HomeMy WebLinkAboutBLOWER DOOR TEST FORM M ' Planning&Development Services -.- Building&Code Regulation Division r�COUNTY 2300 Virginia Ave,Rm 201 SCANNED • • I D A Fort.Pierce,FL 34982 B Phone:772-462-2165 Fax:77249 - 44bB COMOV, RECEIVED I BLOWER DOOR TEST FORM APR ®41019 House Infiltration Test Certification Permitting DepartmentSt.Lucie county I Prescriptive and Performance Method i Date vl 3 Permit#: I;!"''ddress: Conactor: t CZ �o Cz rod Job II '670'S C� FJh 1-e-5 n_e— t Con Itruction: ( ) New Construction—Complete ( ) Existing—After Addition i IE Ho a Infiltration Test Results SLC Climate Zone 2 .J CFA(50)_ Test Date: Volt me= AC911' (50)=CFM(50)x 60/Volume= n Mechanical Ventilation required less than 3 ACH Pas ing results must be&ACH(50)or less K)Pass ( )Fail FBC,�P' nergy Thel wilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hou in Climate Zone 1,2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blo er door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Sect lon 553.993(5)or,(7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g)or(i)or an app�o ved third party. A written report of the results of the test shall be signed by the party conducting the test and pro cIed to the code official. Testing shall be performed at any time after creation of all penetrations of the building the al envelope. FBC I Residential Why,re the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a prey sure of 0.2 inch w.c. (50 Pa)in accordance with Section R402.4.1.2 of the'Florida Building Code, Energy Conservation theyl t welling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3. Tesin Company // 1 ,C Co ''pany Name: Address: 6 l��—17 N W ( m wm4 c``Ir (fl�l /- I h eby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation q1ui rereme i ccordanc h Sectio R402.4.1.2 Climate Zone 2. Sig ature: f Pri ted am Lic I nse/Certification#: l f b Planning&Development Services Building&Code Regulation Division 2300 Virginia Ave, Rm 201 1tt:CEtVEo Fort Pierce, FL 34982 772462-2165 Fax 772462-6443 - FIX ENERGY CONSERVATION CODE Duct Sealing Certification PermttCtng Department Prescriptive and Performance Method St.Lucie Count\/ o-71 -1 Date. Permit#: Lot#: Control or: ��`� C�V��� Address: S-7 o S `�j��"��8h-� �r� 14 • t�'rCP� Constrl ction: Post Construction Test ❑Rough-in Test Test Conditions: n Da 1 I: Floor Area(ft2): .+C Ti I e: Primary Location of Supply Ductwork L Ind I or Temperature(F): -7 Primary Location of Return Ductwork Oul or Temperature(II III Total Leakage Test Outside Du 'Leakage: ❑DefauI ❑Prop.Leak Free (Proposed On= Ter, ressure: �J (Pa) ;� (_ 13 Bass"ine Duct Pressure(optional) (Pa) /'��(•rc V� Du c Press.(Pa) Flow Ring Fan Press Flow(dm) Results: *Pass ❑Fail Installed Pa 2 III Total Leakage(cfm): J I, p'I Total Leakage per 100 sgft: I'I CFM25 x 100 divided by the CFA=Duct Leakage CFM1100 sgft. I� I, �j I Testing Company r �L r �L / Company Name: Address: 0-7 ld( j Co m M , y �v I her,9by cerfdy at a above Duc ng Leakage ults demonstrate compliance with 5"h Edition FBC Energy Conservation requirements in accordance with Section R403.2 Signature: Prinl�d Nam ��'�` License/Certificate#: ��_ �o`) 2 - t i i I i I I'