Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BUILDING PLAN PAGE 17-22
Planning & Development Services Department • Building & Regulations Division 4 Product Review Affidavit Building Permit # Owners Name Applicant k Product Opening Design Product Rated Manufacturer Model # Product Approval Glass Type Method of Attachment Pressure Design Pressure Number 1J4" concrete screw 6" edge distance @head, 4" edge Swing door (+36) / (-47) (+67) / (-67) Therma-Tru Smooth Star FL20461.17 N/A distance @jamb, 4" each side of transom centerline to bucking. Fastener spacing @ 15" o/c max. @head and jamb. Min. embedment of all anchors to be 11/4" Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from corners, 11 3/4" o/c at jamb, 16" @ head. 1 1/4" embedment. Type II: 3/16" or 1/4" ITW concrete tapcon SH Window (+38) / (-48) (+50) / (-50) Ply Gem Ply Gem 1500 FL16103.1-R9 Non Impact anchor. 6" max. from corners, 7 1/4" o/c at jamb, 10 1/4" @ head. 1 1/4" embedment. Two additional tapcons rnidspan and one at lower frame required vertically each side. Install per manufacturers recommended requirements. Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from corners, 14" o/c at jamb, 10" @ head. 1 1/4" embedment. Type II: 3/16" or 1/4" ITW concrete tapcon anchor. 6" max. SH Window (Integral (+38) / (48) (+S0) / (-55) Ply Gem Ply Gem 1500 FL16100.1-R6 Non Impact from corners, 8 1/2" o/c at jamb, 6" @ head. 1 1/4" Mulled) embedment. Eight, additional tapcons top and bottom required horitontally, one midspan vertically each side. Install per manufacturers recommended requirements. 1/4" concrete tapcon anchor. 2 1/2" minimum edge Sliding Glass Door (+33) / (41) (+50) / (-50) Ply Gem Builders Series FL14634.2-R3 Non Impact distance. 6" max o/c from corners and 20 3/4" max o/c 4780 elsewhere top, vertically and bottom. 2 1/2" min embedment. 1/4" concrete tapcon anchor. 6" max o/c for corners. Tapcon required 3" each side of center of opening top and Opaque single door (+36) / (47) (+47) / (47) Therma-Tru Smooth Star FL14985.1-R2 N/A bottom. Top and bottom centerline of each door slab get with transom tapcon. Rest of vertical o/c spacing is 14" max. 1 1/4" embedment. 3/8" x 2-3/4" Hilti sleeve anchors 6" from ends 22" O/C Double Garage Door +29) / (- 35) (+46) / (-42) Clopay 16.2x7 73 W6 FL16546.6-R9 N/A Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" dia. heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per Roof IKO Cambridge FL7006.1-1110 shingle placed 6-1/8"above the butt edge, approx. 1" and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. Miami -Dade approved corrosion resistant tin -caps and 12 Underlayment Interwrap RhinoRoof U20 FL15216.1-R3 gauge 1'/," annular ring -shank nails, spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. in the field of the roll Soffit +31.6, -38.8 (+157) / (-46.1) PlyGem Variform Soffits FL24161.1 1/4" x 20 stainless steel or ELCO Paneimate with minimum Hurricane Panels Hurricane Storm embedment @ 1 3/4" in concrete /masonry, 2 1/2" min. Less than 6' span (+47) / (-53) panel MFG. 24 GAGE FL16293-R2 edge distance, 12" o/c max. spacing. Can be headed screw or all thread but with wing nuts. 1/4" x 20 stainless steel or ELCO Panelmate with minimum Hurricane Panels 6' Hurricane Storm embedment @ 1 3/4" in concrete /masonry, 2 1/2" min. span or more (+45) (-50) / panel MFG. 24 GAGE FL16293-R2 edge distance, 12" o/c max. spacing. Can be headed screw, or all thread but with wing nuts. � Zip System Install per manufacturers recommended requirements. Sheathing Huber Wall Sheathing 17147-R2 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-7746078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 w U w 0 4 W A ti A t� l9VHDIV. as LOT: CREEKSIDE LOT 55 P1tOJECT# 04321.000 055R1 MODS 4EBB "1828-CALI" GARI►C#S 191iINCF: LEFT PAGE: PRODUCT APPROVALS 160 MPH EXP C 06/01/18 NOTE: NOTE: IF ZIP SHEATHING SYSTEM IS APPROVED BUILDING WRAP IF ZIP SHEATHING SYSTEM 15 INSTALLED, PLEASE SEE SHALL BE LAPPED A MINIMUM OF INSTALLED, PLEASE SEE 4'x4' SELF -ADHERING MEMBRANE— 6 ° MANUFACTURERS b° • VERTICAL LAPS (ROLL FLASHING (COMPATIBLE LW HOUSE ENDS) ! 6' S HORIZONTAL LAPS. MANUFACTURER/'WRAP MATERIAL) OVER 4° INSTALLATION PROCEDURES ALL SEAMS NEED 70 BETELATH VERTICAL LAP TO BE I' INSTALLATION PROCEDURES APPROVED HOUSE WRAP. \\ WITH FORTIBER SHEATHINFLASHING TO EXTEND ONTO PIPE " OR LESS PIPE x_ 6'x6' SELF -ADHERING MEMBRANE PREFORMED CONTROL JOINT �° THICK, 3 COAT CEMENT PENETRA7ICN FLASHING (COMPATIBLE Wl HOUSE ` WRAP MATERIAL) OVER 4'x4' FLANGE OF CONTROL JOINTS T \ PLASTER ` SELF -ADHERING MEMBRANE BE WIRED TIED TO LATH or S' \ WRB LAYER M2, FORTIFIBER / FLASHING OVER APPROVED O.C. MAX (VERY.). NOTE; p0 BUILDING PAPER i^ niN. LAP 9 MErHOUSE WRAP. NOT FASTEN CONTROL JOINT TO FLASHING TO EXTEND ONTO PIPE WALL EVEN IF STUD EXISTSBEYOND EXCEPT STAPLES W/ APPROVED METAL LATH X X LEG MAY BE USED TO TEMP. FASTENED 47' (VERT.) O.G. MAX r^ j SECURE CONTROL JOINT AT SUPPORTS X X X DURING INSTALLATIONER 01, CUT AND OVERLAP ONE SIDE OF FASTENERS TO BE SPACED STUCCO YWRAP CUT AND OVERLAP ONE SIDE OF METAL LATH SELF -ADHERING MEMBRANE FLASHING SELF -ADHERING MEMBRANE s t' OZ. MAX VERTICALLY STEP) STEP *1 FLASHING WOOD SHEATHING I OR 1/16' ZIP SHEATHING - WRB LAYER "I, J' THICK, 3 COAT CEMENT SYSTEM AINSTALLED PIER STUCCO WRAP PLASTER W� LAYER w, iE STUCCO WRAP MANUF &. Co.) / METAL LATH I1JRB LAYER 12, FORTIFIBER MIN PAPER LAP BELOW ONLY WRB LAYER M2, FORTIFIBER BUILDING PAPER ' r .,_' - W� LAYER N2, FORTIFIBER BUILDING PAPER I BUILDING PAPER METAL LATH \ / WRB LAYER M, I 6°xb' SELF -ADHERING MEMBRANE STUCCO WRAP FLASHING OVER 4'x4' SELF -ADHERING MEMBRANE \ INSTALL FASTENERS (CLIPS, HOUSE WRAP. To § I FLASHING OVER APPROVED LATH SHALL NOT SAP M", WOOD SHEATHING STRAPS, STAPLES) AS BE CONTINUOUS 6" To a° 6- To a° OR'1/16' ZIP SHEATHING RE=IRED TO SECURE FLASHING TO EXTEND ONTO PIPE MN ,...I SYSTEM (INSTALLED PER PIPE/ WIRE TO FRAMING THROUGH CONTROL JOINTS BUT SHALL t M F. SPECS.) 4'x4' SELF -ADHERING MEMBRANE BE STOPPED AND ` .;:",, '�. �:k TIED AT EACH SIDE. FLASHING OVER APPROVED PER ASTM E EACH SI PROVIDE 2X4 BLOCKING 1' MIN LATH FFLLASHING TO EXTEND ONTO PIPE i.l0.1.4 PLACED FLAT MAX b' TO S' La' 4"OVER 1 ET- . LL LAP FROM CONTROL JOINT WHEN APER LAP NOTE: \ CONTROL JOINT FALLS ON 2 V CONT. BEAD OF SEALANT \ /r STRUCTURAL STUD SCALE: I I/2'=1'-0' I. FASTENERS FOR LATH TO BE NAILS OR INSTALL APPROVED HOUSEWRAP AIR STAPLES IN COMPLIANCE W/ ASTM CI063 INFILTRATION BARRIER OVER 2. WIRE TIES TO BE (NO. IS) 00415' WIRE SHEATHING 3. BLOCKING SHOWN MAY BE IN ADDITION \ ELASTOMERIC COATING OVER STUCCO/ 70 WALL STUDS REQUIRED PER PLAN / G.Y. FINISH (SEE TYP WALL SECTION) e4'ul'' VERTICAL LATH & PAPER DETAIL WOOD STUDS ti \, S CT ION PER SECTION R703.7 Exterior lathing and plastering NOTE; SµE,g7µINCs di Exterior use of portland cement plaster SIDE LAPS OF METAL OR -/16' ZIP SHEATHING SYSTEM : shall comply with the application PLASTER BASES SHALL (INSTALLED PER MANUF. SPECS.) a requirements of ASTM C 92612A. BE SECURED TO BUILDING NOTE: 6 MIN. Installation of exterior lathingand framing 1 ,> FRAMING MEMBERS- PAPER LAP IF ZIP SHEATHING SYSTEM IS shall comply with ASTM C 1063-12A. M TYPE CONTROL JOINT THEY SHALL P TIED INSTALLED, PLEASE SEE BETWEEN SUPPORTS MANUFACTURER5 WITH 0.0415-IN. (ICI-MM) STUCCO ,t %5^ LAP w LATH WIRE AT INTERVALS NOT ; 3" LAP PAPER INSTALLATION PROCEDURES MORE THAN 9' (22e-MM). AS PER ASTM all O I. FOLD INWARD • pr. A ( f } 1. FOLD INWARD • Pr. A 1�.I. )N.T.5. FIFE F>�l T � A i I Old � T A f L C F �,� 1'~'C 2. DREAM • For. B NOTE: ®FOLD ® 4 K�C KO UT FOR REPAIR OF TEARS HORIZONTAL LATH DETAIL MAY BE LAYERS, TEARS & PAPER DETAIL W/HOUSE WRAP TAPE PER MANUF. SPED. OR roLD PEEL d STICK • 4& ® 7/16" ZIP 5HEATHINr3 SYSTEM ( INSTALLED PER MANUF- SPECS.) OR L FOLDI. INWARD • ( Q, I FOLD INW4RD . Pr. A WOOD SHEATHING OR GMU �. 2. CEASE R• Pr. B ; WRB LAYER *I, 2. GREASE • t•'I'. B s. GREASE • Pr. c 9. GREASE • PT. G STUCCO WRAP (FRAME ONLY) / .. FOLD ". G UG- Pr. 5 TLL.L Pr. G TOUCHES BorroMFLArr,E ® '' �• g' THICK, 3 COAT CEMENT kk PLASTER (FRAME), 1/2' 2 COAT II s CEMENT PLASTER (CMU) LEGEND-/ METAL LATH (FRAME ONLY) ®®LD �' � ©� LAP LURE 4 TAPE OVER I) RA INANE FLAN (LJR5 OM WATERTIGHT ROOF/U1ALL SCREED LANT- IR 1*1/ eTUCCO WfRAF=) • 7T• B01T FLANGE NOTE: SEAL. FOLD, eQ IF ZIP SHEATHING SYSTEM IS NQ1cuT' INSTALLED, PLEASE SEE j' THICK, 3 COAT CEMENT ? 5'X5" "L" TYPE CONTINUOUS '' �jRj LA�1R *2 (FORT IF 18 R — — — — — — PLASTER OWME),1/2' 2 COAT -� GAL V. METAL FLASHING MANUFACTURERS C TIEMT P F DECK, NOT 5� I �, � I NG FAFE R� INSTALLATION PROCEDURES TUBS LAYERER *2»2,f FOR (NAIL TO ROOTIFIBER Lt� � �'"` 5UIL.DING PAPERM"I ONLr) WALL SHEATHING) WRBLAYER w, c CAP SHINGLE - DO NOT NAIL, t'o"IETAL LATH X X X X sTucco WRAPrFRa fE GNLn INSTALL WITH ROOF CEMENT LAP LAYERS OF BUILDING WRAP OVER NAILING FLANC£, STOP . 4 OE s 'X G' M�$�JTUCCO a a FRAME OR 0111 EXTERIOR ROOF CEMENT bX5 WALL FLASHIN@ ROOF PER ELEVATIONS WOOD 5HEATHING; o �� OR 1116" ZIP SHEATHING S`t'STEM KICK -GUT FLASFIINOlSEE DETAIL) I ! ( INSTALLED PER 1" IANUr. SPECS.) / \0 NOTE: SELF-7"- )H 51V FLA51—fING — IF ZIP SHEATHING SYSTEM 15 NOTE: INSTALLED, PLEASE SEE MANUFACTURERS 1yIETAL LATE: LATH TO 5E RER SECTION FELTUNDERLAYMENr INSTALLATION PROCEDURES WATER TIGHT SEAL CBBNID OR %%� /A� R/�y I� SOLDER DO NGT GUT) R703.7.1 / A57-1' C-0—r-1-09/ 1�IN. 2.F2 LI../5. F'R'pONI "TALL SHMCsLE ROOFING p jI�,48FHNG AT BOTI�� CF ROOF 1 %� * �A` WALL INTERSEGTIGNS R E R 5 Q. � A RD C U I L I T O R N 01 I N I�i DIEATI41I OVEAKIGALAP , L>4TI� 1�0E5 NOT 1„1' T S�P CIISICATIONS� EXTBVD 1/2' ISELOW SHEATHING, MEGHfWICALLY FASCIA WRAP FASTEN 4' Or- MAX " L" F L AS H I N G- 5 N.T.S. 1441 N. RONALD REAGAN Bl LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 F W U W ti. O F 0. a W A E SVHDIV. de LOT: CREEKSIDE LOT 55 P1iOJECT# 04321.000 055R1 MODEL: 4EBB "1828—CALI" GARAGE ®111l LEFT PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP C ARCHITECT: STATE OF FLORIDA ROLAND A. A AR NO 06/01/18 SCALE: 1/4"=I,-0" W"XI "Wlil 11 NOTE. IF ZIP SH tWING SYSTEM IS INSTALLED, LEASE SEE MANUI=AGTU RS INSTALLATION ROGEDU 'Ea INSTALL (0" SELF -ADP MEMBRANE FLASHING TOP, SIDE(S) AND ISO FLANGES OF NON -MO) FRAME O- THE EXHAL VENT Is 8E SET IN BED OF AL T T TOP AND X SI SEALANT 16 TO BE t L AS TO DEFLECT AY FROM JOINTS. E- AD ALL AROUND N APPLY SEALANT ALL k TS AND INTERSECTIONS LY SEALANT AT PERIMETER OF BACKER ROD 5 ON -MOVABLE FRAME AND STUCCO ON ALL SIDES, 4" CAULKING a JOINT ALL AROUND PER SECTION R703.7 lathing and plastering BACKER ROD _Exterior Exterior use of portland cement plaster shall comply with the application I'X requirements of ASTM C 926-12A. In Ilation of exterior lathing and framing shal omplv with ASTM C 1063-12A. WR5 LAYER *1, STUCCO WRAP HOODED vE T X X 'THICK, 3 COA EMI PLASTER METAL LATH WR5 LAYER *2, FORTIF PSUILDING PAPER WOOD SHEATHING A DRYER VENT ( FRAME), 8" CMU (INSTALLED PER Mr- S GSJ OR WOOD OHEATi-1411 •WRB LAYER "I, STUCCO WRAP WRB LAYER , FORTINEER /RAIS;=P R BEAD D r .� 6"WIDE STRIP SELF ADHESIVE FLA84W3, GLEAN MASONRY BEFORE APPLYINCS z FLASHING OVER KRATCH COAT H IZONTAL WEEP SCR W/STONE VENEER (FRAME TO BLOCK LEGEND DRAINAGrz PLANE (UJR5 LAYER #1, STUCCO UJRAP) WR5 LAYER 02 0=ORTII=I5E1R - - - - - 5UILDINC PAPER) METAL LATH x-x-x-x 5TUCCO WOOD 5HEATHINC OR 1/16" ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS.) SELF-ADHE51VE FLA5HING - - - - NOTE: 1' FETAL LATH: LATH TO 5E PER SECTION R103.7.1 / A5T1" 1 C-S41-09, MIN. 2.5 L55. PER SQ. YARD (UTILITY OR N01"(INAL LATH DOES NOT MEET SPECIFICATIONS) ELEC. METEF VERIFY LC STUCCO FINISH 6" SELF ADHESIVE OVER TOP d SIDES SELF FLASHING UNIT PREMANUF. DRYER VENT GAP (SET IN CONT. SEALANT) SEALANT TOP E 501=S 6B DRYER VENT (BLOCK) BUILDINGS PAPER OVER "QUICK FLASH" PIPE THROUGH WALL I 6" SELF ADHESIVE — FLASHING (INSTALL PER MANUF. SPECS.) BUILDINGS PAPER — UNDER 'QUICK FLASH" r IF ZIP IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES A- VENT PENETRATION SCALE: N.T.S. HI�,>=H I CJ I V= STUCCO SCRATCH COAT 4 1 COAT OF PAINT W/5ACK- ROLL PRIOR TO ELEC. METER INSTALLATION METER FIELD =Y LOCATION WOOD CONSTR.ICT1 7/16' ZIP SHEATHINGS SY EM i/16" TIP SHEATHING SYSTEM (INSTALLED PER MAN . SPECS.) OR (INSTALLED PER MANUF. SPECS.) OR WOOD 5HEATI-I I G ffs WOOD SHEATHING LAYER *I, WRB L� R srU(: WRAP � STUG UJ P ft WRB LAYER 02, FORTIFIBER Y 15UILPING PAPER METAL LATH R "2, FORTIFIBER PAPER WOODTEa CONSTRUCTION woop ���INISP ®woop F FASTEN TO WOOD STRUCTURAL A : MEMBER o T' O.G. MAX COAT CEMENT Ye' TO )j' MID -WALL WEEP 6CPSED O 78" MID-WALL� &Uj1P SCREED 6' WIDE STRIP SELF ADHESIVE FLASI-41NG, GLEAN MASONRY B) FORE APPLYING 6" SEL DHE51VE FLASH INCzTEXTURED FINISH A MASONRY WOOD FRA DB HORIZONTAL WEEP SCREED WALL TTT\ IV /V T TT ( FRAME TO BLOCK) IN GEN&{_-- • I' • NOTE: IF ZIP SHEATHING SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES Y STUCCO SCRATCH COAT AND ONE (1) LAYER OF PAINT PRIOR TO INSTALLING ELEC. METER CAVITY TO 5E FILLED WITH RIGID POLYMERIC ISOCYANOTE-POLYBLEND FOAM ,11� "� ' �"��" ')R SIMILAR) APPLY A SILICON BASE SEALANT AT POINT THAT ELEC. WIRE PENETRATES :;O SCRATCH COAT LARGER THAN THE ELEC. METER CAN OR METER CAN COM50 OR METER CAN AND D I5CONNECT O ELECTRICAL CONDUIT PENETRATION CUT OPENINGS IN APPROVED HOUSEWRAP FOR BOX INSTALLATION WR5 LAYER 01, STUCCO WRAP WOOD SHEATHING APPROVED HOUSEWRAP BELOW CUT SUCH TWA NO MEMBRANE ENTERS Box, APPLY TO FA( EDGE 5T E '*1 STEF #3 APPLY E-Z BEAD •o•o.o•° OVER 60 MIN °'°'° ° •o o. GRADE' "o• •" •• FER LT-POVIDE ° • • ° SEALANT AT ALL o0 00 JOINTS AND o • o• ° INTERSECTIONS I to Y. 0 , o , oqu NOTE: IF ZIP SHEATHING SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WR5 LAYER *I, STUCCO WRAP CUT "X" INTO SELF -ADHERING MEMBRANE -LASHING APPLY SELF -ADHERING MEMBRANE -LASHING OVER BOX AND OVER APPROVED WR5 LAYER *I APPLY 60 MIN - GRADE "D' FELT OVER SELF -ADHERING FLASHING OVER APROVED HOUSEWRAP 5TEF 4 WR5 LAYER *I, STUCCO WRAP SELF -ADHERING MEM5RANE FLASHING WRB LAYER *2, FORTIFI5ER BUILDING PAPER ST f ELASTOMERIC COATING OVER STUCCO/ G.V. FINISH (SEE TYPICAL WALL SECTION) METAL LATH SiEE P "�5 STEP #ro OELECTRICAL RECEPTACLE 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 PAQ W 0 h a U w �i F Q h L9VHaIV: as LOT: CREEKSIDE LOT 55 PROJECTAIi 04321.000 055R1 ad0]�aBL: 4EBB "1828-CALI" GA6RAGE 81 n4G: LEFT PACE: WALL ASSEMBLY DETAILS 160 MPH EXP C fD 06/01/18 SCALE: 1/4 $1=1' — 0'" 311EET WOOD SHEATHINGS WOOD CONSTRUCTION 3/4" HAT CHANNE W/s/s' TYPE "X' WOOD SHEATHINGS WRB LAYER *I, STUCCO WRAP ' THICK, 3 COAT CEMENT PLASTER �Mhc,-uFulr_--IAA r.uA'I r_el WRB LAYER #/r-OFRVr- STUCCO WRAP WRB LAYER #BUILDINGS PATHICK, 3 COPLASTER 6' SAP. a TOPEEDTO SHZ%!R AdING SCREED ` r WRB LAYER #I, STUCCO WRAP AMIGO AM66-WFWC--T&0 \ L CUSTOM CASING BEAD (SHOWN FO CLARIFICATION OF SEPARAT ACCESSORIES ONLY) ASING BEAD 10A DTL. CJ CANT. SCALE: 1 1/2"=1'-(D" — 6' SELF-ADHEREING FLASHING WRAPPED s TOP OF WEEP SCREED TO SHEATHING: BELOW LI LAYER #I, STUCCO WRAP i — WRB LAYER #2, FORTIFIB BUILDING PAPER i i I 6' SELF-ADHEREING FLASHING WRAPPED s CORNER OF CANTILEVER NOTE: IF ZIP SHEATII41N INSTALLED, F`LE,< MANUI=ACTURERS INSTALLATION[ PS EXT, Ad D FRAMED \ WALL FINISH LAYER (2 LAYER 3' X 3' 26 CsA. GSA PRI -ENS D 55 — EL a STICK) I`IEtAL DRIP ED WEATHER RESIST' SET IN FULL OF 6' EL a `� PAGE FsEALANT' DRIP BARRIER Stl DRIP WEATHER RESISTIVE EDGS O FACE t0 t X BARRIER #2 DECK i' THICK, 3 COAT CEMEN V RIES �( `, PLASTER = METAL LATH Y4' G FOR BACKER WOOD SHEATHING I Vxi 3/4" PIT. SIMULATED RO a SEALANT WOOD (TREX) LER, I YL CASING B A CONTINUOUS ti 4�1'I EXTERIORGRADE DRY WALL is THICK, 3 COAT CEM! — PLASTER �Um� • •- • r �.� 10 CANTILEVER DR STEM 15 EDGE SEE uRES LEGEN1r)" NOTE 1"ITAL LATII4: LATI� TO 5E PER 5CTI R�103.-1.1 / A5T1"I C-8�-1-09, 1"IIN, 2.� 5. PER 5Q. ARID (UTILIT`r OR NOl"I AL L I DOES NOT 1" IF T S ECIF AT IONS) NOTE: IF ZIP SWEAT ING SY IS OD CONSTRUCTION INSTALLED, EASE E MANUFACTURERS WEATHER RESISTIVE INSTALLATIO PROCE RE54UJALL BARRIER "1 3/4 RESILWEATHER RESISTIVE HAT CHANBARRIER 02 VINY CA5 �" TCK, 3COAT CEMENT PLASTER5/8' tYt7E METAL LATH i" TH[CKT,/4 COAT CEMENT VINYL CORNER BEAD VINYL CASING BEAD 11D DRIP EDGE INSTALLATION VC/ I =: IF ZIP SHEATHING SS EM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES 5/S" TYPE 'X" DRYWALL W/TEXTURED a PAINTED FINISH 8" THICK, 3 COAT CEMENT PLASTER VINYL CORNER BEAD VINYL CASINGS 5EAD NO GAP IN FIELD (SHOWN FOR CLARIFICATI OF SEPARATE ACCESSORIES Y) WOOD CONSTRUCITON I' WEATHER RESISTIVE BARRIER 01 WEATHER RESISTIVE BARRIER 02 THICK, 3 COAT CEMENT PLASTER �MEETTApL�LµA�I �(u� r71� TRb' ZIP'�IEATF�iFKs SYSTEM Arun=. SMCs-) VINYL CO�4' POSITIVE IN �2 NO GxAP IN FIELD (SHOWN FOR CLARIFICATION OF SEPARATE ACCESSORIES ONLY) DRAINAGE PLANE (UURB LAVER -01, 5TUcc0 WRAP) WRB LAVER 012 (1=0RTIrI5ER ...... - - BUILDING PAPER) 1" IETAL LATH x--x x x 5TUGG0 1__� ` W00D SHEATHING =i, , OR -1/16" ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS.) 5ELF-ADHIESIYE FLASHING - - WATER PROOFING I \ WEATHER RESISTIVE LAYER (2 LAYER P L a\• r BARRIER #1 STICK) WRAPPED FRO WEATHER RESISTIVE BALCONY DECK TO BARRIER #2 CANTILEVER , RAW 4- 6" PEEL a STICK a DRIP EDGE TO DECK DECK MEMBRANE, EXTEND OVER DRIP SUB FLOOR _ EDGE ®® 3" X 3' 26 GA, GSALV. METAL DRIP EDGE SET IN FULL BED OF I vXI 3/4' P.t. OR AT SEALANT, Y�" MIN. WOOD (TREX) FI E SPACE FROM DRIP CONTINUOUS FACE TO TREX INYL CASING BEAD Y4" GAP PO ROD a SEAL W TER PROOFING 1st FINISH LAYER AVER LA R (2 LAYER PEEL a PEEL a STICK) STIC WRAPPED FROM 3/4 RESILIEN ; e BALC Y DECK TO HAT CHAN CANTIL R VINYLCASIN' THICK COAT CEMENT I_. PLASTER METAL LATH TYPE ">y DRYWALL WOOD SWEAT W/TEXTURV a PAINTED WEATHER RESIS VE FINISH BARRIER M WEATHER RESIST[ J" THIC 3 COAT CEMENT BARRIER 02 PLAS R 44' PO51TI���IN VINY CORNER BEAD WEEP SCREED VU4L CA51NG BEAD NO GAP IN FIELD (SHOWN FOR CLARIFICATION Or - SEPARATE ACCESSORIES ONLY) BALCONY DRIP 11A EDGE INSTALLATION Y4" GAP FOR BACKER ROD a SEALANT — VINYL CASING BEAD WATER PROOFING let - LATER (2 LAYER PEE: a STICK) WOOD SHEATHING — 2x HRAI" IING MEMBER g" tl-LICK, 3 COAT CE T sRB GAOY� R�� PLASTER CORNS A WRB LAYER #2, ORT FASTS 51-4EATI-41NG BUILDING PAPS III X. METAL LATH • 8" THICK, 3 COAT CEf aJ LAYER #I, PLASTER UCCO WRAP (0"SELF-ADI4ERING LU D SHEATHING 1-LASHING METAL ATH DRIP CAP WR5 LAVE #2, FORTIFI5ER BUILDING PA R WINDOW FLANGE 1�- ORNER BEAD � AME k 2 I/2" � 1 AIP1CORNER BEAD -E II -1-0 CORNER BEAD (I=A5TENER 4 SPACING 10 1" O.G.) CMu %` THICK, 3 COAT CEMENT PLASTER APPLIED DIRECTLY TO MASONRY OP BLOCK COLUMN SHEATHINGS WEATHER RESISTIVE BARRIER 01 PEEL a WEATHER RESISTIVE BARRIER M WEATHER RESISTIVE BARRIER #2 EXTERIOR COLUMN COLUMN SHEATHINGS •6" SAP. -1 K2"x3' 'L' FLASHING 'FULLY EMBEDDED IN ROOF CEMENT I J' X 3' 26 GA. GALV. METAL DRIP EDGE SET IN FULL BED OF SEALANT, Yt" MIN. SPACE FROM DRIP FACE TO TREX _VINYL CASINGS BEAD WATER PROOFING Ist LAYER (2 LAYER PEEL a STICK) WRAPPED FROM BALCONY DECK TO ANTILEVER ICK, 3 COAT CEMENT PL TER METAE%AWI WOOD 5 ATWINCB V INTL C-UI'bVtK Ot-AL.) J (SHOWN FOR CLARIFICIIATION OF VINYL CASING BEAD SEPARATE ACCESSORTES ONLY BALCONY DRIP 11C EDGE INSTALLATION (9) COLUMN (W/" L" FLASHING) SCALE: NTS NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WOOD SHEATHING WRB LAYER #I, STUCCO '.URA LURE LAY #2, FORTIFSER BUILDIN PAPER META ATH $' T ICK, 3 COAT CEMENT ASTER WRB"LAIYER #I, S-ruccl WRAP WRB LAYS 02, TIF15ER = ' BUILDIN G i METAL LA ; 1 ' THICK COAT °CEMENT � � t ' PLAST , 6"S LF—ADHERING F SHING . , ; DRIP CAP WINDOW FLANGE ING BEAD (4) WINDOW 1441 N. RONALD REAGAN BLVD LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 F W W 0 A F A BVHDIV�Is CREEKSIDE LOT 55 PROJ&CT# 04321.000 055R1 �tOD&L: 4EBB "1828-CALI" C'Fi AMAG E ®1►MG: LEFT PAGIM WALL ASSEMBLY DETAILS 160 MPH EXP C ARCHITECT STATE OF FLORIDA 9 'ROLAND A.ABOUCMACRA AR NO 937231 : d DATE: 06/01/18 9CALlb 1/4"=1'-0" SMIZET WOOM SHEATHING WRB LAY *I, stucco u1R WR5 LAYER V F IFIBER BUILDING PAPER METAL LATH �\ � " THICK, 3 COAT CEMENT PLASTER 6 "SELF—ADI-4ERING FLASHING VINYL ANGLED CASING BEAD --4 DRIP CAP WINDOW E=LANGE 15C vl n NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WOOD 5NEATI4 WRB LAYER , STUCCO W P WR5 L ER 02, FORTH-15ER 51JIL G PAPER ✓ AL LATH a✓" THICK, 3 COAT CEMENT PLASTER L i G � DRIP CAP_ WINDOW FLANGE CASING BEAD WINDOW (]FRAME, W/BAND) SHEATHING METAL LAT WR5 LATER *1, STUCCO WRAP WR5 LAYER *2, FORTIF15E 5UILDING PAPER " THICK, 3 GOAT CEMENT PLASTER VINYL ANGLED CASING BEAD VINYL CASING BEAD CURB LA1'EIQ 02, F-ORTIFi$F BUILDING PAPERS N METAL LAt1-4 " THICK, 3 COAT CEMENT PLASTER 6 "SELF —ADI-4ERING FLA5I-4ING — \\ NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES GI; (EXFDLODED VIEW FOR CLARITY) WOOD SI4EAT Y4" CxAP TY� a " THICK, 3 COAT C NT CASING BEAT? PLASTER To TRIM METAL LATH IX TRIM M5ER m STUCCO SIDING TRAM ION L ER "2, FORtIFIBER I ING PAPER SIDING OOD SHEATHING WRB LAYER "I, WRB LAYER M, 0 StUGGO WRAP �r STUCCO U)RAP CASING BEAD 6" SEL DI-4EREING FLASHING PEEL E STICK SIDING TO S TUC O CASING- BEAD (CROSS SECTION) WOOD CONSTRUCTION BEYOND WOOD SHEATHING WEATHER RESISTIVE BARRIER M THER RESISTIVE — BA IER 02 gfr' X 'I ' LAP SIDING UUJI/6' RE L 6' SELF -AD INCH — FLASHING STARTER STRIP DO NOT CAULK OR2— SEAL OPENING GALV'D METAL = "Z' FLASHING I Y' X 6' SIMULATE'D- Wf�OD TRIM MEMBER oa SIDING TO STUCCO C9) BLOCK TO FRAME TRANSITION .,pI1 L 6' SELF -ADHERING FLASHING WEATHER RESISTIVE BARRIER "1 WEATHER RESISTIVE BARRIER *2 6' SELF -ADHERING FLASHING GALV'D METAL "Z' FLASHING DO NOT CAULK OR SEAL OPENING 61, SIMULATED TRIM MEMBER GAP W/CAULKIO NOTE: METAL LATH: LATH TO 5E PER SECTION R-703-11 / A57"1 G-54-1-09, MIN. 2-5 L55- PER SQ. YARD (UTILMr OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) SEALAN- WINDOW 2X FRAMING MEMSE R 6' SELF- HERING y WOOD SH THING WEATHER STIVE _ FLASHI I I BARRIER M ,f/ HER RESISTIVE RRIER M TO LAP WEATHER�SISTI /� MIK AOP BARRIER / OF 7''LSHING LA�EfR#2, F-OiRTIF15ER PSIDINGWIR5 RE 5U I L D I NG �,�PE Ro b' WEATHER RESISTIVE BARRIER M SELF -ADHERING FLASHING ? RESISTIVE / WAATTWERR 02 111=- TAL L A 1 14 STARTER STRIP / \ GALV'D METAL DO NOt CAULK OR I I W FLASHING -� I /^J� - II I ii I C�1�, 3 GOAT � E � E N T SEAL OPENING \ DO NOT K OR / SEAL OPENING AST GALV'D METAL Z' WEATHER RESISTIVE FLASHINGx BARRIER M TO LAP I Y' 6' SIMULATED 6' MIN ABOVE TOP �-,,,,, 'Z' FLASHING W oXl:l TRIM MEMBER ` E-Z BEAD VINYL CASING 1 4' X 6' SIMULATED (WIV FLEXIBLE PVC / WOOD TRIM MEMBER BACKER ROD) \ / SELF -ADHERING 6' SELF -ADHERING I I i I SHING FLASHING \ lfi' �K, 3 COAT THICK ` SEAL AP W/CAULKING \ CEMENT PLASTER \ OR AP VED SEALANT WEATHER RESISTIVE WEATHER SISTIVE CASING BEAD @) RAISED BARRIER M BARRIER M WEATHER RESIST A V A I BARRIER "2 CW/" FLEXIBLE BAND (FRAME) SIDING TO STUCCO BACKER ROD) WEATHER R6818TIV 17 C9) FRAME TO FRAME BARRIER 02 SCALE: 1 1/2' =1' -011 TRANSITION �n SEALANT WINDOW FRAME FLANGE 2X FRAMING MEMBER BUILDING WRAP 8" TI-41CK, 3 COAT CEMENT ��`� PLASTER / METAL LATH Q '000 ........................................................... WR5 LAY *2, FORTIFIBER BUILDIN PAPER E—Z BEAD VINYL CASING: (W/%' FLEXIBLE PVC B KER ROD) ' — WR5 LAYER *I, VIUCCO WRAP, WRAPPED AR ND FRAMING MEMBER \ETe' 6°L A i-4ESIVE FLASHINGEATH ING ELOW EXPLODED O R CLARITY FG ------------T-41CK,3COAT CEMENT AD PLASTERW METAL LATH WR5 LAYER *2, FORTIFIBER �UILDING PAPER wwZ) 5�4EATI-41NG WRB LAYER *1, STUCCO WRAP (0" WIDE PEEL E STI OVER FLANGE E—Z BEAD VINYL CASING (WA/8" FLEXIBLE PVC BACk APPLY FULL BED OF SEALANT BE FLANGE E BUILDING WRAP ROD) 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 w y U w 1. O F p F etter�ry ae LOT: CREEKSIDE LOT 55 PROJECT# 04321.000 055R1 MODEL: 4EBB "1828—CALI" GARA 1M 811►1114G: LEFT PAGE: BEA.� WIN�C�W CASING WALL LEGEND DRAINAGE PLANE (WR5 LAYER *I, STUGGO WRAP) WR5 LAYER *2 (FORTIFI5ER ...... — 5UILDING PAPER) METAL LATH x—x—x—x STUCCO WOOD SI-IEATHING K OR 1/16' ZIP SI4EATP NG SYSTEM (INSTALLED PER MANUF. SPECS,) SELF-ADHESIVE FLASHING — ASSEMBLY DETAILS 160 MPH EXP C DATE: 06/01/18 09CALM 1/4"=1'-0" CUT HOUSEIUR. AT 4b' ANGLE MOpiF1ED 111, CUT IN HOUSEWRAP LINE OF WINDOW - OPENING APPROVED HOUSEWRAP OVER 6HEAT41NG OVER WD STUD WALL STEP I INSTALL W SELF -ADHERING FLASHIN* OVER NAILING FLANGE AT JAMBS EXTEND FLASHING MIN I' BELOW SILL FLEXIBLE FLASHNG DO NOT SEAL BOTTOM FIN STEP 6 NOTE. - IF: ZIF 6H ATH (N 6�6T � 15 f N6TAL L , �L A6 6EE fi�ANL�FACTL� 6 f N6TAL L AT f CN f=fROC6 APPLY MEM®BANE FLASIING OV ' ER JOINT OF WINDOW WITH 1441 N. RONALD REAGAN BLVD LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 F W W U W ti �o F V T7 A F Cv stmorv. de LOT: CREEKSIDE LOT 55 PROJECT�Ji 04321.000 055R1 MODEU 4EBB "1828-CALI" GARAZZ SMNG: LEFT PAGE: WALL ASSEMBLY DETAILS: WINDOW FLASHING 160 MPH EXP C DATE: UD/U1/lt3 8CALIM 1/4"=1'-0" 8IZET I o I� 2xro SUS -BAND W/1 "x4" NOTCH Is END, WRAPPED IN PEEL s STIOG DRIP EDGE 7/5" TEXTURED FINISH 0 WOOD 1/2" TEXTURED FINISH 6 CMU METAL FA 1\ 1\ I\ I\ I \ I \ 2X(p SUB 1 I \ METAL FASCIA \ O WRAP Yale FROM \ STUCCO, I" FROM \\ WOOD WALL \ EXTERIOR WALL \ (FRAME OR CMU) \\ \\\ NOTE: NOTCH FOR 2X6 \\ 5U5 SAND ONLY' \\ I ( )ELEVATION - ROOF KICK OUT REMOVED \\ FOR CLARITY \ ROOF DECK (BEYOND) \ DRIP EDGE, 1" OFF WALL NOT INTO STUCCO) 1 1/S" TEXTURED FINISH /WOOD, 1/2" TEXTURED JI FINISH a CMU 2x6 SU5-5AND W/1"x4" NOTCH IT END, WRAPPED IN PEEL 4 STICK METAL FASCIA WRAP 1" OFF WOOD WALL. 5U5 BAND 2" OFF WOOD WALL 1/8, TEXTURED FINISH A WOOD, I/2" TEXTURED FINISH 0 CMU METAL LATH LUOOD SHEATHING OR CMU OURS LAYER 01, 5TUCCO UJRAfO(FRAME ONLY) U1R5 LAYER *2, FORTIFIBER 5UILDING 10APER (FRAME ONLY) ROOFING CEMENT DRIP EDGE METAL KICK OUT SUB BAND DETAIL Cap WALL NOTE, IF ZIP 5HEAT4NG SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES I \ -\ x x x x ; x x x x x\ x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x ' PRE-ENG'D TRUSS TO 5E CUT x x x x x x x x x x x x x , WALL LINE TO AVOID CONTACT x x x x x x x x x x x W/TEXTURED FINISH x x x x x x x x x x 2 "x4"X4' -0" x x x x x x x x x x -" SCABBED TO TRUSS x x x x x x x x W/12d NAILS roll -a" x x x x x O.C. MAX. -'/ x -" 2x SU5-5AND W/IY"x4" NOTCH 6 END METAL FASCIA WRAP DRIP EDGE EXTERIOR WALL (FRAME OR CMU) SUB BAND DETAIL C� WALL W./KICK—OUT- FRAME OR CMU FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. Y4" A50VE 5OTTOM OF DRIP EDGE 2x SUB -SAND W/IY2"x4" NOTCH 6 END, WRAPPED IN PEEL 4 STICK *ROOF CEMENT ROOF EDGE OMITTED FOR CLARITY FRAME OR CMU WALL KICK -OUT FLASHING FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. Y4" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/V2llx4" NOTCH a END, WRAPPED IN PEEL 4 STICK *ROOF CEMENT ROOF EDGE OMITTED FOR CLARITY 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 w U w 0 F y q h �a E: to AA w� Ai 3n'!� r d , aM orv. Z IAT: CREEKSIDE LOT 55 PROJZCT* 04321.000 055R1 MODMIA 4EBB "1828—CALI" GARAGE 19MMG: LEFT PAGE: WALL ASSEMBLY DETAILS: SUB —BAND 160 MPH EXP C ARCHTECT: STATE OF FLONDA 01 m nA E:4 08/01/18 SCAUD 1/4" 8HEET