" 1N8" PVC MTG RAIL COVER S-6077 0 3/16" O 1 5116" 1!2" 5•3l16^ 7i8" 6 vs^ � 10 3" D F IMPACT HOOK SCREW SUPPORT P-3113 S-1577 LINE ITEMS NOT USED: 7 11 21-22 29 41 43, 49 50, 55, 57-61, 69 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. 9/25/z017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE, NORTH PORT, FL 342 PH.941-380-1574 Duraseal Allmetal Alum Allmetal Alum Allmetal Plastic Bettervue Fiberglass SHEET DESCRIPTION: BOM AND EXTRUSIONS Dapa Vinyl Summit Alum 9.Screen SS DRAWN BY: ADE DATE: 09/12/08 r. Plastics Nylon Sullivan Steel Fastenal Zinc DWG s: CWS-295 REV.: E Sullivan Zinc Fastenal Steel SCALE 12 SHEET 4OF6 6" MAX 6" MAX. 12" MN m ANCHOR A' RAIL CENTI mP•) 4" WINDOW SYSTEMS N 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 8100 PVC SINGLE HUNG IMPACT SEE NOTE 2 Q Z aZ0 QWO INSTALLATION W z 0 Z w= Z W ANCHOR (TYP.) OLL F W 3 O Z F 3r _ Z ZS2alxwp0 O Or0 a=�� V UyFZdI-in CL OZVu)ZOLLV W O-0�O W(A iW R Zia LL OJa)F- O wP0 w=—,> a t=- O- M�a No 58201 ANCHOR LAYOUT - (FLANGE) *' -v: 9 ; STATE OF NOTES: ••rrnmum' 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1116" IS PRESENT. LOAD BEARING SHIMS SHALL BE �Z CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6. 9/25/2017 LUCAS A. TURNER, P.E. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. FL PE # 58201 1239 JABARA AVE. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT, FL 342, SPECIFIED IN TABLE 1, SHEET 6. PH. 941-380-1574 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. ANCHOR SCHEDULE AND INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL. DRAWN BY: DATE: ADE 09/12/08 S. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG#: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-295 E 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCa E SHEET FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMANVDMA 250(BOX WINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS) 1:25 5 OF 6 SUBSTRATE BY OTHE SEE TABLE 1 PERIMETER SEALANI BYINSTALLER INSIDE AND OUT SEALANT BEHIND FLANGE BY INSTALLE INSTALLATION ANCHOI SEE TABLE 1 SEALANT BEHIND FLANGE BY INSTALLEF PERIMETER SEALANT BYINSTALLER INSIDE AND OUT SUBSTRATE BY OTHEI SEE TABLE 1 TYPICAL HEAD ANCHORAGE SEE TABLE 1 VERTICALSECTION B TYPICAL SILL ANCHORAGE TABLE 1: APPROVED INSTALLATION FASTENERS SUBSTRATETYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.0 KSI MIN.) 3/16" rrW TAPCON 1-1/2" 1-1/9, HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.) 3/16' I W TAPCON 1" 2" CONCRETE (2.85 KSI MIN.) 3116" ELCO ULTRACON 1" 1" GROUT -FILLED CMU (ASTM C-90) 3/16" ELCO ULTRACON 1-1/4" 2-1/2" 2XMIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON OR ELCO ULTRACON I-W8" 7/9' 2XMIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 13/8" 7/9' 16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN) #1D-16 HILTI KWIK-FLEX OR ITW TEKS SELF -DRILLING SCREW FULLTHREAD THRU 0.060" 7/16" 1/8" ALUM. (6063 T5 MIN.) OR 1/8" STEEL (33 KSI MIN.) #10 GRADE 5 SELF TAPPING / DRILLING SCREW FULL THREAD THRU 0.126' 7116" MIN. EMBEDMENT SEE TABLE 1 1/4" MAX.SHIM— INSTALLATION ANCHOR SEE TABLE 1 -SUBSTRATE BY OTHERS SEE TABLE 1 MIN. EDGE DIST SEE TABLE 1 PERIMETER SEALANT BYINSTALLER INSIDE AND OUT SEALANT BEHIND FLANGE BY INSTALLER g HORIZONTAL SECTION 6 TYPICAL JAMB ANCHORAGE PERIMETER SEALANT BYINSTALLER INSIDE AND OUT C HORIZONTAL SECTION S BOX FRAME INSTALLATION HEAD AND SILL SIMILAR FOR BOX INSTALLATION FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED: - MIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED INSIDE AND OUT, FULL PERIMETER, BY INSTALLER. - PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SHOWN FOR FLANGE WINDOWS. 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W WW.CWS.CC 8100 PVC SINGLE HUNG IMPACT Q Z 7i <zo I- a W O Q F 0 W Z WJm IIIZOZ_ wt- _ LL I-W�ZO�m2 Z zm�<wWp0 O 01-0 C=FI U z— So - CL ZI-a ln Z 001--Z)Ufn �gO�UrZ F. 00��0Wfn I11 z�Wa O-1cnr-a. I OWI-X� 0 W d F- a a Wa rz 9/25/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 3425. PH.941-380-1574 j INSTALLATION DETAILS ADE 09/12/08 TG S: REV.: CWS-295 E 'ALE: SHEET 1:2 6OF6