HomeMy WebLinkAboutBUILDING PLANS (5)RECt 1 i015 SCANNED
sty. "l We CorIof\
Planning & Development Services Department
• Building & Code Regulations Division
-- — - -- 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
I' Certification for Design Load Compliance
Proj ctName:
Project Address: �U /,�'
i
Per it Occupancy Type: R31 Construction Type: WB
I
INSTRUCTIONS FOR USE:
• This certification must be completed, signed; and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
i' o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
ertain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
DESIGN CODE: Florida Residential Code 2010 Edition with 20 Supplements using ASCE 7-10
. Structure Designed as (check one): X Enclosed Partially Enclosed Open
B. Risk Category: _I X II III _ IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: see Sh 2or3 ft
S. Mean Roof Height 15 ft Roof Pitch: --> :12 Parapet: --� ft (See Sh 2 or 3)
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
+29.5 +32.1 +32.1 +55.8 +55.8 __
Zone 1: -50.9 Zone 2: -88•8 Zone 3: -131.3 Zone 4: -60.5 Zone 5: -74.7 Garage: --� (See Sh 2 or 3)
7. Design Loads: Floor: 55 PSF Roof/Dead: PSF Roof/Live: 20 Balcony: 55 PSF (See Sh 2 or 3)
Dock: 40 PSF Deck: 55 PSF Stairs: 40 PSF Fence: N/A PSF, Railings: 50 plf PSF
S. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
11 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? • ' Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. J also'certify that structural elements depicted on these plans provide adequate resistance to the design
forces.p#rifled`:,' ; ,�
Steve Kastner, PE 39528
f Print Name Cert # & Co. Cert Auth. -
�'., Kastner Engineering, LLC
5320 Florida Palm Ave, Cocoa, FL 32027
r ure, ate., ;and SEW
.;_ Company Name &Address
vised 07/25/2014
:NCia
i