HomeMy WebLinkAboutICC-ES EVALUATION REPORTREPORTV e(\AC>
Lude GOUAV DIVISION: 08 00 — 00 OPENING_ S
SECTION: 08 95 43—VENTS/FOUNDATION FLOOD VENTS
ILE COPY )c�-`���-'��9
REPORT HOLDER:
FLOOD FLAPS°, LLC
POST OFFICE BOX 1003
ISLE OF PALMS, SOUTH CAROLINA 29451
EVALUATION SUBJECT:
FLOOD FLAPS° AUTOMATIC FLOOD VENTS:
MODELS FFWF12; FFNF12; FFWFOS; FFNF08; FFWF05; FFNF05
ICC ICC 1CC
Look for
"2014 RE
(WSSPQ
ICGES E,
specificallj
recommen,
to any find
trusted marks of Conformity!
of Prestigious Western States Seismic Policy Council
in Excellence"
rluatlon Reports are not to be construed as representing aesthetics or any other attributes not
addressed, nor are they to be construed as an endorsement of the subject of the report or a 4i�
ition for its use. There is no warrantyICC Evaluation Service, J b3' LLC, express or implied, as
g or other matter in this report, or as to any product covered by the report. ,,� � �;� e,,, w o5
ai000 w�wiuecrr
2017 [CC Evaluation Service, LLC. All rights reserved.
Evaluation. Report
(800) 423-6587 1 (562)
1: 08 00 00--OPENINGS
08 95 43—Vents/Foundation Flood Vents
HOLDER:
FLOO i' FLAPS°, LLC
POST FFICE BOX 1003
ISLE 8 PALMS, SOUTH CAROLINA 29451
(843) 8 „1-0190
TION SUBJECT:
rwuu FLAPS"' AUTOMATIC FLOOD VENTS: MODELS
FFWF1 FFNF12; FFWF08; FFNF08; FFWF05; FFNF05
1.0 EV LUATION SCOPE
i
Comp ante with the following codes:
■ 201 1, 2012 and 2009 Intemational Building Code® (IBC)
■ 201 2012 and 2009 Intemational Residential Code®
lit? 1
PropOties evaluated:
■ Phy ilCal operation
■ Wat r flow
■ Weal eying
2.0 US S
Flood aps® automatic flood vents are used to provide for
the eq' alization of hydrostatic flood forces on exterior
walls. ertain models also allow natural ventilation.
3.0 DE CRIPTION
3.1 G Ilneral:
Flood Elapse automatic 'flood vents are engineered
mecha 'ically operated flood vents (FVs) that automatically
allow fi ad waters to enter and exit enclosed areas. The
FVs ar constructed of ABS plastic which serves as the
FV's h, °using, and a front grill that contains an anodized
metal creen imbedded in polypropylene plastic. On
contact l�ith rising flood water, the grill will disengage from
its sec ed position, allowing flood water and debris to flow
throug in either direction. The FVs are available in two
series s described in Section 3.3.
ESR-3560
Reissued September 2097
This report is subject to renewal September 2oia
A Subsidiary of the Intemational Code Council
The sealed series models contain two rubber flaps that
Close the _ FV to the passage of air when using with
conditioned areas or sealed crawl spaces. In the same
manner as the grill, the two rubber flaps -are pushed open
by water pressure, allowing water and debris to flow
through the FV in either direction. See Figure 1 for an
illustration of the Flood Flaps® automatic FV.
3.2 Engineered Opening:
The Flood Flaps® automatic FVs comply with the design
principle noted in Sections 2.7.2.2 and 2.7.3 of ASCE/SEI
24-14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012 and 2009
IBC and IRC)] for a rate of rise and fall of 5 feet per hour
(0.423 mm/s). In order to comply with the engineered
opening requirement of ASCE/SEI 24, Flood Flaps®
automatic FVs must be installed in accordance with
Section 4.0.
3.3 Flood Vent Series Models:
Flood Flaps° automatic FVs are available in two series
with multiple models and sizes as described in Table 1.
The sealed series models, designated FFWF, include two
rubber flaps for the prevention of air flow. The multi-
purpose series, designated FFNF, omits the rubber flaps.
3.4. Natural Ventilation:
Flood Flaps®- automatic FV models FFNF12, FFNF08,
FFNF05, and FFNF02 have metal screens with 1/4 inch by
1/4 inch (6 mm bV 6 mm) openings and provide 37 square
inches (0.02 m2). of net free opening to supply natural
ventilation for under -floor ventilation. Flood Flaps®
automatic FV models FF1NF12, FFWF08, and FFWF05
have not been evaluated for use as openings for under-
floor ventilation.
4.0 DESIGN AND INSTALLATION
Flood Flaps® automatic FVs are designed to be installed
into walls of existing or new construction. Installation of
the FVs must be in accordance with the manufacturer's
Instructions, the applicable code and this report Flood
Flaps® automatic FVs can be installed in wood, masonry
and concrete walls up to a thickness of 12 inches
(305 mm). In order to comply with the engineered opening
design principle noted in Sections 2.7.2.2 and 2.7.3 of
ASCEISEI 24-14 [Section 2.6.2.2 of ASCE/SEI 24-05
(2012 and 2009 IBC and IRC)], the Flood Flaps® FVs must
be installed as follows:
■ With a minimum of two openings on different sides of
each enclosed area.
!CC -ESE tion Reports are not to be construed as representing aesthetics or any other attributes not specically addressed, nor are they to be construed
as an endo meet afthesubjed ofthe report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to arty findi pit
matter in this report, or as to any product covered by the report.
Copyright (0 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 3
ESR-3i60 I Most Widely Accepted and Trusted Page 2 of 3
■ Wi
fee
■ Be
■ Wi
12
5.0 Cl
The I
repor
speci
subje
5.1 .
i a minimum of one FV for every 220 square
(20 m2) of enclosed area.
)w the base flood elevation.
i the bottom of the FV located a maximum of
nches (305 mm) above grade.
NDITIONS OF USE
ood Flaps® automatic flood vents described in this
comply with, or are suitable alternatives to what is
sd in, those codes listed in Section 1.0 of this report,
t to the following conditions:
ie Flood Flaps° automatic FVs must be installed in
;cordance with this report, the applicable code and
e manufacturer's installation instructions. In the
rent of a conflict, the instructions in this report
5.2 The Flood Flaps® automatic FVs must not be used in
place of "breakaway walls" in coastal high hazard
areas, but are permitted for use in conjunction with
breakaway walls in other areas.
6.0 EVIDENCE SUBMITTED
Data in accordance with the ICC-ES Acceptance Criteria
for Mechanically Operated Flood Vents (AC364), dated
August 2015.
7.0 IDENTIFICATION
The Flood Flaps® models recognized in this report are
identified by a label bearing the manufacturer's name,
the model number, and the evaluation report number
(ESR-3560).
TABLE 1—FLOOD FLAP AUTOMATIC FLOOD VENT MODEL SIZES
MODEL
NUMBER
MODEL
DESIGNATION
ROUGH OPENING
(Width X Height)
(inches)
VENT SIZE
(W X H X D)
(inches)
ENCLOSED AREA
COVERAGE
(fe)
NET FREE AREA
OPENING
(in )
l FFWF12
Sealed Series
16 x 8
15 /a X /a X 12
220
NA
l FFNF12
Multi -Purpose
16 x 8
1 els X /s X 12
220
37
l FFWF08
Sealed Series
16 x 8
15 /B x /a x 8
220
NA
l FFNF08
Multi -Purpose
16 x 8
15 /e x /4 x 8
220
37
FFWF05
Sealed Series
16 x 8
15 /a x 7 /a x 5
220
NA
111 FFNF05
Multi -Purpose
16 x 8
1518 x /a x 5
220
37
si: 1 Incn = z5.4 mm; 7 r- = u.uuj n -
under -floor ventilation only.
ESR-3;560 I Most Widely Accepted and Truste, Page 3 of 3
LI
FIGURE 1—FLOOD FLAPS® AUTOMATIC FLOOD VENT
ij
FFtil1,TFI2 FFNF08 FFNF05
FIGURE 2—FLOOD FLAPS® AUTOMATIC FLOOD VENT SERIES MODELS
12" DEPTH S" DEPTH 5" DEPTH
FIGURE 3—FLOOD FLAPS® AUTOMATIC FLOOD VENTS MULTIPLE DEPTH OFFERINGS