HomeMy WebLinkAboutBLOWER DOOR TESTMCA' ' i BY _..�__ __.__....._-_... Planning & Developme t 55 e 1' Building &Code Regu ate' n�®��^0 U v 1COUNT 2300. Virginia Ave, Rm 201 . ' I D A Fort Pierce, fL 34982 Phone: 77 t 462-2165 Fax: 772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method it Date: 13 //1 Permit #: -1 ,�-0 -7 `7 -7q ContraUtz, ctor:140 Job A 'dress: I Const uction: (. ) New Construction — Complete. �� , p ( )Existing —After Addition Hous ,' Infiltration st Results SLC Climate Zone 2 n / .CFM Ag 0) _ Test Date: (;c Volu e = `tL p ACH 50) = CFM (50) x 60 / Volume Mechanical Ventilation required less than 3 ACH . Passi g results must be & ACH (50) or less N) Pass ( )Fail FBC E ergy The b 'gilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour Iii Climate Zone 1,:2 and 3 air changes per hour in Climate Zones 3 through B. Testing shall be conducted with a blowll door at a pressure of 0.2 inches w. g. (50 Rascals). Testing shall be conducted by either individuals as defined in SectioP 553.993(5) or (7), Florida Statutes or individuals licensed asset forth in Section 489.105 3 f ( )( ), (g) or (i) or an appi . � ed third party. A written report of the results of the test shall be signed by the party. conducting the test and provided to the code official.:Testing:shall be performed at any time after creation of all penetrations of the building then I'` 1 envelope. FBC, esidential Whe I' the'air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2_inch w. c..(50 Pa) in accordance.with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the d"elling unit -shall be. provided with whole=house mechanical ventilation in accordance with Section M15073.- Testihit, Com an Com any Name: r .: Address: l e b7 % i \,Q , YY1Yri�C�c CV , �Si•- I her.1,b ce ify that the ab ove House Infiltration results demonstrate compliance with FBC Energy Conservation requ,,reme t in accordanc Section R402.4,V.2 Climate -Zone 2. Signs ure- Prinl�`� Na e: J Q a GhClse_� Lice nse/Certification .#:. p�--_ II RECEIVED JUN 14 2019 Permitting Department St. Lucie CountyL 7 Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 772-462-2165 Fax 772-462-6443 FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method Date: Permit #: 1 Wu d Lot #: Contractor; Address: / o� `i �d J �11 '� bi-, P/L2f & _ Construct! : ' Post Construction Test ❑ Rough -in Test Test Conditions:. Date: I f 3 �+ t 7 Floor Area (ft2): Time: �'I 1 i0 oy Primary Location of Supply Ductwork ( G Indoor Temperature (F): —17 Primary Location of Return Ductwork iv Outcl rTemperature (F): Sl li Duct Le#kage:. ❑ DefauI ❑ Prop. Leak Free Proposed On = d . D 3 Test Pressure: 5 (Pa) I Baseline, Duct Pressure (optional) (Pa) % �(, � �r V t o 2 Duct Pr ss. (Pa) Flow Ring. Fan Press Flow (cfm) Results: 'APass ❑ Fail k Installed Pa cc< j Total Leakage (cfm): . J 1 11 Total Leakage per 100 sgft: CFW' CFM25 x 100 divided by the CFA = Duct Leakage CFW100 sqft. Testing Company Compan Name: Address: �J w W �r �' Cv I hereby certify that ove D ea i g Leakage re ul s demonstrate compliance with 5"h Edition FBC Energy Conservation requirements in accordance with Section R403.2.2. Signatur� I: Printed Name: S© �Gr-2 ` License/Cert�cate #: &­d �� � 2- � �2_ ki RE '. E'L) JUN 14 2019 Permitting De St. Lucie CouDepartment nty, FL,