HomeMy WebLinkAboutPRODUCT APPROVAL MODIFIED BITUMENT ROOF SYSTEMOF W6
Professional Regulation
DBP)!Hf)dE ABOUT 09l?IJ_ODI U)9rOM9. CONTACT DBPR
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Applicaton List > Application Detail
FJ
Application Type
Code Version
Application Status
Comments
Archived
%RmductzManufacturera>
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
tM654=R22'
Revision
2017
Approved
C
ROLWGMr S— US A
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1378 Ext242
alender@polyglass.com
Ariel Lender
alender@polyglass.com
Maury Alpert
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912) 429-8610
MAIpert@polyglass.com
I[!�o-1-v 15-9
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COMPLIANCE
REVIEWED BY
DATE
PLANS AND PERMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
THESE PLANS AND ALL PROPOsID ►r��"';
ARE SMECT TO ANY CORREC T IC;N13
REQUIRED UY-Flo IILISFEC i CRS :.;T
"AY SE NECESSARY IN ORDER To
COMPLY WITH ALL APPLIC;3 P,: ;7 (4
Quality Assurance Representative Ariel,Lender CONCUR
Address/Phone/Email 1111 W. Newport Center Drive FASTENERS ORAiTACHWSTS
Deerfield Beach, FL 33442 (954) 233-1230 ARE THE RESPONSIBILITY OF THE
ALender@polyglass.com CONTRACTOR OF RECORD
of-tategocy. goofing-
cSsrheategory, tNlo ifieEd i menmR"ooPSysterc►mifa.
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report Aft E
E
Florida License C66 .
UL LL
Quality Assurance Entity UL LLC FILP
Quality Assurance Contract Expiration Date 10/06/2018 J wo y
Validated By John W. Knezevich, PE
R6 Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL1654 R22 COI 2017 01 COI Nieminen.pr�if
Standard
Year
ASTM D6162
2008
ASTM D6163
2008
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2009
FM 4470
2012
FM 4474
2011
r
UL 1897
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method i Option D
Date Submitted
09/14/2017
Date Validated
09/15/2017
Date Pending FBC Approval
09/22/2017
Date Approved
12/12/2017
Summary of Products
2012
FL #
Model, Number or Name
Description
1654.1
Polyglass SBS and APP Modified
SBS and APP modified bitumen roof systems
Bitumen Roof Systems
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL1654 R22 II 2017 09 FINAL Al ER POLYGLASS MODBIT FL1654-
R22.pdf
Verified By: Robert Nieminen PE-59166
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application
relates to one particular assembly over concrete
Evaluation Reports
FL1654 R22 AE 2017 09 FINAL ER POLYGLASS MODBIT FL1654-
R22.pdf
deck. Refer to the ER Appendix for other systems and
deck types. 2.) Refer to ER, Section 5 for other Limits
Created by Independent Third Party: Yes
of Use.
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. CoPyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
Credit Card
Safe
I
TRINITY I ERD
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table
Deck
Application
Type
Description
Page
1A
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
16-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
16-2
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
10-11
1C
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
it
1D
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-13
1E
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
14-15
1F-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
16-18
1F-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
19-21 .`
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22-24
28
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
25-28
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
29-31
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
32-40
3B
Structural concrete
New or Reroof (Tear -Off)
F
Nan -Insulated, Bonded Roof Cover
40
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
41-42
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
43
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
44-46
SA
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
47
5B
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
48
5C
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
49
SD
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
49
5E
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
49
6A
Gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
50-52
6B
Gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
52
6C
Gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
53
6D
Gypsum
Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
53
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
54-58
7B
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
58
The following notes apply to the systems outlined herein:
The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢ Wood: Minimum 0.75-inch penetration.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted, Insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the CLA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover.
Exterior Research and Design, I.I.C. d/b/a Trinity( ERD Evaluation Report P9290.02.08-R20 for FL3654-R22
Certificate of Authorization 99503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 1 of 58
TRINITY I ERD
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
TABLE 1: POLYGLASs ROOF COVERS
Reference
Layer
Material
Application
BP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II
Hat Asphalt at 20-40
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
(Base and Ply sheets, Asphalt-
Ibs/square
Note:
Asphalt -applied -sheets or insulation shall not be applied to poly -film surfaced membranes.
Applied)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type II, Polyglass HT Base 650
PG350 at 1.5-2.0
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshleld
SBS-CA1
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
"Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type 11
SBS-CA2
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshleld TS-G, Elastoshleld
Polyplus 35 at 1.5-2.0
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply or Ply
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex
SBS-AA
56 Type II, Polyglass HT Base 650
Hat Asphalt at 20-40
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G,
(SBS, Asphalt -Applied)
Ibs/square
Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note:
Asphalt -applied sheets or insulation shall not be ap lied to poly -film surfaced membranes.
Base Ply or Ply
650 or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 Type 11, Polyglass HT Base
SBS-TA
Torch -Applied
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type II, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshleld TS-G,
(SBS, Torch -Applied)
Elastoshleld TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed)
Base Ply
One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
SBS-SA
Cap Ply
Elastoflex SA P, Elastoflex SA P FR, Pal reflect
Self -Adhering
Note:
Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein,
(SBS, Self -Adhering)
Elastobase (poly/sand) or Elastobase ( of / of ).
APP-CA1
Cap Ply
Polyflex G FR
PG350 at 1.5-2.0
-gal/square
APP-TA
Base Ply or Ply
One or more plies Polyglass APP Base, Polyflex, Polybond
Torch Applied
Cap Ply
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
(APP, Torch -Applied)
P o
16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance.
associated with coating usage.
➢ PG200 Non Flbered Roof Coating;
➢ PG300 Flbered Roof Coating;
➢ PG600 Non-Flbered Aluminum Roof Coating;
D PG650 Flbered Aluminum Roof Coating;
➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25;
➢ PG700QS (Quick Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (for granule -surfaced APP or SBS only);
➢ PG800 Asphalt Emulsion Roof Coating;
D Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
➢ Polyplus 65 Premium Fibered Aluminum Roof Coating;
➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15;
D Polybrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 25-QS (forgranule-surfaced APP or SBS only);
➢ Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
Exterior Research and Design, I.I.C. d/b/a TrinitylERD
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 394-1230
Refer to current Roofing Materials Directory for fire ratings
Evaluation Report P9290.02.08-R20 for FL1654-R22
Revision 20: 09/12/2017
Appendix 1, Page 3 of 58
TRINITY I ERD
TABLE 1F-2: WOOD DECKS -NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER
System
I
Base Sheet
I Roof Cover (Note 15)
MDP
No.
Deck (Note 1)
Type
Fasten
Attach
Base Ply
Cap
(psi)
SELF -ADHERING BASE PLY:
W-136
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast 414
12-inch c.c. in 4-Inch lap and 12-inch o.c. in two
SBS-SA
SBS-SA, APP-SA, SBS-
52 5"
Inch plywood
(poly -film top)
orTrufast 3" Metal InsulationPlate with Trufast HD
(2), equally spaced, staggered center rows
TA, APP-TA
W-137
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
12-Inch o.c. In 4-inch lap and 12-inch o.c. in two
Polyflex SA Base
APP-TA
-52.5"
Inch plywood'
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
W-138
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrip #12
12-inch o.c. In.4-inch lap and 12-inch o.c. in two
SBS-SA
SBS-SA, APP-SA, SBS-
60.0"
Inch plywood
(poly -film top)
(2), equally spaced, staggered center rows
TA, APP-TA
W-139
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrip #12
12-inch o.c. in 4-Inch lap and 12-inch o.c. in two
Polyflex SA Base
APP-TA
Inch plywood
(poly -film top)
(2), equally spaced, staggered center rows
TABLE 1G: WOOD DECKS- NEW CONSTRUCTION OR REROOF (TEAR -OFF)
SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER
System
Deck (Note i)
Primer
Roof Cover (Note 15)
MOP (psf)
Joint Treatment
Ply
Cap Ply
No.
W-141
Min. 15w2-
(Optional) PG100
None
"BasjePly
Polyflex SA Base
(Optional) APP-TA
APP TA
-90.0
Inch plywood
W-142
Min. 15/32-
PG100
None
SBS-SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS
97 5
Inch plywood
TA, APP-TA
TA, APP-TA
W-143
Min.15/32•
(Optional) PG100
Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Base or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
97.5
Inch plywood
place to create continuous bond.
Elastoflex SA V FR Base
TA, APP-TA
TA, APP-TA
W-144
Min.15/32-
WB-3000
None
SBS-SA
(Optional)
SBS-SA, APP-SA, SBS-
-105.0
Inch plywood
TA, APP-TA
W 145
Min. 15/32-
(Optional) PG100
Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Plus or
(Optional) SBS-SA; SBS-
SBS-SA, APP-SA, SBS
135.0
Inch plywood
place to create continuous bond.
Elastoflex SA V Plus FR
TA, APP-TA
TA, APP-TA ,
W-146
Min. 15/32-
(Optional) PG100
Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled Into
Polyflex SA Base
(Optional) APP-TA
APP-TA
135.0
Inch plywood
place to create continuous bond.
r
Exterior Research and Design, I.I.C. d/b/a Trinityl ERD Evaluation Report P9290.02.08-R20 for F1.1654-1122
Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1MG Appendix 1, Page 21 of 58