SETUP AND INSTALLATION OF SINGLE WIDE SHED
1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR
MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC.
2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE -GROUND IS ESTABLISHED, THE
BUILDING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE
BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING
IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED.
3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT
SPACING (SEE TABLE 3).
4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED
THRU THE 2%4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL
1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE.
5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO
FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS.
6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND
BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE
CONCRETE 1-1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM
PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2"
WEDGE ANCHOR.
7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE
2"x4" BOTTOM PLATE.
TABLE 1
ANCHORING TO CONCRETE
SHED WIDTH
UPLIFT (PLF)
ANCHOR SPACING
20'-0"
400
S-6"
13'-8"
280 -
S-6"
11'-8"
240
S-6"
10'-0"
200
S-6"
8'-0"
160
S-6„
6'-0"
120
S-6"
TABLE 2
SKID RUNNER SPACING*
SHED WIDTH
X1
X2
X3
13'-B"
1'-104"
1'-104"
1'-104"
11'-8"
2'-8"
6'-4"
-
10'-0"
V-7"
6'-10"
-
8'-0"
0'-9.
6'-6"
-
C-O"
0'-10"
51"
-
*VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"x4"
SKIDS ONLY. 13'-B" WIDE SHEDS HAVE (4) SETS OF SKIDS.
SETUP AND INSTALLATION OF DOUBLE WIDE SHED
1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS
PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP.
2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE
BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3).
3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL -WITH THE
FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)A x44"
BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE
LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS
PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE.
4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B).
5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS
REMOVED.
6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO
FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS.
SCANNED
BY
lot.�.IfDO� IJ®Uhw
TABLE 3A
PAD TYPES
TYPE
PAD DIMENSIONS
MAX. LOAD*
MATERIAL
I
2"x8"x16"
1778LBS
CONCRETE BLOCK QUALITY
CEMENT AND SAND MIX
II
4"x8"x16"
3500LBS
CONCRETE BLOCK QUALITY
CEMENT AND SAND MIX
III
16%16"
3950LBS
ABS PLASTIC PADS
IV
8"x8"x16"
1900LBS
CONCRETE BLOCK QUALITY
CEMENT AND SAND MIX
* BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPICAL)
NOTES
1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED
ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING.
2- ABS PADS REQUIRED ON 11'-8" AND 13'-8" WIDE SHEDS ONLY.
TABLE 3
SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS
SHED DESCRIPTION
PAD
MAXIMUM LOAD AND PAD TYPE
SHED WIDTH
TYPE
LW*(PLF)
END PAD
MAX. SPACING
END PAD
SIDE RUNNER
PAD TYPE
INTERIOR
PAD
SIDE RUNNER
PAD TYPE
SW/DW
4.15/332
0" TO 6"
6'-0"
1936LB
I, II, III, OR IV
1879LB
I, II, III, OR IV
SW/DW
6.00/480
0" TO 6"
6'-0"
2558LB
I, II, III, OR IV
2558LB
I, II, III, OR IV
10'-0"
SW/DW
5.00/400
0" TO 6"
6'-0"
2400L8
I, II, III, OR IV
2400L6
I, II, III, OR IV
8'-0"
SW
4.00/320
0" TO 6"
6'-0"
2029LB
I, II, III, OR IV
2133LB
I, II, III, OR IV
C-O"
SW
3.00/240
0" TO 6"
6'-0"
1658LB
I, II, III, OR IV
1866LB
I, II, III, OR IV
* LOAD WIDTH OF UPLIFT ON RUNNER
NOTES
1. PAD SPACING IS END TO CENTER OF PAD.
2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER.
3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING.
2"x2" GALVANIZEQ_WASHER_
�' .. .7.2 NUT
1/2" THREADED ROD
OPTIONAL FOR *HIGH S
1/2" COUPLER
1/2"x11 FORGED EYEBOLT,
EYES BOLTED TOGETHER WITH
BOLT & NUT WITH (2)2"x2" GA
WASHERS (2.000LB SHEAR 1
30" EARTH AUGER
(SEE TABLE 4 FORRj
ST. LUCIE COUNTY
BUILDING DIVISIO
REVIEWED
SEP 10 2018
Permitting Uepertment
St. Lucie County, FL
THESE PLANS AND ALL PRO26-10SED W
ARE SUBJECT TO ANY CO¢IRECTiON
DATE "i IO pS,m ��R*
PLANS A It IT
MUST BE KEPT ON OB OR
NO INSPECTION WIL BE MADE
!=GA6vANIZ
WITH 1/2" NUT
EYES BOLTED TOGETHER WITH 1/2"x2"
BOLT & NUT WITH (2)2"x2" GALVANIZED
WASHERS (2.000LB SHEAR CAPACITY)
OR IV PAD WITH 1/2"x3" (400 LB.)
REQUIRED (SEE TABLE 3). CONCRETE WEDGE ANCHOR
�3 (SEE TABLE 1 FOR SPACING)
-AlAppliumm CODES.
1/2" THREADED ROD
OPTIONAL FOR "HIGH SET"
1/2" COUPLER
�4" MIN.
d'
SIMPSON A-24 CONCRETE SLAB
CLIP OR EQUAL LOCAL ES -A
SHED WITH SKID
ANCHORED TO CONCRETE
GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS
1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE
AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE
HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS.
2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER).
LOCATE ANCHORS PER TABLE 4A OR 48.
3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE
(FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH
THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED
PORTIONS OF SHEDS ON LEVELING BLOCKS.
ARE
BY OTHERS THROUGH
TABLE 4A
30" AUGER ANCHOR SPACING - SINGLE WIDE
SHED WIDTH
LW*
UPLIFT (PLF)
END ANCHOR**
MAX. INTERIOR SPACING***
13'-8"
7.00
243
0'-v TO S-o"
10'-0"
--8�"
6.00
208
-0-0"
0'" TO 3'
10'-0"
"T ( 0 -- "_
=;5:00 _::..
=-174a_
-0 -0"`TO-3'-0"
1.0,_O" -4
8'-0"
4.00
138
0'-T TO S-T
10'-0"
6'-0"
3.00
104
0'-0" TO 3'-0"
10.-0. `
TABLE B
30" AUGER ANCHOR SPACING - DOUBLE WIDE
SHED WIDTH
LW*
UPLIFT (PLF)
END ANCHOR**
MAX. INTERIOR SPACING***
20'-0"
1 10.00
400
0'-0" TO S-O"
5'-0"
* LOAD WIDTH OF UPLIFT ON RUNNER
'• LOCATION FROM END WALL OF AUGER ANCHOR
••• MAXIMUM SPACING BETWEEN ANCHORS
NOTES
1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7.
2. ALL MEASUREMENTS ARE CENTER -TO -CENTER.
3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER.
ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0"
BETWEEN ANCHORS..
4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN
EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE
TO THE SIDE AS POSSIBLE.
RESPONSIBILITY OF TH
1/2"x5" (400 LB.) CONCRETE
WEDGE ANCHOR INTO SLAB
THRU 2"x4" P.T. BOTTOM PLATE
(SEE TABLE 1 FOR SPACING)
NOTCH OR COUNTERSINK BOLT
THRU 2"x4" BOTTOM PLATE
2"x4" BOTTOM PLATE NAILED
TO 2"x6" P.T. BASE
_t4" MIN.
CONCRETE SLAB BY OTHERS THROUGH
LOCAL CODES AND JURISDICTION
SHED WITH 'NO FLOOR' OPTION
CODE VERSION
FBC 2017 Sth Edition, ASCE-7
MANUFACTURER
SUPERIOR SHEDS
BUILDING TYPE
MANUFACTURED BUILDING
RESIDEMT16L LAWN STORAGE
CONSTRUCTION TYPE
V-B
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
STORAGE
ALLOWABLE NUMBER OF STORIES
1
BASIC WIND SPEED
Va-2DO.ph
EXPOSURE
D
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEFFICIENT
+/- 0.18
IMPORTANCE FACTOR
1.15
ROOF DEAD LOAD
1OPSF -
ROOF LIVE LOAD
20PSF OR 3001be
FLOOR DEAD LOAD
8PSF
FLOOR LIVE LOAD
STD. 75PSF - 125PSF OFT.
"R" RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
LESS THAN 720 SQFT.
DESCRIPTON
(n MTB
Q Dote:
Ld 4/26/16
Scale:
(n N A
odel
LJJ ALL
GENERAL NOTES
1. FOUNDATION PLANS ARE NOT PART OF THIS
PLAN SET AND ARE GOVERNED BY LOCAL
JURISDICTION.
w 2. THIS BUILDING IS EXEMPT FROM THE FBC
ENERGY CONSERVATION CODE PER SECTION J
1015.22.
m 3. REFER TO TIE -DOWN DETAILS FOR PROPER
::::) INSTALLATION REQUIREMENTS TO MEET CODE.
O
0
W
J
0
Z
(n
LLI
_o I 6/1/18
TIE -DOWN DETAILS
Flo1ida"LicenseVysasas
(n - -
z Sheet; AD ' 1 OF 1