Loading...
HomeMy WebLinkAboutBUILDING PLANS PAGE 1-21• STATE OF FLORIDA CERTIFIED BUILDING CONTRACTOR: DR HORTON HOMES 1430 CULVER DRIVE NE PALM BAY, FL 32907 TEL: (321) 733-7092 FAX: (321) 733-7972 • STATE OF FLORIDA PROFESSIONAL ARCHITECT: ROLAND A. ABOUCHACRA AR No. 93723 A.B. DESIGN GROUP, INC. 1441 NORTH RONALD REAGAN BLVD. LONGWOOD, FLORIDA 32750 Tel: (407) 774-6078 Fax: (407) 774-4078 DRAWING / CONTRACT DOCUMENT THE BUILDER ASSUMES ALL LIABILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS. IF ANY ASPECT OF THE CONSTRUCTION (AS DESCRIBED IN THIS DRAWING SET) ARE UNCLEAR AND IN NEED OF FURTHER DETAILING OR EXPLANATION IN ORDER TO BUILD THIS PROJECT BASED ON THIS DRAWING SET, THE CORRECT PROCEDURE IS FOR THE BUILDER TO SUBMIT A WRITTEN R.F.I. (REQUEST FOR INFORMATION) TO THE ARCHITECT OR ENGINEER FOR CLARIFICATION. AB DESIGN GROUP WILL RESPOND TO ALL WRITTEN RFI's IN WRITTEN/DRAWN FORMS IN A TIMELY MANNER. AB DESIGN GROUP TAKES NO RESPONSIBILITY FOR INTERPRETATIONS OF CONSTRUCTION BY THE BUILDER WHEN NO RFI's HAVE BEEN GENERATED FOR UNCLEAR ASPECTS OF THE CONSTRUCTION BASED ON THE DRAWING SET. 99 2 13 605 o DESIGN CRITERIA: AY, A � .) _L_j I\ 1430 CULVER [DRIVE NE, F'ALM BAY, FL 32907 Tel= (321) 733-7092 Fax: (321) 733-7972 • FBC RESIDENTIAL 6TH EDITION (2017) ABC • FLORIDA FIRE PREVENTION CODE 6TH EDITION ADJ. • NATIONAL ELECTRICAL CODE (NEC) — 2014 EDITION AMP. *ALL LOCAL AND STA°E CODES BD. CL CAB. • OCCUPANCY - RESIDENTIAL, GROUP R3 CLG. •CONSTRUCTION TYPE - VB C COONN C. • MIN. INTERIOR FINISH — CLASS B CPT • BASIC WIND SPEED - Vult=160 MPH C.T. D. Vasd=124 MPH DBL. • EXPOSURE — C D.G. DIA. • 1—STORY RESIDENCE — DIM. • 2—STORY RESIDENCE — MAX. HEIGHT AS PER LOCAL DISP. DP. AND STATE CODES DR. D.S. SQ.FT. CALC.'S DW EA. ELEV. IST FLP, LIVING 1104 SQ. FT, EQ. 2ND FLR LIVING 1501 SQ. FT. EXH. EXT. TOTAL LIVING 2605 Sa FT. F.G./FX . F.G. GARAGE 431 50. FT. FIN. COVERED LANAI 80 50. FT, FLU. FLUOR. PORCH III SQ. FT. FR. DR. FTG, TOTAL 3233 SQ. FT. GA, GAR. DISP. G.F.I. A/C VOLUME 216912 GL. GYP. BD. H.B. IT HDR. H GT. OR HT TN S UL. N T. LAV. LEM. M.C. REVISIONSS�oN INDEX OF DRAWINGS ARCHITECTURAL SHEET DESCRIPTION ABGVEABBREVIATIONS MANUFACTURER MFR.AIRCONDITIONING MIN. MINIMUM ADJUSTABLE M.T. MOUNTTED THRESHOLD ALTERNATE MTD. MOUNTED AMPERAGE MTL. METAL BOARD N.T.S. NOT TO SCALE CENTERLINE O.C. ON CENTER CABINET PL PROPERTY LINE CEILING P.B. PUSH BUTTON CLEAR PH. PHONE CONCRETE PUT. PLATE CARPET PLYWD. PLYWOOD CERAMICTILE PR. PAIR DRYER P.T. PRESSURE TREATED DOUBLE R. RISER DUAL GLAZED RAD. RADIUS DIAMETER R.A.G. RETURN AIR GRILL DIMENSION REF, REFRIGERATOR DISPOSAL RM. ROOM DEEP R.O. ROUGH OPENING DOOR S.C. SOLID CORE EXT DR DOWNSPOUT S.D. SMOKE DETECTOR DETAIL S.H. SINGLE HUNG DISHWAgHER SHT. SHEET EACH SHTHG. SHEATHING ELEVATION SHWR. SHOWER EQUAL SJM. SIMILAR EXHAUST SL. SLIDING EXTERIOR SL. GL. SLIDING GLASS FIXED GLASS STD. STANDARD FUEL GAS SWS SHEAR WALL FINISH SECTION FLOOR TEMP. TEMPERED GLASS FLUORESCENT THK. THICK FRENCH DOOR T.O.C. TOP OF CURB FOOTING T.O.P. TOP OF PLATE GAUGE T.O.S. TOP OF SLAB GARBACIE DISPOSAL TYP. TYPICAL GROUND -FAULT U.N.O. UNLESS NOTED CIRCUIT INTERRUPTER OTHERWISE GLASS V.P. VAPORPROOF GYPSUM BOARD W. WASHER HOSE BID W/ WITH HOLLOW CORE WD. WOOD HEADED WDW. WINDOW HEIGHT W/H WATER HEATER INSULATION W.I. 'WROUGHT IRON INTERIOR LAVATORY LUMINOUS MEDlcuvi CABINET DATE PG Cl—COVER SHEET PG GN—GENERAL NOTES PG AI —FIRST FLOOR PLAN PG AlA—FLOOR PLAN SEC�I,ONS/DETAILS PG A2—SECOND FLOOR P: N PG A3H—ELEVATIONS FRONT & REAR "H" PG A4H—ELEVATIONS LEFT & RIGHT "H" PG El —FIRST FLOOR ELECTRICAL PLAN PG E2—SECOND FLOOR ELECTRICAL PLAN PG Pi —PLUMBING PLAN PG Ml—FIRST FLOOR MECHANICAL PLANS PG M2—SECOND FLOOR MECHANICAL PLANS PG DI —DETAILS PG D2—DETAILS PG D3—DETAILS PG D4—PRODUCT APPROVALS PG WAl—WALL ASSEMBLY DETAILS PG WA2—WALL ASSEMBLY DETAILS PG WA3—WALL ASSEMBLY DETAILS PG WA4—WALL ASSEMBLY DETAILS PG WA5—WALL ASSEMBLY DETAILS PG WA6—WALL ASSEMBLY DETAILS - STRUCTURAL SHEET # DESCRIPTION PG Sl—FOUNDATION PLAN PG S1.IA—DETAILS PG S1.1B—DETAILS PG S1.2—FIRST FLOOR DOWEL PLAN PG S1.2A—DETAILS PG S2—FIRST LIFT BEAM PLAN AND NOTES PG S2.IA—DETAILS PG S3—FIRST FLOOR FRAMING PLAN PG S3.1A—DETAILS PG S3.1B—DETAILS PG S4—SECOND FLOOR PLAN PG S4.1A—DETAILS PG S4.2—SECOND FLOOR DOWEL PLAN PG S5—SECOND LIFT BEAM PLAN AND NOTES PG S6—ROOF FRAMING PLAN PG S6.1A—DETAILS PG SNl—DETAILS 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 A4 W 03 v W 0 y Eti ti J7 SUSDIV. 8e LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SIYING: RIGHT PAGE: COVER SHEET 60 MPH EXP. C DATE:: 05/23/18 SCALE: 1/4"=1' — 0" SHEET CI ck� 0 V J H 0 a 0 0 w GENERAL NOTES SITE WORK TIMBER 1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR) 1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT). 1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED 6th EDITION, (2017).AND IN CONJUNCTION WITH ACE 7-10. ALL REFERENCED CHAPTERS, CODE SECTIONS AND TABLES STATED HEREIN: IN THESE DOCUMENTS ARE UNDER FBCR 6TH EDITION (2017) UNO. 2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES, A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL 2. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL B. NATIONAL FOREST PRODUCTS ASSOCIATION: I. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY FINISH GRADES, PLANTING AND IRRIGATION. C. SOUTHERN PINE INSPECTION BUREAU: THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE I. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER DESIGNED AND INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.2.1.2. 3. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE D. TRUSS PLATE INSTITUTE: ARCHITECT. I. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI 2002) 3. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK E. APA -THE ENGINEERED WOOD ASSOCIATION PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. 4. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN 1/2 THE HORIZONTAL I. ENGINEERED WOOD CONSTRUCTION GUIDE DISTANCE FROM THE NEAREST EDGE OF THE FOOTING. F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS 4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. 5. ALL BACKFILL AT STRUCTURES. SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAR OF GRANULAR FILL. PLACE IN 8" 2. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE o LAYERS AND COMPACT TO 95 � MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557. THE CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR BUILDING SITE SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS. 3. MINIMUM NAILING PER CHAPTER 6- WALL CONSTRUCTION AND TYPICAL NAILING SCHEDULE ON PLANS. FABRICATION OF THE WORK. 6. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED. 4. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL COMPLY WITH CHAPTER 6- WALL CONSTRUCTION. 5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES, OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES. 7 DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE) 5 WALL SHEATHING SHALL BE PER STRUCTURAL, SEE ROOF/WALL/FLOOR SHEATHING FASTENER SCHEDULE ON SHEET SN1. 6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR 8. EXCAVATIONS TO BE A MINIMUM OF 3' 0" BEYOND NEW FOOTING LINE. 6. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24" AND THE MINIMUM AREA SHALL BE 8 FT . SQ. SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED. 9, THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE PLUMBING 7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REQUIREMENTS. 1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL. "A" 2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS. 8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL_ CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER. 10. THIS BUILDING IS NOT DESIGNED TO BE CONSTRUCTED WITHIN A FLOOD ZONE, UNO. CONTRACTOR IS TO VERIFY THE 3. CONDENSATION LINES SHALL BE MINIMUM %" PVC (SCHEDULE 40), INSULATED WITH ''/" AMAFLEX. ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY WHICH COMPLIES WITH ALL LOCAL 4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH. 9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR WIPES, DUCTS, ETC, UNLESS SPECIFICALLY DETAILED. CODES HAVING JURISDICTION, INCLUDING ALL APPLICABLE STATE, CITY, AND COUNTY BUILDING AND ZONING CODES. 5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE. 6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES. GARAGES AND CARPORTS 11. SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP 7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO SECTION P3005.2. 1. GARAGE DOOR DRAWING. 8. FIXTURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903. A. ENGINEERED FOR MIN. WIND LOAD, LISTED ON COVER SHEET 9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER 12. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, 10. DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF SECTION P2603.2. C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMENT PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE EXTERIOR WALL COVERINGS 2. AS PER SECTION .1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE 1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR L NOT PERMITTED OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH PURPOSES SHALL NOT BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: THE WALLS FOR COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH TABLE R301.2(2) AS MODIFIED BY TABLE T INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN SOLID WOOD DOORS NOT LESS THAN 1 "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. R301.2(3), MANUFACTURED SOFFITS SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE 1-3/8 INCHES THICK, OR 20-MINUTE FIRE -RATED DOORS. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF 3. AS PER SECTION R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE AGRICULTURE AND CONSUMER SERVICES." EXTERIOR FINISHES 1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, %" THICK, OVER FRAMED WALLS DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO.26 GAGE (0.48 MM) SHEET STEEL 1" MIN, RIGID ON -METALLIC CLASS OR CLASS 1 DUCT BOARD OFF OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS THAN 2 COATS, 1/2" THICK, WHERE APPLIED OVER MASONRY OR CONCRETE. GARAGE. 2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE WITH 4. AS THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT PER SECTION & TABLE R ASTM-C926 & ASTM-C1063-12a. D APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE H GYPSUM BOARD AP LESS THAN''/z -INCH GYPSUM LE 3. LATH & ACCESORIES PER ASTM-C-1063-1 & R703.7.1. ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT LIMITED TO: SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR EQUIVALENT. ALL STUCCO CONTROL JOINTS KICK -OUT DETAILS WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE - "L" FLASHING HORIZONTAL LATH AND PAPER DETAILS PROTECTED BY NOT LESS THAN'/ -INCH GYPSUM BOARD OR EQUIVALENT. PIPE PENETRATION DETAILS VENT PENETRATION DETAILS WEEP SCREED DETAILS CONDUIT PENETRATION DETAILS - CASING BEAD DETAILS DRIP EDGE DETAILS CANTILEVER DRIP EDGE DETAILS CORNER BEAD DETAILS WINDOW CASING DETAILS STUCCO TO SIDING TRANSITION DETAILS WINDOW FLASHING DETAILS 4. SHALL BE INSTALLED PER ASTM-C1063 -11A AND R703.7. 2-STORY GYPSUM BOARD UNDER STAIR PROTECTION: 1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. R302.7. 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com L AA #: 0003325 1 M w 0 y 4 E SIUHDIV. 8e LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL: 4EHB "2605- HAYDEN" CgARAGE SV ING: RIGHT PAGE: GENERAL NOTES 460 MPH EXP. rswai s 05 23 18 DATE: / / SCAL'l: 1/4"=1'- 0" Z _L oil FLAME SPREAD AND SMOKE INDEX FOR WALL AND CEILING FINISHES SHALL BE IN ACCORDANCE WITH SECTION F15C R302.9.1 THROUGH FBC R302.9.4 FLAME SPREAD AND SMOKE -DEVELOPED INDEX FOR INSULATION SHALL BE IN ACCORDANCE WITH SECTION F15C R302.10.1 THROUGH FBC R302.10.5 7z CONTUJOUS STRESS DOU" TOP PLATE—�"�� d.00KM MID WALL Gp4w82' Or—MAX 2x STUDS to16' OII MAX. "Ox I' T S G SUBFLOOR &-L= AND SCMIM AS PER FASrNER wryeryu a a t FLOOR STUDS TO M R.00R STUDS SMPSON META-86 • W Or- MAX PRE -ENS FLooR Tliuee DOUEL.E TOP PLATE 2x STUDS • N.' O.o. MAX, "ON. 2x CONr"4" STRESS SECURE Dt. PLATE TO STUD V0-00cINO MID U ZL SU'1PSON SP4 632' OG. MAX SECURE W. PLATE TO GLAD UV txr ANCHOR DOLT W/ 2' 4A04PR,' EMOSL. MK • 32' I ISN T OF *ARAM =MAX. EPDXY NOT VARIES ON SLOPE RECUPRED FOR EXPANOM MOLTS 8 G.GGPto4 TGM Q No Cr—MAX ^' -..°4 4' CONC. REUFgGCED V 6'Xf' UAJGUL4 uGF oR gDEIa 7ES4 ON 6-MIL VAPOR Z 4 RETARDER ON "ELL -COMPACTED CLEN RLL. TEN'mE IFEATMERr To OE at 4' I'-0' 4' 4' DORA-CARE APPLED AT FRAMN& r2) �s REDAIU ON aaalea I'-S' A 2 STORY I1+TT. WALL AT GARAGE SCALE: WooI'-0" NOTE: NOTE:2-STORY GYPSUM BOARD OPENINGS BETWEEN THE GARAGE 4 RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOOR NOT LESS THAN No (35mm) IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN I4b'(35mm) THICK, OR 20-MINUTE FIRE -RATED DOORS THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE < ITS ATTIC AREA BY NOT LESS THAN 1/2'(12.1mm) GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS BY NOT LESS THAN ND'(15.9mm) TYPE X GYPSUM BOARD OR EQUIVALENT UNDER STAIR PROTECTION: ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2 INCH GYPSUM BOARDS. FBCR 2011 ((PTH ED.) 302.1 -10" 10'-0" I -4', '1'-4" U-4 4--------� COVERED I e'LAP+'N(.ALIG. I 10'-0' I I —Fill I I DINING ROOM B'-8' CLG. 11-2" 3'-811 G KITCHEN 8'-8' CLG. 5-SH FLEX 8'-8' CLG. 12-t' -4" �u men (2) 25-SH LIVING ROOM s'-V CLG. 3' -8' ARCH C' =� ' B V II ul "ill lily Q FOYER III V4 cLG. III III 3068 III W/10' III �\ tQnNe J u � �- LJ L• (2) 25-SH -11-61 'PORCH 8'-8' CLG. I ------'•------ '-411, 10'-0' V-4', MT. 5'-4" 1,'-4 27'-10" 1101 POST mlI 1 11 •8" 5'-4" STAIR DATA A 16 RISER S IB4' A 15 TREADS a 10' �u 25-SW BEDROOM #2 V-8' CLG. 3'-5' 9'-0" .y�" (2) 2068 B IR-ISH — — - 1 I V IC�7% BATH #2 / 8'-8' CLG. �►w (�Aw O x 2868 SC WJ-L 20 MIN. O GARAGE 8'-8' CLG 16'-0' X 7'-0' O.H. ------------- --- 19'-4" 20'-4' FIRST FLOOR PLAN SCALE: 1/4' ■ I'-O' 2'-IOI_L' -v N MASONRY/FRAME WALL LEGEND V-8' BLOCK WALL UN.O ON PLANS 55C%. HGT. VARIES 8' BLOCK WALL UN.O ON PLANS BRGs. INTERIOR LOAD BRCS. WALL U.N.O. ON PLANS 4' INTERIOR NON LOAD BRCS. WALL UN.O. ON PLANS -ALL INTERIOR DOORS TO BE 6'-8' -ALL EXTERIOR DOORS TO BE 6'-8' UNLESS NOTED OTHERWISE SQ.FT. CALL S IST FLR LIVING 2ND FLR LIvINrs 1104 1501 SQ. FT. SQ. FT. TOTAL LIvING GARAG>: COVERED LANAI PORCH 2605 431 80 III SQ. FT. SQ. FT. SQ. FT. SQ. FT. TOTAL 3233 SQ. FT, A/C VOLUME 21691.2 C0 F %8ff MD CLM=WID LQAO+3 BAWL WID E Mff FOR 8 SE=0 Q= OPEIGM AND TYPE SOUARE FOOTAQE 2Jw 0 WH WID IW IBIAW MIN. WINDOW 10 5 34/-45 CRITERIA EXTERIOR SWING 21 5 32/-42 DR MIN. CRITERIA S.G.D. MIN, 72 5 30/-3-1 CRITERIA 80i0 O.H.D. 56 5 30/-38 16010 O.H.D. 112 5 29/-35 SOFFIT N/A 5 31b/-38.8 ROOF TILE N/A 3 -6829/ IF -5829 APPLICABLE BASIC WIND SPEED MPH = 160 (Volt) INTERNAL PRESSURE COEFFICENT = t 0.18 BLDG. CAT.=II, EXP.=C, MEAN ROOF HT. = 15'-9" PRESSURES HAVE BEEN MODIFIED PER FBCR 6TH ED. (2017) R301.2.1 TO MEET TESTED ALLOWABLE OR NOMINAL WIND LOAD VALUES FROM THE PRODUCT MANUFACTURER. CANrRM DA79 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 F rA w ti w a F SVHDIY. da LOT: CREEKSIDE LOT 44 PROJECT 04321.000 044R1 MODEL 4EHB 0'2605-HAYDEN" C;ARAGE SWING: RIGHT PAGE: FIRST FLOOR PLAN 60 MPH EXP. C ARCHITECT DATE: 05/23/18 SCALE: 1/4"=1'— 0" SHEET Al 1' 4" \IF-G DBL. — TOP PLATF BAR DETAIL A SCALE: 1/4'=1'-0" I ARCH DTL. B SCALE: 1/2 = I'-0' ALT T TJ I SECURE TREADS TO STRINGER 1 j �J W/(3M 3' SCREWS • EA STRINGER, UNTHREADED SHANK TO EXTEND BEYOND THICKNESS OF SUB -FLOOR SHEATµING 42' H. 1/2 WALL W/ CAP / / L (2) LAYERS OF 3/4' PLYWOOD OR (2) LAYERS OF 3/4' SUB FLOOR MATERIAL RIPS FOR \ SOLID NAILING 42' H. HALF WALL W/ CAP 3/4' TtG SUB FLOOR GLUED 4 SCREWED PER FASTENER SCHEDULE 3/4' 2ND FIN. I=LR W-V BRCS. HGT. / J FLRTRUSSES 3/4' KICK / ST�ATIRS RISERS TO CONFORM TO FBCR 6TIH I' MAX. VO6�NCs PLATE / STAIR DATA: EDITION (20I1) MIN. TREAD•10' MAX. RISERP1 3/4' 3/16' I0' 16R ! 154' MAX. VARIATION IN RIMPAnREADS ADJACENT TO EACH OTHER 3/8MAX MA'+ MIN / 10 I NOSIi�k's VARIATION IN ANY RISER/TMAD HANDRAIL CIRCULAR GROSS SECTION D1A. TO BE 1 3/4' S T O R .-1/4' OR PROVIDE EQUIVALENT ERS- MIN, , WIDE IN • NARROW END MIN.NP W DTH o 12' NARROW END 34' MIN. HANDRAIL HGT. / 3-2x12 SYP STRINGER / REINFORCED W/2X4 S" W/CONT. BEAD OF NOTE- - SUB -FLOOR ADHESIVE •ENCLOSED ACCE8,811BLE SPACE UNDER PL-400 OR SIMILARE • STAIRS SHALL HAVE WALLS, UNDER STAIR EA HORIZONTAL RUN SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2' GYPSUM BOARDS. FBCR 302.1. 2 X 4 RE-INFORCING • EA. 2 X 12 STRINGER SECURE W/12d &'-S' O.C. MASONRY NAILS • 2X4 P.T. SLEEPER INTO SLAB WITHIN 8" OF EACH END, 32' O.C. MAX, STAIR SECTION HANDRAIL a 36' W/ 2X4 RE-INFOF CLEAR SPACE 5ETWEEN HANDRAIL AND THE WALL ALL 5E NO LESS THAN 1 1/2' PER F5CR R3111,B2 NOTE: 1. HANDRAILS SHALL HAVE EITHER A CIRCULAR CROSS SECTION WITH A DIAMETER OF Ii'± 2' OR A NONCIRCULAR CROSS SECTION WITH A PERIMETER DIMENSION OF AT LEAST 4" 5UT NOT MORE THAN 6 1/4' AND A LARGEST CROSS SECTION DIMENSION NOT EXCEEDING 2 1/4'. EDGES SHALL HAVE A MINIMUM RADIUS OF I/S'. 2. THIS RAILING SYSTEM IS DESIGNED TO RESIST A LOAD OF 50 PLF 0'-0' FIN FLR FOR A CONCENTRATED LOAD OF 200 POUNDS APPLIED IN ANY DIRECTION AT THE TOP OF SUCH BARRIERS AT ANY LOCATION ON THE SAFEGUARD, WHICHEVER CONDITION PRODUCES THE MAXIMUM STRESSES- PER SECTION 16010.1 / F.B.G. (2011) 6th EDITION, HANDRAIL SECTION _ 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com L AA #: 0003325 F N V W v Q W q F sysnrv. ee LOT: CREEKSIDE LOT 44 PROJECT* 04321.000 044R1 MODEL• 4EHB "2605-HAYDEN" GARAGE sTrING: RIGHT PACE: FLOOR PLAN SECTIONS / DETAILS 60 MPH EXP. C ARCHITECT STATE OF FLORIDA was D � 05/23/18 SCALE: 1/4"=1'-0" SHEET � I � not a, SECOND FLOOR PLAN SCALE: 1/4 - I'-V 1441 N. RONALD REAGAN BLVD LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com L AA #: 0003325 F W� Chi W O k W 4 E N S'UHDIV. & LOT: CREEKSIDE LOT 44 PROJECT6 04321.000 044R1 MODEL: 4EHB 012605-HAYDEN01 GARAGE STnNG: RIGHT PAGE: SECOND FLOOR PLAN 460 MPH EXP. ARCHTECT- STATE OF FLORIDA Y 9= a �: A AB%"ACRA NO 93723 rrcl" 05 23 18 DATE: / / SCALE: 1/4"=1'-0" Mw SHINGLE ROOF FYPON 16'X48' DECORATIVE SHUTTER OR EQUIVALENT 0-0" 2ND FLf2l 5RG. HGT. FYPON--- 5KTIIXIi OR EQUIVALENT 6' RAISED 15AND (TYP.) 10'-0 3/4" 2ND FLR FIN. FLRJBRG. PGT. 8'-0" BRCS. PGT.� m ENTRY I I I I 4B I I a I 4' RAISED TYP. I I SAND (TYP.) I 8' RAISED I I SAND (TYP.) I I 0'-0" FIN. FLR. -0'-4" GRADE IMINJ � I8'-0" 2ND FLR r _ 5R3. HCzT. I I I I I I I I I I I I I I I I I I 10'-0 3/4' 2ND FLI I FIN. FLRJ5RCa. HCsTR . - -- 8'-8' CLC. H-6T.,h I I -I -- I I I I 4B I I A3 I TYP. I I I I I I I I I I 0'-0" FIN. FLR. I I -0'- ' GRADE _4 -- IN: I FRONT ELEVATION SCALE: 1/4 ■ I'-0' TEXTURED FINISH NOTE: WALL FENESTRATION FLASHING AS PER F5CR R'103.4 OFF RIDGE VENT 12 - - - — - - - - •_'__ �r r- REAR ELEVATION SCALE: 1/4 = 1'-0' TEXTURED FINISH 2(o'-IS" BLD. HGT. IS'-S" 2ND FLR. — - SRCs. HGT. 4' RAISED BAND 6' RAISED BAND 110 -_0 3/4" 2ND FLR. FIN. FLR./BRG. HGT, 8'-S" GLG. HGT. OPT. COACH LIGHT 0'-0' FIN. FLR. _ -4° CsRADE (MIN.) 2ND FLR -0II 10'-0 3/4" 2ND FLR. - FIN. FLR/5RG. HGT. oa'-8' GLCs_ HGT. 0'-C' FIN. FLR. '- ° CxRAD t INJ MODEL 2605-HAYDEN-4EHB (2-Story) AREA OF ATTIC = 1541 SQ. FT. N ET FREE VENTI LATI ON AREA RI REQUIRED VENTILATION AREA 5.14 MIN. REQUIRED VENTILATION IN UPPER PORTION OF ATTIC OFF RIDGE VENTILATION AREA TOTAL# OF VENTS REQUIRED TOTAL# OF VENTS PROVIDED FFITVENTILATION AREA LINEAR FEET OF SOFFIT REQUIRI 1/ 300 = 1541 /300 5.14 SQ. FT. = 739.68 SQ. IN. A X 739.68 295.872 SQ. IN. (BALANCE TO BE PROVIDED IN SOFFIT VENTS) 115 SQ. IN. PER VENT (net free area) 2.57 3 7 SQ. IN. PER LINEAR FT (net free area) 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 F W W 0 W a Ems. SU'HDIV. 8a LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL: 4EHB "2605-HAYDEN" GARAGE 3TrMG: RIGHT PAGE: FRONT & REAR ELEVATION "H" 60 MPH EXP. C ARCHITECT: STATE OF FLORIDA y ROLAN a AD06CHACRA NO 93723 05 23 18 DATE., SCALE: 1/4"=11— 0" SHEET DOUN 'PON 11 OR `LENT 2ND FLR HGrtT_ 3/4" 2ND FLR. LRJ5RCs. 44GT. 5RCx. HG:T. rRY FIN. FLR. GxRADE (MIN.) LEFT TEXTURED FINISH ELEVATION RIGHT ELEVATION SCALE: 1/4 = V-0' TEXTURED FINISH 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 r4 W 19 LQ a N O y 4 F F: ti SVHDIV. de LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL: 4EHB "2605—HAYDEN" C3ARAGE STnNG: RIGHT PAGE: LEFT & RIGHT ELEVATION "H" L60 MPH EXP. ARCHITECT- STATE OF FLORIDA ND A ABOUCHACRA AR NO 93723 PRINT 05/23/181 SCALE: 1/4"=1'— 0" SHEET Ia P31-1 ELECTRICAL LEGEND SYM. DESCRIPTION -elf STANDARD SWITCH -WAY SWITCH -WAY SWITCI I DIMMER SWITCH HE PUSH BUTTON DISCONNECT TTHERMOSTAT SINGLE RECEPTACLE (125v/20-AMP SINGLE POLE) 110V DUPLEX RECEPTACLE 110V DUPLEX RECEPTACLE (EQUIPPED ITH GROUND FAULT NTERUPTER/TAMPER RESISTANT TYPE) 110V DUPLEX OUTLET (HALF OF OUTLET WIRED TO SWITCH) =99= EXTERIOR WATERPROOF/GFI RECEPTACLE (GROUND FAULT NTERUPTER) 110V QUADPLEX RECEPTACLE ® 110V DUPLEX RECEPTACLE (FLOOR OUNTED) 20V RECEPTACLE (4 WIRE ONNECTOR) I-(7 VALL MOUNTED LIGHT FILING MOUNTED LIGHT �} ENT LIGHTD LIGHT SCONCE PRE -WIRE k5UL5 Q.FAN WITH LIGHT (I CFM PER SFT.) AAA LIGHT FIXTURE BULB LICIT FIXTURE An>sanA6 BULB LIGHT FIXTURE " TRACK LIGHTING ATTIC LIGHT WITH PULL CHAIN JNPER CABINET LIGHT ® I'x4' FLUORESCENT LIGHT (RECESSED) ® 'x4' FLUORESCENT LIGHT (SURFACE OUNT) x4' FLUORESCENT LIGHT (RECESSED) e x Q RECESS LIGHT RECESS LIGHT (VAPOR PROOF) ILING MOUNTED LIGHT WITH J-BOX OPT. FAN LECTRICAL PANEL (FIELD VERIFY OCATION) LECTRiCAL METER (FIELD VERIFY OCATIM 1{j) -BOX (WALL MOUNTED) Q -BOX (CEILING MOUNTED) FILING MOUNTED FAN B VENT FAN (I CFM PER SQ. FT.) iQPHONE JACK Q SMOKE DETECTOR (CEILING MOUNTED) ® /GA OX D DETECTOR CEILING MOUNTED) HIMES ® II -Ill D OUTLETR GA OOR OPENER TV V JACK -� S5 PORT •N OCATION OF TV JACKS 4 PHONE OUTLETS 4 FANS TORE VERIFIED A HOMEOWNER PRE -CONSTRUCTION MEETING. • ALL RECEPTACLES IN ALL INHABITABLE ROOMS TO BE ARC FAULT PROTECTED PER NEC 210.12(b) • 20 AMP DEDICATED LAUNDRY CIRCUIT. • GFI * ISLAND (NOT ON KITCHEN CIRCUIT) • DISHWASHER DISCONNECT TO BE LOCKOUT IN PANEL • BATHROOM EXHAUST FAN TO HAVE MIN. CAPACITY OF 50 Cl INTERMITTENT PER TABLE MI50'1.4 OF F5CR 6T4 EDITION (2011), • LAUNDRY ROOM RECEPTACLE SHALL BE GROUND FAULT CIRCUIT-INTERUPPTER PROTECTION FOR PERSONNEL ON FEEDERS) • WIRING METHOD SHALL 5E NON METALLIC CABLE AS NEC 2014 ARTICLE 300WIl • ALL RECEPTACLE TO 5E TAMPER -RESISTANT TYPE • ALL LAMPS SHALL 5E SELECTED BY BUILDER AND Ito% OF LIGHTING MUST BE ENERGY EFFICIENT TYPE PER Fj5 - ENERGY CONSERVATION (RESIDENTIAL ENERGY EFFICIENCY) 201-16th EDITION R404.1 CEILING I LIGHT TO BE INSTALLED, PROVIDE J-BOX FOR OPT. FAN FOR VENT OR MICRO COVERED LANAI i l / Cam' `J \ 0 ROOM I / III I 7 a t Q ' KITCHEN �, GFI li PAN. OPT. I �F, GFI r r FLEX r/ J' �J PRE -WIRED CLG FAN WP GFI ROOM PRE -WIRED CLG FAN TWITCH IN / \ CABINET -OUTLET /TO 2ND FL. FOR DW SWITCH r i T t , GFI 10 44' APP. S® I WP � � •`.\ G'FP.B. FOR I � CHIMES I ' PORCH L— — — — — — — — R PRE -WIRED CLG FAN J J BDRM. #2 S.D. �- IAI 7 / `P$. FOR GARAGE DOOR 1 I t 1 \ KEYLESS FIXTURE GFI GARAGE DOOR PREWIRE GARAGE BATH #2 WH GFI 0 W 44' APP. BOLLARD AS Ii PER BLDG. CODE FIRST FLOOR ELECTRICAL PLAN SCALE: 1/4' = 1'-0' IRRIGATION OUTLET 45' APP. GFI I OPT. COACH LIGHT WP Panel MAIN -A PANEL: 8/16wp crt. breaker VOLTAGE: 120/240V-1Ph MAIN: 150An M.C.B FEEDER: 3-#1 CuTHWN & 1-#6 Cu (G) in 1 1/2" C. OR 3- #2/0 AL THWN & 1-#6 Cu (G) in 1 1/2" C. Wire Pole Bkr Description Watts Circuit Circuit Watts Description Bkr Pole Wire #12 1 20 Exterior Receptacle GFI for TUG 1200 1 2 1 ISpac8 #12 2 20 Irrigation Pump 1000 3 Ispace 5 6 6240 A/C C.U. 40 2 #8 Space 7 e PANEL -A PANEL: 42 crt. breaker VOLTAGE: 120 / 240 V -1Ph MAIN: 150 Amp M.L.O. FEEDER:3-#1 Cu THWN&1-#6Cu(G)in 11/2"C. OR 3-#2/OAL THWN&1-#6 Cu(G)in 11/2"C. Wire Pole Blur Description Watts Circuit Circuit Watts Description Bkr Pole Wire # 12 1 20 Small Appliance 1500 1 2 8000 Range 50 2 #6 # 12 1 20 Microwave / Hood GFI 1800 3 4 #12 1 20 Small Appliance 1500 5 6 4500 Water Heater 25 2 #10 # 12 1 20 Refrigerator 1500 7 6 # 12 1 20 Dining Receptacles AFCI 1500 9 10 1200 Disposal GFI 20 1 #12 #12 1 20 Bath GFI Receptacles 1200 11 12 1500 Dishwasher GFI 20 1 #12 #14 1 15 Foyer / Flex / Hall AFCI 900 13 14 5000 Dryer GFI 30 2 #10 #14 1 15 Uxng Rm, Lanai, Kitchen, Din. Lts AFCI 900 15 16 Space 17 1600 Washer GFi 20 1 #12 #14 1 15 SO & C/O AFCI 900 19 1000 Garage Door Opener GFI 20 1 #12 Space 21 1200 Garage Us & Receptacles GFI 20 1 #12 #14 1 15 Bedroom #2 / Bathroom #2 AFCI 900 23 K26 900 Owner's Suite AFCI 15 1 #14 #14 1 15 Bedroom #3 AFCI 900 25 900 Owner's Bathroom AFCI 15 1 #14 #14 1 15 Bedroom#4/Opt. Bed#5&#6/Opt. Loft AFCI 900 27 1200 2nd Poor Hal0STD2nd FL Ui Laun. AFCI 20 1 #12 #12 1 20 Exterior Lights and Recept GFI 1000 29 1000 Irrigation controls only 20 1 #12 Space 31 Space Space 33 34 Space Space 35 36 Space Space 37 38 Space #8 2 35 A/C A.H.U. (Heater 5 KVA at 65%) 5525 39 40 Space 41 42 Space Load subject to demand factor calculations / line 17600 27900 Load subject to demand factor calculations / line Demand Factor Calculations: ABBREVIATIONS: AFCI: ARC FAULT CIRCUIT INTERRUPTER INC: NON -COINCIDENT LOAD GFI: GROUND FAULT INTERRUPTER Total load subject to demand factor 45500 First 10000 watts at 100% 10000 Remaining watts at 40% 14200 Total A/C load 11765 LOAD CALCULATION IS BASED ON A/C NON -COINCIDENT LOAD Total Connected Load Watts 35965 Total Amps (watts 1240 wits) 149.9 General Lighting & Receptacle Load Total A/C Square Feet 2605 General Lts & Rec 3 W / Sq. Ft. 7815 Hi -Hats 3at 65W/Light at 100% 195 Total General Lights & Rec (Watts) 8010 Ckts# atts/Ck Total watts General Lts & Rec Panel A 11 728 8010 METER FIELD VERB IE50 ,AMI= ELECTfR1l fR15ER PROVIDE 302/0 CU, THWN + 106 CU IN 2' CONDUIT OR 3 04/0 AL, THWN + 1% CU IN 2' CONDUIT. (CONDUIT TO TERMINATE ABOVE SOFFIT a OVERHANG.) NOT TO SCALE. COMBINATION SERVICE DISCONNECT SWITCH AND GENERAL NOTES: M ELECTRIC METER IN A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL NEMA 31R ENCLOSURE COMPLY WITH ELECTRICAL PROVISIONS OF THE FBGR i EDITION (2017). LOCAL CODES, AND ALL LOCAL POWER COMPANY REQUIREMENTS. 150A/2P B. ALL CONDUCTORS SHALL BE TYPE THIHN/THU1N UNLESS MCB NOTED OTHERWISE. TELEPHONE SERVICE r ENTRANCE EQUIPMENT POWER COMPANY TRANSFORMER GRADE PROVIDE 150 AMP, 120/240 VOLT, I PHASE SECONDARY - ELECTRICAL SERVICE. PROVIDE 3 M COPPER (CU) IN 1-1/2" PIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3 02/0 ALUMINUM (AL) IN 2" DIA SCHEDULE 80 PVC CONDUIT UNLESS SERVICE IS PROVIDED BY THE ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC COMPANY PRIOR TO BID. INTERSYSTEM BONDING TERMINAL AT LOW VOLTAGE CONNECTIONS 150 AMP 120/240 VOLT 1 PHASE MLO PANEL CA5LE TELEVISION SERVICE ENTRANCE EQUIPMENT - 1 04 CU SERVICE GROUND CONNECTED TO CONCRETE ENCASED FOOTER STEEL PER ELECTRICAL PROVISIONS OF THE FBCR 6tH EDITION (201-1). 5/8" DIA X & FT LONG COPPER CLAD GROUND ROD 1441 N. RONALD REAGAN BLVD LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-7744078 www.abdosigngroup.com t AA #: 0003325 F U may.. IQ W Q r sVHDiV. 8a LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SVfMG: RIGHT PAGE: FIRST FLOOR ELECTRICAL PLAN 60 MPH EXP. jC rx�r r 05 23 18 DATE. SCATZ: 1/4"=1'—1 SHEET El CaEND SYM. DESCRIPTION STANDARD SWITCH 3-WAY 5WItGH 4-WAY SWITCH IMMER SWITCH i-0 SH BUTTON ISCONNEGT 7 tHERMOStAt � SINCsLE REGEP''1'AGLE (125v/!ID-AMP SINCSLE POLE) � IIIDY DUPLEX RECEPTACLE � IIIDY DUPLEX RECEPTACLE (EQLLIt"PED WITH CsROUND FAULT NTERLLPTER/TAMF'ER RESIStANT TYPE) � IIIDY DUPLEX o11tLEt (HALF OP OUTLEt (RED TO SWITCH) � EXTERIOR WAtERPROOF/CFI RECEPTACLE (CsROUND PAULt INTERLLPTER) IIIDY QLLADPLEX RECEPTACLE ® IIID��)EX RECEPTACLE lI�OOR � TIDY 14,ECEPTACLE (4 WIRE CONNECTOR) FQ WALL MOUNTED LICsHt GEILINU MOUNTED LICsHt F'ENDENt LIGHT LOOD LICsHT WALL SCONCE PRE -WIRE VENT PAN WttH LICsHT (I CFI`i PER SQ. FtJ �4 3 BULB LIGHT FIXTURE BULB LICE -It PIxtLLRE nnneen 6 BLLLB LIC�Ht FIXTURE 48' tRAGK LICsHTIN(s ATTIC LICsHT WITH PULL CHAIN � UNDER CABINET LICsHT ® I'x4' FLUORESCENT LICsHT (RECESSED) ® I1x4' FLUORESCENT LIGHT (SURFACE OUNT) 2'x4' FLUORESCENT LICsHt (RECESSED) ® x O BEDROOM #4 UPSTAIRS BEDROOM #5 '� LIVING I 30 PRGLWGI;p �PAN\ ` / f�RE-WIRED \ i CLG: FAN S.D. O 3a Z — LAUN. GFI �2 ,.----�� s/co� BATH#3�------------ -- -- LAI OPT. iOff, I 0 '� — J S/c WALL MOUNTED OCATION)_ _ _ LIGHT W/SWITCW IN ATTIC ' �� s �o� OWNER'S SUITE BEDROOM #3 OWNER'S , BATH \ F'RE-WIRED f'FE-WR(a''ED CLG FAN CLCs FAN m Y. 0 0 0 0 0 o o a \ o 0 I L — — — — J SECOND FLOOR ELECTRICAL SCALE: 1/4' ® I'-& I ELECtRIG�4L LAW 17>7 E IRE PLAN - TYPE PER P$.G. ENERGY CONSERVATION 1441 N. RONALD REAGAN Bl LONGWOOD, FL 32750 PH: 407-7746478 FAX: 407-774-4078 www.abdesigngroup.com l AA #: 0003325 KEN SUB tQa W may.. 0 W q E ac LAT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 asonEL: 4EHB "2605-HAYDEN" GARAGE a9'VYINCi: RIGHT PAQrR• SECOND FLOOR ELECTRICAL PLAN 60 MPH EXP. PRINT SEiMET 05/23/18 1441 N. RONALD REAGAN Bl LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 E W h V W may.. O W 4 E F StJBDIV. & LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL• 4EHB "2605-HAYDEN" GARAGE SWING: RIGHT PAGE: PLUMBING PLAN 460 MPH EXP. C D TE 05/23/18 SCALE: 1/4"=1'-0" SHEET Pi COVERED LANAI 0 0 DINING ROOM 10X6I120 CFM 016 KITCHEN Oo OI --'I 1imx6 `• ; 120 `.% 4 1mX6 120 GFM IV, FLEX WIM SX4I45 CFM 12x8 PASS �}}{� THRU III FOYER III III LIVING ROOM 4' I 10X6 PASS 120 GFM THRU j II I i I I I I Ip II I I I I I I I01 I I I I I I Iml I BEDROOM2 w 7r HAYDEN EQUIPMENT SCHEDULE 4 TONS MF!s CARRIER Cu 0 0 0 o 0• IU FX4DN(5,F)043L HEAT 5KLU SEER 15 SEER TOTAL CAP 4500 PORCH ELECTRIC 208/230/IPH BRKR CU 40 AHU 35 ------------------ Ell REF LINES L- - - -- _ E FIRST FLOOR HVAC PLAN pl;N U W may.. 0 w a F 4 h SVHDIV. 8e LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SVr MC;: RIGHT PAGE: FIRST FLOOR H VAC PLAN 160 MPH EXP. DATE: UU/ r-o1 to SCALE: 1/4"=11— 0" SHEET i � — —— J SECOND FLOOR HVAC PLAN F W V 4 y q h O SUHDIV. de LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL: 4EHB "2605-HAYDEN" GARAGE STIYING: RIGHT PAGE: SECOND FLOOR HVAC PLAN L60 MPH EXP. C `z,&`z' + DATE: 05 23 18 SCALE: 1/4"=1'-0" WIN 2X4 TOP PLATE PER F PLAN PRE-FAB TRUSS 1/2' CLCs. BOARD Vt' THICK 2 COAT PORTLAND CEMtN1 CORNER BEAD PLASTER APPLIED DII�CIL7 rY S' SEE NOTE: STUDS IN MASONRY %IC STRUCTURALFOR REI�Nt PARTITIONS SUPPORTING :. ... ... . . ... .. ,. ..:., .. ... _:. . _:� ....., Tofu P.T. wD 1/2' DRYWALL WALL HUNG FLUM51NG CA" AND SEAL CELL �+E4S rER FILL FIXTURES AND WALL 1OA- CABINETS SHALL BE NOT Cs"LIM Rya SEALANT LESS THAN 2x4, WHERE I;'PW— SLIMYrrORCIASLIM VINYL WEATHER SPACED NOT MORE I' + STRIP MOULDING ALL AROUND 2X4 WOOD STUDS 024' THAN 16' O.G. OR, NOT -�----_WOW cam SA W. SASS �„ s.� K BRACNETS �'.C. LESS THAN 2x(.o, WHERE FAB Tr w000 J SPACED NOT MORE g VERncaL rl¢Aac APPROVAL REO. 6Y MAUF. MIN. DOOR B7 OTHERS THAN 24' O.G. as �- S FASTENED t0 SLIDE TRACK DRACKETB� CONC. SLAB "° W/ PRODUCT � APPROVALREa FIN. FLR. FOR R S IZE AN5AD BAR QUAINTI' GAS LINE THRU BLOCK GARAGE DOOR JAMBS D1 SCALE: 1 1/2'= 1'- 0' D1 SCALEi"''"°' 1 TYP. INT. WALL NON—BRG. D 1 SCALE: 3/4' = I'-0' FIBEW31-ASS SHINGLES 2x SLOCKINGs BETWEEN TRUSSES OVER W FELT PAPER OR PER STRUCTURAL DETAILS FIBERGLASS SHINGLES SYNTHETIC PRODUCT, OVER So FELT PAPER INSTALLED PER F5CR F15ERGLASS SHINGLES FIBER:sLASS SHINGLES OR SYNTHETIC R905.1.1 ON i' OS.B OVER 030 FELT PAPER OR. OVER 030 FELT PAPER PRODUCT, INSTALLED SHEATHING: OR J' COX SYNTH TIC SYNTHETIC PRODUCT, OR SYNTHETIC PER FBCR R905.1.1 ON PLYWOOD SECURED PER PER FBCR TAL1}' PRODUCT, INSTALLED OS.B. SHEATHINGS OR �' FASTENER SCHEDULE R905.1.1 ON ON OS.B. PER FBCR RS05.1.1 ON 1} COX PLYWOOD STIFF5ACK AT ALL UPRIGHTS SHEATHING OR GDX OS.5. SHEATHINGS OR i' 5/8' GYPSUM BOARD SECURED PER PER STRUCTURAL DETAILS PLYWOOD SECURED PER COX PLYWOOD OR 1/2' HIGH FASTENER SCHEDULE 1 0" PRE-ENGS WD. TRUSS SCHEDULE I m FASTENERDRIP SECURED PER STRENGSTH CLGS. TYP. TYP. EDGE FASTENER SCHEDULE 50ARD � REFERENCE O.H. MTL. DRIP EDGE � O.H. 2x FASCIA PER x ` VATI lr STRUCTURAL 2x FASCIA PER �' PER ELEVATION ELEVATIONS I ENERGYRM SEE CODE FOS FOR Aff ELEVAtION5 CONT. 2x RAT RUN SEC: PRE -ENDS TRUSS INSULATION R-VALUES PRE-ENCS TRUSS\JO VENTED SOFFIT PER STRUCTURAL DETAILS VENTED SOFFIT MTL. DRIP EDGE REFERENCE STRUCTURAL MTL. DRIP EDGEPRE-ENCs. CSASLE TRUSS SEE ENERGY CODE SULATION R-VALU PRE-ENCs. GSABLE TRUSS 1, O„ PER ELEVATION WEEP SCREED jkPER IELEVAX WEEP SCREED 2x4 OR 2x6 FASCIA PER TYp 2x4 OR 2x6 FASCIA PER ELEVATIONS O,N, ELEVATIONS 2x P.T. SECURED PER 5/8' PSUM P.T. SECURED VENTED SOFFIT R-4.1 INSULATION VENTED SOFFIT STRUCTURAL DETAILS HICsH S NCSTH ARD STRUCTURAL DET2x AILS WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS -4.1 IN ATION 1/2' THICK, 2 COAT REFERENCE WI A CEMENT AS PER PORTLAND CEMENT STRUCTURAL A ACT S SPECIFICATIONS PLASTER APPLIED DIRECTLY TO MASONRY FEE RENG Ix2 P.T. FURRINGTRUCTURAL STRIPS 4P 16' OC. 1/2' THICK, 2 COAT PORTLAND Ix2 P.T. FURRING CEMENT PLASTER APPLIED STRIPS I® 24' Off. 1/2' THICK, 2 COAT PORTLAND DIRECTLY TO MASONRY 1/2' THICK, 2 COAT 1/2' GsYP. WL. 50. CEMENT PLASTER APPLIED BD. PORTLAND CEMENT WOOD BASE , 8 CMU DIRECTLY TO MASONRY WOOD SASE — PLASTER APPLIED DIRECTLY TO MASONRY 0'-0' FIN. FLR. _ If 0'-0' FM. FOR. 0'-0' FIN. FLR — AI, 0'-0' FIN. FLR s' CMU a a � 8 a _ d d L a O d d O 5 pa a d W OW OPENING � TYP. WIND WALL SECTION W WINDOW OPENING TYP. WAL SECTION A A B I\ NO OPENINCz NOTE: NO OPENINGS PER FBCR 9m5.1.1 - FOR ROOF TO LESS THAN 4-12, A 2:IUNDERLAYMENT 4 1—STORY HIP BLOCK WALL (2 AYERSLOPES SYSTEM 5 1—STORY GABLE BLOCK WALL D1 SCALE: 3/4'=I'-O' 15 REQUIRED. FOR ROOF SLOPES D1 SCALE: 3/4'-1'-0' OF 4:12 OR GREATER, (1) LAYER UNDERLAYMENT IS PERMITTED BUT MUST BE PER ASTM D226 TYPE 11, ASTM D 4869 TYPE IV, OR ASTM D 6rt5� 1441 N. RONALD REAGAN BLVD LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 1rL a w a Cam. mow SUHDIV. ae LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL• 4EHB "2605—HAYDEN" GARAGE SIYINC}: RIGHT PAGE: DETAILS 60 MPH EXP. C ARCHITECT: STATE OF FLORIDA D TEE: 05/23/18 SCALE: 1/40"=1'-0" SHEET FIBERGLASS SHINGLES OVER W FELT PAPER OR SYNTHETIC PRODUCT, INSTALLED PER F5CR RW5.1.1 ON OS.5. SHEATHING OR COX PLYWOOD SECURED PER FASTENER SCHEDULE PRE-ENG WD.TRUSS--- 24' O.C. MAX. METAL DRIP EDGE 2x4 OR 2x6 FASCIA PER ELEVATIONS VENTED - SOFFIT REFERENCE - STRUCTURAL 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY IX2 FIRE -STOP SEE STRUCTURAL IX2 FIRE -STOP 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY IX2 FIRE -STOP DER LEVATM R-30 INSULATION PER ENERGY (/ GORE FORM. 0 5/8' GYPSUM 50ARD fYf'. OR 1/2' HIGH STRENGTH CLG. 50ARD Ix2 FIRE -STOP -4.1 INSUL. 0 i= 4 Lu A w WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS STRUCTURAL 3/4' T 4 G SUBFLOOR GLUED AND NAILED AS PER NAILING SCHEDULE !w R LEVAtION R LEVAtION FIBERGLASS SHINGLES OVER 030 FELT PAPER OR SYNTHETIC PRODUCT, INSTALLED PER F5CR R905.1.1 ON O.S.E. SHEATHING OR CDX PLYWOOD SECURED PER FASTENER SCHEDULE PRE-ENG WD.TRUSS — 24' O.G. MAX. METAL DRIP EDGE 2x4 OR 2x6 FASCIA PER ELEVATIONS SOFFIT REFERENCE - STRUCTURAL 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY IX2 FIRE -STOP SEE STRUCTURAL 5/8' GYPSUM BOARD OR 1/2' HIGH STRENGTH GLG. BOARD R LEVATION 1X2 FIRE -STOP R-4.1 INSUL. WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS -REFERENCE STRUCTURAL Ix2 P.T. FURRING STRIPS w 24' O.G. 8' CMU 1/2' GYP. WL. ED. WOOD EASE 4 G , Q 4 a a a 1/2' THICK 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY IX2 FIRE -STOP aim '% -..FORM. a 0 _ _'_INSULATION ENE =0 a s — _0:. Bp/121M : OR 1/2' PIGI-I STRENGTH CLG. 50ARV —pp Ix2 FIRS-STOF M `4--R-4.1INSUL. z 0 Q w w a N 0 ..- NAILED AS PER NAILING SCHEDULE Sam a= ®®�-150/81 GYPSUM 5. R. OR 1/2' HIGH STRENGTH Cl-G. IBOARD R-4.1 INSUL. w H wly �yIx2 — STRIPS a, CMU a 4� I A W/ WINDOW OPENING 1B WITHOUT WINDOW OPENING 2—STORY FIRST FLOOR BLOCK SECOND FLOOR BLOCK 1441 N. RONALD REAGAN 13L LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 0404 W �C U rw Is q A E 9VHDIV. 6e LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL: 4EHB "2605—HAYDEN01 GARAGE SVrMG: RIGHT PAGE: DETAILS L60 MPH EXP.JC ARCHRECT- STATE OF FLOON rsua.� i 05 23 18 DATE: SCALE: 1/4"=1'-0" 1 MIN. TO BLK W/ (2))i'X8' A -BOLTS 4' EMBEDMENT MIN. 4SHER AND NUT SPACED EVENLY FROM FLOOR TO OR WPM IN JOINTS PRIOR TO FILLIWA,C - 0 0 o ❑ SECURE 2x4 ONy o FLAT TO BLK W/ CUT NAILS. SIDES: 2X6 GARAGE DOOR SUCK W/ (5) 19 UV 2'X2'X)L WAAWER AND NUT t MIN o SPACED EVENLY FROM FLOOR TO GARAGE DOOR HDR IN JOINTS PRIOR TO FILLING. 1-2X6 PT 5LOCK • CENTER OF DOOR HEADER W/(I)VX0' J-BOLTS 0 4' EMBEDMENT W/ 2'X2'X%" WASHER AND NUT. o Ll,,,.rc. I IR MANUFACTURER'S INSTALLATION INSTRUCTIONS WHERE SUCH INSTRUCTIONS ARE MORE STRINGENT GARAGE DOOR BUCK ATTACHMENT 3 ecALs, im•r-r CMU OR I'X2' P.T. NAILER Ix4 P.T. OR %'X4' MIN. ❑ SECURE THRU FRAME 4 EXTEND I-Y4' INTO BLOCK q W/ W&' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1-Y4' WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING \-DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4) DOOR JAMB TO BLOCK +3/4 OR +5/4 TWINDOW TO BLACK +3 4 OR +5 4 A SCALE. N.T.S. 2X4: SECURE t0 BLOCK W/' TAPCONS OR (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4') WITHIN 8- OF EACH END 4 18' O.C. MAX SPACING, 2X6:® SECURE TO BLOCK W/2-%' TAPCONS(MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 149 - WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING. 2X8: cow SECURE TO BLOCK W/2-34- TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4) WITHIN 8' OF EACH END IS' O.C. MAX SPACING. 2X4 SECURE TO BLOCK W/ TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y41) WITHIN 8' OF EACH END < NOTE: STRUCTURAL 2X IS' O.C. MAX SPACING. MUST BE ON OUTSIDE 4 2X6= SECURED THROUGH SECURE TO BLOCK W/2--Wi' NON-STRUCTURAL TAPCONS TAPCON MIN. I-Y4' (MIN. SHANK SIZE J45 EMBEDMENT INTO BLOCK MIN. HEAD SIZE 300 8' CMU MIN. EMBEDMENT 1 Y4') ' DRYWALL WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 1'X4' OR I'X2' P.T. NAILER ® 2XS: ❑ SECURE TO BLOCK W/2-%l S.B. X 4' MIN. TAPCONS (MIN. SHANK SIZE .145 DOOR CASING MIN. HEAD SIZE 300 DOOR JAMOR WINDOW B MIN. EMBEDMENT 1,1441) ATTACH TO 2X PER WITHIN 8' OF EACH END MANUFACTURES DETAILS. 16' O.G. MAX SPACING. NOTE. SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED )14') DOOR JAMB TO BLOCK +1-15 18" WINDOW TO BLACK +1-15/ 8" C SCALE: N.T.S. 2X4:® SECURE TO BLOCK W/ V TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y49 WITHIN 8' OF EACH END 4 NOTE. STRUCTURAL 2X 18' O.G. MAX SPACING. MUST BE ON OUTSIDE 4 2X6cm SECURED THROUGH SECURE TO BLOCK W/2-W6' NON-STRUCTURAL �(6 TAPCONS TAPCON MIN. I Y4' (MIN. SHANK SIZE .145 EMBEDMENT INTO BLOCK MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') S' CMU WITHIN 8' OF EACH END 4 8, CMU X' 1�' DRYWALL IS' O.G. MAX SPACING. DRYWALL I'X4' OR I-X2- P.T. NAILER ❑ 2X8�1 I'X4' OR 1'X2' P.T.NAILER a OOR CASING OOR CASING SECURE TO BLOCK W/2-%l TAPCONS rATTACP W— (MIN. SHANK SIZE .145 OOR JAMB OR WINDOW MIN. HEAD SIZE 300 DOOR JAMB OR WINDOW TO 2X PER MIN. EMBEDMENT I Y49 1 ATTACH t0 2X PER MANUFACTURES DETAILS. WITHIN 8' OF EACH END E MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4') DOOR JAMB TO BLACK +1-1 2" WINDOW TO BLACK +1-1 2" SCALE: N.T.S. IS' O.C. MAX SPACING. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4) DOOR JAMB TO BLACK +2 1/4" WINDOW TO BLACK +2 1 4" D SCALE: 2X4= SECURE TO BLOCK W/ V TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') NOTE: STRUCTURAL 2X WITHIN 8 OF EACH END MUST BE ON OUTSIDE 4 IS O.C. MAX SPACING. 2X6 SECURED THROUGH SECURE TO BLOCK W/2-3(6.NON-STRUCTURAL VTAPCON MIN. 1 Y4' (MIN. SHANK SIZE .145 TCONS EMBEDMENT INTO BLOCK MIN. HEAD SIZE 300 8' CMU MIN. EMBEDMENT I Ya') XJ' DRYWALL WITHIN 8' OF EACH END 4 ❑ I'X4' OR I'X2' P.T. NAILER IS' O.G. MAX SPACING. 2X8cm SECURE TO BLOCK W/2-%l TAPCONS (DOOR CASING (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') DOOR JAMIS OR WINDOW WITHIN 8' OF EACH END < ATTACH TO 2X PER IS' O.G. MAX SPACING. MANUFACTURES DETAILS. Note. 64" AS NEeMo to M-" J00 !oo Not emop?49 DOOR JAMB TO BLACK +3" WINDOW TO BLOCK +3" E SCALE: N.TS. 2X4= SECURE TO BLOCK W/ 3(6' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4) WITHIN S' OF EACH END 4 NOTE: STRUCTURAL 2X 18' O.G. MAX SPACING. MUST SE ON OUTSIDE 4 2X6:® SECURED THROUGH SECURE TO BLOCK W/2-V NON-STRUCTURAL V TAPCONS(MIN. SHANK SIZE TAPCON MIN. I44' .145 EMBEDMENT INTO BLOCK. MIN. HEAD SIZE 300 MIN. EMBEDMENT I Ya') S CMU WITHIN 8' OF EACH END 4 1i' 18' O.G. MAX SPACING. DRYWALL 2X8:® I'X4' OR I'X2' P.T. NAILER SECURE TO BLOCK W/2-�(r,' 2ND 2X SECURE TO TAPCONS(MIN. SHANK SIZE S' R4ICTU ,,L MEMBER 145 W/(2N2d WITHIN 8' OF EACH MIN, HEAD SIZE 300 END t 6' t0 8' OC. MAX MIN. EMBEDMENT 1,44) OOR CASING WITHIN W OF EACH END 4 DOOR JAMB OR WINDOW 18' O.C. MAX SPACING. ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4') DOOR JAMB TO BLACK +3" /� WINDOW TO BLACK +3' SCALE: NTS. 2X4= SECURE TO BLOCK W/Y4' TAPCONS(MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4) NOTE: STRUCTURAL 2X WITHIN S' OF EACH END 4 MUST BE ON OUTSIDE 4 IS' O.C. MAX SPACING. SECURED THROUGH 2X6:® NON-STRUCTURAL W6 SECURE TO BLOCK W/1-1/4' TAPCON MIN. 1-Y4' TAPCONS(MIN. SHANK SIZE EMBEDMENT INTO BLOCK .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y49 S' CMU WITHIN 8' OF EACH END 4 1 DRYWALL IS' OZ. MAX SPACING. I'X4' OR 1'X2' P.T. NAILER 2XS� SECURE TO BLOCK W/1-1/4' 3' CSS, X 4' MIN. TAPCONS (MIN. SHANK SIZE .145 DOOR CASING MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') DOOR JAMB OR WINDOW WITHIN W OF EACH END 4 ATTACH TO 2X PER 18' OZ. MAX SPACING. MANUFACTURES DETAILS. Nom S4" AS Noom to PI." JAt7li mo Not �DP Pw DOOR JAMB TO BLACK +3-7/16" WINDOW TO BLOCK +3-7/16" G SCALE: N.TS. 2X4-m SECURE TO BLOCK W/Y4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y49 WITHIN 8 OF EACH END 4 NOTE: STRUCTURAL 2X IS OZ. MAX SPACING. MUST BE ON OUTSIDE 4 2X6 SECURED THROUGH SECURE TO BLOCK WA-I/4- NON-STRUCTURAL 3(e TAPCONS TAPCON MIN. I-Y4- (MIN. SHANK SIZE J45 EMBEDMENT INTO BLOCK MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') 8' CMU WITHIN 8' OF EACH END 4 V DRYWALL 18' O.C. MAX SPACING. ❑ I'X4' OR I'X2' P.T. NAILER 2X8=m SECURE t0 BLOCK W/1-1/4' - P.T. X 4- MIN. TAPCONS OOR CASING (MIN. SHANK SIZE .145 MIN. HEAD 00 SIZE 3 MIN. EMBEDMENT I Y49 DOOR JAMB OR WINDOW WITHIN 8' OF EACH END 4 TTACW TO 2X PER IS' O.C. MAX SPACING, MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4-) DOOR JAMB TO BLACK +3 3/4" %u1 WINDOW TO BLACK +3 3/4" i'' SCALE: N.tS. 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com L AA #: 0003325 F h V W O W q h h st7]3 LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWMG: RIGHT PAGE: DETAILS 60 MPH EXP. C DARTS: 05/23/18 SCALD: 1/4"=11— 0" m Building Permit # Planning & Development Services Department Building & Regulations Division Product Review Affidavit Owners Name Applicant Product Opening Design Product Rated Manufacturer Model # Product Approval Glass Type Method of Attachment Pressure Design Pressure Number 1/4" concrete screw 6" edge distance @ head, 4" edge Swing door (+36 ) / ( -47 ) (+67) / (-67) Therma-Tru Smooth Star FL20461.17 N/A distance @ jamb, 4" each side of transom centerline to bucking. Fastener spacing @ 15" o/c max. @ head and jamb. Min. embedment of all anchors to be 1 1/4" Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from corners, 11 3/4" o/c at jamb, 16" @ head. 1 1/4" embedment. Type II: 3/16" or 1/4" ITW concrete tapcon SH Window (+38) / (-48) (+50) / (-50) Ply Gem Ply Gem 1500 FL16103.1-R9 Non impact anchor. 6" max. from corners, 7 1/4" o/c at jamb, 10 1/4" @ head. 1 1/4" embedment. Two additional tapcons midspan and one at lower frame required vertically each side. Install per manufacturers recommended requirements. Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from corners, 14" o/c at jamb, 10" @ head. 1 1/4" embedment. Type II: 3/16" or 1/4" ITW concrete tapcon anchor. 6" max. SH Window (Integral (+38) / (-48) (+50) / (-55) Ply Gem Ply Gem 1500 FL16100.1-R6 Non Impact from corners, 8 1/2" o/c at jamb, 6" @ head. 1 1/4" Mulled embedment. Eight additional tapcons top and bottom required horitontally, one midspan vertically each side. Install per manufacturers recommended requirements. 1/4" concrete tapcon anchor. 2 1/2" minimum edge Sliding Glass Door (+33 ) / (-41) (+50 ) / (-50) Ply Gem Builders Series FL14634.2-R3 Non Impact distance. 6" max o/c from corners and 20 3/4" max o/c 4780 elsewhere top, vertically and bottom. 2 1/2" min embedment. 1/4" concrete tapcon anchor. 6" max o/c for corners. Tapcon required 3" each side of center of opening top and Opaque single door (+36) / (-47) (+47) / (-47) Therma-Tru Smooth Star FL14985.1-R2 N/A bottom. To and bottom centerline of each door slab et p g with transom tapcon. Rest of vertical o/c spacing is 14 max. 1 1/4 embedment. 3/8" x 2-3/4" Hilti sleeve anchors 6" from ends 22" O/C Double Garage Door (+29) / (-35 +46 () (-42) / Clopay 16.2x7 73 W6 FL16546.6-R9 N/A Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" dia. heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per Roof IKO Cambridge FL7006.1-R10 shingle placed 6-1/8" above the butt edge, approx. 1" and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. Miami -Dade approved corrosion resistant tin -caps and 12 Underlayment Intenurap RhinoRoof U20 FL15216.1-R3 gauge 1 %" annular ring -shank nails, spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. in the field of the roll Soffit +31.6, -38.8 (+157) / (-46.1) PlyGem Variform Soffits FL24161.1 1/4" x 20 stainless steel or ELCO Panelmate with minimum Hurricane Panels Hurricane Storm embedment @ 1 3/4" in concrete / masonry, 2 1/2" min. Less than 6' span (+47) / (-53) panel MFG. 24 GAGE FL16293 R2 edge distance, 12" o/c max. spacing. Can be headed screw or all thread but with wing nuts. 1/4" x 20 stainless steel or ELCO Panelmate with minimum Hurricane Panels 6' Hurricane Storm embedment @ 1 3/4" in concrete / masonry, 2 1/2" min. span or more (+45) / (-50) panel MFG. 24 GAGE FL16293 R2 edge distance, 12" o/c max. spacing. Can be headed screw or all thread but with wing nuts. Zip System Install per manufacturers recommended requirements. Sheathing Huber Wall Sheathing 17147-R2 1441 N. RONALD REAGAN BLVD LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 l www.abdesigngroup.com AA #: 0003325 i F W v w 0 a F q ti SU393DIV. de LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWING: RIGHT PAGE: PRODUCT APPROVALS 60 MPH EXP. C DAINT TE:: 05/23/18 SCALE: 1/4"=1'— 0" SHEET NOTE: NOTE: IF ZIP SHEATHING SYSTEM IS APPROVED BUILDING WRAP IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE SHALL BE LAPPED A MINIMUM OF INSTALLED, PLEASE SEE 4'x4' SELF -ADHERING MEMBRANE 6 6' • VERTICAL LAPS (ROLL FLASHING (COMPATIBLE W/ HOUSE MANUFACTURERS ENDS) A 6' w HORIZONTAL LAPS. MANUFACTURERS WRAP MATERIAL) OVER INSTALLATION PROCEDURES ALL SEAMS NEED TO BE TAPED LATH VERTICAL LAP TO BE I' INSTALLATION PROCEDURES APPROVED HOUSE WRAP. WITH FORTIBER SHEATHING TAPE FLASHING TO EMEND ONTO PIPE / P OR LESS PIPE PR:FORMED CONTROL JOINT \ PLASTER 3 COAT CEMENT PENETRATION r-LAs SELF -A mPATe MEMBRANE FLASHING (COMPATIBLE W/ HOUSE � WRAP MATERIAL) OVER 4 x4 FLANGE OF CONTROL JOINTS T / \ SELF -ADHERING MEMBRANE BE WIRED TIED TO LATH • 9' WRB LAYER 42, FORTIP15ER FLASHING OVER APPROVED O.C. MAX (VERT-). NOTE: DO BUILDING PAPER HOUSE WRAP. NOT FASTEN CONTROL JOINT TO / r MIN LAP •METAL LATH \ FLASHING TO EXTEND ONTO PIPE WALL EVEN IF STUD EXISTS BEYOND EXCEPT STAPLES W/ APPROVED METAL LATH W LEG MAY BE USED TO TEMP. FASTENED *1' (VERTU O.C. MAX X X X I SECURE CONTROL JOINT AT SUPPORTS X X X — DURMG INSTALLATION WIRE, LAYER M CUT AND OVERLAP ONE SIDE OF METAL LATH FLASHISELF-NG DHERINCs MEMBRANE CUT AND OVERLAP ONE SIDE OF FLASHING FASTENERS MAXI BE p * SELF -ADHERING MEMBRANE • 1. O.G. X VERTICALLY WOOD SHEATHING I MEP I STEP "2 FLASHING ' THICK 3 GOAT CEMENT OR t/Ib' ZIP SHEATHING �' WRB LAYER h, I PLASTER STUCCO WRAP SYSTEM TALLIED PER V , STUCCO WRAP METAL LATH r MANIF Co.) b' MIN PAPER LAP BELOW ONLY / I Ff WRB LAYER •2, PORTIMBER WRB LAYER •2, FORTIFIBER WQB LAYER P FORTIFIBER BUILDING PAPER BUILDING PAPER METAL LAN PER STUCCO WRAP FLASHING OVER RING MEMBRANE To I INSTALL FASTENERS (CLIPS, FLASHI G-% OVER MEMBRANE LATH SHALL NOT GAP MIN. FHOUSE WRAP. LASHING OVER APPROVED b ro a b' To b' b�ASHEATHING STRAPS, STAPLES) SE ) AS FLASHING TO EXTEND ONTO PIPE TBe C4NTNU"HROUGH CONTROL MIN. MIN. ,! 0 Olt"�GSALLIED PIER REQUIRED TO SECURE JOINTS BUT SHALL // 11 PIPE/ WIRE TO FRAMING �„ a4 ,I ay a : 4'x4' SELF-AD4{ERI MEMBRANE BE STOPPED AND FLASHING OVER APPROVED TIED At EACH SIDE. PROVIDE 2X4 BLOCKING r MIN LATH F �I �70 EXTEND ONTO PN� PER ASTM CI063 PLACED FLAT MAX 6' TO S' LAAPLL'LOVER 1.Im.IrF /FROM CONAP TROL JOINT FALLS WHEN OI'U 2 APER LAP 36' CONT. BEAD OF SEALANT STRUCTURAL SCUD SCALE: I V2*nI'-m' 1. FASTENERS FOR LATH TO BE NAILS OR / INSTALL APPROVED HOUSEWRAP AIR STAPLES IN COMPLIANCE W/ ASTM C1063 INFILTRATION BARRIER OVER 2. WIRE TIES TO BE (NO. IS) m1a415' WIRE / i 3. BLOCKING SHOWN MAY BE IN ADDITI \ ELASTOMERIC COATING OVER STUCCO/ TO WALL STUDS REQUIRED PER PLAN G.V. FINISH (SEE TYP WALL SECTION) VERTICAL LATH & PAPER DETAIL WOOD STUDS SECTION PER SECTION R703.7 I'WI Exterior lathing and plastering NOTE: SHEATHI Exterior use of portland cement plaster SILAPS OF METAL OR 1/16' ZIP SHEATHING SYSTIEM t: shall Comply with the application PLASTER BASES SHALL (INSTALLED PER MANW. SPIECSJ a;; requirements of ASTM C 926-12A. BE SECURED TO BUILDING NOTE: 6' MIN. Installation of exterior lathing and framing INSTALLED, PLEASE SEE shall Comply with ASTM C 1063-12A. 1 „ FRAMING MEMBERS. PAPER 3 LAP IF ZIP SHEATHING SYSTEM IS s s O M TYPE CONTROL JOINT THEY SHALL BE TIED BETWEEN SUPPORTS WITH 00415-IN. 021-MM) STUCCO AV LAP • LATH MANUFACTURERS WIRE AT INTERVALS NOT ,3 a' LAP • PAPER INSTALLATION PROCEDURES MORE THAN 9' (229-MM). L FOLD Iw01110 • Pr. A O L POLO INWARD • Pr. A APER ABTA GIm63 . •..3 PIPE PENETRATION DETAIL C F R>�t I' E �•.•/ Z CREASE • PT. NOTE: ®FOLD ® 4 KIC KO UT FOR REPAIR OF TEARS HORIZONTAL LATH N.T.S. IN WR5 LAYERS, DETAIL MAY BE IDATCHED TEARS & PAPER DETAIL W440UW WRAP TAPE PER MANUF. SPEC. OR �D PEEL 4 STICK • 48 ® '1/16' ZIP SHEATHING SYSTEM ( INSTALLED PER MANUF. SPECS.) OR O1. FOLD WOOD SHEATHING OR CMU INwa� • CREASE®2. "PT" PT 5 A WRB LAYERI, 2. CREASE • PT. 5 3 • PT STUCCO WRAP (FRAME ONLY) 3. CRaA6E • PT. G 4. FCLD FT. G OVER PT. 5 TILL PT. C TOUCI-E6 BDTroMFLANGE THICK, 3 COAT CEMENT ® PLASTER (FRAME), 1/2' 2 COAT P I, CEMENT PLASTER (GMU)at LEGEND nO METAL LATH (FRAME ONL*0 LAP wRa 4 TAPE OVER DRAINAGE PLANE NA5 ®� FLANGE ROOF/WALL SCREED LAYER #1, J-CUCCiO WRAP) "TETrAw NOTE: WA- FOLD. M e� D. 22 IF ZIP SHEATHING SYSTEM IS , THICK 3 GOAT CEMENT �� 5"X5" 'L' TYPE CONTINUOUS INSTALLED, PLEASE SEE WR5 LAYER *2 (FORTIF18ER - - - - - - PLASTER�PRa'tE, ra' � coAr � -� GALV. METAL FLASHING MANUFACTURERS CSMIENT M-ASTM (CM) Z INSTALLATION PROCEDURES uAcaB LAYER 4, FORTIFIHIER ;� (NAIL TO ROOF DECK, NOT 5U I L D I NG PAPER) BUILDING PAPER IFRAME ONLY) WALL SHEATHING) ulna LAYER a, N — CAP SHINGLE - DO NOT NAIL, i`lE TAL LATH .jf�Mti y STUCCO WRAPawAm ONLY) x X X X Lai �, BUILDINGmeAp INSTALL WITH ROOF CEMENT ! OVER NAILING FLANGK STOP VMP I Uf' ABOVE 6H'IE ONLY) A. STUCCO FRAME OR p"6! eIae ROOF CEMENT SxSWALL FLAW" � � � ROOF PER ELEVATIONS WOOD SHEATHING r % OR'1/16' ZIP SHEATHING 5Y5TEM DMKIC`"LouT (SEE ,� � � g SELF-ADHESIVE FLASHING \ NOTE: — — — — A IF ZIP SHEATHING SYSTEM IS NOTE: INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES 1"IET/4L LATH: LATH TO k3E PAR SECTION FELT / YMEN' — + NSEA. (aEND OR soumn Do R�O3.-1.1 / �4ST1"I C-84i-Q9, 1" INN. 2.5 LBS. SHINGLE ROOFING t1�O FLASHING AT 00"I� OF ROOF a DRIP EDGia:OVERLAPS', PER SQ. YARD (UTILITY OR NOl" IIN,AL EXT&O '� r C� I} ISELOW SHEATHING, MECHANICALLY FASCIA WRAP FASTEN4'0.6MAX "L" FLASHING LATH D O S NOT 1"I T �./ P I� C I F 1 C 74 T I ON S I (: 5 N.T.S. 1441 N. RONALD REAGAN Sl LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 r �11'1'1 ��11'111� SUBDIV. ee LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL: 4EHB "2605-HAYDEN" C;ARAGE ST#MC;: RIGHT PAGE: WALL ASSEMBLY DETAILS 60 MPH EXP. 05/23/18 ' SCALE: 1/4"=1'-0"' SHEET WAl IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS NSTALLATION PROCEDURES BACKER ROD WRB LAYER M, STUCCO WRAP LJ RYER VENT 8' INSTALL 6' SELF -ADHERING MEMBRANE FLASHING OVER TOP, SIDE(S) AND BOTTOM FLANGES OF NON -MOVABLE FRAME OF THE EXHAUST. VENT CAP IS TO BE $ IN BED OF SEALANT At TOP D SIDES ONLY. SEAL T IS TO BE TOOLED SO AS DEFLECT WATE AY F JOINTS. E- AL7 AROUND t-SEALANT ALL D INTERSECTIONS A SEALANT AT PERIMETER OF OVABLE FRAME AND STUCCO ALL SIDES, 4' CAULKING a JOINT LL AROUND PER SECTION R703.7 Exterior lathing and plastering Exterior use of portland cement plaster shall comply with the application requirements of ASTM C 926-12A. Installation of exterior lathing and framing all comply with ASTM C 1063-12A. HOODED NCOA a' THICK, 3 PLASTER METAL LATH WRB LAYER 02, FOR BUILDING PAPER WOOD SHEATHING ( FRAME VIECSJ OR WRB LAYER M, STUCCO WRAP WRB LAYER 02, PC BUILDINGS PAPER 6' WIDE STRIP SELF ADHESIVE FLASHING:, CLEAN MASONRY BEFORE APPLYING STONE OVER WI/STONE VENEER (FRAME TO BLOCK) LEGEND DRAINAGE PLANE (WRB LAVER 01, STUCCO WRAP) WRB LAYER 02 (FORTIFIBER BUILDING PAPER) METAL LATH STUCCO COAT X—X—X—X WOOD SHEATHING OR 1/16" ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS.) SELF-ADHESIVE FLASHING NOTE: METAL LATH: LATH TO BE PER SECTION R103.1.1 / ASTM C-841-0% MIN. 2.5 LBS. PER 5a. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) STUCCO FINISH V SELF ADHESIVE OVER TOP 4 SIDES SELF FLASHING UNIT PREMANUF. DRYER VENT CAP (SET IN CONT. SEALANT) SEALANT m TOP E SIDES 6B DRYER VENT (BLOCK) BUILDING PAPER OVER 'QUICK FLASH' PIPE THROUGH / WALL 1 6' SELF ADHESIVE — FLASHING (INSTALL PER MANUF. SPECS.) BUILDING PAPER — UNDER 'QUICK FLASH' IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES VENT PENETRATION ri SCALE- N.T.S. ELEC. METEF VERIFY LO STUCCO SCRATCH COAT E 1 COAT OF PAINT W/5ACK- ROLL PRIOR TO ELEC. METER INSTALLATION METER FIELD =Y LOCATION -1/16" ZIP SHEATHING (INSTALLED PER Me WRB :R 02, FORTIFIBER PAPER THICK, 3 COAT CEMENT TO Ye' MID -WALL 6' SELF N FLASHING WOOD FR WALL I VE NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES Y STUCCO SCRATCH COAT AND ONE (1) LAYER OF PAINT PRIOR TO INSTALLING ELEC. METER CAVITY TO BE FILLED WITH RIGID POLYMERIC ISOCYANOTE-POLY5LEND FOAM `"' "� 1' 11 �)R SIMILAR) APPLY A SILICON BASE SEALANT AT POINT THAT ELEC. WIRE PENETRATES :;0 SCRATCH COAT LARGER THAN THE ELEC. METER CAN OR METER CAN COM50 OR METER CAN AND DISCONNECT O ELECTRICAL CONDUIT PENETRATION CUT OPENING IN APPROVED HOUSEWRAP FOR DOX INSTALLATION WRB LAYER *I, STUCCO WRAP WOOD SHEATHING APPROVED HOUSEWRAP BELOW GUT SUCH TWA' NO MEMBRANE ENTERS Box, APPLY TO FA( EDGE APPLY E-Z BEAT OVER 60 MIN GRADE 'D' FELT -PROVIDE SEALANT AT ALL JOINTS AND INTERSECTIONS -1/16' ZIP SHEATHING SYSTEM LINSTALLED PER MANUF. S.) OR WOOD SHEATHING / WRB LAYER 49 STUCCO WRAP Voil '�A�� FORTIP15ER WIDE STRIP SELF �HESIVE FLASHING, CLEAN 6014RY BEFORE APPLYING e (FRAME TO BLOCK) NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WRB LAYER "I, STUCCO WRAP CUT 'X' INTO SELF-ADHI=RIMS MEMBRANE FLASHING APPLY SELF -ADHERING MEMBRANE FLASHING OVER BOX AND OVER APPROVED WRBLAYER 01 STEP #1 APPLY 60 MIN - GRADE 'D' FELT OVER SELF -ADHERING FLASHING OVER APROVED HOUSEWRAP STEP #3 •v•v•v•v D •o .o.o.o 0 o• D• OooO•.. oO.• o•D•. O `. Do o eo 0 8" STEP #2 WRB LAYER 01, STUCCO WRAP SELF -ADHERING MEMBRANE FLASHING WRB LAYER 02, FORTIF15ER BUILDING PAPER STEP #4 ELASTOMERIC COATING OVER STUCCO/ G.Y. FINISH (SEE TYPICAL WALL SECTION) METAL LATH StEP "5 STEP #(o OELECTRICAL RECEPTACLE 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 go F N y U W 4 F 4 SUHDIV. 8o LOT: CREEKSIDE LOT 44 PitoJ'ECT# 04321.00OZ 044R1 MODEL4 4EHB "2605-HAYDEN" GARAGE S'WrNG: RIGHT PAGE: WALL ASSEMBLY DETAILS 60 MPH EXP. ARCHITECT- STATE OF RLORDA A NT D TE: 05/23/18 SCALE: 1/4"=1'-0" SHEET EXT. D FRAMED WOOD SHEATHING WALL WRB LAYER M, STUCCO WRAP SU5-FL ECKING WOOF WRB LAYER •2, FORTIF ER CONSTRUCTION BUILDING PAPER PR8-ENG'p 55 �/�` HAT CHANNEL THICK 3 COAT MENT WEATHER R"ISTI W/%' TYPE 'X' DRYWAL PLASTER BARRIER 6' SAP. w TOP QF WEEP SCREED WEATHER RESISTIVE ^^ TO ING HIND WEEP SCREED BARRIER 02 4, THICK 3 GOAT CEMEN V ARIES WOOD SHEATHING PLASTER ._. �` \�` METAL LATH WRB LAYER W, STUCCO WRAP WOOD SHEATHING , THICK, 3 COAT CEMENT r l PLASTER . 6' SELF-ADHEREING AM66-WFWC-IW CUSTOM GAS i I T FLASHING WRAPPED r • f ` NO TOP OF WEEP SCREED •�: I I \ TO SHEATHING BELOW F WRB LAYER M, STUCCO WRAP 4' POSITIVE DRAIN WEEP SCREED O WRB LAYER 02, FORTIFIBER N AP FIELD BUILDING PAPER (SHOWN FORA9EMPIOATION OF ----- ----------- r SEPARATE ACC IES ONLY) �` • '': r 6' SELF-ADHEREING r r FLASHING WRAPPED WRB LAYER r s CORNER OF CANTILEVER STUCCO WRAP ` � � DRAIN II 4' IT AMIGO AM66-WFW80 C-i`� 1 Z CUSTOM CASING BEAD � (SIAC CLARIFICATION OF NOTE: SECESSORIES ONLY) IF ZIP SHEATHIN SYSTEM IS SING BEAD INSTALLED, PLEA SEE L. ® CANT. MANUFACTURERS 10ACALE: I I/2'=I'-0' INSTALLATION PRoc URES NOTE: METAL LATH: LATH TO BE PER SECTION R103.1.1 / A5TM C-841-0S, MIN. 2.5 L55. PER 5Q. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET 5RECIFICATIONS) fF SHEAT411NG 154TEI'1 IS I WOOD CONSTRUCTION INSTA MANUF INSTALLA RESILIENT CHANNEL 5/8' TYPE 'X' DRYWAC6 W/TEXTURED a PAINTED FINISH a' THICK, 3 CO PLASTER DRIP EDGE 11 D INSTALLATION IF SHEATHING S S M IS INST ED, PLEASE S E MANUFA RERS INSTALLAt PROCE URES 5/8' TYPE 'X' DRYWALL W/TEXTURED a PAINTED FINISH — i' THICE PLASTER BARRIER "1 ;KTHICK, 3 COAT CEMENT PLASTER METAL gLATH oR-�n� zl�+He T44T��IHir Iro at�rt (2 2�F�EAMW o ) JI C/1CIt1♦,L T4 AW (SHOWN FOR SEPARATE L IN OF ONLY) WOOD CONSTRUCITON BARRIER "1 *"'THICK, 3 COAT CEMENT PLASTER METAL LATH W912. gµpk 6YSTEM J VI ASING BEAD --"' G / NO GAP IN FIELD \ (6/ )SHOWN FOR CLARIFI SEPARATE ACCESSORIi ION OF S-ONLY) EXTERIOR GRADE PRY WALL J' THICK, 3 COAT CEME PLASTER VINYL���R�� 0 CANTILEVER DR EDGE LEGEND DRAINAGE PLANE (WRB LATER *11, STUCCO WRAP) WRB LAYER *2 (FORTIFIBEIR- BUILDING PAPER) METAL LATH x x x x 5TUGGO WOOD 5NEATHINC i% OR "1/16' ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS.) 5ELF-ADHE51VE FLA5141NG 1s: FINISH LAYER l2 LAYER 3' X 3' 26 GA. METAL DRIP E £L a STICK) SET IN FULL OF 6' EL a SEALANT, Xi' STI •DRIP SPACE F DRIP ED O FACE TOT X ' Ya' Gofm FOR BACKER I NXI -y4" P.T. SIMULATED,"'-Z a SEALANT WOOD (TREX) LER CONTINUOUS CASIN,QQ BEAD WATER PROOFING I 1 WEATHER RESISTIVE LAYER (2 LAYER L a BARRIER M STICK) WRAPPED F WEATHER RESISTIVE BALCONY DECK TO BARRIER 02 CANTILEVER A J 6" PEEL a STICK is DECK MEMBRANE, DRIP EDGE t0 DECK EXTEND OVER DRIP SUB FLOOR EDGE ®® 3' X 3' 26 GA. GALV. METAL DRIP EDGE = = --- ----- - - ---- --------- -------- SET IN FULL BED OF I VXI -/a' P.T. OR I AT SEALANT, �' MIN. WOOD ItREX) FI E SPACE FROM DRIP CONTINUOUS FACE TO TREX Y4 GAP FO VNYL CASING A ROD a SEAL W TER PROOFING let FINISH LAYER AYER TLA R (2 LAYER PEEL a PEEL a STICK) STIC WRAPPED FROM 3/4 RESILIEN 13ALC Y DECK TO HAT CHANN CANTIL R v NY GASBEAD " THICK GOAL CEMENT PLASTER METAL LAT DRYWALL WOOD SHEAt G WEATHER RESIS VE W)TEXTURE a PAINTED BARRIER el FINISH WEATHER RESISTI J' THI 3 COAT CEMENT 15ARRIER 02 PLAS R 4' POSITIVE DRAIN NY CORNER BEAD WEEP SCREED VidYL CASING BEAD NO GAP IN FIELD (SHOWN FOR CLARIFICATION Or - SEPARATE ACCESSORIES ONLY) BALCONY DRIP 11A EDGE INSTALLATION — 2x FRAMING MEMBER J' THICK, 3 COAT CEMENT PLASTER 2 1/2 ° CORNER BEAD FASTENED TO SHEAT4 G *1" O.C. MAX. / X—X—x--x N 7 " WRAP I: OD SHEATHING METAL LATH a ."I WRB YER 02, FORTIFIBER BUILDI PAPER ORNER BEAD C AME 2 1/211 CORNER BEAD (FASTENER 4 SPACING tv rt" O. N N 1 dR�CORNER BEAD i 1 LJ I CMU V THICK, 3 COAT CEMENT PLASTER APPLIED DIRECTLY TO MASONR'r @) BLOCK Y4' GAP FOR BACKER ROD a SEALANT VINYL CASING BEAD WATER PROOFING let LAYER (2 LAYER PEEL 4 STICK) • .rwrra. ^ FEEL a WOOD SHEATHING WRB YER of, — STUCC WRAP WRB LAYER FORTIF1 5ER BUILDING PA R\ METAL LATH J' THICK, 3 COAT CEM T PLAS PEER (2'SELF—ADHERING FLASHING DRIP CAP OLUMN SHEATHING EATHER RESISTIVE BARRIER M EATHER RESISTIVE sARRII:R 02 ' SAP. PEEL a STICK -I Ya"x3' 'L' FLASHING FULLY EMBEDDED IN ROOF CEMENT I V X 3' 26 GA. GALV. METAL DRIP EDGE SET IN FULL BED OF SEALANT, X6' M SPACE F RI FACE TO T511a�t 7 (T X) FILLER S FR SEALANT PtER ROD. - I IFIEp 90 /4 RESILIENT AT CHANNEL iPq WEATHER RESISTIVE BARRIER 01 WEATHER RESISTIVE BARRIER °2 EXTERIOR COLUMN COLUMN SHEATHING 6' SAP. -I ,16"xV "L" FLASHING 'FULLY EMBEDDED IN ROOF CEMENt I it' X 3' 26 GA. GALV. METAL DRIP EDGE SET IN FULL BED OF SEALANT, JJ' MIN. SPACE FROM DRIP 'FACE TO TREX WATER PROOFING lot LAYER (2 LAYER PEEL a STICK) WRAPPED FROM BACONY DECK TO \AXN-TilLEVERK, 3 COAT CEMENT ER /8' TYPE 'X' DRYWALL METAL ATH W/TEXTURED a PAINTED FINISH — WOODS ATHING ' THICK, 3 COAT CEMENT WPOSITII PRAIN PLASTER A IN FIELD VINYL CORNER BEAD (SHOWN FOR CLARIFI TION OF VINYL CASING BEAD SEPARATE ACCESSOR S ONLY BALCONY DRIP 11C EDGE INSTALLATION C9) COLUMN ( W/" L" FLASHING SCALE: NTS NJ ) IF ZIP SHEATHING SYSTEM INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCE R WOOD SHEATHIN WRB LAYER , STUCCO W AP WRB L ER #2, FORTIRBER BUILD Cs PAPER ME AL LATH THICK, 3 COAT CEMENT PLASTER WINDOW FLANGE ' WR` L YE Stott � yJF.'lQ�P ; , FORTIFIBEIR " BUIL APER 1 1 META LATH 1 ' HICK 3 GOAT CEMENT ; ASTER � � i 6'5ELF-ADHERING • FLASHING QRIP CAP WINDOW FLANGE 1 CASING BEAD C) WINDOW ( FRAME. NO BAND) 1441 N. RONALD REAGAN BLVD, LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 04 w A W 0 tj W A SUBDIV. & LOT: CREEKSIDE LOT 44 PROJECT# 04321.000 044R1 MODEL' 4EHB "2605-HAYDEN" GA %AGE SWING: RIGHT PAGE: WALL ASSEMBLY DETAILS 60 MPH EXP. C ARCHRECTI STATE Cr— FLORIDA 9 DA 05/23/18 SCALE: 1/4"=1'-0" SHEET WA3 UJRB LA *I, STUCCO WRB LAYER "2, TIFIBER BUILDING: PAPER ------ METAL LATH \\ I THICK, 3 COAT CEMENT PLASTER ro'SELF-ADHERING FLASHING VINYL ANGLED CASING BEAD DRIP CAP WINDOW FLANGE NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WOOD 5HEATH WR5 LAYER , STUCCO W P WR5 L ER #2, 1=ORTI�IBER BUIL G PAPER I/ AL LATH " THICK, 3 COAT CEMENT PLASTER *I, a!MLAY V I Y ANG IN A-Q LAYER "2, FORTIF ER ; BUILDINGS PAPER LATH METAL i' THICK, 3 COAT CEMENT PLASTER ; &'SELF -ADHERING :1 FLASHING DRIP CAP WINDOW FLANGE CASING BEAD � WINDOW 15C iFRAME, W/BAND) SHEATHING METAL L H WRB LAYER #1, STUCCO WRAP WR5 LAYER #2, FORTIFI BUILDING PAPER 8" THICK, 3 COAT CEMENT PLASTER VINYL ANGLED CASING BEAD 4.I VINYL CASING BEAD NOTE: IF ZIP SHEATHINGS SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES L5 IX TRII" o STUG SIDING SIDING ON WR5 LAYER "I, STUCCO WRAP ^ Ya' GAP TYP CASING BEAD TO TRIM F /uhNi1111,M.i�X.® THICK, 3 COAT C NT PLASTER METAL LATH L ER 02, FORTIFIBER I ING PAPER OD S!-IEATHING WRB LAYER MI, STUCCO WRAP `— 6' SEL DHEREING FLASHING PEEL E STICK SIDING TO STU666 WWOOOODDC STRIIGTION WOOD SHEATHING — WEATHER RESISTIVE BARRIER h TArHER RESISTIVE - !BAIER n 1 . A. STARTER GALV'D METAL 'T' FLASHING II,1V XD6l 811MU�L. modo mmm ��. CASING BEAD (CROSS SECTION) \ 6' SELF -ADHERING FLASHING WEATHER RESISTIVE BARRIER Of WEATHER RESISTIVE BARRIER r1 y �4 FLASHING HERING GALV'D METAL W FLASHING DO NOT CAULK OR SEAL �NINd 6' SIMULATED TRIM MEMBER GAP W)C4ULKING 'PROVED SEALANT SEALANT WINDOW 2X FRAMING MEMBER ' THICK, 3 COAT CEMENT PLASTER METAL LATH a a 4 - WRB LAY *2, FORTIFIBER BUILDIN PAPER E-Z BEAD VINYL CASING BEAD VINYL CASING (W/%" FLEXIBLE PVC 546KER ROD) WRB LAYER "I, UCCO WRAP, WRAPPED AR ND FRAMING M MEBER &" L A HESIVE FLASHING EATHING T FLOW EXPLODE R CLARITY TYP THICK, 3 COAT CEMENT G BEAD PLASTER SEALANT WINDOW METAL LATH WRB LAYER *2, FORTIFIBER UILDING PAPER M WINDOW FRAME D SHEATHING l� I I /INDOW FLANGE NOTE: METAL LATH: LATH TO BE PER SECTION I2X FRAMING R-1031.1 / ASTM C-84-1-09, MIN. 2.5 LBS.MEMBER �ATHING PER SQ. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) BUILDING WRAP lUR5 LANrER #1, BEY ._..__.._.. WOOD THING STUCCO URAF WEATHER STIVE---., BARRIER M WEATHER RESISTI BARRIER "2 WR5 LA'rER#2, FORTIF-18ER XX7"Y'LAPSIDING 51JI L D I 1 G; FAFE R 6 ADHERING 1`OtE T A L LATH STARTER STRIP--'�\ NORI 8" THICK, 3 COAT CEMENT `='LA&TEIR GAK-A METAL FLASHING I Y4' x 6' SIMULATED UlvOD TRIM MEMBER / CASING BEAD @) RAISED BAND (FRAME) 1 ` A SCALE: 1 1/2"=1'-0" 6' 1 -I-UEATNER RESISTIVE BARRIER M WEATHER RESISTIVE BARRIER n / GALV D METAL W FLASHING DO NOT CAULK OR — SEAL OPENING WEATHER RESISTIVE BARRIER "I TO LAP 6' MIN. ABOVE TOP 'Z' FLASHING I Y' X 6' SIMULATED (W/%' FLEXIBLE PVC / M> TRIM MEMBER BACKER ROD) \ / ' SELF -ADHERING 6' SELF -ADHERING I I I ING FLASHINGSEAL \ UWCAULKING CEMENAT T 3ASTER \`� OR A P D SEALANT WEVIN ATHER RESISTIVE WEATHERV ISTIVE E-Z BEAD BARRIER q BARRIER 7 UEATHER RESIST BARRIER n (W/%- FLEXIBLE BACKER ROD) SIDING TO STUCCO WEATHER RESISTIVE ® FRAME TO FRAME BIER n TRANS ITIO N WR5 LAYER *I, STUCCO WRAP 6' WIDE PEEL 4 STIC OVER FLANGE E-Z BEAD VINYL CASING (W/3/s' FLEXIBLE PVC BAC ROD) *APPLY FULL BED OF SEALANT BETWEE FLANGE 4 BUILDING WRAP BEAD WINDOW CASING LEGEND DRAINAGE PLANE (WR5 LAYER 005TUCCO WRAP) WRB LAYER 02 (FORTIRBER - - - - BUILDING PAPER) METAL LATH x-x-x-x STUCCO WOOD SHEATHING �Tl OR'IA(va ZIP SHEATHING SYSTEM (INSTALLED PER MANUR SPECS.J SELF-ADHESIVE FLASHING 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 U w 0 w 4 F a SUBDI4. de LOT: CREEKSIDE LOT 44 PROJECT#044R1 04321.000 MODEL: 4EHB "2605-HAYDEN" GARAGE SVMKG: RIGHT PAGE: WALL ASSEMBLY DETAILS 60 MPH EXP. C ARCHITECT- STATE OF FLORDA q 'C PRINT DATE: 05 23 18 SCALE: 1/4"=1'— 0" SHEET L II CUT HOUSEM AT 45' ANGLE MODIPIED 11' O IN HOUSEU) AP APPROVED HOUSEWRAP OVER SHEATHING OVER WD STUD WALL STEP 1 INSTALL 6' SELF -ADHERING FLASHING OVER NAILING FLANGE AT JAMBS EXTEND FLASHING MIN I' BELOW SILL FLEXIBLE FLASHING DO NOT SEAL SOTTOM FIN STEP 6 NOTE: IF ZIP 5I-4EATH1NCx SYSTEM IS IN5T,4LLED, PLEASE SEE MANUF,4CTUR€IRS INSTALLATION PROCEDURES APPLY j0VER JOINT 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 E W U W O U W 4 F 4 Fti ti 00 SXMDIV. de LOT: CREEKSIDE LOT 44 PROJECTS 04321.000 044R1 MODEL• 4EHB "2605-HAYDEN" GARAGE SVMG: RIGHT PAGE: WALL ASSEMBLY DETAILS: WINDOW FLASHING 60 MPH EXP. C ARCHrTECT- STATE OF FLORDA NDA.A AR NO D TE 05/23/18 SCALE: 1/4"=11— 0" SHEET