HomeMy WebLinkAboutPOOL SPECIFICATIONRETURN LINES 2.5" TO FIRST TEE RETURN LINES FOR SPA 2.5" TO FIRST TEE POOL DETAIL SPA DETAIL APPROVED MAIN DRAIN FRAMES AND GRATES PER APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASMF/ANSI 112.19.9-2007 V.G.H. ASME/ANSI 112.19.8-2007 • APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR • APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 1 RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION , 6T" EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT , ' ENTRAPMENT AVOIDANCE ' AVOIDANCE ' E UNBLO-C-KABLE CHANNEL DRAIN UNBLOCKABLE CHANNEL DRAIN ' . E E E , , , P E , E , ' ♦ 8 FPS MAX • ♦ It FPS MAX 3" PLUMBING LINES 3" PLUMBING LINES - 3" LINE TO PUMP FROM SUMP W/ 3" 2.5" SUCTION LINE 70 FILTER 3" SUCTION LINE TO PUMP FROM SUMP W/ 3" .5" SUCTION LINE TO PUM MAX 181 G.P.M. TEE PUPM MAX 14T G.P.M. MAX 181 G.P.M. TEE' MAX 117 G.P.M. 8 FPS MAX 8 FPS MAX 8 FPS MAX 8 FPS MAX TO FILTER PUMP TO JET PUMP TO FILTER PUMP Jandy ePump Series High Head Pumps Total Dyne to Head Full -Rate (JEP) Pounds Per Square Inch (Peet o1 water) (PSI) 11« 1« NE 11 eSHUFM, JEP-2.0 HP, SAI50 RPM FILTRATION ANDWATERWATER eRmP. JEP-1.6 NR 14W RPM TEAT t• JEp2.0 HP, "Do RPM sPIMq. PL . JEP -1.5 HP. MOD RPM IS SO_ ePump. JEP.2.0 NP, OPM MBE EP-2.0 1m. ZANE RPM ,e _ ��.JNOA �-�.� �-16PO FPM - _.- ePunll], EP4.S HP. Za00 RpM E ._.�_.--�.- ,.....- .- .- - .- ,. 4 t4 90 « p « « « « « 1« T1p 1« ,« ,tl t« fA Fp 1tl Zp M ffi 1« ]40 RSO FILLY Rated, Gallons Per Minu« (GPM) GRADE WATERLINE I.S. OVERFLOW 24" TO FRENCH DRAIN BASIN I SPA JET PUMP MISC. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT AREA WHERE DECK RAISED ABOVE POOL T OUND WIRE DRAIL BONDING DETAIL 12"MA%.WHERE APPIJCABLE 48" MAX prNTE,. TIONAL ELECTRICAL CODE WATER DEPTH -' I-10" MIN. STEP ETAILIS MIN. OF IV WIDE. OT GREATER THAN 12" EXCEPT HAN (3) TREADS ARE USED. EPS TO BE SOLID 00 PSI. STEP_ DETAIL ----- N.T.S. HEATER(GAS) 3- #12 THHN CU WITHIN 2/d' CONDUIT HEAT PUMP W/(2) #6 CU, (1) #10 NUET. 2HP JANDY PLUS HP PUMP MOTOR & & (1) #10 CU GROUND IN %" CONDUIT 1HP VS FLOPRO PUMP W/BUILT-IN 80 AMP POOL PANEL OVERLOAD SWITCH W13-#10 THHN CU W/(3) -#4 THHN CU WITHIN D/4" WITHIN A" MIN. CONDUIT ELECTRICAL CONDUIT MANUAL MOTOR SWITCH #8 SOLID CU GROUND WIRE TO EXISTING PANEL VARIABLE SPEED FLOPRO PUMP MOTOR Tj_3 W/BUILT-IN OVERLOAD SWITCH W/3-#10 S.P.S.T. TOGGLE THHN CU WITH -IN %2" CONDUIT SWITCH TIME CLOCK W.P. DISCONNECT (8) POOL LIGHTS (GFI NOT REQUIRED) (1) SPA LIGHT IF APPLICABLE (GFI NOT REQUIRED) 1. ALL ELECTRICAL TO COMPLY WITH 2O14 NATIONAL ELECTRIC CODE. 2. 3412 THHN CU WITHIN'/2" MIN. CONDUIT FOR POOL LIGHT (S) 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER. 4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B) ELECTRICAL DIAGRAM N.T.S. 4 ft. fb IC CO) 3X4 DOOR PAD 500 GALLON COLLECTOR TANK WUJ:L (ITOFILL TO WATER r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- ---------- FEATURE PUMP 45 ft. 1 --r --- 3X4 PAD FILL LINE FOR AUTOFILL SCREEN ENCLOSURE WITH 2 DOORS SUPER GUTTER AND DOWNSPOUTS WITH I POTABLE WATER TO HOUSE INCLUDES 4 PORCH PANEL AND 30' WIDE PICTURE FRAME BACKFLOW PREVENTER i I i --------- --- .... - 1' - 2.5" 41 I RAISED FIRE PIT +18" OUTLINED WITH GLASS TILE _ _ _ _ id,) FLOOR RETURNS FOR - -O 1.5" WATER FEATURE PUMP I I 1 411" DEEP I 1 _ 24 ft. _ _ H­ 5 ft. 6 in. 5ft. 9in. III--- 3.5'DEEP $ 1 I I- I N 1 T 3'- a 4i , I r'- 3"------ - �--- ---- - - - - -- 2.5" -----0 AUTOMATIC FIRE PIT TILED STEP COLOR LED COLOR LED ELEMENT FROM GRAND EDGES 1 H LIGHT EFFECTS WITH GLASS MEDIA AND 4'6" X 18" -- CUSTOM GAS ELEMENT -- ------- ---- - - - - I _ 1M i 1.5 'A �I +1III CHAMPAGNE SIP611 R ABOVE POOL OUTLINED STEP i WITH TILED COLOR LED ECI O DRAIN � 1" 3„ I I I i C 7 ft. 3 in. i I Te 2.5' -._ _......__. --.. _. ------.___.-----_.....: • • • • •-• Ir•- •_•_-- .-._. ._ SILVER TRAVERTINE PATIO WITH TRAVERTINE COPING MUD SET ON TOP OF CONCRETE II c COVERED LANAI T I I NOTE; REMOVE GRATE & WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP LINEMEN EMPTYING POOL 6I TYPICAL WALL_ SECTION 8t WELL POINT GRATE SHALL (NO SCALE) BE SECURED IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVALEL-TEX FORM 6KRAFT WALL F@ 12" O.C.B.W. THREADEE: FOR DEPTHS PLUG ER THAN 6'ADD 1- VE BAR @ 6" O.C. TO PUMP -► GRAVEL BED 32" Channel Drain Flat Grate Anti -Entrapment Suction Outlet Cover and Three -Port Manufactured Sump VGB Series The AwastaT line a suctian UNDER covers, co"AAMint ech the new Product canon Sheet V]rl0nia GPaP -Baker Pool d1Td SP Sarety Act (ASNLE/ANSI At i =1 Features Aimme.urvM rumeA ti,LWlelro] will The Unblockable!- a5.9 sown a0 rv'yM1,W MnR:T vIT Two Drains in One!!! M.. ., ny"pyler MrryVMRp"Fmw.l Y3XDRvw 18" MIN. ( ENTIRE PERIMETER) PAVER DECK OR CONCRETE DECK W.L. _. j I SOIL k8 SOLID COPPER BOND WIRE W/APPR. CLAMPS (ONE ON EACH SIDE OF 8 GA (ONE COPPER POOL 4 TOTAL) WIRE - I I I I I I EQUIPOTENTIAL BONDING. GRID. DETAIL MINIMUM 18" FROM EDGE OF POOL AROUND ENTIRE POOL PER N.E.C. 2014 SEC. 680.26 PERIMETER BURIED 4" TO 6" (WHERE ADOPTED) DEEP e i `J O O p A t JE 6 4 J 2 1 EQUIPMENT LAYOUT N.T.S. LEGEND SAFETY BARRIER: PROVIDE 48" HIGH MIN. FENCE PER LOCAL CODE W/ SELF -CLOSING, SELF -LATCHING GATES AND APPROVED 48" HIGH BABY BARRIER FENCE SAFETY BARRIER PER FRC 4601.17-4601.17.1.15 & ASTM5034-95, ASTM D3787-89, ASTM 653-96 & R4501.17.1 THRU R4501.17.3 POOL BARRIER PER FRC 4501.17-41.1.17.3 AND ANSI/NSPI-5-1995 TRAVERTINE COPING 1 3/4" OVERHANG\ 1 1" VENT 2" DROP - 3" DRAIN - TO 4" LINE TO COLLECTOR TANK 1. 3" POOL RETURN TO FLOOR RETURNS A. JANDY 2.0 V.S. JEP V.E. PUMP W/APPR HAIR & LINT STRAINER E TILED BEAM WATERLINE WATERPROOF GUTTER PERIMETER OVERFLOW POOL WITH COLLECTOR TANK 2. 3" DRAIN LINE FROM TANK B. JANDY 2.0 V.S. JEP JET PUMP W/APPR HAIR & LINT STRAINER 3. 2.5" SPA JET RETURN C. 1.5" TO WASTE OR TO GROUND 4. 3" SPA MAIN DRAIN LINE D. JANDY 2.0 V.S. JEP CIRC. PUMP W/APPR HAIR & LINT STRAINER 5. 2.5" POOL DRAIN LINE E. VALVES (TYP) 6. 3" POOL MAIN DRAIN LINE F. JANDY CS200 CARTRIDGE FILTER WIPRESSURE GAUGE AND AIR RELIEF VALVE 7. 2" VACUUM LINE G. JANDY 400,000 BTU GAS HEATER W/ INTERNAL BY-PASS S. 2.5" DRAIN FROM SPA H. JANDY JE2500 TITANIUM HEAT PUMP WITH INTERNAL BYPASS 9. 2.5" SPA RETURN I. JANDY "AQUA -PURE SALT SYSTEM 10. 2.5" POOL RETURN LINE TO FIRST TEE J. 500 GALLON COLLECTOR TANK INL F--OOTER DETAIL (1) #5 REBAR WE o 8" NO SCALE 4" MIN. UNDEWATER LIGHT SP 10-221'ALL FITTING INSIDE PIPE POOL FINISI l SWIMOUTS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE APPROVED WITH FBC 2014WATETRLINE _jTI 1 s1E20" max. -+ BUILDING CODE FOR RESIDENTIAL 6th ED. VERIFY EXACT LOCATION IN FIELD WITH HOMEOWNER EQUIPMENT PAD PER FBC R4501.22 EQ.- LAYOUT P P P CO i GAS HEATER MUST BE MINIMUM 48" AWAY FROM WINDOW H 1/4IS = 11 30" MIN. CLEARANCE IN FRONT OF SUBPANEL ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. IS ASSUMED FOR THIS DESGN. NOTE; CLEAN FILL COMPACTED TO 95% MAX. CRY DENSITY UNDER DECK ONLY POOLBOND PB-2008 DECK WATER COPING NOT :REMOVE GRATES TRAVERTINE DECKING MUD SET WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP LINE WHEN EMPTYING POOL SAVI NICHELESS 6"X6" TILE LED LIGHT 0 4" THICK 30DO PSI FIBER INTERIOR REINFORCED CONCRETE GRATE SHALL FINISH BE SECURED IN TYPICAL WALL NO NICHE 1" LIGHT PLACE SO SECTION & WELL PI CONDUIT THAT TOOLS UNDERWATER ARE REQUIRED FOR REMOVAL INC SCALE) STEEL-TEX FORM LIGHT DETAIL 6" TYP. II R KRAFT WALL 1.5" SCH 40 PVC (NO SCALE) 1, FLOOR #3 @ 12" O.C.B.W. SLEEVE NOTE. FOR DEPTHS THREADER REATER THAN V ADD 1- PLUG #3 COVE BAR @ 6" O.C. TO PUMP -► GRAVEL BED LOCATION OF WATER BOND LOCATE IN -FIELD RL zf LLDGR SLOPES SHALL R96SQNABLY UNIFORM AND COMPLY WITH ARTICLES S &i THRU SA WIRE 1 ROW OF WATERLINE TILI WA @ 12" O/C E.W. SPECIFICATIONS MAX. WIDTH 19' MAX. LENGTH 24' MIN. DEPTH 3'-6" MAX. DEPTH 411" SHAPE CUST ELEVATION T.B.D FILL FROM EXCAVATION: STOCKPILE TILE: INCLUDED STONESCAPES POOL PUMP: 2.0 JEP VARIABLE SPEED V.E. PUMP: 2.0 JEP v n ANe Y PmAT SPA PUMP: 2.0JEP PUMP MAKE PER FSC4501.20 LIGHTS: POOL (8) LED SPA (1) LED FILTER: JANDY CS200 CARTRIDGE MAIN DRAIN: POOL (2) SPA CHNL RETURNS: POOL (4) SPA (2) JETS: POOL NA SPA (10) VALVED VAC LINE INCL FILL LINE INC DISCHARGE LINE TO GROUND JANDY TRU CLEAR SALT SYSTEM INCL HANDRAIL NA LADDER NA HEATER: JE2600 HEAT PUMP & 400,000 BTU_GAS JANDY RS6 "ONE -TOUCH" WhAQUALINK & INTERFACE VACUUM HEAD INCL POLE INCL VACUUM HOSE INCL BRUSH INCL TEST KIT INCL TREE / STUMP REMOVAL NA REMOVE EXISITING CONCRETE NA FOOTERS INCL SCREEN ENCLOSURE PIONEER SCREENS ELECTRICAL THRU GRANDE CONSTRUCTION POOL PATIO SILVER TRAVERTINE COVERED PATIO SILVER TRAVERTINE DECK DRAIN 3" REMOVABLE CAP DOD_ GALLON CAPACITY -POOL 14,600 GAL. GAI LON CAPACITY -SPA 900 GAL. Tl 1-OVER RATE 6 hrs TERMITE TREAT INC BARRIER INC MAX, WATER VELOCITY- FR M TR _ TO 8 ft.ls SUCTION LIN�MAX RETOR 'LINE SKIMMER MIN. -FLOW 25 GPM -Sr ACE AREA OF POOL - 438 SQ.-FT. 9` GENERALNOFES: ].SWIMWNFULAMCONSIRUETONT000M1TLY WIFIJ. RLDO.CODE pX0 WRNALL LOCpL OROWpNCEBAND l xW-NGuuTLM 9.SWMIMXIGPOOL FO BEARD"E MMOR"ppSNRBEO DDEUB LL USa ANOROMFUTHELL SURNERT MPGIREOISMALL BCMMED IF BOIL IMUM USE].WeP.&1.HRIS2 II!]LRM ,NET OR IVE6111ENGFN. ]. ENGINEER SMALL BE MIMED IF BOIL SEARWG IE93 TNpp35W P$F.OR MVCI(.9MTOR LOME.BMSOIL MFWN&AFryOIL BEAMG CAPACIOP2.6W P.SF. HAS BUM HUDS NTHE TENDS, A.REINFORCINGBARESHA WNEW&LLET.OI 40, 6. ALL POOL PIPING TO BE P.V.C. ECHERULE AO MIN. AND BEAR ME NSF. APPROVAL 6. RAKKNAMP ALL B E IN COAPIMNCE SAM LOCAL ORDINANCES. ].03PoEYL OFPMLMMR6M CONM MTOLOCALORMNA M.SYRFACEOMDMSHALLCONTAIN WI WATERTXW PROPERWMMPPVOWGSx NOTPMR 1FORMORETNA"OxEHOUR. E WATER SUPPLY S DISPOSAL SHALL BE INSTALLED Be THAT THERE IS "D CRO66 SUNUCTION WRX A DME6iW OW AT T "I OR WER ATOWPDSAL 8Y61EM. P. WUIEAT WIH DRAW SI{ALLIMVEA FREEAREq OiM 1XENMAOFTHE eYCTYJN LINE IkMR&IWiSTMINMY HAVEAREApVABLE6CREENWIAMIMIMFMEEAREADF3STIEAREAOF ME AUSTEN LINE 11, ELECTRICAL: W6TALL BURNS & SUMEE AS SHOWN IN POOL DATA HUDSON. UG T CONNECTOR To CONFORM TO NATURAL E]ECTRICAL CODE. LATEST BURNS. 12. ALL METALLIC OUST UIR. FUNI SYSTEMS. REINFORCES STEEL LAMTMMRES 8 NWEW, NEML PARTS OF IADOERE, HANWUAd.DWINS BOARDS A 6UPPMM N BE BONDED TOGET WL A MWNpE6 TDA cOMMLYI GNOUMp.6oxDWG eQNOUCTGt SHALL NOT BE EMAILER MAN M Be n. ND OVERSEAS OUR NRE OVER POOL MTER, EL... RLTRR SHALL BASS A FILTMTON RATE NOT TO F}CFPD3 W.MI&F. OF FILTER ANNE. NO BACK.WAS" REQUIRED. 16, CONTRACTp(E"pLL VERIFY ALL WMENSIWS AND COHO"ENe AT 611E BEFORE STARTING ME PROJECT. COUMACIOR SH U. VERIFY LOCATON OF ELECTRICAL HARBOR BY FPAL COMPANY. 1&SPECIAL ATHAT ON SHALL BE OWM TO FASTER FOUNDATION TO PRESENT UNDERMING. JOB NAME: STEINBERG ADDRESS: 2007 ROYAL FERN CT PERMIT NO.: DATE DRAWN: JULY 16, 2018 DRAWN BY: TRAVIS LEONARD DESIGNER APPROVAL: CUSTOMER APPROVAL: SCALE: 114" = V RAY REINHARD ppp PE # 47041 1010 Easter Lilly Lane Unit203 Vero Beach, FL 32963 \IU:ONCRETE POOLS, INC. JUL 272018 ST. Lucie County, Pert SCANNED t. Lucie ' ANS AND ALL PROPOSED WOfW A,L SW-3JECT TO ANY CORFECTIONS f GIu;,Fi D EN FIELD INSPECTi3IIS @HAT f'IAY QE NECESSARY If1 Ofq(iiM TO COMPLY WITH ALL APPLICABLE CODES. _ 6" THICK IF LIGH WALLS S , LUC E C NTY REVIEWED CO 4'11" SHALL REVIEWE BY NOT DATE 6" THICK SLOPE PLANS NO RMIT GREATER SITE OR NO INSPE( THAN 11' CYCOLAC MAIN DRAINr I �� 39M 21' 3' �L4 24' RAY REINHARD TYPICAL SECTION THRU POOL PE # 47041 (Na®LACE) 1010 EASTER LILLY LN. KEPT ON 308 WILL BE MADE